Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELIUM 5”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hot HB Stars in Globular Clusters: Physical Parameters and Consequences for Theory: Radiative Levitation Versus Helium Mixing - 5

Atmospheric parameters (T(sub eff), log g), masses and helium abundances are derived for 42 hot horizontal branch (HB) stars in the globular cluster NGC6752. For 19 stars we derive magnesium and iron abundances as well and find that iron is enriched by a factor of 50 on average with respect to the cluster abundance whereas the magnesium abundances are consistent with the cluster abundance. Radiation pressure may levitate heavy elements like iron to the surface of the star in a diffusive process. Taking into account the enrichment of heavy elements in our spectroscopic analyses we find that high iron abundances can explain part, but not all, of the problem of anomalously low gravities along the blue HB. The blue HB stars cooler than about 15,100 K and the sdB stars (T(sub eff) greater than or = 20,000 K) agree well with canonical theory when analysed with metal-rich ([M/H] = +0.5) model atmospheres, but the stars in between these two groups remain offset towards lower gravities and masses. Deep Mixing in the red giant progenitor phase is discussed as another mechanism that may influence the position of the blue HB stars in the (T(sub eff), log g)-plane but not their masses.

Moehler, S.↗

Helium abundances on the moon: Assumptions and estimates

Nuclear energy is a highly desirable source of energy, and He-3 is the most prized of the fusion reactants. As the Wisconsin Group has emphasized, He-3 may be the only true economic ore on the Moon. The lack of a shielding atmosphere on the Moon permits solar-wind alpha particles to impinge upon the lunar regolith and become implanted into the various solid components. In particular, large quantities of helium (5 to 50 ppm) are presented. The measured parameter of I(sub s)/FeO, a direct indicator of maturity and exposure age, can be used as a first approximation to predict the abundances of many solar-wind components in the soils. However, because ilmenite has a much higher retentivity for helium than the other phases, the TiO2 contents of the soils are better indicators of helium contents (Taylor, Space 90). High-Ti mare bassalt regions, such as at the Apollo 17 locale, appear to be the best areas for He mining (15 to 50 ppm He(sub T)), versus 3 to 9 ppm in the Highlands. However, the relationships between I(sub s)/FeO, TiO2 and He-3 contents are complicated - e.g., many of the most He-rich soils are immature to submature. The amount of He-3 in the regolith of the moon is estimated at 220,000 tons in the outer 2 m of the Maria.

Taylor, Lawrence A.↗

Heating of food in modified atmospheres

Food heating tests were conducted with two model foods; a Carnation turkey salad sandwich spread and frankfurter chunks in a sauce of water and agar. For the first series of tests comparing heating in five different atmospheres, the atmospheres were: (1) air at atmospheric pressure, (2) air at 5 psia, (3) helium at 5 psia, (4) oxygen-nitrogen mixture at 5 psia, and (5) oxygen-helium mixture at 5 psia. No significant differences in heating rates were caused by varying the atmosphere. Initial food temperatures were varied in the next series of tests. Heating times were found to increase with decreasing initial temperatures. There were also differences in heating times between the two foods used.

Sweat, V. E.↗

Solar wind ion composition and charge states

The solar wind, a highly tenuous plasma streaming from the Sun into interplanetary space at supersonic speed, is roughly composed of 95% hydrogen and 5% helium by number. All other, heavy elements contribute less than 0.1% by number and thus are truly test particles Nevertheless, these particles provide valuable information not present in the main components. We first discuss the importance of the heavy ions as tracers for processes in the solar atmosphere. Specifically, their relative abundances are found to be different in the solar wind as compared to the photosphere. This fractionation, which is best organized as a function of the first ionization time (FIT) of the elements under solar surface conditions, provides information on the structure of the chromosphere. where it is imparted on the partially ionized material by an atom-ion separation mechanism. Moreover, the charge states of the heavy ions can be used to infer the coronal temperature, since they are frozen-in near the altitude where the expansion time scale overcomes the ionization/recombination time scales. Next, we review the published values of ion abundances in the solar wind, concentrating on the recent results of the SWICS instrument on Ulysses. About 8 elements and more than 20 charge states can be routinely analyzed by this sensor. There is clear evidence that both the composition and the charge state distribution is significantly different in the fast solar wind from the south polar coronal hole, traversed by Ulysses in 1993/94, as compared to the solar wind normally encountered near the ecliptic plane. The fractionation between low- and high-FIT elements is reduced, and the charge states indicate a lower, more uniform coronal temperature in the hole. Finally, we discuss these results in the framework of existing theoretical models of the chromosphere and corona, attempting to identify differences between the low- and high-latitude regions of the solar atmosphere.

vonSteiger, R.↗

The Solar Wind

The first evidence of the solar wind was provided through observations of comet tail deflections by L. Biermann in 1951. A cometary ion tail is oriented along the difference between the cometary and solar wind velocities, whereas the dust tail is in the antisunward direction; the ion tail directions demonstrated the existence of an outflow of ionized gas from the Sun (the solar wind) and allowed estimates of solar wind speed. Spacecraft observations have now established that at 1 AU the solar wind has a typical ion number density of about 7 /cc and is composed by number of about 95% protons and 5% Helium, with other minor ions also present. The solar wind as observed at 1 AU in the ecliptic has speeds typically in the range 300-700 km/ s. At such speeds ions travel from the Sun to 1 AU in from 2.5 to 6 days. The impact of the solar wind on planets with magnetic fields (Earth, Jupiter, Saturn, Uranus, Neptune) causes phenomena such as magnetospheres, aurorae, and geomagnetic storms, whereas at objects lacking magnetospheres (Mars, Venus, comets), atmospheric neutrals undergo charge exchange and are picked up by the solar wind flow. The solar wind also shields the Earth from low energy cosmic rays, and is responsible for the existence of the anomalous component of the cosmic rays a low energy component that is created locally rather than in the galaxy. Presented here is a brief introduction to the solar wind and a description of some current topics of research. Solar wind properties vary a great deal due to the changing magnetic structure on the Sun.

Goldstein, B. E.↗

On-Orbit Operation of the Adiabatic Demagnetization Refrigerator on the Astro-H/Hitomi Soft X-ray Spectrometer Instrument

The Soft X-ray Spectrometer instrument on the Astro-H observatory contains a 6x6 array of x-ray microcalorimeters, which is cooled to 50 mK by an adiabatic demagnetization refrigerator (ADR). The ADR consists of three stages in order to provide stable detector cooling using either a 1.2 K superfluid helium bath or a 4.5 K Joule-Thomson (JT) cryocooler as its heat sink. When liquid helium is present, two of the ADRs stages are used to single-shot cool the detectors while rejecting heat to the helium. After the helium is depleted, all three stages are used to cool both the helium tank (to about 1.5 K) and the detectors (to 50 mK) using the JT cryocooler as its heat sink. The Astro-H observatory, renamed Hitomi after its successful launch in February 2016, carried approximately 36 liters of helium into orbit. On day 5, the helium had cooled sufficiently (1.4 K) to allow operation of the ADR. This paper describes the design, operation and on-orbit performance of the ADR.

sub-kelvin refrigeration↗

Design and On-Orbit Operation of the Adiabatic Demagnetization Refrigerator on the Hitomi Soft X-Ray Spectrometer Instrument

The Soft X-ray Spectrometer instrument on the Astro-H observatory contains a 6x6 array of x-ray microcalorimeters that is cooled to 50 mK by an adiabatic demagnetization refrigerator (ADR). The ADR consists of three stages in order to provide stable detector cooling using either a 1.2 K superfluid helium bath or a 4.5 K Joule-Thomson (JT) cryocooler as its heat sink. When liquid helium is present, two of the ADR's stages are used to single-shot cool the detectors while rejecting heat to the helium. After the helium is depleted, all three stages are used to continuously cool the helium tank (to about 1.5 K) and single-shot cool the detectors (to 50 mK), using the JT cryocooler as its heat sink. The Astro-H observatory, renamed Hitomi after its successful launch in February 2016, carried approximately 36 liters of helium into orbit. On day 5, the helium had cooled sufficiently (<1.4 K) to allow operation of the ADR. This paper describes the design, operation and on-orbit performance of the ADR, and the use of the ADR's heat rejection as a tool for mass gauging the helium tank.

adiabatic demagnetization refrigerator↗

Superfluid turbulence

At low temperatures (below 5 Kelvin), helium is a liquid with a very low kinematic viscosity. It was proposed that wind tunnels could be built using liquid helium as the test fluid. The primary advantages of such wind tunnels would be a combination of large Reynolds numbers and a relatively small apparatus. It is hoped that this combination will allow the study of high Reynolds number flows in an academic setting. There are two basic types of liquid helium wind tunnels that can be built, corresponding to the two phases of liquid helium. The high temperature phase (between approximately 2 to 5 Kelvin) is called helium 1 and is a Navier-Stokes fluid. There are no unanswered scientific questions about the design or operation of a wind tunnel in the helium 1 phase. The low temperature phase (below approximately 2 Kelvin) of liquid helium is called helium 2. This is a quantum fluid, meaning that there are some properties of helium 2 which are directly due to quantum mechanical effects and which are not observed in Navier-Stokes fluids. The quantum effects that are relevant to this paper are: (1) helium 2 is well described as a superposition of two separate fluids called the superfluid and the normal fluid. The normal-fluid component is a Navier-Stokes fluid and the superfluid is an irrotational Euler fluid; and (2) circulation in the superfluid exists only in quantized vortex filaments. All quantized vortex filaments have identical circulations kappa and core size a. The objective of the research at CTR was to develop an understanding of the microscopic processes responsible for the observed Navier-Stokes behavior of helium 2 flows.

Samuels, David C.↗

Final Summary of On-Orbit ADR Operation on Hitomis Soft X-Ray Spectrometer Instrument

The Soft X-ray Spectrometer (SXS) on the Astro-H observatory contains a 6x6 array of x-ray microcalorimeters that are cooled to 50 mK by an adiabatic demagnetization refrigerator (ADR). The ADR consists of three stages in order to provide stable detector cooling using either a 1.2 K superfluid helium bath or a 4.5 K Joule-Thomson (JT) cryocooler as its heat sink. Astro-H was renamed Hitomi after it was successfully launched in February 2016. The SXS carried approximately 36 liters of helium into orbit, and by day 5 the helium had cooled sufficiently (1.4 K) to allow operation of the ADR. This paper summarizes the ADRs performance during the 38 days that the satellite was operational.

space astronomy↗

5-year lifetime hybrid superfluid helium dewar for the AXAF X-Ray Spectrometer (XRS)

The focal plane of the AXAF X-Ray Spectrometer requires an operating temperature of 0.1 K with a mission lifetime of 5 yrs. This demanding task is accomplished with a hybrid cryogenic subsystem consisting of mechanical coolers, a superfluid helium dewar and an adiabatic demagnetization refrigerator. By using mechanical coolers to remove heat from the dewar outer vapor-cooled shield, a 5-yr lifetime is achievable with only a 483-liter tank. This approach takes advantage of flight-proven, high-performance dewar technology and recent success in the development of split, Stirling-cycle mechanical coolers. Although the dewar design principles are similar to those used previously, parasitic heat flow is reduced to a new level by an optimized tension strap support system and careful attention to insulation system details. The benefit of the mechanical coolers is maximized by dewar interface design features that minimize parasitic heating and thermal impedance of the coupling. The dewar design and thermal performance analysis are discussed. Helium lifetime sensitivities and the effects of mechanical cooler failures are predicted.

Nieczkoski, Stephen J.↗

Helium-Cooled Black Shroud for Subscale Cryogenic Testing

This shroud provides a deep-space simulating environment for testing scaled-down models of passively cooling systems for spaceflight optics and instruments. It is used inside a liquid-nitrogen- cooled vacuum chamber, and it is cooled by liquid helium to 5 K. It has an inside geometry of approximately 1.6 m diameter by 0.45 m tall. The inside surfaces of its top and sidewalls have a thermal absorptivity greater than 0.96. The bottom wall has a large central opening that is easily customized to allow a specific test item to extend through it. This enables testing of scale models of realistic passive cooling configurations that feature a very large temperature drop between the deepspace-facing cooled side and the Sun/Earth-facing warm side. This shroud has an innovative thermal closeout of the bottom wall, so that a test sample can have a hot (room temperature) side outside of the shroud, and a cold side inside the shroud. The combination of this closeout and the very black walls keeps radiated heat from the sample s warm end from entering the shroud, reflecting off the walls and heating the sample s cold end. The shroud includes 12 vertical rectangular sheet-copper side panels that are oriented in a circular pattern. Using tabs bent off from their edges, these side panels are bolted to each other and to a steel support ring on which they rest. The removable shroud top is a large copper sheet that rests on, and is bolted to, the support ring when the shroud is closed. The support ring stands on four fiberglass tube legs, which isolate it thermally from the vacuum chamber bottom. The insides of the cooper top and side panels are completely covered with 25- mm-thick aluminum honeycomb panels. This honeycomb is painted black before it is epoxied to the copper surfaces. A spiral-shaped copper tube, clamped at many different locations to the outside of the top copper plate, serves as part of the liquid helium cooling loop. Another copper tube, plumbed in a series to the top plate s tube, is clamped to the sidewall tabs where they are bolted to the support ring. Flowing liquid helium through these tubes cools the entire shroud to 5 K. The entire shroud is wrapped loosely in a layer of double-aluminized Kapton. The support ring s inner diameter is the largest possible hole through which the test item can extend into the shroud. Twelve custom-sized trapezoidal copper sheets extend inward from the support ring to within a few millimeters of the test item. Attached to the inner edge of each of these sheets is a custom-shaped strip of Kapton, which is aluminum- coated on the warm-facing (outer) side, and has thin Dacron netting attached to its cold-facing side. This Kapton rests against the test item, but the Dacron keeps it from making significant thermal contact. The result is a non-contact, radiatively reflective thermal closeout with essentially no gap through which radiation can pass. In this way, the part of the test item outside the shroud can be heated to relatively high temperatures without any radiative heat leaking to the inside.

Tuttle, James↗

Acousto-optic spectrometer for radio astronomy

A prototype acousto-optic spectrometer which uses a discrete bulk acoustic wave Itek Bragg cell, 5 mW Helium Neon laser, and a 1024 element Reticon charge coupled photodiode array is described. The analog signals from the photodiode array are digitized, added, and stored in a very high speed custom built multiplexer board which allows synchronous detection of weak signals to be performed. The experiment is controlled and the data are displayed and stored with an LSI-2 microcomputer system with dual floppy discs. The performance of the prototype acousto-optic spectrometer obtained from initial tests is reported.

Chin, G.↗

Measuring the Liquid Helium Volume on XRISM and Predicting the Liquid Lifetime

The XRISM/Resolve instrument uses an adiabatic demagnetization refrigerator (ADR) to cool microcalorimeters to 50 mK. The cryogenic system to support the ADR consists of a liquid helium dewar and 5 cryocoolers that provide a semi-redundant system. Operation of the ADR requires either a liquid helium heat sink at 1.2 K or 4.5 K heat sink provided by a multi-stage cryocooler system. The 5 cryocoolers also provide thermal protection to the liquid helium dewar. To calculate the expected lifetime of the liquid helium system, the liquid helium volume was measured before launch and several techniques were employed to determine on-orbit boil off rate.

Michael Dipirro↗

Helium abundance of the sun.

Critical review of the four methods that have been used to estimate the ratio of helium to hydrogen in the sun - the solar neutrino flux, spectral intensity of helium lines in prominences and the chromosphere, elemental abundance of solar cosmic rays, and variations of solar wind He/H. At present the measured value for the neutrino flux cannot be explained by any of the theoretical models of the sun, and thus the neutrino measurements cannot yield an estimate of He/H. Helium line intensity measurements give the most accurate values for He/H now available - i.e., 5 to 8% helium by number. However, these results refer to the chromosphere and prominences only, and questions of spatial and temporal variations of the observed quantities and of the inferred helium abundances have not yet been dealt with adequately.

Hirshberg, J.↗

Decomposing Solid Micropropulsion Nozzle Performance Issues

Micropropulsion technology is essential to the success of miniaturized spacecraft and can provide ultra-precise propulsion for small spacecraft. NASA Glenn Research Center has envisioned a micropropulsion concept that utilizes decomposing solid propellants for a valveless, leak-free propulsion system. Among the technical challenges of this decomposing solid micropropulsion concept is optimization of miniature, rectangular nozzles. A number of flat micronozzles were tested with ambient-temperature nitrogen and helium gas in a vacuum facility. The thrusters were etched out of silicon and had throat widths on the order of 350 microns and throat depths on the order of 250 microns. While these were half-sections of thrusters (two would be bonded together before firing), testing provided the performance trend for nozzles of this scale and geometry. Area ratios from 1 to 25 were tested, with thrust measured using an inverted pendulum thrust stand for nitrogen flows and a torsional thrust stand for helium. In the nitrogen testing, peak nozzle performance was achieved around area ratio of 5. In the helium series, nozzle performance peaked for the smallest nozzle tested area ratio 1.5. For both gases, there was a secondary performance peak above area ratio 15. At low chamber pressures (< 1.6 atm), nitrogen provided higher nozzle performance than helium. The performance curve for helium was steeper, however, and it appeared that helium would provide better performance than nitrogen at higher chamber pressures.

Reed, Brian↗

Experimental investigation of contamination prevention techniques to cryogenic surfaces on board orbiting spacecraft

Within the simulation limitations of on-orbit conditions, it was demonstrated that a helium purge system could be an effective method for reducing the incoming flux of contaminant species. Although a generalized purge system was employed in conjunction with basic telescope components, the simulation provided data that could be used for further modeling and design of a specific helium injection system. Experimental telescope pressures required for 90% attenuation appeared to be slightly higher (factor of 2 to 5). Cooling the helium purge gas and telescope components from 300 to 140 K had no measurable effect on stopping efficiency of a given mass flow of helium from the diffuse injector.

Hetrick, M. A.↗

Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging

The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.

NASA Discipline Life Sciences Technologies↗