Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIGH SPEED CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

Errors in particle tracking velocimetry with high-speed cameras

Velocity errors in particle tracking velocimetry (PTV) are studied. When using high-speed video cameras, the velocity error may increase at a high camera frame rate. This increase in velocity error is due to particle-position uncertainty, which is one of the two sources of velocity errors studied here. The other source of error is particle acceleration, which has the opposite trend of diminishing at higher frame rates. Both kinds of errors can propagate into quantities calculated from velocity, such as the kinetic temperature of particles or correlation functions. As demonstrated in a dusty plasma experiment, the kinetic temperature of particles has no unique value when measured using PTV, but depends on the sampling time interval or frame rate. It is also shown that an artifact appears in an autocorrelation function computed from particle positions and velocities, and it becomes more severe when a small sampling-time interval is used. Schemes to reduce these errors are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invited Article: Quantitative imaging of explosions with high-speed cameras

Here, the techniques presented in this paper allow for mapping of temperature, pressure, chemical species, and energy deposition during and following detonations of explosives, using high speed cameras as the main diagnostic tool. Additionally, this work provides measurement in the explosive near to far-field (0-500 charge diameters) of surface temperatures, peak air-shock pressures, some chemical species signatures, shock energy deposition, and air shock formation.

47 OTHER INSTRUMENTATION↗

Measurement of inkjet first-drop behavior using a high-speed camera

Drop-on-demand inkjet printing has been used as a manufacturing tool for printed electronics, and it has several advantages since a droplet of an exact amount can be deposited on an exact location. Such technology requires positioning the inkjet head on the printing location without jetting, so a jetting pause (non-jetting) idle time is required. Nevertheless, the behavior of the first few drops after the non-jetting pause time is well known to be possibly different from that which occurs in the steady state. The abnormal behavior of the first few drops may result in serious problems regarding printing quality. Therefore, a proper evaluation of a first-droplet failure has become important for the inkjet industry. To this end, in this study, we propose the use of a high-speed camera to evaluate first-drop dissimilarity. For this purpose, the image acquisition frame rate was determined to be an integer multiple of the jetting frequency, and in this manner, we can directly compare the droplet locations of each drop in order to characterize the first-drop behavior. Finally, we evaluate the effect of a sub-driving voltage during the non-jetting pause time to effectively suppress the first-drop dissimilarity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MHD mode tracking using high-speed cameras and deep learning

Abstract We present a new algorithm to track the amplitude and phase of rotating magnetohydrodynamic (MHD) modes in tokamak plasmas using high speed imaging cameras and deep learning. This algorithm uses a convolutional neural network (CNN) to predict the amplitudes of the n = 1 sine and cosine mode components using solely optical measurements from one or more cameras. The model was trained and tested on an experimental dataset consisting of camera frame images and magnetic-based mode measurements from the High Beta Tokamak - Extended Pulse (HBT-EP) device, and it outperformed other, more conventional, algorithms using identical image inputs. The effect of different input data streams on the accuracy of the model’s predictions is also explored, including using a temporal frame stack or images from two cameras viewing different toroidal regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large Area Divertor Temperature Measurements Using A High-speed Camera With Near-infrared FiIters in NSTX

Fast cameras already installed on the National Spherical Torus Experiment (NSTX) have be equipped with near-infrared (NIR) filters in order to measure the surface temperature in the lower divertor region. Such a system provides a unique combination of high speed (> 50 kHz) and wide fi eld-of-view (> 50% of the divertor). Benchtop calibrations demonstrated the system's ability to measure thermal emission down to 330 oC. There is also, however, signi cant plasma light background in NSTX. Without improvements in background reduction, the current system is incapable of measuring signals below the background equivalent temperature (600 - 700 oC). Thermal signatures have been detected in cases of extreme divertor heating. It is observed that the divertor can reach temperatures around 800 oC when high harmonic fast wave (HHFW) heating is used. These temperature profiles were fi t using a simple heat diffusion code, providing a measurement of the heat flux to the divertor. Comparisons to other infrared thermography systems on NSTX are made.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High speed infrared camera diagnostic for heat flux measurement in NSTX

A new high speed infrared camera has been successfully implemented and produced first set of heat flux measurements on the lower divertor tiles in the NSTX tokamak. High spatial and temporal resolutions, 6.4 mm and 1.6-6.3 kHz, respectively, enable us to investigate detailed structure of heat flux deposition pattern caused by transient events such as edge localized modes. A comparison of the data with a slow infrared camera viewing the same region of interest shows good agreement between the two independent measurements. Data analysis for various plasma conditions is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed CMOS camera

A high-speed CMOS camera includes an array of pixel circuits coupled to a photodiode array, an oscillator circuit, and a pattern generator circuit. The pattern generator circuit includes a high speed shift register and a non-overlap generator. The shift register is programmable to produce a pulse train of trigger pulses that defines an interframe and a frame's shutter duration. The non-overlap generator deserializes the incoming pulse train of trigger pulses, and it produces a time-separated reset pulse based on the pulse train of trigger pulses. The shift register is configured to permit the frame durations and the interframe times to be selected arbitrarily over specified ranges in increments of a basic time unit that depends on the oscillator period.

42 ENGINEERING↗

Electrically conductive carbon fiber layers as lightning strike protection for non-conductive epoxy-based CFRP substrate

A large amount of electrically conductive fillers is needed to enhance a Carbon Fiber Reinforced Plastics (CFRP) electrical conductivity enough to withstand lightning strikes of peak currents. However, such large alien constituents hamper the inherent good mechanical properties of CFRP structures. In this work, a solution has been proposed to retain both desired properties in a CFRP laminate. Layer-wise hybrid laminate has been demonstrated as a solution for lightning strike protection of Carbon Fiber Reinforced Plastics (CFRP). Top few layers of a hybrid laminate are prepared using electrically conductive polymer-based resin (CF/C-POLY) to provide effective dissipation of lightning current while epoxy-based CFRP substrate (CF/Epoxy) provides the main structural strength. An insulating adhesive layer is used to bond CF/C-POLY and CF/Epoxy to prepare the laminate. The hybrid laminates were tested for their effectiveness against lightning strikes. Laminates were struck by modified lightning waveform of component A with peak current of -14 kA and -40 kA. The performance of the laminates against lightning strike were evaluated using high speed camera, high-speed and thermal camera. It is found that CF/C-POLY layer successfully defended the main structural component i.e. CF/Epoxy from lightning direct damage.

36 MATERIALS SCIENCE↗

Measuring 8–250 ps short pulses using a high-speed streak camera on kilojoule, petawatt-class laser systems

Short-pulse measurements using a streak camera are sensitive to space-charge broadening, which depends on the pulse duration and shape, and on the uniformity of photocathode illumination. An anamorphic-diffuser-based beam-homogenizing system and a space-charge-broadening calibration method were developed to accurately measure short pulses using an optical streak camera. This approach provides a more-uniform streak image and enables one to characterize space-charge-induced pulse-broadening effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance comparison of state-of-the-art high-speed video cameras for scientific applications

Time-resolved visualization of fast processes using high-speed digital video-cameras has been widely used in most fields of scientific research for over a decade. In many applications, high-speed imaging is used not only to record the time history of a phenomenon but also to quantify it, hence requiring dependable equipment. Important aspects of two-dimensional imaging instrumentation used to qualitatively or quantitatively assess fast-moving scenes include sensitivity, linearity, as well as signal-to-noise ratio (SNR). Under certain circumstances, the weaknesses of commercially available high-speed cameras, i.e., sensitivity, linearity, image lag, etc., render the experiment complicated and uncertain. Our study evaluated two advanced CMOS-based, continuous-recording, high-speed cameras available at the moment of writing. In this work, various parameters, potentially important toward accurate time-resolved measurements and photonic quantification, have been measured under controlled conditions on the bench, using scientific instrumentation. Testing procedures to measure sensitivity, linearity, SNR, shutter accuracy, and image lag are proposed and detailed. The results of the tests, comparing the two high-speed cameras under study, are also presented and discussed. Results show that, with careful implementation and understanding of their performance and limitations, these high-speed cameras are reasonable alternatives to scientific CCD cameras, while also delivering time-resolved imaging data.

42 ENGINEERING↗

TH-CD-201-10: Highly Efficient Synchronized High-Speed Scintillation Camera System for Measuring Proton Range, SOBP and Dose Distributions in a 2D-Plane

Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range and SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal.

07 ISOTOPE AND RADIATION SOURCES↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗