Engineering PapersSearch

SEARCH · Engineering Papers

Results for “HGMF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

High-gradient magnetic filtration of UO 2 colloids from aqueous suspensions

Environmental samples often contain innocuous components that make trace actinide analysis difficult and expensive. Therefore, it is expedient to separate these materials from actinide particles. One characteristic of many actinides is that they are paramagnetic. High-gradient magnetic filtration (HGMF) is a non-destructive technique that selectively captures magnetic constituents from a matrix containing non-magnetic species. Here, in this work, a novel HGMF device made of a permanent magnet array was used to effectively separate UO 2 particles from undesirable soil species. Up to 88% of the UO 2 particles present in suspensions were effectively captured by HGMF, resulting in their enrichment and a substantial reduction in the concentrations of other constituents.

Actinide separations

Selective capture and recovery of uranium oxide colloids from aqueous soil suspensions using high gradient magnetic filtration

High Gradient Magnetic Filtration (HGMF) is a promising method for the selective capture and recovery of uranium oxide from surface soils. To date, however, magnetic filtration of uranium oxide has only been demonstrated at a proof-of-principle scale using relatively small filters (<5 cm 3 ) at low flowrates (<60 mL/min). Here, to explore the efficacy of magnetic filtration of uranium oxide at a larger scale, a newly designed HGMF apparatus that is more than an order of magnitude larger than our earlier filters (106 cm 3 ) was designed, fabricated, and tested at relatively high flowrates. Filtration experiments were performed using aqueous uranium oxide particle suspensions with Arizona Road Dust (ARD) as a soil simulant. At a flowrate of 125 mL/min, the apparatus’ uranium capture rate was exceptionally high (96 %), but selectivity was poor due to the high rate of capture for diamagnetic soil constituents (e.g., 77 % for silicon). All particles were captured at a lower rate when the flowrate was increased to 250 mL/min, but uranium selectivity was significantly increased due to the more substantial reduction in diamagnetic particle capture (i.e., capture rate of 77 % and 15 % for uranium and silicon, respectively). When backwashing the apparatus at the same flowrates used during filtration experiments, the rate of uranium recovery tended to be fairly low. Nevertheless, higher flowrates (1 L/min) and sonication were both shown to be highly effective methods of increasing uranium recovery. Magnetic field simulations were also performed to investigate potential optimizations to the design of the apparatus. These simulations showed that the intensity of the applied magnetic field could be increased by increasing the thickness of the steel magnetic housing. Additionally, stochastic trajectory simulations were performed to investigate the potential mechanisms of particle capture.

HGMF