Engineering PapersSearch

SEARCH · Engineering Papers

Results for “HEART FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Miniature implantable instrument measures and transmits heart function data

Heart diameter is derived from measured transit time of 2.25 MHz ultrasonic pulse between two piezoelectric crystals attached to diametrically opposite heart surfaces. Miniature instrument implanted in chest telemeters information to external receiver-converter. System permits continual dimensional data recording taken from awake animals during long-term experiments.

Lee, R. D.

High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia

High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function due to exposure to high altitude.

Zupet, Petra

[Heart functions in monkeys during a 2-week antiorthostatic hypokinesia]

Dynamics of the left heart ventricular muscle contractility and compliance was studied in 4 monkeys in the head down position (antiorthostatic hypokinesia) with the body angle 10 during 2 weeks. Functional tests on a tilt table and under two conditions of centrifuge rotation were performed prior to and after the antiorthostatic hypokinesia. No changes in the left heart ventricular muscle contractility was found. However, the sensitivity level of the baroreflex control decreased. Compliance of the left heart myocardial fibre increased in the first hours and days of the antiorthostatic hypokinesia.

NASA Discipline Regulatory Physiology

Effects of moderate heart failure and functional overload on rat plantaris muscle

It is thought that changes in sarco(endo)plasmic reticulum Ca(2+)-ATPase (SERCA) of skeletal muscle contribute to alterations in skeletal muscle function during congestive heart failure (CHF). It is well established that exercise training can improve muscle function. However, it is unclear whether similar adaptations will result from exercise training in a CHF patient. Therefore, the purpose of this study was to determine whether skeletal muscle during moderate CHF adapts to increased activity, utilizing the functional overload (FO) model. Significant increases in plantaris mass of the CHF-FO and sham-FO groups compared with the CHF and control (sham) groups were observed. Ca(2+) uptake rates were significantly elevated in the CHF group compared with all other groups. No differences were detected in Ca(2+) uptake rates between the CHF-FO, sham, and sham-FO groups. Increases in Ca(2+) uptake rates in moderate-CHF rats were not due to changes in SERCA isoform proportions; however, FO may have attenuated the CHF-induced increases through alterations in SERCA isoform expression. Therefore, changes in skeletal muscle Ca(2+) handling during moderate CHF may be due to alterations in regulatory mechanisms, which exercise may override, by possibly altering SERCA isoform expression.

Non-NASA Center

Heart Imaging System

Johnson Space Flight Center's device to test astronauts' heart function in microgravity has led to the MultiWire Gamma Camera, which images heart conditions six times faster than conventional devices. Dr. Jeffrey Lacy, who developed the technology as a NASA researcher, later formed Proportional Technologies, Inc. to develop a commercially viable process that would enable use of Tantalum-178 (Ta-178), a radio-pharmaceutical. His company supplies the generator for the radioactive Ta-178 to Xenos Medical Systems, which markets the camera. Ta-178 can only be optimally imaged with the camera. Because the body is subjected to it for only nine minutes, the radiation dose is significantly reduced and the technique can be used more frequently. Ta-178 also enables the camera to be used on pediatric patients who are rarely studied with conventional isotopes because of the high radiation dosage.

Source record

Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)

The recognition and understanding of cardiovascular adaptation to spaceflight has experienced substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented a 15 percent reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume following diuresis and other physiological processes to reduce blood volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been elucidated. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a GAS payload. The experimental apparatus consists of a pneumatically actuated, elliptical artificial ventricle connected to a closed-loop, hydraulic circuit with compliance and resistance elements to create physiologic pressure and flow conditions. The ventricle is instrumented with high-fidelity, acceleration-insensitive, catheter-tip pressure transducers (Millar Instruments) in the apex and base to determine the instantaneous ventricular pressures and (delta)P(sub LV) across the left ventricle (LVP(sub apex)-LVP(sub base). The ventricle is also instrumented with a flow probe and pressure transducers immediately upstream of the inflow valve and downstream of the outflow valve. The experiment will be microprocessor controlled with analog signals stored on the FM data tape recorder. By varying the circulating fluid volume, ventricular function can be determined for varying preload pressures with fixed afterload pressure. Pilot experiments on board the NASA KC-135 aircraft have demonstrated proof-of-concept and provided early support for the proposed hypothesis. A review of the pilot experiments and developmental progress on the GAS version of this experiment will be presented.

Pantalos, George M.

Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)

The investigation of cardiovascular adaptation to space flight has seen substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented an initial increase, followed by a progressive reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been identified. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a Get Away Special (GAS) payload within the next year.

Pantalos, George M.

Cardiovascular Responses to Simulated Spaceflight: Molecular Signatures and Surrogate Outputs to Measure CVD Risk

During extended space missions beyond low Earth orbit, astronauts will encounter prolonged periods of weightlessness and low dose space radiation. Previous studies have shown that exposure to small doses of high LET radiation (< 50 cGy) can lead to both short-term and long-term alterations in heart function, structure and underlying molecular mechanisms. In this study, we aim to identify the molecular signature associated with the cardiovascular response to simulated galactic cosmic radiation (5-ion GCR) alone or in combination with simulated weightlessness at time intervals relevant to mission length and recovery. Additionally, we aim to determine whether sex impacts cardiovascular responses to these spaceflight factors. Our overarching goal is to enhance our understanding of the cardiovascular risks associated with extended space missions and the clinical endpoints they suggest. We hypothesize that exposure to simulated space radiation leads to enduring alterations in the transcriptome, redox signaling and cytokine environment of cardiovascular tissue, some which have known links with reduced cardiovascular performance, aging, and increased risk of cardiovascular disease (CVD). Furthermore, we posit that simulated space radiation exposure in combination with simulated microgravity exacerbates cardiovascular deficits compared to single factor exposure. Female and male C57BL/6J mice, aged 23-24 weeks, were exposed to a single dose of 5, 15, or 50 cGy of 5-ion GCR, or sham-treated (0 cGy). Euthanasia was performed at 14 days and ~4 months post-irradiation. Hearts, aorta and blood plasma were collected shortly thereafter. RNA-sequencing of left ventricles at ~4 months post-GCR exposure revealed sex differences in the heart transcriptome with a few genes showing radiation-dependent changes in expression levels. Notably, some of the differentially expressed genes in 15 and 50 cGy GCR groups are known to play roles in the development of CVD. Analysis of protein levels of a subset of inflammatory cytokines in the heart indicated sex differences but no differences between sham and 50 cGy groups. Results also showed correlations among differentially expressed genes and a subset of inflammatory cytokines, with some correlations altered by GCR exposure. These findings suggest that GCR exposure can modify protein and gene networks linked to inflammation and CVD progression. In the aorta, telomere lengths were comparable across treatment groups sexes. Mitochondrial copy number is a biomarker for mitochondrial function with decreased copy numbers associated with cardiometabolic disease traits. Mitochondrial copy numbers of aorta also showed no sex nor dose differences. In a second study, mice underwent one week of simulated microgravity by hindlimb unloading (HU) and then exposed to a single dose of 15 cGy of 5-ion GCR. HU was conducted for an additional two weeks following GCR exposure. Single factor exposure groups (HU or GCR only) also were included in the study. Euthanasia was then performed and the same tissues were collected. Protein levels of select inflammatory cytokines in the heart showed sex-dependent differences in expression. In the aorta, telomere lengths and mitochondrial copy number also showed sex differences. In summary, our results indicate differences between sexes in biomarkers related to cardiovascular health. Exposure to 5-ion GCR or HU, alone or in combination, did not result in changes in most of the cardiovascular biomarkers that were examined. However, in the heart, simulated space radiation at doses of 15 and 50 cGy led to long-term alterations in the expression levels of a small group of genes known to be associated with the progression of CVD. The long-term transcriptomic changes resulting from exposure to simulated space radiation should be carefully investigated to mitigate adverse cardiovascular events during and after deep space missions. Our results also highlight the importance of sex-specific strategies in monitoring and maintaining cardiovascular health during and after deep space missions.

cardiovascular

Myocardial wall-thickness transducer

Device consists of highly compliant circular beam attached to piezoresistive strain gage and barbed needle. Radial deflection of myocardium is measured with minimal disturbance of normal heart functions.

Feldstein, C.

Altitude acclimatization. Citations from the International Aerospace Abstracts data base

This bibliography of citations to the international literature covers aspects of altitude acclimatization. Included are articles concerning high altitude environments, hypoxia, heart function and hemodynamic responses, physical exercise, human tolerances and reactions, physiological responses, and oxygen consumption. This updated bibliography contains 164 citations, 35 of which are new entries to the previous edition.

Mauk, S. C.

Transducers For Heat Research

Series of transducers with seven different configurations enable measurement of forces and displacements in heart wall. New transducers small, cause minimal perturbation of heart function and attached and detached without causing excessive tissue damage. All units implanted or removed during single heartbeat, permitting rapid relocation for detail mapping.

Feldstein, C.

Cardiac Monitor

Under contract to Johnson Space Center, the University of Minnesota developed the concept of impedance cardiography as an alternative to thermodilution to access astronaut heart function in flight. NASA then contracted Space Labs, Inc. to construct miniature space units based on this technology. Several companies then launched their own impedance cardiography, including Renaissance Technologies, which manufactures the IQ System. The IQ System is 5 to 17 times cheaper than thermodilution, and features the signal processing technology called TFD (Time Frequency Distribution). TFD provides three- dimensional distribution of the blood circulation force signals, allowing visualization of changes in power, frequency and time.

Source record