Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIGH-R”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Moisture Performance of High-R Wall Systems

High-performance homes offer improved comfort, lower utility bills, and assured durability. The next generation of building enclosures is a key step toward achieving high-performance goals through decreasing energy load demand and enabling advanced space-conditioning systems. Yet the adoption of high-R enclosures and particularly high-R walls has been a slow-growing trend because mainstream builders are hesitant to make the transition. In a survey of builders on this topic, one of the challenges identifi ed is an industry-wide concern about the long-term moisture performance of energy-effi cient walls. This study takes a step toward addressing this concern through direct monitoring of the moisture performance of high-R walls in occupied homes in several climate zones. In addition, the robustness of the design and modeling tools for selecting high-R wall solutions is evaluated using the monitored data from the field. The information and knowledge gained through this research will provide an objective basis for decision-making so that builders can implement advanced designs with confidence.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Performance of High-R Wall Systems

High-performance homes offer improved comfort, lower utility bills, and assured durability. The next generation of building enclosures is a key step toward achieving high-performance goals through decreasing energy load demand and enabling advanced space-conditioning systems. Yet the adoption of high-R enclosures and particularly high-R walls has been a slow-growing trend because mainstream builders are hesitant to make the transition. In a survey of builders on this topic, one of the challenges identified is an industry-wide concern about the long-term moisture performance of energy-efficient walls. This study takes a step toward addressing this concern through direct monitoring of the moisture performance of high-R walls in occupied homes in several climate zones. In addition, the robustness of the design and modeling tools for selecting high-R wall solutions is evaluated using the monitored data from the field. The information and knowledge gained through this research will provide an objective basis for decision-making so that builders can implement advanced designs with confidence.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mitigating Moisture with High-R Walls

Energy-efficient building enclosures are key to decreasing energy load demand and enabling advanced space-conditioning systems for high-performance homes. One efficient enclosure design solution is high-R walls, which feature increased insulation levels as an effective solution for reducing air leakage and permeance of material layers. To increase builder confidence and encourage greater market adoption of high-R walls, Home Innovation Research Labs sought to demonstrate the long-term moisture performance of several high-R wall configurations in cold climate zones. The team monitored 22 newly constructed, occupied homes located throughout climate zones 4–7, where a substantial vapor drive to the exterior is present during the winter.

buildings↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solutions

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

Building America↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solution

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

30 DIRECT ENERGY CONVERSION↗

Field Validation of High-R Windows: Market Assessment and Program Plan

This report provides a market assessment for high-performance residential windows based on information gathered from key researchers and industry stakeholders including a series of interviews conducted with high-performance builders in 2019. The report also outlines the U.S. Department of Energy’s planned field validation activities in support of high-R windows and provides the basis for planned field validation approaches. Although the report may be of general interest to those who work in fields pertaining to building energy efficiency and/or market adoption of energy-efficiency measures, the primary intent of this report is to document market characteristics, barriers, and activities related to high-performance residential windows in order to assist with internal program planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extended Plate and Beam Wall System

Home Innovation Research Labs studied the extended plate and beam wall (EP&B) system during a two-year period from mid-2015 to mid-2017 to determine the wall’s structural performance, moisture durability, constructability, and cost effectiveness for use as a high-R enclosure system for energy code minimum and above-code performance in climate zones 4–8.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance Windows -- More than just a Pretty Hole in the Wall

As more stringent building energy codes and better insulation products combine to yield better performing walls, window efficiency is coming into sharper focus. The U.S. Department of Energy has supported several projects through its national laboratories to improve the thermal performance of windows. At Pacific Northwest National Laboratory (PNNL) in Richland, Washington, the PNNL Lab Homes, two fully monitored identical side-by-side manufactured homes, have been used to test the performance of several window improvements including triple-pane windows, storm windows with low-emissivity (low-e) coatings, smart automated interior insulated shades, and exterior shading products. Findings will be presented on these studies, along with impacts. For example, PNNL’s Lab Home research on low-e storm windows has helped to support a new ENERGY STAR certification, industry standards, and utility incentives. Preliminary findings will also be presented on current Lab Homes experiments focusing on exterior shades. The session will also present findings from related field studies and a market assessment of emerging high-efficiency windows technologies and discuss some of PNNL’s planned field studies that will focus on validating the benefits and costs of the emerging thin triple-pane high-R window.

windows, high-r windows, insulating windows, windo↗

Molecular aspect ratio effect on axial thermal transport in solution-spun carbon nanotube fibers

Neat, densely packed, and highly aligned carbon nanotube fibers (CNTFs) have appealing room-temperature axial thermal conductivity (⁠k⁠) and thermal diffusivity (⁠α⁠) for applications in lightweight heat spreading, flexible thermal connections, and thermoelectric active cooling. Although CNTFs are regularly produced from different input carbon nanotubes (CNTs), prior work has not quantified how the CNT molecular aspect ratio r (i.e., molecular length-to-diameter ratio) influences k and in well-aligned, packed CNTFs. Here, we perform self-heated steady-state and three-omega thermal measurements at room temperature on CNTF suspended in vacuum. Our results show that k increases from 150 to 380 W / mK for viscosity-averaged molecular aspect ratios increasing from r = 960 to 5600 and nanotube diameters of ~2 nm, which we attribute to the effects of thermal resistances between CNT bundles. CNTFs made with varying volume fraction Φ of constituent high-r and low-r CNT have properties that fall within or below the typical macroscopic rule-of-mixtures bounds. The thermal diffusivity α scales with k, leading to a sample-averaged volumetric heat capacity of 1.5 ± 0.3 MJ / m 3 K⁠. This work's findings that fibers made from longer CNT have larger k and α at room temperature motivate further investigation into thermal transport in solution-spun CNTF.

42 ENGINEERING↗

Extended Plate and Beam Wall System

Home Innovation Research Labs studied the extended plate and beam wall (EP&B) system during a two-year period from mid-2015 to mid-2017 to determine the wall’s structural performance, moisture durability, constructability, and cost effectiveness for use as a high-R enclosure system for energy code minimum and above-code performance in climate zones 4–8.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing wall performance predicted from hygrothermal simulations to wall performance measured from environmental chamber experiments

To effectively mitigate prevailing perceptions of potential moisture risks in high-R wall assemblies, a comprehensive moisture durability assessment that incorporates BA team field evaluations, lab tests and simulations has been completed over the last couple years. In FY18, three stick-built walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The measured temperature, relative humidity and moisture content within these walls were compared to WUFI hygrothermal simulation results. In FY19, similar experiments and comparison to WUFI results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The following tasks were completed for these two walls: 1. Measure air permeance of each individual wall using ASTM E283 Standard Test Method. 2.Test walls in diffusion scenario as only moisture transport mechanism and compare measured transient temperature and relative humidity of select wall components to WUFI model results. Chicago summer and weather will be investigated. 3. Test walls in wetting event scenario and compare measured transient temperature and relative humidity of select wall components with Chicago summer weather to WUFI model results. 4. Test walls in diffusion/advection scenario. In addition to controlling outdoor chamber to match real outdoor weather, a pressure differential across the wall will be varied. Measured transient temperature and relative humidity of select wall components will be compared to WUFI model results. 5. Test walls in diffusion/advection with solar heating of cladding. In addition to the variables above, IR lamps will be used to heat the cladding on a diurnal cycle. Measured transient OSB MC and temperature will be compared to WUFI model results. This report documents the experimental method, results and comparison of the measured experimental hygrothermal performance of the two walls to simulations results.

42 ENGINEERING↗

AM03-AM121-115 Hard X-Ray Optics Development at MSFC

We have developed the electroformed-nickel replication process to enable us to fabricate light-weight hard-x-ray region. Two projects currently utilizing this technology are the production of over 250 r from 5 to 10 cm, for our HERO balloon payload, and 15- and 23-cm-diameter shells for a prototype module. The challenge for the former is to fabricate, mount, align and fly a large number of high-r constraints of a modest budget. For the latter, the challenge is to maintain high angular resolution shell thicknesses (100 micron) which make the shells extremely sensitive to electroforming stresses process does not degrade the ultra-smooth surface finish (approx. 3 A required for eventual multilayer c on these two programs.

Ramsey, Brian↗

The Building Science Advisor: A Web-Based Tool to Assess the Durability of Building Envelope Components

The Department of Energy (DOE) and Oak Ridge National Laboratory (ORNL) have developed an innovative new design tool that will put building science expert advice in the hands of every building designer who cares to manage moisture risk in high-R envelope components. As modern buildings become increasingly more airtight, constructed with modern labor-saving materials, and equipped with air-conditioning, they have become less forgiving to moisture intrusion. The Building Science Advisor (BSA) provides building science knowledge and advice based on expert experience, field measurements, laboratory tests, and computer simulations.BSA users are prompted to enter relevant information about the building location, design, and material selection options like cladding, structural system, and insulation. Influential factors such as climate, building air tightness, material properties, and internal moisture loads are also considered to estimate and compare the moisture durability performance of several design options. If the BSA deems the assembly’s performance unsatisfactory, it will provide the reasons why, and suggest necessary changes to wall design to ensure more robust performance.Using the BSA tool enables building designers to confidently select assembly design characteristics that achieve their design goals with the least moisture durability risk. Links to design-specific guidance are also be provided to help users manage any remaining risk. This tool will further enable DOE’s Building Technologies Office (BTO) to meet its long-term energy goal of a 50% reduction in building energy consumption by reducing builder concern about using highly energy efficient wall systems.

Desjarlais, Andre Omer↗

Evaluation of Thin Triple-Pane Windows in the PNNL Lab Homes

In recent years, improvements in glass manufacturing have allowed the production of thin triple-pane windows, which are manufactured with a thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy is sponsoring laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. To examine the performance of thin triple-pane windows, the Pacific Northwest National Laboratory (PNNL) evaluated the windows at the PNNL Lab Homes, a matched pair of homes located on PNNL’s campus in Richland, Washington. In this study, one Lab Home contained a complete set of nine thin triple-pane windows, while the other Lab Home contained baseline double-pane windows. The Lab Homes experiments demonstrated significant that replacing clear glass double-pane windows with thin triple-pane windows provided year-round energy savings and reduced peak demand both in the heating and cooling seasons. The Lab Homes experiments also validated other performance benefits of the thin triple-pane windows including reduced condensation potential, more even temperatures throughout the home and near the windows, and reduced sound attenuation through the windows, leaving the home quieter and more comfortable for the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evidence for Reduced Species Star Formation Rates in the Centers of Massive Galaxies at zeta = 4

We perform the first spatially-resolved stellar population study of galaxies in the early universe z equals 3.5 -6.5, utilizing the Hubble Space Telescope Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS) imaging dataset over the GOODS-S field. We select a sample of 418 bright and extended galaxies at z less than or approximately equal to 3.5-6.5 from a parent sample of approximately 8000 photometric-redshift selected galaxies from Finkelstein et al. We first examine galaxies at 3.5 less than or equal to z less than or approximately equal to 4.0 using additional deep K-band survey data from the HAWK-I UDS and GOODS Survey (HUGS) which covers the 4000 Angstrom break at these redshifts. We measure the stellar mass, star formation rate, and dust extinction for galaxy inner and outer regions via spatially-resolved spectral energy distribution fitting based on a Markov Chain Monte Carlo algorithm. By comparing specific star formation rates (sSFRs) between inner and outer parts of the galaxies we find that the majority of galaxies with the high central mass densities show evidence for a preferentially lower sSFR in their centers than in their outer regions, indicative of reduced sSFRs in their central regions. We also study galaxies at z approximately equal to 5 and 6 (here limited to high spatial resolution in the rest-frame ultraviolet only), finding that they show sSFRs which are generally independent of radial distance from the center of the galaxies. This indicates that stars are formed uniformly at all radii in massive galaxies at z approximately equal to 5-6, contrary tomassive galaxies at z. less than approximately equal to 4.

early universe – galaxies: bulges – galaxies: ↗

Thin Triples Expand the Affordable High-Performance Window Options For Retrofit

Sales of high-performance triple-pane windows make up only a small fraction (~3%) of total window sales in the United States with relatively stagnant market growth over the past 20 years. High costs have been the most commonly cited barrier to adoption. The emergence of thin triples that can fit into the glazing pocket of existing double pane windows has the potential to revolutionize the high-performance window market in particular the retrofit market by enabling glass only upgrades for situations where the frames are still in good condition. The retrofit market has other unique challenges not found in new construction that can be solved or reduced by thin triple pane windows. Insert replacements are often pursued instead of full frame replacement, in retrofits, this method reduces the net free area of a window and can turn an egress window into one that no longer meets the net free area requirements for egress. Thin frames minimize such occurrences. However, these thin frames can often not accommodate the weight of a traditional triple pane, thin triples can bring high performance to this situation. Thicker frames can also increase retrofit labor costs because the interior drywall and/or trim molding needs to be cut back to accommodate a thicker frame while thin triples can fit into frames that match the thickness of the existing window. This paper presents information about field test experiences the highlight these retrofit advantages from experiencing the challenges associated with retrofitting a thick frame as well as the supply chain, purchasability, material and labor costs, and real-world energy and non-energy performance associated with the IGU only replacement method.

window retrofits, thin triple-pane windows, high p↗