Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of an Underground Thermal Battery for Enabling Ground Source Heat Pump Applications and Shaping Electric Demand of Buildings

An innovative underground thermal battery (UTB) can provide not only a stable heat sink or heat source for efficient heat pump operation, but also a thermal energy storage to overcome the mismatch between intermittent renewable power supply and fluctuating thermal demands of a building. This article introduces the recent developments of the UTB, including concept design, lab tests, and modeling. Initial results indicate that the UTB has a potential to enable both efficient air-conditioning and active demand side management without sacrificing the desired comfort condition and convenience in the building.

25 ENERGY STORAGE↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel shallow bore ground heat exchanger for ground source heat pump applications—Model development and validation

A novel ground heat exchanger design, the Underground Thermal Battery (UTB), was proposed as a low-cost alternative to the conventional vertical bore ground heat exchanger (VBGHE) for the application of ground source heat pumps (GSHPs). The UTB is designed to be installed in a shallow borehole (less than 6 m deep) and thus could cost much less than the conventional VBGHE, which usually is installed in vertical bores 60 m deep. By utilizing natural convection of water and phase change materials, the UTB tempers its temperature change in response to thermal loads, which helps improve the efficiency of GSHPs. A one-dimensional (1D) model of the UTB has been developed and validated with the measured performance data of a small-scale UTB, as well as the simulation results of a more detailed three dimensional (3D) numerical model, which accounts for both heat transfer and fluid dynamics in the UTB. Further, this 1D model is computationally much more efficient than the 3D model and thus can simulate the annual performance of the UTB with acceptable computation time. The 1D model has been used to evaluate the performance of the UTB so that it can be compared with the conventional VBGHE.

42 ENGINEERING↗

Ion plating with an induction heating source

Induction heating is introduced as an evaporation heat source in ion plating. A bare induction coil without shielding can be directly used in the glow discharge region with no arcing. The only requirement is to utilize an rf inductive generator with low operating frequency of 75 kHz. Mechanical simplicity of the ion plating apparatus and ease of operation is a great asset for industrial applications; practically any metal such as nickel, iron, and the high temperature refractories can be evaporated and ion plated.

Spalvins, T.↗

Low cost uniform heat source

Electrically powered heat source was developed for ground simulation of isotope heat-source assembly in Brayton power system. Heat source, which operates on ordinary 110 vac power, consists of tungsten filament heating element wound onto a spirally grooved boron nitride core and inserted in a hollowed-out graphite hexahedron.

Smith, R. B.↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Empirical Study of the Effect of Thermal Loading on the Heating Efficiency of Variable-Speed Air Source Heat Pumps

Heating buildings with air source heat pumps (ASHPs) has the potential to save energy compared to utilizing conventional heat sources. Accurate understanding of the efficiency of ASHPs is important to maximize the energy savings. While it is well understood that, in general, ASHP efficiency decreases with decreasing outdoor temperature, it is not well understood how the ASHP efficiency changes with different levels of thermal loading, even though it is an important consideration for sizing and controlling ASHPs. The goal of this study was to create an empirical model of the ASHP efficiency as a function of two independent variables–outside temperature and level of thermal loading. Four ductless mini-split ASHPs were evaluated in a cold chamber where the temperature (representing the outdoor temperature) was varied over a wide range. For each temperature, the ASHP performance data were collected at several levels of thermal loading. The data for all four ASHPs were combined and approximated with an analytical function that can be used as a general model for the ASHP steady-state efficiency as a function of the outside temperature and level of thermal loading. To the knowledge of the authors, no such empirical model that is solely based on third-party test data has been published before. While limitations exist, the model can be used to help guide future selection and operation of ASHPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Source Heat Pumps in Very Cold Climates

Air source heat pumps (ASHPs) in heating mode use a refrigeration cycle to remove heat from the outside air and transfer it into a building. Therefore, ASHPs have the potential to save energy compared to conventional heat sources that create the heat as opposed to transferring it from outside. Many cold climate ASHPs available on the market today can operate at outside temperatures of -25 degrees C (-13 degrees F) or even lower. As a result of technological advances and other factors, there is growing interest in ASHPs in cold climates, including very cold regions such as Alaska. However, guidance on the selection, installation, and operation of ASHPs in these very cold climates is limited, as significant data gaps exist regarding the performance of ASHPs in very cold environments. To address these data gaps and guide future innovations, our research team has studied the field performance of several ASHP installations in Alaska and done lab evaluations of several ASHP models using a cold chamber. While a cold chamber cannot fully reflect field conditions, it allowed for changing one variable at a time and gaining additional understanding of the behavior of ASHPs that would be difficult to gain from field studies only. This study focused on two main variables: the temperature in the chamber (representing the outdoor temperature) and the level of thermal loading of the ASHP. The results from the field as well as the lab show that ASHPs can operate with relatively high efficiency even in very cold climates if used in appropriate situations and in an appropriate way. It was found that not only the outside temperature, but also the level of thermal loading is a significant factor affecting the ASHP efficiency and needs to be carefully considered when sizing and operating ASHPs in very cold climates.

air source heat pump↗

Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

Loop heat pipes (LHPs) have been used for thermal control of several NASA and commercial orbiting spacecraft. The LHP operating temperature is governed by the saturation temperature of its compensation chamber (CC). Most LHPs use the CC temperature for feedback control of its operating temperature. There exists a thermal resistance between the heat source to be cooled by the LHP and the LHP's CC. Even if the CC set point temperature is controlled precisely, the heat source temperature will still vary with its heat output. For most applications, controlling the heat source temperature is of most interest. A logical question to ask is: "Can the heat source temperature be used for feedback control of the LHP operation?" A test program has been implemented to answer the above question. Objective is to investigate the LHP performance using the CC temperature and the heat source temperature for feedback control

Ku, Jentung↗