Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIGH-PURITY GE DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurement of Ionization Produced by 254 eVnr Nuclear Recoils in Germanium

Ionization produced by low-energy nuclear recoils is among the primary direct signatures of dark matter interactions. Despite the urgency of dark matter detection and the recent measurements of coherent elastic neutrino-nucleus scattering, detector response to nuclear recoils is not well characterized in the keVnr and sub-keVnr regime across a variety of materials. We have re-performed a measurement of the ionization produced by monoenergetic 254 eVnr nuclear recoils in Ge with improved digital electronics and additional systematic studies. Our results indicate an ionization yield of 64 +/- 8 eVee corresponding to a quenching factor of 25 +/- 3%, greater than the 14% predicted by the Lindhard model. This ionization enhancement could greatly improve the sensitivity of high-purity Ge detectors in dark matter detection and measurement of neutrinos via coherent scattering.

Kavner, Alexander R.↗

Rare multinucleon decays with the full data sets of the M AJORANA D EMONSTRATOR

The M AJORANA D EMONSTRATOR was an ultra-low-background experiment designed for neutrinoless double-beta decay (0⁢𝜈⁢𝛽⁢𝛽) investigation in 76 Ge . Located at the Sanford Underground Research Facility in Lead, South Dakota, the D EMONSTRATOR utilized modular high-purity Ge detector arrays within shielded vacuum cryostats, operating deep underground. The arrays, with a capacity of up to 40.4 kg (27.2 kg enriched to ∼88% in 76 Ge ), have accumulated the full data set, totaling 64.5 kg yr of enriched active exposure and 27.4 kg yr of exposure for natural detectors. Here, our updated search improves previously explored three-nucleon decay modes in Ge isotopes, setting new partial lifetime limits of 1.83 × 10 26 yr (90% confidence level) for 76 Ge (𝑝⁢𝑝⁢𝑝) → 73 Cu 𝑒 + ⁢𝜋 + ⁢𝜋 + and 76 Ge (𝑝⁢𝑝⁢𝑛) → 73 Zn 𝑒 + ⁢𝜋 + . The partial lifetime limit for the fully inclusive triproton decay mode of 76 Ge is found to be 2.1×10 25 yr. Furthermore, we have updated limits for corresponding multinucleon decays.

baryon & lepton number symmetries↗

Assay-based background projection for the Majorana Demonstrator using Monte Carlo uncertainty propagation

The background index (BI) is an important quantity to project and calculate the half-life sensitivity of neutrinoless double-𝛽 decay (0⁢𝜈⁢𝛽⁢𝛽) experiments. An analysis framework is presented to calculate the BI using the specific activities, masses, and simulated efficiencies of an experiments components as distributions. This Bayesian framework includes a unified approach to combine specific activities from assay. Monte Carlo uncertainty propagation is used to build a BI distribution from the specific activity, mass, and efficiency distributions. This method is applied to the M AJORANA D EMONSTRATOR , which deployed arrays of high-purity Ge detectors enriched in 76 Ge to search for 0⁢𝜈⁢𝛽⁢𝛽. The original assay-based projection is requantified in the new framework, using the as-built geometry of the Demonstrator and additional assay information. While 47% higher than the original projection, the resulting BI of [8.95±0.36]×10 −4 cts/(keVkgyr) from the 232 Th and 238 U decay chains does not account for the higher-than-expected BI observed by the D EMONSTRATOR . Finally, this method enables us to demonstrate the statistical incompatibility between the D EMONSTRATOR 's observed background and the assay results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Removing Spectral Diagnostics of Galactic and Stellar X-Ray Emission from Charged Exchange Recombination

Our research uses the electron beam ion trap (EBIT) at the Lawrence Livermore National Laboratory to study X-ray emission from the charge exchange (CX) of highly charged ions with neutral gases. The resulting data help to fill a void in existing experimental and theoretical understanding of this atomic physics process, and are needed to explain all or part of the observed X-ray emission from the soft X-ray background, stellar winds, the Galactic Center and Galactic Ridge, supernova ejecta, and photoionized nebulae. Appreciation of the astrophysical relevance of our work continues to grow with the publication of roughly a dozen papers in the past four years describing Chandra and XMM observations of geocoronal and heliospheric CX emission, the temporal variation of such emission and correlation with X-ray emission enhancements observed by ROSAT, the theoretical spatial distribution of that emission, and CX emission around other stars. A similar number of papers were also published during that time describing CX emission from planets and comets. We expect that the launch of ASTRSE2, with its second-generation XRS microcalo- (with 6-eV resolution), will reveal even more clearly the contributions of CX to astrophysical emission. In our EBIT work we collected CX spectra from such ions as H-like and He-like Ne, Ar, and Fe. Our early measurements were made with a high-purity Ge detector, but during the second year we began operation of the first-generation XRS microcalorimeter (a twin of the XRS on ASTRO-E) and greatly improved the resolution of our measurements from roughly 150 eV (FWHM) with the Ge detectors to 10 eV with the XRS. We found that saturation of the XRS counting apparatus, which we described in our proposal as a potential concern, is not a problem for studying CX. During the course of our research, we expanded the number of injection gases permitted by the LLNL safety team, purchased and eventually operated an atomic H source, and clearly demonstrated the feasibility of our longer-range plan. For example, we successfully injected He into EBIT (not a small feat because of the difficulty of maintaining a good vacuum with He and avoiding electrical breakdown) to collect a H-like oxygen CX spectrum. The highest energy CX spectrum recorded with the XRS to date is that of the Ar K-shell emission. These measurements provided the first observation of the relative intensity ratios of resolved He-like singlet and triplet n=2->1 lines. We also carried out measurements of He-like Ne as a function of collision energy (i.e., ion temperature). Significant differences in the resulting x-ray spectra were noted. In all cases, the intensity of high-n H-like Lyman lines is significantly higher than current theoretical CX models predict.

Wargelin, Brad↗

Neutron energy determination with a high-purity germanium detector

Two areas that are related to planetary gamma-ray spectrometry are investigated. The first task was the investigation of gamma rays produced by high-energy charged particles and their secondaries in planetary surfaces by means of thick target bombardments. The second task was the investigation of the effects of high-energy neutrons on gamma-ray spectral features obtained with high-purity Ge-detectors. For both tasks, as a function of the funding level, the experimental work was predominantly tied to that of other researchers, whenever there was an opportunity to participate in bombardment experiments at large or small accelerators for charged particles.

Beck, Gene A.↗

Doing photons with MERLIN 2 at Oroville

A very large n-type high-purity Ge-semiconductor detector has recently been installed in the Lawrence Berkeley Laboratory's underground low-background facility at Oroville. The detector (named MERLIN II) is mounted in a low-activity cryostat and has a rated 'efficiency' of about 115 percent -- nearly 4 times higher than our original MERLIN detector, which was used extensively to measure the minute amounts of radioactivity in samples from the LDEF satellite. We discuss gamma-spectrometric analyses with MERLIN II on some of the same LDEF samples, providing direct evidence for improvement in performance achieved with the larger detector.

Smith, Alan R.↗

Low-energy solar neutrino detection utilizing advanced germanium detectors

We explore the possibility to use advanced germanium (Ge) detectors as a low-energy solar neutrino observatory by means of neutrino-nucleus elastic scattering. A Ge detector utilizing internal charge amplification for the charge carriers created by the ionization of impurities is a novel technology with experimental sensitivity for detecting low-energy solar neutrinos. Ge internal charge amplification (GeICA) detectors will amplify the charge carriers induced by neutrino interacting with Ge atoms through the emission of phonons. It is those phonons that will create charge carriers through the ionization of impurities to achieve an extremely low energy threshold of ~0.01 eV. We demonstrate the phonon absorption, excitation, and ionization probability of impurities in a Ge detector with impurity levels of 3 × 10 10 cm -3 , 9 × 10 10 cm -3 , and 2 × 10 11 cm -3 . We present the sensitivity of such a Ge experiment for detecting solar neutrinos in the low-energy region. We show that, if GeICA technology becomes available, then a new opportunity arises to observe pp and 7 Be solar neutrinos. Such a novel detector with only 1 kg of high-purity Ge will give ~10 events per year for pp neutrinos and ~5 events per year for 7 Be neutrinos with a detection energy threshold of 0.01 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on the Decay of 180⁢𝑚 Ta

180m Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known β and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the Majorana Demonstrator, an experimental search for the neutrinoless double-beta decay of 76 Ge using an array of high-purity germanium detectors, to search for the decay of 180m Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background Majorana Demonstrator detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the 180m Ta half-life on the different decay channels. With new limits up to 1.5 × 10 19 years, we improved existing limits by one to two orders of magnitude. Furthermore, this result is the most sensitive search for a single β and electron capture decay ever achieved.

150 ≤ A ≤ 189↗

Results of the LEGEND-200 experiment in the search for $0νββ$ decay

The LEGEND experiment is looking for the extremely rare neutrinoless double beta (0νββ) decay of 76 Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the neutrino is a Majorana particle and the total lepton number would not be conserved, which could be related to the cosmological asymmetry between matter and antimatter through leptogenesis. The long-term goal of the collaboration is LEGEND-1000: a 1-ton detector array planned to run for 10 years, with a projected half-life sensitivity exceeding 10 28 years, fully covering the inverted neutrino mass hierarchy. A first search for the 0νββ decay has been carried out by LEGEND-200 building on the experience gained from GERDA and the MAJORANA DEMONSTRATOR. The experiment has been collecting physics data for a year at the Gran Sasso National Laboratory in Italy with 140 kg of HPGe detectors. With a total exposure of 61 kg yr, LEGEND-200 has achieved a background index of $5_{−2}^{+3}$ × 10 −4 counts/(keV kg yr) in the 0νββ decay signal region from the highest performing detectors. After combining the results from GERDA, the MAJORANA Demonstrator and LEGEND-200, an exclusion sensitivity > 2.8 × 10 26 yr has been obtained at 90% confidence level for the 0νββ decay half-life, with no evidence for a signal. A new observed lower limit of $T_{1/2}^{0v} >$ 1.9 × 10 26 yr at 90% confidence level has been established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and characterization of AmLi neutron sources for the LZ experiment

In this paper we describe the development, testing, and characterization of three low-emission rate AmLi neutron sources. The sources are used to calibrate the nuclear recoil response of the LUX-ZEPLIN (LZ) dark matter experiment. Furthermore, the sources' neutron emission rate was measured using 3He proportional tubes. The sources' gamma emissions were characterized using a high-purity germanium (HPGe) detector. Source-validated Geant4Monte Carlo simulations allowed to calibrate the Ge and neutron detectors' responses.

47 OTHER INSTRUMENTATION↗

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

Development of doped-germanium photoconductors for astronomical observations at wavelengths from 30 to 120 micrometers

Technology was developed for production of doped-germanium detectors which have optimized performance in the 30- to 120-micrometer wavelength range and are capable of achieving the objectives of the Infrared Astronomy Satellite space mission. The work of this phase was divided into the following major tasks: (1) growth of Ge:Ga crystals from high-purity starting material with Ga concentrations different from that previously produced, and development of a zone leveling method to produce a uniform Ga doping concentration; (2) growth of uncompensated Ge:Be crystals from high-purity starting material with a range of Be concentrations between 10 to the 14th power and 10 to the 16th power atoms/cubic cm; (3) evaluation of crystals by means of Hall effect and resistance measurements as a function of temperature; (4) fabrication and test of detectors made from both Ge:Be and Ge:Ga crystals to determine the relative performance between different crystals. Correlation of detector test data with material evaluation data and analysis of how to further optimize detector performance.

Bratt, P. R.↗

Machine learning-powered data cleaning for LEGEND: a semi-supervised approach using affinity propagation and support vector machines

Neutrinoless double-beta decay ($0\nu\beta\beta$) is a rare nuclear process that, if observed, will provide insight into the nature of neutrinos and help explain the matter-antimatter asymmetry in the Universe. The large enriched germanium experiment for neutrinoless double-beta decay (LEGEND) will operate in two phases to search for $0\nu\beta\beta$. The first (second) stage will employ 200 (1000) kg of High-Purity Germanium (HPGe) enriched in 76 Ge to achieve a half-life sensitivity of 10 27 (10 28 ) years. In this study, we present a semi-supervised data-driven approach to remove non-physical events captured by HPGe detectors powered by a novel artificial intelligence model. We utilize affinity propagation to cluster waveform signals based on their shape and a support vector machine to classify them into different categories. We train, optimize, and test our model on data taken from a natural abundance HPGe detector installed in the Full Chain Test experimental stand at the University of North Carolina at Chapel Hill. We demonstrate that our model yields a maximum sacrifice of physics events of $0.024 ^{+0.004}_{-0.003} \%$ after data cleaning. Our model is being used to accelerate data cleaning development for LEGEND-200 and will serve to improve data cleaning procedures for LEGEND-1000.

artificial intelligence↗

Charge trapping correction and energy performance of the Majorana Demonstrator

P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the Majorana Demonstrator, a neutrinoless double-β decay experiment deploying PPC detectors enriched in 76 Ge, has led to several novel improvements in the analysis of PPC signals. Here, in this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal, and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the Majorana Demonstrator by approximately 30 % to around 2.4 keV full width at half-maximum at 2039 keV, the 76 Ge Q value. An alternative approach achieving similar resolution enhancement is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exotic Dark Matter Search with the Majorana Demonstrator

With excellent energy resolution and ultralow-level radiogenic backgrounds, the high-purity germanium detectors in the enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos ν s → ν a . We report new limits on fermionic dark matter absorption ( χ + A → ν + A ) and sub-GeV DM-nucleus 3 → 2 scattering ( χ + χ + A → ϕ + A ), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the (1–100)-keV low-energy region of a 37.5-kg y exposure collected by the between May 2016 and November 2019 using a set of Ge 76 -enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

First-Principles insights into group-V impurities and their impact on germanium detector performance

The outstanding properties of high-purity germanium (HPGe) detectors, such as excellent energy resolution, high energy sensitivity, and a low background-to-signal ratio, make them essential and ideal candidates for detecting particle signatures in nuclear processes such as neutrino-less double beta decay (0νββ). However, the presence of defects and impurities in HPGe crystals can lead to charge trapping, which affects carrier mobility and results in significant energy resolution degradation. In this work, we employ density functional theory with a hybrid functional to study the energetics of possible point defects in Ge. Our findings indicate that group-V impurities form more readily in Ge compared to vacancy and interstitial of Ge. Unlike N dopants, which yield deep trap states, P, As, and Sb create shallow traps close to the conduction band edge of Ge. Furthermore, we predict that group-V defects can condense into defect complexes with Ge vacancies. These vacancy-impurity complexes form deep traps in Ge, similar to Ge vacancies, suggesting that both vacancies and vacancy-impurity complexes contribute to charge trapping in these detectors, thereby diminishing their performance.

36 MATERIALS SCIENCE↗