Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEATING RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurement of rapidly-changing heating rates

Easily-fabricated heating rate sensor accurately measures heating rates that are changing rapidly. Design is based on numerous heat transfer analyses. Calibration is required, but no maintenance is needed other than for the thermocouple system.

Schwartz, E. W.↗

Thermal electron heating rate: A derivation

The thermal electron heating rate is an important heat source term in the ionospheric electron energy balance equation, representing heating by photoelectrons or by precipitating higher energy electrons. A formula for the thermal electron heating rate is derived from the kinetic equation using the electron-electron collision operator as given by the unified theory of Kihara and Aono. This collision operator includes collective interactions to produce a finite collision operator with an exact Coulomb logarithm term. The derived heating rate O(e) is the sum of three terms, O(e) = O(p) + S + O(int), which are respectively: (1) primary electron production term giving the heating from newly created electrons that have not yet suffered collisions with the ambient electrons; (2) a heating term evaluated on the energy surface m(e)/2 = E(T) at the transition between Maxwellian and tail electrons at E(T); and (3) the integral term representing heating of Maxwellian electrons by energetic tail electrons at energies ET. Published ionospheric electron temperature studies used only the integral term O(int) with differing lower integration limits. Use of the incomplete heating rate could lead to erroneous conclusions regarding electron heat balance, since O(e) is greater than O(int) by as much as a factor of two.

Hoegy, W. R.↗

Thermal electron heating rate - A derivation

The thermal electron heating rate is an important heat source term in the ionospheric electron energy balance equation, representing heating by photoelectrons or by precipitating higher energy electrons. A formula for the thermal electron heating rate is derived from the kinetic equation using the electron-electron collision operator as given by the unified theory of Kihara and Aono. This collision operator includes collective interactions to produce a finite collision operator with an exact Coulomb logarithm term. The derived heating rate O(e) is the sum of three terms, O(e) = O(P) + S + O(int), which are respectively: (1) primary electron production term giving the heating from newly created electrons that have not yet suffered collisions with the ambient electrons; (2) a heating term evaluated on the energy surface m(e)/2 = E(T) at the transition between Maxwellian and tail electrons at E(T); and (3) the integral term representing heating of Maxwellian electrons by eneegetic tail electrons at energies ET. Published ionospheric electron temperature studies used only the integral term O(int) with differing lower integration limits. Use of the incomplete heating rate could lead to erroneous conclusions regarding electron heat balance, since O(e) is greater than O(int) by as much as a factor of two. Previously announced in STAR as N84-15941

Hoegy, W. R.↗

Program documentation: Surface heating rate of thin skin models (THNSKN)

Program THNSKN computes the mean heating rate at a maximum of 100 locations on the surface of thin skin transient heating rate models. Output is printed in tabular form and consists of time history tabulation of temperatures, average temperatures, heat loss without conduction correction, mean heating rate, least squares heating rate, and the percent standard error of the least squares heating rates. The input tape used is produced by the program EHTS03.

Mcbryde, J. D.↗

Calculations of Solar Shortwave Heating Rates due to Black Carbon and Ozone Absorption Using in Situ Measurements

Results for the solar heating rates in ambient air due to absorption by black-carbon (BC) containing particles and ozone are presented as calculated from airborne observations made in the tropical tropopause layer (TTL) in January-February 2006. The method uses airborne in situ observations of BC particles, ozone and actinic flux. Total BC mass is obtained along the flight track by summing the masses of individually detected BC particles in the range 90 to 600-nm volume-equivalent diameter, which includes most of the BC mass. Ozone mixing ratios and upwelling and partial downwelling solar actinic fluxes were measured concurrently with BC mass. Two estimates used for the BC wavelength-dependent absorption cross section yielded similar heating rates. For mean altitudes of 16.5, 17.5, and 18.5 km (0.5 km) in the tropics, average BC heating rates were near 0.0002 K/d. Observed BC coatings on individual particles approximately double derived BC heating rates. Ozone heating rates exceeded BC heating rates by approximately a factor of 100 on average and at least a factor of 4, suggesting that BC heating rates in this region are negligible in comparison.

Gao, R. S.↗

Comparisons of free-flight experimental and predicted heating rates for the Space Shuttle

Experimental windward-ray heating rates measured during entry of the first Space Shuttle Orbiter mission are compared with predicted rates based on engineering and detailed equilibrium-air analyses. The experimental heating rates were reduced from temperature-time histories which are available only for the trajectory period after blackout which corresponds to a freestream Mach number and altitude of approximately 11.0 and 53 km, respectively. The experimental heating rates are computed for two measured emissivity data sets. The differences in the experimental heating rates based on the two emissivity data sets are sufficiently large that different interpretations of the STS-1 aerothermal environment may be inferred.

Zoby, E. V.↗

Radiative Heating Rates Computed With Clouds Derived From Satellite‐Based Passive and Active Sensors and their Effects on Generation of Available Potential Energy

Radiative heating rates computed with cloud properties derived from passive and active sensors are investigated. Zonal monthly radiative heating rate anomalies computed using both active and passive sensors show that larger variability in longwave cooling exists near the tropical tropopause and near the top of the boundary layer between ~50°N to ~50°S. Aerosol variability contributes to increases in shortwave heating rate variability. When zonal monthly mean cloud effects on the radiative heating rate computed with both active and passive sensors and those computed with passive sensor only are compared, the latter shows cooling and heating peaks corresponding to cloud top and base height ranges used for separating cloud types. The difference of these two sets of cloud radiative effect on heating rates in the middle to upper troposphere is larger than the radiative heating rate uncertainty estimated based on the difference of two active sensor radiative heating rate profile data products. In addition, radiative heating rate contribution to generation of eddy available potential energy is also investigated. Although radiation contribution to generation of eddy available potential energy averaged over a year and the entire globe is small, radiation increases the eddy available potential energy in the northern hemisphere during summer. Two key elements that longwave radiation contribute to the generation of eddy potential energy are (1) longitudinal temperature gradient in the atmosphere associated with land and ocean surface temperatures contrasts and absorption of longwave radiation emitted by the surface and (2) cooling near the cloud top of stratocumulus clouds.

Kato, Seiji↗

Servo calorimeter measures material heating rate

Servo calorimeter accurately measures the heating rate of a material exposed to nuclear radiation independently of the specific heat thermal conductivity of the material. The electrical power used is a direct measure of the nuclear heating rate.

Gilmour, G.↗

A simplified method for calculating the atmospheric heating rate by absorption of solar radiation in the stratosphere and mesosphere

Calculations of the atmospheric heating rate by absorption of solar radiation by O3, H2O, and CO2 are reported. The method needs only seven parameters for each molecule and is particularly useful for heating calculations in three-dimensional global circulation models below 80 km. Applying the formula to the observed distributions of O3, H2O, and CO2 produces reasonable latitudinal and seasonal variations in the heating rate. The calculated heating rate, however, is sensitive to the global distributions of the absorbing gases, and uncertainties in the O3 distribution above approximately 50 km and the H2O distribution below approximately 20 km may seriously affect the global distributions of the heating rate in these regions.

Shimazaki, T.↗

Directly Measured Heating Rates of a Tropical Subvisible Cirrus Cloud

We present the first direct measurements of the infrared and solar heating rates of a tropical subvisible cirrus (SVC) cloud sampled off the east coast of Nicaragua on 25 July 2007 by the NASA ER-2 aircraft during the Tropical Composition, Cloud and Climate Coupling Experiment (TC4). On this day a persistent thin cirrus layer, with mostly clear skies underneath, was detected in real time by the cloud lidar on the ER-2, and the aircraft was directed to profile down through the SVC. Measurements of the net broadband infrared irradiance and spectrally integrated solar irradiance above, below, and through the SVC are used to determine the infrared and solar heating rates of the cloud. The lidar measurements show that the variable SVC layer was located between approximately 13 and 15 km. Its midvisible optical depth varied from 0.01 to 0.10 with a mean of 0.034 +/- 0.033. Its depolarization ratio was approximately 0.4, indicative of ice clouds. From the divergence of the measured net irradiances the infrared heating rate of the SVC was determined to be approximately 2.50 - 3.24 K/d and the solar heating rate was found to be negligible. These values are consistent with previous indirect observations of other SVC and with model-generated heating rates of SVC with similar optical depths. This study illustrates the utility and potential of the profiling sampling strategy employed here. A more fully instrumented high-altitude aircraft that also included in situ cloud and aerosol probes would provide a comprehensive data set for characterizing both the radiative and microphysical properties of these ubiquitous tropical clouds

Bucholtz, Anthongy↗

A time Fourier analysis of zonal averaged ozone heating rates

A time-Fourier analysis is presented for the yearly variation of the zonal averaged ozone heating rates in the middle atmosphere based on a model study. The ozone heating rates are determined by utilizing two-dimensional ozone distributions, the altitude and latitude, and by including the effect of the curved earth's atmosphere. In addition, assumptions are introduced to the yearly variations of the ozone distributions due to the lack of sufficient existing ozone data. Among other results, it is shown that the first harmonic component indicates that the heating rates are completely out of phase between the northern and southern hemispheres. The second Fourier component shows a symmetric pattern with respect to the equator, as well as five distinct local extreme values of the ozone heating rate. The third harmonic component shows a pattern close to that of the first component except in the regions above 70 deg between 45-95 km in both hemispheres.

Wang, P.-H.↗

Effects of surface pressures and streamline metrics on the calculation of laminar heating rates

The effect of streamline geometry and pressure distributions on surface heating rates is examined for slender, spherically blunted cones. The modifications to the approximate aeroheating code include a curve fit of pressures computed by an Euler solution over a range of Mach numbers and cone angles. The streamline geometry is then found using the surface pressures and inviscid surface properties. Previously, streamlines were determined using the inviscid properties at the edge of the boundary layer when accounting for the effects of entropy-layer swallowing. Streamline calculations are now based on inviscid surface conditions rather than boundary-layer edge properties. However, the heating rates are calculated using inviscid properties at the edge of the boundary layer. Resulting heating rates compare favorably with solutions from the viscous-shock-layer equations.

Riley, Christopher J.↗

Effects of heating rate on density, microstructure, and strength of Si3N4-6 wt.% Y2O3 and a beta-prime sialon

The effects of the heating rate during sintering/firing on the final density, microstructure, and strength of Si3N4-6 wt% Y2O3 and beta-prime sialon, sintered for four hours at 1750 C, are examined. In Si3N4-6 wt% Y2O3 increasing the heating rate from 7 C/min to 25 C/min to 90 C/min results in a corresponding decrease in the final density from 3.01 g/cu cm to 2.92 g/cu cm to 2.76 g/cu cm. In the beta-prime sialon composition all three heating rates produce an equivalent final density of 3.13 g/cu cm. All heating rates in both compositions produce nonhomogeneous microstructures. The room-temperature strength of Si3N4-6 wt% Y2O3 increases from 372 to 510 MPa with increased density, while the corresponding strengths for the betaprime sialon at equivalent densities are 345 to 445 MPa.

Campbell, S. S.↗

Heating rates in tropical anvils

The interaction of infrared and solar radiation with tropical cirrus anvils is addressed. Optical properties of the anvils are inferred from satellite observations and from high-altitude aircraft measurements. An infrared multiple-scattering model is used to compute heating rates in tropical anvils. Layer-average heating rates in 2 km thick anvils were found to be on the order of 20 to 30 K/day. The difference between heating rates at cloud bottom and cloud top ranges from 30 to 200 K/day, leading to convective instability in the anvil. The calculations are most sensitive to the assumed ice water content, but also are affected by the vertical distribution of ice water content and by the anvil thickness. Solar heating in anvils is shown to be less important than infrared heating but not negligible. The dynamical implications of the computed heating rates are also explored and it is concluded that the heating may have important consequences for upward mass transport in the tropics. The potential impact of tropical cirrus on the tropical energy balance and cloud forcing are discussed.

Ackerman, Thomas P.↗

Radiative heating rates during AAOE and AASE

Radiative transit computations of heating rates utilizing data from the 1987 Airborne Antarctic Ozone Experiment (AAOE) (Tuck et al., 1989) and the 1989 Airborne Arctic Stratospheric Experiment (AASE) (Turco et al., 1990) are described. Observed temperature and ozone profiles and a radiative transfer model are used to compute the heating rates for the Southern Hemisphere during AAOE and the Northern Hemisphere during AASE. The AASE average cooling rates computed inside the vortex are in good agreement with the diabatic cooling rates estimated from the ER-2 profile data for N2O for the AASE period (Schoeberl et al., 1989).

Rosenfield, Joan E.↗

Influence of heating rate on the condensational instability

Analysis and numerical simulation are used to determine the effect that various heating rates have on the linear and nonlinear evolution of a typical plasma within a solar magnetic flux tube subject to the condensational instability. It is found that linear stability depends strongly on the heating rate. The results of numerical simulations of the nonlinear evolution of the condensational instability in a solar magnetic flux tube are presented. Different heating rates lead to quite different nonlinear evolutions, as evidenced by the behavior of the global internal energy.

Dahlburg, R. B.↗

Space Shuttle Orbiter flight heating rate measurement sensitivity to thermal protection system uncertainties

A study was completed to determine the sensitivity of computed convective heating rates to uncertainties in the thermal protection system thermal model. Those parameters considered were: density, thermal conductivity, and specific heat of both the reusable surface insulation and its coating; coating thickness and emittance; and temperature measurement uncertainty. The assessment used a modified version of the computer program to calculate heating rates from temperature time histories. The original version of the program solves the direct one dimensional heating problem and this modified version of The program is set up to solve the inverse problem. The modified program was used in thermocouple data reduction for shuttle flight data. Both nominal thermal models and altered thermal models were used to determine the necessity for accurate knowledge of thermal protection system's material thermal properties. For many thermal properties, the sensitivity (inaccuracies created in the calculation of convective heating rate by an altered property) was very low.

Bradley, P. F.↗