Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEPA Filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Full Scale HEPA Filter Encapsulation in Ultra-High-Performance Grout - Proof of Concept

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) currently being constructed to treat radioactive waste, includes vitrification facilities for both the high-level waste (HLW) and low activity waste (LAW) fractions. Operation of the WTP will produce contaminated high-efficiency particulate air filters (HEPA), as part of the solid secondary waste (SSW) stream. The HEPA filters receive off-gas from the vessel vent header and primary off-gas treatment system in LAW Facility and remove particulate contaminants including 99 Tc and 129 I salts. The current disposal method for HEPA filters is encapsulation in metal containers using cementitious material (CM) and disposal in the Integrated Disposal Facility (IDF). Results from the 2017 IDF Performance Assessment (PA) WRPS (2018) demonstrated that while compliance is maintained for the 1000 year compliance period mandated by DOE O 435.1 and its accompanying manual, release of constituents from the HEPA filters result in exceedance of the performance objective imposed as the groundwater regulatory limit at later times. For example, at about 1500 years post-closure, solid secondary waste (SSW), including HEPA filters is predicted to become a dominant contributor to 99 Tc release and over the 10,000-year sensitivity analysis period, SSW is the dominant contributor of 129 I release to the groundwater. The estimated release could potentially be reduced if the HEPA filters are not compacted and waste containers could be distributed throughout a large space, thereby diluting the contaminant release. Additionally, a better cementitious material could be used to encapsulate the HEPA filters. One alternative method for disposal of contaminated HEPA filters is encapsulation of the filters in ultra high-performance grout (UHPG). UHPG is a variation of ultra-high-performance concrete (UHPC) is commonly used in the prestressed concrete industry for large structural members. Recent studies of UHPG show it has excellent properties for containing radionuclides such as 99 Tc and 129 I Nichols and Kaplan (2021). This report presents the results of the first attempt to encapsulate a clean, full-size HEPA filter in UHPG and evaluate the effectiveness of the immobilization process and final waste form. A full-scale proof-of-concept simulated waste form was prepared by encapsulating a HEPA filter in a 110-gallon stainless steel (SS) drum using UHPG. A change from Type I/II PC to Type 1L PLC was made after American Rock Products informed the team that they would no longer be using Type I/II by the end of 2024 and the northwest was phasing out Type I/II PC overall. Type I/II PC used in previous studies of UHPG for encapsulation (Nichols and Kaplan 2021). After the UHPG was cured both the scaled mockup and the full-scale simulated waste forms were sectioned for visual examination. UHPG completely encapsulated the filters and bonded to the external surfaces of materials comprising the filters. No cracks were observed in the sectioned waste forms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Treatment Procedure for a Volume Reduction of the Spent HEPA Filters in KAERI

Spent filter wastes of about 2,200 units have been stored in the radioactive waste storage facility of the Korea Atomic Energy Research Institute since its operation. Among these spent filter wastes, a HEPA filter account for about 95 %. All these HEPA filter wastes generated at KAERI have been stored inside a poly bag in accordance with the original form without any treatment of them. Therefore, in order to secure a space in a radioactive waste storage facility approaching its saturation, it is necessary to treat them by a compaction in view of a radioactive waste treatment and storage, and finally to repack the compacted spent filters into a regular drum for sending them to a final disposal site. To do that, the spent HEPA filter wastes were classified according to their generation facility, their generation date and their surface dose rate by investigating the inventory of them. And also, a nuclide assessment of them was conducted by taking a representative sample at the spot of a high dose rate at the intake surface and the outlet surface of a spent HEPA filter without a dismantlement, before compacting them. At present, for the spent HEPA filter wastes after a radionuclide assessment, a compaction treatment of them is now being conducted by using the shaping and compacting equipment developed at KAERI. Thus, to put a HEPA filter with a hexahedral form of a 610(W) x 610(H) x 305(T) mm into a regular drum (DOT-17H) with an inner diameter of about 572 mm, a columnar shaping with a capacity of 15 tons was conducted. From this shaping, a shaped HEPA filter waste with a diameter of about 500 mm was directly put into a regular drum. And then, the compaction treatment of a shaped HEPA filter with a capacity of about 60 tons was conducted by vertically compacting it. As a result, a volume reduction rate of a spent HEPA filter waste by a shaping and compacting of it accounted for about 1/8 when compared to its original form. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Interim Status of HEPA Filter 10-Year Lifetime Evaluation

High efficiency particulate air (HEPA) filters are used to remove a variety of particles from industrial gas streams. HEPA filters remove at least 99.97% of airborne particles 0.3 microns in diameter, while particles smaller or larger than 0.3 microns are removed with an even higher efficiency. The purpose of this study is to draw a relationship between the HEPA filter lifespan and various competing factors that include the differential pressure drop in nuclear grade HEPA filters, the fume hood face velocity, the radiological dose, and the filter efficiency characteristics. The Department of Energy (DOE) uses a conservative interpretation of data to set the age limit of HEPA filters at 10 years (DOE-HDBK-1169-2003). The lifetime was determined by an analysis of multiple HEPA filter research studies, performed by Bergman at the Lawrence Livermore National Laboratory (LLNL). Analysis of data from Robinson et al. suggests that unfolded media tensile strength fail at 13 years, while folded media do not have the required 2.5 pound/inch tensile strength even when new and is extremely low at 7 years. Therefore, the data displayed failed tensile strength and low burst strengths at an average of 10 years. Although filter life was difficult to estimate using the data, based on the relationship between HEPA filter and their age, the recommended lifetime was set at 10 years under dry conditions (Bergman 1999). Effluent Management (EM) is coordinating a 10-year effort to collect and analyze the lifetime of HEPA filters against the other competing requirements. The study began in 2010 and consists of 49 HEPA filters that are analyzed annually to verify compliance with permit conditions. The data are collected from the Physical Science Facility (PSF) 3410, 3420, and 3430 buildings located at the Pacific Northwest National Laboratory (PNNL). The study suggests the frequency of filter replacement should also be based on the differential pressure, filter efficiency, and/or face velocity of the fume hood, rather than a prescribed filter “lifetime”, which is currently every 10 years from the date of manufacture for filters operating under dry conditions. Over the past six years, only two filters in the study were replaced: one due to high DP and low fume hood face velocity, and the other due to low filter efficiency results.

54 ENVIRONMENTAL SCIENCES↗

HEPA Filter Age Evaluation Report

In 2020, PNNL completed a literature search for high-efficiency particulate air (HEPA) filter age information. HEPA filters are used in many operations to remove particulate matter from effluent exhaust streams. They are thought to degrade over time both during proper storage and during normal operational service; however, the rate at which the filters degrade remains unknown. This brings into question if age is an adequate indicator of HEPA filter performance. Data from six previous reports were obtained from the literature search and combined to create a data set of 1600 operating filters. Filter usage was identified from multiple facilities. The various types of filters (e.g., axial flow, self-contained, and standard 24 x 24 x 11.5 inches; and both separator and separatorless) reported were constructed to the requirements Section FC (HEPA Filters) or Section FK (Special HEPA Filters) of the American Society of Mechanical Engineers AG-1 code. Filters were presumed to have continuously met the operational criteria and in particular passed both annual efficiency tests and annual DP measurements. The environmental conditions within the exhaust system were also assumed adequate for long-term filter operation. The data, by the nature of the reports, excludes rejected filters from quality assurance evaluations, intake, or installation testing. The collective data set shows over half of were operating past the current 10-year Department of Energy (DOE) limit. Data was evaluated for age lifetime using a linear trendline, survival function, probability functions, and failure rate; financial impacts were also addressed. This report supports the notion that HEPA filters can operate safely and efficiently under proper maintenance well past the 10-year lifetime established by DOE. Using the results of the four age evaluation approaches, they collectively point to the reasonableness of an operating HEPA filter lifetime of 20 years. The results are not necessarily definitive, but nevertheless, they are promising. The analysis provides reasonable assurance that when implemented using a graded approach with well-defined performance and operational requirements, extending the service life for HEPA filters beyond 10 years is low risk.

42 ENGINEERING↗

Evaluating the Performance Envelope of Axial Flow HEPA Filter Designs - 17466

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the Department of Energy National Nuclear Security Administration (DOE/NNSA) complex. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels and conditions that fibrous glass HEPA filters can handle. Axial Flow filters can be purchased with physical separators or embossed medium to maintain proper pleat geometry. Separator-less designs use media embossed with a corrugation pattern to retain pleat geometry. At least some versions of the separator-less filter packs have demonstrated unexpected and rapid failure under slightly elevated temperature and humidity conditions. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. Mississippi State University is conducting studies to more clearly identify the operating envelope of separator and separator-less designs of ASME AG-1 Section FC axial flow HEPA filters under a set of generic design basis conditions. A parallel study is also being conducted to evaluate the effects of age on fibrous glass HEPA filters. Activities described in this paper have been conducted under Institute for Clean Energy Technology (ICET's) NQA-1 nuclear quality assurance program approved by DOE-EM. Testing meets the requirements of EM Quality Assurance Program (QAP) EM-QA-001, Rev. 1, June 11, 2012 that includes the applicable requirements of NQA-1-2008/2009a and DOE Order 414.1D. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Ceramic High Efficiency Particulate Air (HEPA) Filter (Final Report)

The technical objective of this project was to develop a ceramic HEPA filter technology, by initially producing and testing coupon ceramics, small scale prototypes, and full scale prototype HEPA filters, and to address relevant manufacturing and commercialization technical issues. The deliverable of the project would be a ceramic HEPA filter technology meeting the specifications of existing, glass fiber, nuclear grade HEPA systems. The existing HEPA filters are made from glass fiber, which is fragile and easily damaged due to impact by chemicals, high pressures and temperatures (see photographs in Fig. 1). A ceramic HEPA filter technology would overcome these problems and would allow the filter to be cleaned and reused, thereby reducing secondary waste. Additionally, ceramic HEPA filters will eliminate the associated costs and risks of contamination posed by "hot breaks" - the breaching of containment - required to periodically replace HEPA filters of current design. The ceramic HEPA filter technology would be designed to minimize retrofit problems and costs while meeting several key HEPA filter requirements.

36 MATERIALS SCIENCE↗

Interim Status of HEPA Filter 10-Year Lifetime Evaluation

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifespan and its other performance indicators. The 10-year-long endeavor to collect and analyze data regarding the lifetime of HEPA filters at the Pacific Northwest National Laboratory began in 2019. Forty-nine HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. Over the past nine years, only four HEPA filters have been replaced for technical issues.

54 ENVIRONMENTAL SCIENCES↗

Final Status of HEPA Filter 10-Year Lifetime Evaluation

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifespan and its other performance indicators. The 10-year-long endeavor to collect and analyze data regarding the lifetime of HEPA filters at the Pacific Northwest National Laboratory began in 2010. Forty-nine HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. Over the past decade, the study has now been completed, and all forty-nine HEPA filters have been replaced, due to either technical issues listed in this report, or the previously recommended filter “age limit” of 10 years.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of AG-1 FC HEPA Filters and Medium in Nuclear Complex Facilities - 20434

High Efficiency Particulate Air (HEPA) filters are credited as the final barrier against the release of radioactive aerosol contamination in nearly every operating U. S. Department of Energy (DOE) and National Nuclear Security Agency (NNSA) nuclear facility. The Institute for Clean Energy Technology (ICET) at Mississippi State University maintains a research program that studies various aspects of these components of containment systems and seeks to answer key questions from across the industry. This programmatic overview will include results from recent and ongoing studies, including a study on filter design and performance envelope, degradation due to aging or fatigue, fire event impact on HEPA filters, and accelerated aging of medium and component parts. ICET has completed a study helping to define the threshold for combined elevated temperature and relative humidity resistance of separator style and separator-less style HEPA filters that are used in DOE complexes. The study provides experimental data that considers elevated temperature, elevated relative humidity (RH), and target differential pressure (dP) in an attempt to gain a better understanding or more comprehensive insight into the operating envelope of different configurations of ASME (American Society for Mechanical Engineers) AG-1 Section FC filters. Test variables including air temperature ranges of 48.88 deg. C, 54.44 deg. C, or 60 deg. C (120, 130, or 140 deg. F); air RH ranges including 60-70%, 80%, or 90+% with initial filter dP of either 497.68 Pa, 746.52 Pa, or 995.36 Pa (2 inches water column (in. w. c.), 3 in. w. c., or 4 in. w. c.) included for full bracketing of each set of conditions. A study examining the effects of aging and fatigue on nuclear grade HEPA filters and medium elucidates the physical properties of media along with testing of new and aged ASME AG-1 HEPA filters. In addition to performing autopsies of the tested, aged filters to help better understand the service life of their performance, newly designed accelerated aging chambers allow new medium to undergo accelerated aging and exposure treatments. Evaluation of degradation in physical properties and functionality requires a high population of aged filters of different ages, designs, manufacturers, and operational histories. The limited availability of this population and the impropriety of looking solely at formulations and components from past years requires experimental design that will provide foresight into future filter performance. This undertaking therefore involves not only properties analysis of aged medium from different operational histories, ages, designs, and manufacturers, but also prescience in analytical goals via accelerated aging studies of newly manufactured media. A more complete understanding of the mechanisms of degradation from past formulations as well as current and future formulations is possible. Accelerated Aging of newly manufactured media utilizes exposure treatments based on the Arrhenius equation to artificially age medium and therefore glimpse into the future. Evaluation of current media properties This testing allows for the comparison of performance and durability of new filters under upset or design basis conditions with aged filters that were in service under ambient conditions and other aged filters retained in storage. Susceptibility of HEPA filters to the effects of combustion byproducts, heat, and water is also being studied in an attempt to gain understanding on the prevention of filter failures during fire events in nuclear facilities. ICET seeks to determine the effect of filter performance due to smoke loading using characterized smoke from variable fuel compositions, geometries, and loads; the smoke capacity of various filters with different burning conditions, heat release rates and transport, as well as mass transport from the air stream will be studied in low flow containment systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiological HEPA Filter 10-year Lifetime Evaluation in Research Facilities

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifetime deployment and its other performance indicators. This 10-year-long endeavor to collect and analyze data regarding the service life of HEPA filters at the Pacific Northwest National Laboratory began in 2010. A set of HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. The study has now been completed, and over the past decade all the HEPA filters have been replaced, due to either technical issues as listed in this report or the previously recommended filter “age limit” of 10 years as prescribed by the oversight bodies. Experimentally determined failure rates are also determined from the data set and can be used to estimate the chances of HEPA filters surviving 15, 20, or even 30 years.

61 RADIATION PROTECTION AND DOSIMETRY↗

Define and Quantify the Physics of Air Flow, Pressure Drop and Aerosol Collection in Nuclear Grade HEPA Filters

Objective: Develop a set of peer-review and verified analytical methods to adjust HEPA filter performance to different flow rates, temperatures and altitudes. Experimental testing will measure HEPA filter flow rate, pressure drop and efficiency to verify the analytical approach. Nuclear facilities utilize HEPA (High Efficiency Particulate Air) filters to purify air flow for workspace ventilation. However, the ASME AG-1 technical standard (Code on Nuclear Air and Gas Treatment) does not adequately describe air flow measurement units for HEPA filter systems. Specifically, the AG-1 standard does not differentiate between volumetric air flow in ACFM (actual cubic feet per minute)compared to mass flow measured in SCFM (standard cubic feet per minute). More importantly, the AG-1 standard has an overall deficiency for using HEPA filter devices at different air flow rates, temperatures, and altitudes. Technical Approach: The collection efficiency and pressure drops of 18 different HEPA filters will be measured over a range of flow rates, temperatures and altitudes. The experimental results will be compared to analytical scoping calculations. Three manufacturers have allocated six HEPA filters each for this effort. The 18 filters will be tested at two different flow rates, two different temperatures and two different altitudes. The 36 total tests will be conducted at two different facilities: the ATI Test facilities (Baltimore MD) and the Los Alamos National Laboratory (Los Alamos NM). The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally designed to evaluate small air samplers. In 2010, modifications were started to convert the wind tunnel for HEPA filter testing. (Extensive changes were necessary for the required aerosol generators, HEPA test fixtures, temperature control devices and measurement capabilities.) To this date, none of these modification activities have been funded through a specific DOE or NNSA program. This is expected to require six months of time, after receipt of funding. Benefits: US DOE facilities that use HEPA filters will benefit from access to the new operational measurement methods. Uncertainty and guesswork will be removed from HEPA filter operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

LLNL HEPA Filter Support of Nuclear Facility Safety R&D (FY12)

The ceramic HEPA filter project has been a successful and innovative project. This report contains information from the work from FY12 funding, as well as remaining FY11 funding. Of note, a total of 12 patents for the ceramic HEPA filter program have been filed, and an additional record of invention has been prepared with a provisional patent to follow. This project supports development of a ceramic HEPA filter technology to benefit DOE nuclear facilities by providing lower life-cycle costs and reducing or eliminating costs associated with Safety Class and Safety Significant systems in nuclear facilities. The satisfactory performance of ceramic filters in a fire could significantly reduce costs of support systems associated with mitigating a release, such as fire suppression, fire detection and alarm, and internal building structure. In nuclear safety, the best way to provide protection to public, workers and the environment is to provide a barrier between the hazard and the receptors. A passive engineered design feature is the best barrier for that purpose. Advanced ceramic HEPA filters provide an excellent barrier between radioactive material in a nuclear facility and everything downwind. Both university (Cal Poly) student teams did very well. As summarized in this report, they successfully added and upgraded instrumentation and controls to the High Temperature Test Unit (HTTU) for the ceramic filter project. They also succeeded in adding viewing ports, remotely controlled closed circuit television, a flame impingement system and a helium filter gasket leak detection system. Details can be found in Ref. 3 - 6. The HTTU has flexible capabilities and can also be used to test other types of filters or filter components in the future, if so desired. At LLNL, research to improve filter media coating (Fig. 1) is being conducted to maintain filtration efficiency while improving performance (reducing pressure drop). Improvements in the individual filter element are necessary to maintain filtration efficiency while decreasing pressure drop. The path forward for an optimal ceramic HEPA filter meeting DOE’s needs is to improve the filtration media. This task utilized the LLNL/DOE developed innovations along with progress in previous activities to prepare multiple ceramic filter elements and refine the technical details for depositing advanced filtration materials to the ceramic filter to meet desired filter performance. The ceramics filter elements were tested for pressure drop at the required air flow rate using an air flow test system. The filtration efficiency and pressure drop of the ceramic filter elements will be measured as part of the development process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prototype Ceramic HEPA Filter Testing and Filter Media Research and Development for Nuclear Facility Ventilation

This is a brief summary of recent and past Ceramic HEPA Filter research and development activities under an NNSA NSR&D funded project and describes on-going plans for FY19 work as presently planned. Prior work has evaluated concepts for a ceramic HEPA filter including ceramic support materials, filter media including electrospun filter media, and metal housing designs to accommodate the conservative temperature performance target of up to 500°C. This has been supported by modelling efforts discussed with nuclear facility system engineers and their management. The temperature and time-attemperature are based on conservative, bounding temperatures from fire analysis presented as an EFCOG best practice paper for nuclear facility safety analysis. The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology including increasing temperature performance while maintaining acceptable filter pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases. The goal of the ceramic HEPA filter is to provide a HEPA filter that provides increased temperature performance in an equivalent form factor (size and shape) that is similar to existing conventional HEPA filters used in facilities. Once development is complete and qualified for use in facilities, ceramic HEPA filters could simplify and reduce safety and support system costs, as well as lower life-cycle costs. Installation, monitoring, and maintenance of active fire suppression systems, as well as other related systems, are a considerable on-going cost to nuclear facilities. Reducing the level of dependence on Safety Class and Safety Significant fire alarm and fire suppression systems could allow significant cost savings. At present we are continuing research and development efforts towards the goal of a ceramic filter design, including improved ceramic filter media, that could reduce total operation cost for facilities utilizing HEPA filters.

36 MATERIALS SCIENCE↗

Prototype Ceramic HEPA Filter Testing and Filter Media Research and Development for Nuclear Facility Ventilation

This is a brief summary of recent and past Ceramic HEPA Filter research and development activities under an NNSA NSR&D funded project and describes on-going plans for FY19 work as presently planned. Prior work has evaluated concepts for a ceramic HEPA filter including ceramic support materials, filter media including electrospun filter media, and metal housing designs to accommodate the conservative temperature performance target of up to 500°C. This has been supported by modelling efforts discussed with nuclear facility system engineers and their management. The temperature and time-at-temperature are based on conservative, bounding temperatures from fire analysis presented as an EFCOG best practice paper for nuclear facility safety analysis. The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology including increasing temperature performance while maintaining acceptable filter pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases. The goal of the ceramic HEPA filter is to provide a HEPA filter that provides increased temperature performance in an equivalent form factor (size and shape) that is similar to existing conventional HEPA filters used in facilities. Once development is complete and qualified for use in facilities, ceramic HEPA filters could simplify and reduce safety and support system costs, as well as lower life-cycle costs. Installation, monitoring, and maintenance of active fire suppression systems, as well as other related systems, are a considerable on-going cost to nuclear facilities. Reducing the level of dependence on Safety Class and Safety Significant fire alarm and fire suppression systems could allow significant cost savings, while maintaining safety. At present we are continuing research and development efforts towards the goal of a ceramic filter design, including improved ceramic filter media, that could reduce total operation cost for facilities utilizing HEPA filters.

36 MATERIALS SCIENCE↗