Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HCA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Data Validation for Hosting Capacity Analyses

The usefulness of Hosting Capacity Analysis (HCA) is dependent on users' confidence that the results accurately reflect grid conditions. This report provides the findings and recommendations from research, conducted by The National Renewable Energy Lab (NREL) and The Interstate Renewable Energy Council (IREC), into HCA data validation best practices. The goal is to provide utilities, regulators, and stakeholders best practices for HCA data validation procedures so that future HCA deployments avoid uncertainties and potential mistakes from earlier rollouts and provide useful and accurate data from the day they are published. Utilities can use this report to develop or refine their HCA data validation procedures. Regulators can use the report to inform their oversight of utilities' HCA data validation practices, while stakeholders can use it to evaluate the effectiveness of utility efforts.

14 SOLAR ENERGY↗

Impact of gasoline composition on the effects of nitric oxide on autoignition and knock in a DISI engine

Modern spark-ignition engines use exhaust gas recirculation (EGR) to dilute the charge and suppress knock, enabling the use of higher compression ratios and/or more optimum combustion phasing for higher efficiency. The effectiveness of EGR is affected by the composition of the fuel and its chemical-kinetic interactions with combustion products. Among those, nitric oxide (NO) has been shown to strongly affect autoignition reactivity. However, the impact of fuel composition of the effect of NO on reactivity is not well-understood. Here, in this study, engine experiments were conducted to assess the impact of NO seeded to the intake on knock-limited operation of two gasoline fuels (high cycloalkane content, or HCA, and high olefin content, or HO). Results showed that compositionally-different fuels responded differently to NO. HCA, which was less knock-limited than HO for NO < 200 ppm, became more knock-limited for NO > 200 ppm. Moreover, it was found that differences in knock between fuels were caused by differences in autoignition chemistry and not in the sequential autoignition process of the end gas that occurs due to thermal stratification. Chemical kinetic simulations were performed to better understand the experimental results. For HCA, intermediate-temperature heat release had a greater impact on autoignition reactivity than low-temperature heat release, while the opposite was observed for HO. For both fuels, NO enhances the magnitude of low-temperature heat release via NO + HO 2 → NO 2 + OH. The effect of NO on reactivity was stronger for HCA because OH produced from NO helped to overcome the OH quenching effect of cyclopentane, a main species in HCA. In contrast, HO had relatively strong inherent low-temperature chemistry arising from iso-octane, which reduced the impact of NO on reactivity. For the range of NO mole fractions tested in this study, in-cylinder NO increased fuel’s knock propensity, especially for fuels with mild low-temperature chemistry.

Autoignition↗

Effects of Gasoline Composition and Operating Parameters on the Response of End-Gas Autoignition to Nitric Oxide in a Lean-Burn DI-SI Engine

Lean operation of spark-ignition engines can lead to engine thermal efficiency gains and lower NOx emissions due to reduced combustion temperatures. Yet, lean operation could still face challenges in end-gas autoignition and knock generation due to higher intake pressures and trapped NO in the residual gas. Here, this study evaluates the impact of NO on end-gas autoignition for two gasoline fuels with similar octane rating but different composition: high cycloalkane fuel (HCA) and high olefin fuel (HO). Experiments were performed at stoichiometric and lean (λ = 2) conditions and at two engine speeds of 1400 rpm and 2000 rpm. Accompanying chemical kinetics simulations in CHEMKIN revealed that the mechanisms controlling the effect of NO on autoignition are similar λ = 2 and λ = 1, with NO + HO 2 = NO 2 + OH being the main pathway for enhancing reactivity by promoting low-temperature heat release (LTHR). The compositionally different fuels reacted differently to NO seeding and engine speed, and differences were augmented at λ = 2 compared to λ = 1 as the end-gas autoignition shifted to the low temperature regime. HO, which has inherent low temperature chemistry, was strongly impacted by engine speed at low NO seeding levels, with no noticeable peak of LTHR detected at 2000 rpm. On the other hand, LTHR of HCA was marginally affected by shortened residence time at higher engine speed as NO + HO 2 reaction was not greatly affected by shorter time scales, since HO 2 production was sustained even at 2000 rpm to support OH generation from NO + HO 2 . Contrary to HO, HCA exhibited greater sensitivity to NO seeding, as the increased OH production at higher NO concentrations offset the OH-quenching effect of cyclopentane, which accounts for 28.6% of HCA’s composition. Consequently, a sensitivity analysis revealed that fuels with weak inherent low-temperature chemistry, like HCA, are likely to be more sensitive to variations in NO concentration and charge temperature, whereas fuels with strong low temperature chemistry are more sensitive to variations in end-gas λ and intake pressure.

Energy↗

Data Validation for Hosting Capacity Analyses: Executive Summary

The usefulness of Hosting Capacity Analysis (HCA) is dependent on users' confidence that the results accurately reflect grid conditions. This report provides the findings and recommendations from research, conducted by The National Renewable Energy Lab (NREL) and The Interstate Renewable Energy Council (IREC), into HCA data validation best practices. The goal is to provide utilities, regulators, and stakeholders best practices for HCA data validation procedures so that future HCA deployments avoid uncertainties and potential mistakes from earlier rollouts and provide useful and accurate data from the day they are published.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast Iterative Multi-site Hosting Capacity Analysis for Distribution Systems With Search Space Pruning

Interconnection studies for distributed energy resources (DERs) is a time-intensive process, primarily due to the necessity of solving large number of power flow scenarios. Hosting capacity analysis (HCA) is a time-consuming aspect of interconnection studies that is divided into single-site HCA (SHCA) and multi-site HCA (MHCA). From a computational and understandable standpoint, the industry seeks iteration-based solutions for SHCA, although it doesn't maximize the total DER hosting capacity (DERHC) of the grid, as MHCA does. While non-iterative solutions are available for MHCA, they involve a trade-off between the modeling accuracy of the distribution system, solution quality, and ease of understanding. In this work, we present a fast iterative solution for MHCA, reducing computational complexity by eliminating the need to solve power flows for a large amount of search space, thus making iterative solutions feasible. This iterative approach guarantees both a global optimal solution with sufficient time and a fast, close-to-optimal solution through efficient search space pruning. It also easily integrates with existing utility HCA tools. The results are demonstrated on select locations in the IEEE-123 bus system for community-scale interconnection studies. We highlight the benefits of skipping the need to solve millions of power flows, all while maximizing the grid's total DERHC.

Guddanti, Kishan Prudhvi↗

H-Canyon Jumper Gasket Sealing Evaluation

H-Canyon Documented Safety Analysis approved December 2019 credits the leak integrity of H-Canyon (HCA) process tanks, piping, and jumpers in preventing the release of radioactive material in a post seismic environment. Demonstration of leak tightness capability for this equipment was achieved through substantial analytical effort. However, one potential weak point that affects leak integrity exists at the gasketed joint between Hanford Connectors (HC) and nozzles. Review of the HCA Crane Log over a three-year period indicates the HCs periodically leak. Savannah River National Laboratory (SRNL) was requested to perform gasket compression tests that evaluate gasket relaxation characteristics, i.e., creep, and provide improvements to the HC installation process that can reduce or eliminate the frequency of leaks at HCs. A HC torque value of 312 ft-lbf is the target value used because it is the minimum torque value, with 95% confidence, when an unlubricated HC is impacted for standard sealing period of 9 seconds. In the HCA pipe-jumper connections are installed remotely by using HCs. HCs inherently add to the uncertainty of a gasketed joint because a calibrated torque value cannot be applied. The gasket material is a special material made of asbestos-fiber impregnated with Teflon. This material has been used for decades and generally performs well but does leak intermittently as gaskets creep and preloaded torque is lost. Gasket types are either snap-ring (SR) or lampshade (LS). Both gasket types cover the same seating area. The SR gasket is designed to remain with the jumper when the jumper is removed leaving the nozzle faces clean of any debris. SR gaskets are initially installed when the jumper is fabricated. Changing gaskets is time consuming and the radioactive environment presents risks to personnel. When jumpers are removed LS gaskets could be used to better seal the connection to reduce down time and ALARA concerns. That is, an LS gasket would be remotely positioned over the nozzle and the HC reinstalled. Testing also included two situations not typical of plant operation. One situation was the use of the non-standard double-layered gaskets (DG), and the other situation was the use of a LS without removal of the installed SR gasket. The DG was used when the supply of LS gaskets ended, so that testing could continue. It was of interest to demonstrate this gasket’s creep response because the DG, which was two gaskets glued together, was thicker than the LS gasket and the thicker material was expected to elicit a greater creep characteristics. The second situation of using two gaskets together by installing an LS gasket without removing the installed gasket is not allowed by the ASME Codes. However, by demonstrating the creep history of such a gasket arrangement it could be considered as an option that could possibly seal a connection while significantly reducing operational down time and personnel risk. Forty tests were conducted, and the overall results demonstrate the initial applied force and how the gasket changes with time. The change in sealing force, in terms of torque, was then measured to obtain a force history as the gaskets creep. This report documents the results of those tests as well as the method used to perform the tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Human Carbonic Anhydrase II Heterobifunctional Degraders

Human carbonic anhydrase II (hCAII) is a metalloenzyme essential to critical physiological processes in the body. hCA inhibitors are used clinically for the treatment of indications ranging from glaucoma to epilepsy. Targeted protein degraders have emerged as a promising means of inducing the degradation of disease-implicated proteins by using the endogenous quality control mechanisms of a cell. Here, a series of heterobifunctional degrader candidates targeting hCAII were developed from a simple aryl sulfonamide fragment. Degrader candidates were functionalized to produce either cereblon E3 ubiquitin ligase (CRBN) recruiting proteolysis targeting chimeras (PROTACs) or adamantyl-based hydrophobic tags (HyTs). Screens in HEK293 cells identified two PROTAC small-molecule degraders of hCA. Optimization of linker length and composition yielded a degrader with sub-nanomolar potency and sustained depletion of hCAII over prolonged treatments. Mechanistic studies suggest that this optimized degrader depletes hCAII through the same mechanism as previously reported CRBN-recruiting heterobifunctional degraders.

60 APPLIED LIFE SCIENCES↗

H-Canyon Jumper Gasket Sealing Evaluation

H-Canyon Documented Safety Analysis approved December 2019 credits the leak integrity of HCanyon (HCA) process tanks, piping, and jumpers in preventing the release of radioactive material in a post seismic environment. Demonstration of leak tightness capability for this equipment was achieved through substantial analytical effort. However, one potential weak point that affects leak integrity exists at the gasketed joint between Hanford Connectors (HC) and nozzles. Review of the HCA Crane Log over a three-year period indicates the HCs periodically leak. Savannah River National Laboratory (SRNL) was requested to perform gasket compression tests that evaluate gasket relaxation characteristics, i.e., creep, and provide improvements to the HC installation process that can reduce or eliminate the frequency of leaks at HCs. A HC torque value of 312 ft-lbf is the target value used because it is the minimum torque value, with 95% confidence, when an unlubricated HC is impacted for standard sealing period of 9 seconds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building a FAIR data ecosystem for incorporating single-cell transcriptomics data into agricultural genome to phenome research

Introduction The agriculture genomics community has numerous data submission standards available, but the standards for describing and storing single-cell (SC, e.g., scRNA- seq) data are comparatively underdeveloped. Methods To bridge this gap, we leveraged recent advancements in human genomics infrastructure, such as the integration of the Human Cell Atlas Data Portal with Terra, a secure, scalable, open-source platform for biomedical researchers to access data, run analysis tools, and collaborate. In parallel, the Single Cell Expression Atlas at EMBL-EBI offers a comprehensive data ingestion portal for high-throughput sequencing datasets, including plants, protists, and animals (including humans). Developing data tools connecting these resources would offer significant advantages to the agricultural genomics community. The FAANG data portal at EMBL-EBI emphasizes delivering rich metadata and highly accurate and reliable annotation of farmed animals but is not computationally linked to either of these resources. Results Herein, we describe a pilot-scale project that determines whether the current FAANG metadata standards for livestock can be used to ingest scRNA-seq datasets into Terra in a manner consistent with HCA Data Portal standards. Importantly, rich scRNA-seq metadata can now be brokered through the FAANG data portal using a semi-automated process, thereby avoiding the need for substantial expert curation. We have further extended the functionality of this tool so that validated and ingested SC files within the HCA Data Portal are transferred to Terra for further analysis. In addition, we verified data ingestion into Terra, hosted on Azure, and demonstrated the use of a workflow to analyze the first ingested porcine scRNA-seq dataset. Additionally, we have also developed prototype tools to visualize the output of scRNA-seq analyses on genome browsers to compare gene expression patterns across tissues and cell populations. This JBrowse tool now features distinct tracks, showcasing PBMC scRNA-seq alongside two bulk RNA-seq experiments. Discussion We intend to further build upon these existing tools to construct a scientist-friendly data resource and analytical ecosystem based on Findable, Accessible, Interoperable, and Reusable (FAIR) SC principles to facilitate SC-level genomic analysis through data ingestion, storage, retrieval, re-use, visualization, and comparative annotation across agricultural species.

Genetics & Heredity↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charge Transfer Dynamics in Dye-Sensitized Photocatalysts Using Metal Complex Sensitizers with Long-Wavelength Visible Light Absorption Based on Singlet–Triplet Excitation

An Os(II) polypyridyl complex was applied as a photosensitizer in dye-sensitized photocatalyst systems based on Pt-intercalated HCa 2 Nb 3 O 10 and Pt-loaded TiO 2 . The Os(II) complex exhibits a spin-forbidden but partially allowed triplet metal-to-ligand charge transfer ( 3 MLCT) transition, enabling broad visible light absorption up to 800 nm, which surpasses that of conventional Ru(II)-based dyes. Despite its shorter excited-state lifetime compared to Ru(II) complexes, efficient electron injection from the excited Os(II) dye into the semiconductor was confirmed. Under visible-light irradiation, the Os(II)- sensitized photocatalysts showed higher H 2 evolution activity than the Ru(II)-sensitized photocatalysts when sodium ascorbate was used as an electron donor, demonstrating effective utilization of long-wavelength visible light. In contrast, negligible H 2 evolution was observed when NaI was employed as a redox mediator for Z-scheme water splitting. Transient absorption spectroscopy revealed that the lack of activity stemmed from inefficient electron transfer from I − to oxidized Os(II). These findings highlight the importance of selecting appropriate redox mediators to fully exploit long-wavelength dyes for overall water splitting under visible light.

artificial photosynthesis↗

Surface-modified, dye-sensitized niobate nanosheets enabling an efficient solar-driven Z-scheme for overall water splitting

While dye-sensitized metal oxides are good candidates as H 2 evolution photocatalysts for solar-driven Z-scheme water splitting, their solar-to-hydrogen (STH) energy conversion efficiencies remain low because of uncontrolled charge recombination reactions. Here, we show that modification of Ru dye–sensitized, Pt-intercalated HCa 2 Nb 3 O 10 nanosheets ( Ru /Pt/HCa 2 Nb 3 O 10 ) with both amorphous Al 2 O 3 and poly(styrenesulfonate) (PSS) improves the STH efficiency of Z-scheme overall water splitting by a factor of ~100, when the nanosheets are used in combination with a WO 3 -based O 2 evolution photocatalyst and an I 3 - /I - redox mediator, relative to an analogous system that uses unmodified Ru /Pt/HCa 2 Nb 3 O 10 . By using the optimized photocatalyst, PSS/ Ru /Al 2 O 3 /Pt/HCa 2 Nb 3 O 10 , a maximum STH of 0.12% and an apparent quantum yield of 4.1% at 420 nm were obtained, by far the highest among dye-sensitized water splitting systems and comparable to conventional semiconductor-based suspended particulate photocatalyst systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Review and Revalidation of Equivalency Factors in H-Canyon

In recent years, an effort has begun to validate and reaffirm long-existing limits and equivalency factors in use at the H-Canyon (HCA) facility located at the Savanah River Site. Equivalency factors (EF) are coefficients used to express the reactivity of a quantity of a given isotope in terms of an equivalent amount of another isotope’s reactivity, commonly termed Fissile Gram Equivalent (FGE). For criticality safety purposes, EFs are often used to conservatively determine if a given mixed-isotope system is within previously established limits. These EFs are calculated by taking ratios of established subcritical limits for a given system or process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data Validation for Hosting Capacity Analyses [Slides]

The National Renewable Energy Laboratory (NREL), in partnership with the Interstate Renewable Energy Council (IREC), has recently released a report which identifies a suite of best practices for producing trusted, validated hosting capacity analysis results reflecting real-world grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗