Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEART RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of heart rate obtained from shorter duration Holter recordings to 24-hour mean heart rate in dogs with atrial fibrillation

The objective of this study was to evaluate the accuracy of short duration electrocardiographic (ECG) recordings extracted from ambulatory continuous ECG (Holter) to assess 24-hour mean heart rate in dogs with atrial fibrillation. In this retrospective study, Holter recordings obtained from 20 dogs with atrial fibrillation were selected for analysis. Ten out of 20 dogs were receiving drugs to control heart rate at the time of Holter evaluation. From the Holter recordings, heart rate averages were calculated for various sample durations (fiveminutes, 30 minutes, one-hour, two-hours, and three-hours) for each dog. Percentage of these shorter duration ECG obtained HR averages that fell within ±10%, ±15% and ± 20% of 24-hour mean heart rate was determined for each sample duration and for each dog. Seventy five percent of heart rate averages obtained from three-hour ECG recordings fell within ±10% of 24-hour mean HR. All the heart rate averages obtained from two-hour ECG recordings fell within ±20% of 24-hour mean heart rate. Based on the results of this study it can be concluded that the duration of the ECG recording affects the prediction accuracy for 24-hour Holter mean HR. Only two and three hours of Holter recordings provided all heart rate averages within ±20% of 24-hour mean heart rate. No significant differences were noted in the prediction accuracy of shorter duration ECG recordings based on rate control therapy status. Further prospective studies are needed to assess the accuracy of HR obtained at home using various ECG recording devices to predict 24-hour mean heart rate in dogs with atrial fibrillation.

59 BASIC BIOLOGICAL SCIENCES↗

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Abstract Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

60 APPLIED LIFE SCIENCES↗

Day-to-day reliability of basal heart rate and short-term and ultra short-term heart rate variability assessment by the Equivital eq02+ LifeMonitor in US Army soldiers

Introduction The present study determined the (1) day-to-day reliability of basal heart rate (HR) and HR variability (HRV) measured by the Equivital eq02+ LifeMonitor and (2) agreement of ultra short-term HRV compared with short-term HRV. Methods Twenty-three active-duty US Army Soldiers (5 females, 18 males) completed two experimental visits separated by >48 hours with restrictions consistent with basal monitoring (eg, exercise, dietary), with measurements after supine rest at minutes 20–21 (ultra short-term) and minutes 20–25 (short-term). HRV was assessed as the SD of R–R intervals (SDNN) and the square root of the mean squared differences between consecutive R–R intervals (RMSSD). Results The day-to-day reliability (intraclass correlation coefficient (ICC)) using linear-mixed model approach was good for HR (0.849, 95% CI: 0.689 to 0.933) and RMSSD (ICC: 0.823, 95% CI: 0.623 to 0.920). SDNN had moderate day-to-day reliability with greater variation (ICC: 0.689, 95% CI: 0.428 to 0.858). The reliability of RMSSD was slightly improved when considering the effect of respiration (ICC: 0.821, 95% CI: 0.672 to 0.944). There was no bias for HR measured for 1 min versus 5 min (p=0.511). For 1 min measurements versus 5 min, there was a very modest mean bias of −4 ms for SDNN and −1 ms for RMSSD (p≤0.023). Conclusion When preceded by a 20 min stabilisation period using restrictions consistent with basal monitoring and measuring respiration, military personnel can rely on the eq02+ for basal HR and RMSSD monitoring but should be more cautious using SDNN. These data also support using ultra short-term measurements when following these procedures.

General & Internal Medicine↗

iOS Heart Rate Monitor

The objective of this research project is to create a heart rate monitor mobile application (app) that allows the user to receive an accurate heart rate reading by placing their finger on the camera for about fifteen seconds. The app will be designed to read the heart rate through blood flow, and because blood flow is directly proportional with blood pressure, this app will also allow the user to get a blood pressure estimate. This enables anyone to have an understanding of their health issues if any are present. The overall goal to integrate this heart rate and blood pressure monitoring app with a personal dosimeter to build a comprehensive health monitoring app. The personal dosimeter Bluetooth connection function is being developed by another student group at Texas A and M University-Kingsville. This allows a user to transfer radiation readings from the Geiger counter to an iOS device while being able to monitor their health as they are exposed to radiation. This app's Bluetooth Geiger counter and heart rate/blood pressure monitor features would prove beneficial to individuals in the nuclear industry who are exposed to various levels of radiation. The combination of those functions will allow workers to measure their heart rate and blood pressure conveniently and within short periods of time. The people this app can help include nuclear power plant workers, radiology technicians, hazardous materials removal workers, and nuclear medicine technologists. We strive to create a mobile app that will allow a nuclear field worker to have a faster and more efficient health monitoring method. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the effect of incrementally increasing dry bulb temperature on linear and nonlinear measures of heart rate variability in nonpregnant, mid-gestation, and late-gestation sows

Abstract Characterizing the sow physiological response to an increased heat load is essential for effective heat stress mitigation. The study objective was to characterize the effects of a 400-min heating episode on sow heart rate variability (HRV) at different reproductive stages. HRV is a commonly used noninvasive proxy measure of autonomic function. Twenty-seven sows were enrolled in the study according to their gestation stage at time of selection: 1) nonpregnant (NP; n = 7), 2) mid-gestation (MID; 57.3 ± 11.8 d gestation; n = 11), and 3) late-gestation (LATE; 98.8 ± 4.9 d gestation; n = 8). The HRV data utilized in the study were collected from each pig as the dry bulb temperature in the room increased incrementally from 19.84 ± 2.15 °C to 35.54 ± 0.43 °C (range: 17.1–37.5 °C) over a 400-min period. After data collection, one 5-min set of continuous heart rate data were identified per pig for each of nine temperature intervals (19–20.99, 21–22.99, 23–24.99, 25–26.99, 27–28.99, 29–30.99, 31–32.99, 33–34.99, and 35–36.99 °C). Mean inter-beat interval length (RR), standard deviation of r-r intervals (SDNN), root mean square of successive differences (RMSSD), high frequency spectral power (HF), sample entropy (SampEn), short-term detrended fluctuation analysis (DFAα1), and three measures (%REC, DET, LMEAN) derived from recurrence quantification analysis were calculated for each data set. All data were analyzed using the PROC GLIMMIX procedure in SAS 9.4. Overall, LATE sows exhibited lower RR than NP sows (P < 0.01). The standard deviation of r–r intervals and RMSSD differed between each group (P < 0.01), with LATE sows exhibiting the lowest SDNN and RMSSD and NP sows exhibiting the greatest SDNN and RMSSD. Late-gestation sows exhibited lower HF than both MID and NP sows (P < 0.0001), greater DFA values than NP sows (P = 0.05), and greater DET compared to MID sows (P = 0.001). Late-gestation also sows exhibited greater %REC and LMEAN compared to MID (P < 0.01) and NP sows (all P < 0.01). In conclusion, LATE sows exhibited indicators of greater autonomic stress throughout the heating period compared to MID and NP sows. However, temperature by treatment interactions were not detected as dry bulb increased. Future studies are needed to fully elucidate the effect of gestational stage and increasing dry bulb temperature on sow HRV.

Agriculture↗

The prognostic value of heart rate response during vasodilator stress myocardial perfusion imaging in patients with end-stage renal disease undergoing renal transplantation

Background: In asymptomatic end-stage renal disease (ESRD) patients undergoing vasodilator stress myocardial perfusion imaging (MPI) prior to renal transplantation (RT), the impact of pre-transplant heart rate response (HRR) to vasodilator stress on post-RT outcomes is unknown. Methods: We analyzed a retrospective cohort of asymptomatic patients with ESRD who underwent a vasodilator stress SPECT-MPI and subsequently received RT. Blunted HRR was defined as HRR <28% for regadenoson stress and <20% for adenosine stress. The primary endpoint was major adverse cardiac events (MACE), defined as cardiac death or myocardial infarction. Clinical risk was assessed using the sum of risk factors set forth by the AHA/ACCF consensus statement on the assessment of RT candidates. Results: Among 352 subjects, 140 had an abnormal pre-transplant HRR. During a mean follow-up of 3.2 ± 2.0 years, 85 (24%) MACEs were observed. Blunted HRR was associated with increased MACE risk (hazard ratio 1.72; 95% confidence interval 1.12-2.63, P = 0.013), and remained significant after adjustment for gender, sum of AHA/ACCF risk factors, summed stress score, baseline heart rate, and β-blocker use. HRR was predictive of MACE in patients with normal MPI and irrespective of clinical risk. Blunted HRR was associated with a significant increase in post-operative (30-day) MACE risk (17.9% vs 8.5%; P = 0.009). Conclusion: In asymptomatic ESRD patients being evaluated for RT, a blunted pre-transplant HRR was predictive of post-RT MACE. HRR may be a valuable tool in the risk assessment of RT candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TRPA1 mediates changes in heart rate variability and cardiac mechanical function in mice exposed to acrolein

Short-term exposure to ambient air pollution is linked with adverse cardiovascular effects. While previous research focused primarily on particulate matter-induced responses, gaseous air pollutants also contribute to cause short-term cardiovascular effects. Mechanisms underlying such effects have not been adequately described, however the immediate nature of the response suggests involvement of irritant neural activation and downstream autonomic dysfunction. Thus, this study examines the role of TRPA1, an irritant sensory receptor found in the airways, in the cardiac response of mice to acrolein and ozone. Conscious unrestrained wild-type C57BL/6 (WT) and TRPA1 knockout (KO) mice implanted with radiotelemeters were exposed once to 3 ppm acrolein, 0.3 ppm ozone, or filtered air. Heart rate (HR) and electrocardiogram (ECG) were recorded continuously before, during and after exposure. Analysis of ECG morphology, incidence of arrhythmia and heart rate variability (HRV) were performed. Cardiac mechanical function was assessed using a Langendorff perfusion preparation 24 h post-exposure. Acrolein exposure increased HRV independent of HR, as well as incidence of arrhythmia. Acrolein also increased left ventricular developed pressure in WT mice at 24 h post-exposure. Ozone did not produce any changes in cardiac function. Neither gas produced ECG effects, changes in HRV, arrhythmogenesis, or mechanical function in KO mice. These data demonstrate that a single exposure to acrolein causes cardiac dysfunction through TRPA1 activation and autonomic imbalance characterized by a shift toward parasympathetic modulation. Furthermore, it is clear from the lack of ozone effects that although gaseous irritants are capable of eliciting immediate cardiac changes, gas concentration and properties play important roles. - Highlights: • Acute acrolein exposure causes autonomic imbalance and altered CV function in mice. • TRPA1 mediates acrolein-induced autonomic nervous system cardiac effects. • Sensory irritation contributes to acrolein-induced cardiac arrhythmia & dysfunction.

60 APPLIED LIFE SCIENCES↗

Predicting fatigue from heart rate signatures using functional logistic regression

Physical fatigue can have adverse effects on humans in extreme environments. Therefore, being able to predict fatigue using easy to measure metrics such as heart rate (HR) signatures has potential to have an impact in real-life scenarios. We apply a functional logistic regression model that uses HR signatures to predict physical fatigue, where physical fatigue is defined in a data-driven manner. Data were collected using commercially available wearable devices on 47 participants hiking the 20.7-mile Grand Canyon rim-to-rim trail in a single day. Fitted model provides good predictions and interpretable parameters for real-life application.

60 APPLIED LIFE SCIENCES↗

Wearable and sensitive heart-rate detectors based on PbS quantum dot and multiwalled carbon nanotube blend film

Wearable and sensitive photodetectors (PDs) have been demonstrated based on a blend film of PbS quantum dots (QDs) and QDs modified multiwalled carbon nanotubes (MWCNTs). Owing to the synergetic effect from high light sensitivity of PbS QDs and excellent conductive and mechanical properties of MWCNTs, the blend PDs show high sensitivity and flexibility performance: device responsivity and detectivity reach 583 mA/W and 3.25 × 10{sup 12 }Jones, respectively, and could stand large number (at least 10 000 cycles) and wide angle (up to 80°) bending. Furthermore, the wearable and sensitive PDs have been applied to measure the heart rate in both red and near infrared (NIR) ranges. The presented PDs are expected to work as sensor candidates in integrated electronic skin.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development and validation of a mathematical model of heart rate response to fluid perturbation

Physiological closed-loop controlled (PCLC) medical devices monitor and automatically adjust the patient’s condition by using physiological variables as feedback, ideally with minimal human intervention to achieve the target levels set by a clinician. PCLC devices present a challenge when it comes to evaluating their performance, where conducting large clinical trials can be expensive. Virtual physiological patients simulated by validated mathematical models can be utilized to obtain preclinical evidence of safety and assess the performance of the PCLC medical device during normal and worst-case conditions that are unlikely to happen in a limited clinical trial. A physiological variable that plays a major role during fluid resuscitation is heart rate (HR). For in silico assessment of PCLC medical devices regarding fluid perturbation, there is currently no mathematical model of HR validated in terms of its predictive capability performance. This paper develops and validates a mathematical model of HR response using data collected from sheep subjects undergoing hemorrhage and fluid infusion. The model proved to be accurate in estimating the HR response to fluid perturbation, where averaged between 21 calibration datasets, the fitting performance showed a normalized root mean square error (NRMSE) of 7.41 ± 2.8%. The model was also evaluated in terms of model predictive capability performance via a leave-one-out procedure (21 subjects) and an independent validation dataset (6 subjects). Two different virtual cohort generation tools were used in each validation analysis. The generated envelope of virtual subjects robustly met the defined acceptance criteria, in which 95% of the testing datasets presented simulated HR patterns that were within a deviation of 50% from the observed data. In addition, out of 16000 and 18522 simulated subjects for the leave one-out and independent datasets, the model was able to generate at least one virtual subject that was close to the real subject within an error margin of 9.56 ± 3.15% and 11.1 ± 1.22% NRMSE, respectively. In conclusion, the model can generate valid virtual HR physiological responses to fluid perturbation and be incorporated into future non-clinical simulated testing setups for assessing PCLC devices intended for fluid resuscitation.

59 BASIC BIOLOGICAL SCIENCES↗

Short-term effects of particulate matter in metro cabin on heart rate variability in young healthy adults: Impacts of particle size and source

Highlights: • Exposure to metro PM was associated with decreased HRV in young healthy adults. • The strength and lag time for effects of PM on HRV varied by particle size. • Greater decreases in HRV suggested that females were more susceptible to the effects of PM exposure. • Ambient PM from combustion source (indicated by black carbon) has adverse health effects on passengers in cabin. Metro system has become popular in urban areas. However, short-term effects of size-fractionated particulate matter (PM) on cardiac autonomic function in metro system remain unexplored.

54 ENVIRONMENTAL SCIENCES↗

Association between human and animal thermal comfort indices and physiological heat stress indicators in dairy calves

Warm summer episodes have a significant effect on the overall health and well-being of young cattle; however, it is not known which temperature measure should be used for estimating heat stress in dairy calves. In this study, generalized linear mixed-effects models were used to estimate the relationships between thermal comfort indices and animal-based heat stress indicators in sixteen Holstein bull calves that were housed in individual calf hutches. Data were collected under continental weather characteristics over a 5-day period: day 1 (lower-temperature day), days 2 and 3 (heat stress days), and a 2-day post-stress period. Relative humidity, ambient temperature, the heat index, the humidex and five different temperature–humidity indices (THI) were used as thermal indices. Physiological variables monitored included respiratory rate, rectal temperature, ear skin temperature and heart rate. The heat index and the humidex measuring human thermal comfort were more closely associated with physiological measures than were the ambient temperature or the THIs (in case of heat index: R{sup 2} = 0.87 for respiratory rate, R{sup 2} = 0.63 for rectal temperature, R{sup 2} = 0.70 for ear skin temperature, and R{sup 2} = 0.78 for heart rate, respectively; in case of humidex: R{sup 2} = 0.85 for respiratory rate, R{sup 2} = 0.60 for rectal temperature, R{sup 2} = 0.68 for ear skin temperature, and R{sup 2} = 0.75 for heart rate, respectively). Based on our results, parameters of human outdoor comfort seem better to estimate heat stress in dairy calves in a continental region than those of THIs or ambient temperature.

54 ENVIRONMENTAL SCIENCES↗

Multi-modal characterisation of early-stage, subclinical cardiac deterioration in patients with type 2 diabetes

Abstract Background Type 2 diabetes mellitus (T2DM) is a major risk factor for heart failure with preserved ejection fraction and cardiac arrhythmias. Precursors of these complications, such as diabetic cardiomyopathy, remain incompletely understood and underdiagnosed. Detection of early signs of cardiac deterioration in T2DM patients is critical for prevention. Our goal is to quantify T2DM-driven abnormalities in ECG and cardiac imaging biomarkers leading to cardiovascular disease. Methods We quantified ECG and cardiac magnetic resonance imaging biomarkers in two matched cohorts of 1781 UK Biobank participants, with and without T2DM, and no diagnosed cardiovascular disease at the time of assessment. We performed a pair-matched cross-sectional study to compare cardiac biomarkers in both cohorts, and examined the association between T2DM and these biomarkers. We built multivariate multiple linear regression models sequentially adjusted for socio-demographic, lifestyle, and clinical covariates. Results Participants with T2DM had a higher resting heart rate (66 vs. 61 beats per minute,p < 0.001), longer QTc interval (424 vs. 420ms,p < 0.001), reduced T wave amplitude (0.33 vs. 0.37mV,p < 0.001), lower stroke volume (72 vs. 78ml,p < 0.001) and thicker left ventricular wall (6.1 vs. 5.9mm,p < 0.001) despite a decreased Sokolow-Lyon index (19.1 vs. 20.2mm,p < 0.001). T2DM was independently associated with higher heart rate (beta = 3.11, 95% CI = [2.11,4.10],p < 0.001), lower stroke volume (beta = −4.11, 95% CI = [−6.03, −2.19],p < 0.001) and higher left ventricular wall thickness (beta = 0.133, 95% CI = [0.081,0.186],p < 0.001). Trends were consistent in subgroups of different sex, age and body mass index. Fewer significant differences were observed in participants of non-white ethnic background. QRS duration and Sokolow-Lyon index showed a positive association with the development of cardiovascular disease in cohorts with and without T2DM, respectively. A higher left ventricular mass and wall thickness were associated with cardiovascular outcomes in both groups. Conclusion T2DM prior to cardiovascular disease was linked with a higher heart rate, QTc prolongation, T wave amplitude reduction, as well as lower stroke volume and increased left ventricular wall thickness. Increased QRS duration and left ventricular wall thickness and mass were most strongly associated with future cardiovascular disease. Although subclinical, these changes may indicate the presence of autonomic dysfunction and diabetic cardiomyopathy. Graphical Abstract

Cardiovascular System & Cardiology↗

A fixed mass method for the Kramers-Moyal expansion—Application to time series with outliers

Extraction of stochastic and deterministic components from empirical data—necessary for the reconstruction of the dynamics of the system—is discussed. We determine both components using the Kramers-Moyal expansion. In our earlier papers, we obtained large fluctuations in the magnitude of both terms for rare or extreme valued events in the data. Calculations for such events are burdened by an unsatisfactory quality of the statistics. In general, the method is sensitive to the binning procedure applied for the construction of histograms. Instead of the commonly used constant width of bins, we use here a constant number of counts for each bin. This approach—the fixed mass method—allows to include in the calculation events, which do not yield satisfactory statistics in the fixed bin width method. The method developed is general. To demonstrate its properties, here, we present the modified Kramers-Moyal expansion method and discuss its properties by the application of the fixed mass method to four representative heart rate variability recordings with different numbers of ectopic beats. These beats may be rare events as well as outlying, i.e., very small or very large heart cycle lengths. The properties of ectopic beats are important not only for medical diagnostic purposes but the occurrence of ectopic beats is a general example of the kind of variability that occurs in a signal with outliers. To show that the method is general, we also present results for two examples of data from very different areas of science: daily temperatures at a large European city and recordings of traffics on a highway. Using the fixed mass method, to assess the dynamics leading to the outlying events we studied the occurrence of higher order terms of the Kramers-Moyal expansion in the recordings. We found that the higher order terms of the Kramers-Moyal expansion are negligible for heart rate variability. This finding opens the possibility of the application of the Langevin equation to the whole range of empirical signals containing rare or outlying events. Note, however, that the higher order terms are non-negligible for the other data studied here and for it the Langevin equation is not applicable as a model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗