Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HE-3 COUNTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparative Neutron Detection Efficiency in He-3 Proportional Counters and Liquid Scintillators

We present new results on the neutron detection efficiency of detection systems based on He-3 proportional counters compared to organic liquid scintillators. The experiments were conducted using a well-characterized Cf-252 neutron source, measured bare, and shielded with slabs of polyethylene. The results show that the intrinsic neutron detection efficiency for the bare source is approximately 25% for the He-3 system, and 67% for the liquid scintillator system. When polyethylene sheets were used to shield the source in 2.54 cm increments, the neutron detection efficiency of both systems decreased exponentially to approximately 10% for the case of 25.4 cm. Experimental results were simulated using MCNPX-PoliMi and good agreement was found between measurement and simulation results for all the cases considered here.

Organic scintillator, He-3, neutron detection, det↗

Neutron spectrometry with He-3 proportional counters

Helium filled proportional counters are widely used in the field of neutron detection and spectrometry. In this work the response of a commercially available He-3 counter is studied experimentally and calculated with Monte Carlo for the neutron energy range from 230 keV up to about 7 MeV. The calculated response of the system is used to determine neutron yield energy distribution emitted from an extended {sup nat}U/Pb assembly irradiated with 1.6 GeV deuterons. The results are in acceptable agreement with the calculated neutron distribution with DCM-DEM code. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternatives for Helium-3 in Multiplicity Counters

Alternatives to helium-3 are being actively pursued due to the shortage and rising costs of helium-3. For safeguards applications, there are a number of ongoing investigations to find alternatives that provide the same capability in a cost-effective manner. One of the greatest challenges is to find a comparable alternative for multiplicity counters, since they require high efficiency and short collection or die-away times. Work has been progressing on investigating three commercially available alternatives for high efficiency multiplicity counters: boron trifluoride (BF3) filled proportional tubes, boron-lined proportional tubes, and lithium fluoride with zinc sulfide coated light guides. The baseline multiplicity counter used for the investigation is the Epithermal Neutron Multiplicity Counter with 121 helium-3 filled tubes at 10 atmosphere pressure, which is a significant capability to match. The primary tool for the investigation has been modeling and simulation using the Monte Carlo N-Particle eXtended (MCNPX) radiation transport program, with experiments to validate the models. To directly calculate the coincidence rates in boron-lined (and possibly other) detectors, the MCNPX code has been enhanced to allow the existing coincidence tally to be used with energy deposition rather than neutron capture reactions. This allows boron-lined detectors to be modeled more accurately. Variations of tube number and diameter along with variations in the amount of inter-tube moderator have been conducted for the BF3 and boron-lined cases. Tube pressure was investigated for BF3, up to two atmospheres, as well as optimal boron thickness in the boron-lined tubes. The lithium fluoride was modeled as sheets of material with light guides in between, and the number and thickness of the sheets investigated. The amount of light guide, which in this case doubles as a moderator, was also optimized. The results of these modeling and simulation optimization investigations are described and results presented.

Ely, James H.↗

Compensated gadolinium-loaded plastic scintillators for thermal neutron detection (and counting)

Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by gadolinium-155 and gadolinium-157, alternative treatment to Pulse Shape Discrimination has to be proposed in order to display a trustable count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a non-gadolinium loaded compensation scintillator solely interacts with the photon part of the incident radiation. Posterior to the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate after photon response compensation falls into statistical fluctuations or provides a robust image of a neutron activity. A laboratory prototype is tested under both photon and neutron irradiations, allowing us to investigate the performance of the overall compensation system in terms of neutron detection, especially with regards to a commercial helium-3 counter. The study reveals satisfactory results in terms of sensitivity and orientates future investigation toward promising axes. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary measurements of neutrons from the D-D reaction in the COMPASS tokamak

Recent results of measured fast neutrons created in the D-D reaction on the COMPASS tokamak during ohmic discharges are presented in this paper. Two different type detectors were used during experiment. He-3 detectors and bubble detectors as a support. The measurements are an introduction for neutron diagnostic on tokamak COMPASS and monitoring neutrons during discharges with Neutral Beam Injection (NBI). The He-3 counters and bubble detectors were located in two positions near tokamak vacuum chamber at a distance less than 40 cm to the centre of plasma. The neutrons flux was observed in ohmic discharges. However, analysis of our results does not indicate any clear source of neutrons production during ohmic discharges.

07 ISOTOPE AND RADIATION SOURCES↗

Safeguards Technology Development Program 1st Quarter FY 2018 Report

LLNL will evaluate the performance of a stilbene-based scintillation detector array for IAEA neutron multiplicity counting (NMC) applications. This effort will combine newly developed modeling methodologies and recently acquired high-efficiency stilbene detector units to quantitatively compare the prototype system performance with the conventional He-3 counters and liquid scintillator alternatives.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Safeguards Technology Development Program 3rd Quarter FY 2018 Report

LLNL will evaluate the performance of a stilbene-based scintillation detector array for IAEA neutron multiplicity counting (NMC) applications. This effort will combine newly developed modeling methodologies and recently acquired high-efficiency stilbene detector units to quantitatively compare the prototype system performance with the conventional He-3 counters and liquid scintillator alternatives.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Alternatives to Helium-3 for Neutron Multiplicity Counters

Multiplicity counters are an example of a neutron detection system affected by the shortage of 3He. Efforts are underway to identify potential 3He neutron detector replacements for use in multiplicity counters. Boron-10 and 6Li based systems are two of the options being explored as near-term 3He alternatives for neutron multiplicity counters. Simulations of BF3, 10B-lined proportional counters and 6Li/ZnS(Ag) sheets in various configurations have been performed with the Monte Carlo particle transport code MCNPX and compared to simulations of existing 3He counters. The system performances are being compared using figure of merits that are the square or cube of the total system efficiency divided by the die-away time. Design considerations include developing a system with enough neutron detection material to achieve the highest possible efficiency, while simultaneously minimizing system size. Adequate moderation is required to thermalize the incident neutrons for increased counting efficiency but as the system size increases so will the die-away time (average lifetime of neutrons in the counter). The optimal moderator configuration is one for which the increase in neutron detection efficiency is not defeated by an increase in die-away time. Thus, the entire system performance must be evaluated with every configuration change. The simulation results will be validated against a bench-top demonstrator unit design based on the system identified through simulations as having the highest performance potential. Presented here are the simulation results with various configurations of BF3 filled proportional counters, 10B lined proportional counters and 6Li/ZnS(Ag) sheets, and preliminary bench-top measurements.

Alternatives to Helium-3 for Neutron Multiplicity ↗

X-ray observations of LMC X-3 with the monitor proportional counter aboard the HEAO 2 Einstein observatory - A comparison with Cygnus X-1

A comparison is presented of the black hole candidates LMC X-3 and Cygnus X-1 based on Einstein observations of LMC X-3 with the monitor proportional counter. A spectral analysis shows LMC X-3 to be more like the typical bright galactic X-ray source than Cygnus X-1. A search for periodic pulsations over a period range from 0.2 ms to over 1000 s set upper limits at the 90 percent confidence level of the order of 10 percent. An analysis of the aperiodic variability of LMC X-3 shows none of the shot noise behavior characteristic of Cygnus X-1. The absence of distinctive X-ray properties common to both sources suggests that the identification of black hole candidates on the basis of X-ray properties similar to Cygnus X-1 (or LMC X-3) is not reliable.

Weisskopf, M. C.↗

Reciprocal regulation of extracellular signal regulated kinase 1/2 and mitogen activated protein kinase phosphatase-3

Mitogen activated protein kinase phosphatase-3 (MKP-3) is a putative tumor suppressor. When transiently overexpressed, MKP-3 dephosphorylates and inactivates extracellular signal regulated kinase (ERK) 1/2. Little is known about the roles of endogenous MKP-3, however. We previously showed that MKP-3 is upregulated in cell lines that express oncogenic Ras. Here we tested the roles of endogenous MKP-3 in modulating ERK1/2 under conditions of chronic stimulation of the Ras/Raf/MEK1/2/ERK1/2 pathway by expression of oncogenic Ras. We used two cell lines: H-ras MCF10A, breast epithelial cells engineered to express H-Ras, and DLD-1, colon cancer cells that express endogenous Ki-Ras. First, we found that MKP-3 acts in a negative feedback loop to suppress basal ERK1/2 when oncogenic Ras stimulates the Ras/Raf/MEK1/2/ERK1/2 cascade. ERK1/2 was required to maintain elevated MKP-3, indicative of a negative feedback loop. Accordingly, knockdown of MKP-3, via siRNA, increased ERK1/2 phosphorylation. Second, by using siRNA, we found that MKP-3 helps establish the sensitivity of ERK1/2 to extracellular activators by limiting the duration of ERK1/2 phosphorylation. Third, we found that the regulation of ERK1/2 by MKP-3 is countered by the complex regulation of MKP-3 by ERK1/2. Potent ERK1/2 activators stimulated the loss of MKP-3 within 30 min due to an ERK1/2-dependent decrease in MKP-3 protein stability. MKP-3 levels recovered within 120 min due to ERK1/2-dependent resynthesis. Preventing MKP-3 resynthesis, via siRNA, prolonged ERK1/2 phosphorylation. Altogether, these results suggest that under the pressure of oncogenic Ras expression, MKP-3 reins in ERK1/2 by serving in ERK1/2-dependent negative feedback pathways.

60 APPLIED LIFE SCIENCES↗

New-Generation Thermal Neutron Detectors and Electronics for High-Count-Rate Applications

Neutron measurements are important in many nonproliferation and treaty verification applications. Helium-3 proportional counters and analog electronics are the backbone of neutron detection systems. Helium-3 tubes with a 1-in. diameter have been used with classical electronics for over three decades because of the almost ideal behavior of the 3 He tube as a neutron detector. However, some demanding applications of 3 He tubes (high gamma dose rate, high count rate) and the use of non-ideal detectors (such as 10 B-lined proportional counters) mean that the limitations of these conventional systems are being reached. For example, neutron multiplicity deadtime corrections can be large, and some applications have had trouble with multiple pulsing. Also, instrumentation designs for spent fuel applications often rely on large amounts of lead shielding to reduce the gamma dose at the detector location, making them heavy and expensive. This major challenge for a short dead time and operation in high gamma fields is difficult to address by simply changing the gas admixture and tweaking the shaper time constants. Those small gains are adequate for measurements of some lower-burn-up, low-enrichment-uranium spent fuel assemblies, but not for mixed oxide (MOX) fuel or advanced fast reactor fuel, where the neutron source term is greater.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Well Counting Using New PSD Plastic Detectors

This report presents results and analysis from a series of proof-of-concept measurements to assess the suitability of segmented detectors constructed from Eljen EJ-299-34 PSD-plastic scintillator with pulse-shape discrimination capability for the purposes of quantifying uranium via active neutron coincidence counting. Present quantification of bulk uranium materials for international safeguards and domestic materials control and accounting relies on active neutron coincidence counting systems, such as the Active Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL), that use moderated He-3 proportional counters along with necessarily low-intensity 241Am(Li) neutron sources. Scintillation-based fast-neutron detectors are a potentially superior technology to the existing AWCC and UNCL designs due to their spectroscopic capability and their inherently short neutron coincidence times that largely eliminate random coincidences and enable interrogation by stronger sources. One of the past impediments to the investigation and adoption of scintillation counters for the purpose of quantifying bulk uranium was the commercial availability of scintillators having the necessary neutron-gamma pulse-shape discrimination properties only as flammable liquids. Recently, Eljen EJ-299-34 PSD-plastic scintillator became commercially available. The present work is the first assessment of an array of PSD-plastic detectors for the purposes of quantifying bulk uranium. The detector panel used in the present work was originally built as the focal plane for a fast-neutron imager, but it was repurposed for the present investigation by construction of a stand to support the inner well of an AWCC immediately in front of the detector panel. The detector panel and data acquisition of this system are particularly well suited for performing active-well fast-neutron counting of LEU and HEU samples because the active detector volume is solid, the 241Am(Li) interrogating neutrons are largely below the detector threshold, and the segmented construction of the detector modules allow for separation of true neutron-neutron coincidences from inter-detector scattering using the kinematics of neutron scattering. The results from a series of measurements of a suite of uranium standards are presented, and compared to measurements of the same standards and source configurations using the AWCC. Using these results, the performance of the segmented detectors reconfigured as a well counter is predicted and outperforms the AWCC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dietary n-3 PUFAs augment caspase 8 activation in Staphylococcal aureus enterotoxin B stimulated T-cells

Epidemiological studies have linked consumption of n-3 PUFAs with a variety of beneficial health benefits, particularly with respect to putative anti-inflammatory effects. Unfortunately, many of these results remain somewhat controversial because in most instances there has not been a linkage to specific molecular mechanisms. For instance, dietary exposure to low levels of mercury has been shown to be damaging to neural development, but concomitant ingestion of n-3 PUFAs as occurs during consumption of fish, has been shown to counteract the detrimental effects. As the mechanisms mediating the neurotoxicity of environmental mercury are not fully delineated, it is difficult to conceptualize a testable molecular mechanism explaining how n-3 PUFAs negate its neurotoxic effects. However, environmental exposure to mercury also has been linked to increased autoimmunity. By way of a molecular understanding of this immuno-toxic association, disruption of CD95 signaling is well established as a triggering factor for autoimmunity, and we have previously shown that environmentally relevant in vitro and dietary exposures to mercury interfere with CD95 signaling. In particular we have shown that activation of caspase 8, as well as downstream activation of caspase 3, in response to CD95 agonist stimulation is depressed by mercury. More recently we have shown in vitro that the n-3 PUFA docosahexaenoic acid counteracts the negative effect of mercury on CD95 signaling by restoring caspase activity. We hypothesized that concomitant ingestion of n-3 PUFAs with mercury might be protective from the immuno-toxic effects of mercury, as it is with mercury's neuro-toxic effects, and in the case of immuno-toxicity this would be related to restoration of CD95 signal strength. We now show that dietary ingestion of n-3 PUFAs generally promotes CD95 signaling by upregulating caspase 8 activation. Apart from accounting for the ability of n-3 PUFAs to specifically counteract autoimmune sequelae of mercury exposure, this novel finding for the first time suggests a testable molecular mechanism explaining the overall anti-inflammatory properties of n-3 PUFAs. - Highlights: • Dietary n-3 PUFAs counter Hg{sup 2+} immunotoxicity • Hg{sup 2+} interference with SEB-mediated signal transduction is ameliorated by n-3 PUFA rich diets. • Dietary n-3 PUFAs augment SEB-mediated activation of caspase 8 in vivo.

54 ENVIRONMENTAL SCIENCES↗

Imaging vs. non-imaging in long range neutron detection scenarios.

Standoff neutron detection technology has advanced in recent years, primarily for counterterrorism applications. Sandia National Laboratories has developed the Neutron Scatter Camera -- a fast neutron imaging system using liquid scintillator with potential applications in long range neutron detection. This talk will explore the pros, cons and practical uses of the Neutron Scatter Camera versus more traditional neutron detectors such as He-3 proportional counters. Several applications for neutron detection and imaging will be explored. We will perform predictive calculations of the response of the Neutron Scatter Camera and traditional He-3 detectors. The applications range from counterterrorism to arms control to safeguards. We will discuss future evolution of the scatter camera to enhance long range detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Generation Method of 24-keV Monoenergetic Neutrons Using Accelerators

This paper describes a novel 24-keV monoenergetic neutron source that consists of an iron filter and a thick lithium target. The 24 keV neutrons are obtained with iron filtering of a neutron beam from the {sup 7}Li(p,n){sup 7}Be reaction near threshold energy using the 4 MV Pelletron accelerator. Neutron spectra were calculated using the NRESP-ANT simulation code. This neutron source was investigated using a {sup 3}He cylindrical proportional counter to measure the spatial distribution and neutron flux.

43 PARTICLE ACCELERATORS↗

Neutron sensitivity and detection efficiency of {sup 3}He and {sup 10}BF{sub 3} counters

An analytic relationship between the efficiency, sensitivity, and the coefficient of working-isotope utilization is established for gas-filled cylindrical thermal-neutron counters. This dependence is expressed in terms of the ratio of the characteristic length of a counter to its diameter. The characteristic size is introduced as the ratio of the total absorption cross section to the length of the counter. The parameters of basic {sup 3}He and {sup 10}BF{sub 3} counters used in NM-64 neutron monitors are calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The predicted deviation from the Z-sq dependence of the ion chamber and the Cerenkov counter response on the HEAO-3 experiment

The influence of the Mott cross section in producing a departure from a Z-sq dependence in the Heavy Nuclei Experiment instrument on board the HEAO-3 satellite is examined, along with the related problem of secondary electron energy transport through the instrument. A Monte Carlo method of electron transport and a modification of the Laulainen and Bichsel (1972) method were used to calculate energy deposition in the chamber, and corrections to the Cerenkov counter response were made. A maximum correction of a change of Z values of a -4 at Z equals 78 was found, and further calculations to determine the Mott cross sections for Z between 26-50 are indicated.

Derrickson, J. H.↗

Pulsed D-D Neutron Generator Measurements of HEU Oxide Fuel Pins

Pulsed neutron interrogation measurements have been performed on highly enriched uranium (HEU) oxide fuel pins and depleted uranium (DU) metal using a D-D neutron generator (2x10{sup 6} neutrons-s{sup -1}) and moderated {sup 3}He tubes at the Idaho National Laboratory Power Burst Facility. These measurements demonstrate the ability to distinguish HEU from DU by coincidence counting using a pulsed source. The amount of HEU measured was 8 kg in a sealed 55-gallon drum compared to 31 kg of DU. Neutron events were counted during and after the pulse with the Nuclear Materials Identification System (NMIS) and used to calculate the neutron coincidence time distributions. Passive measurements were also performed for comparison with the pulsed measurements. This paper presents the neutron coincidence time distribution and Feynman variance results from the measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗