Engineering PapersSearch

SEARCH · Engineering Papers

Results for “HARMONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Balancing Vibrations at Harmonic Frequencies by Injecting Harmonic Balancing Signals into the Armature of a Linear Motor/Alternator Coupled to a Stirling Machine

Vibrations at harmonic frequencies are reduced by injecting harmonic balancing signals into the armature of a linear motor/alternator coupled to a Stirling machine. The vibrations are sensed to provide a signal representing the mechanical vibrations. A harmonic balancing signal is generated for selected harmonics of the operating frequency by processing the sensed vibration signal with adaptive filter algorithms of adaptive filters for each harmonic. Reference inputs for each harmonic are applied to the adaptive filter algorithms at the frequency of the selected harmonic. The harmonic balancing signals for all of the harmonics are summed with a principal control signal. The harmonic balancing signals modify the principal electrical drive voltage and drive the motor/alternator with a drive voltage component in opposition to the vibration at each harmonic.

Holliday, Ezekiel S.

Relation of squeezed states between damped harmonic and simple harmonic oscillators

The minimum uncertainty and other relations are evaluated in the framework of the coherent states of the damped harmonic oscillator. It is shown that the coherent states of the damped harmonic oscillator are the squeezed coherent states of the simple harmonic oscillator. The unitary operator is also constructed, and this connects coherent states with damped harmonic and simple harmonic oscillators.

Um, Chung-In

Geomagnetic main field analysis at the core-mantle boundary - Spherical harmonics compared with harmonic splines

An optimum truncation level, N, in a spherical-harmonic analysis of the geomagnetic main field at the core-mantle boundary is determined by harmonic-spline analysis. Specifically, that value of N is found at which the two analyses are closest in a well defined sense and, for that value of N, the 'closeness' of two models is determined. Depending slightly on the definition of closeness, optimum N is found to be either 10 or 11. For those values the two analyses give remarkably similar results, showing that the conveniences of spherical harmonics can be retained with little penalty.

Benton, E. R.

Maximizing Earth Science Observations with Data Harmonization: Harmonized Landsat/Sentinel-2

In August 2021, NASA released science quality harmonized Landsat/Sentinel-2 products for both cloud-based access and direct download from the Land Processes Distributed Active Archive Center (LP DAAC). These 30-meter products, HLSS30 (Sentinel-2 component) and HLSL30 (Landsat component) are placed on the same grid and are generated and distributed fully in the cloud. Similarly, ESA is prototyping harmonized Landsat Sentinel-2 products at 10-meter resolution. The data production and science teams from NASA and ESA will present technical details on the data production system, data product status and availability, and the benefit of harmonizing instruments with similar sensing characteristics between the agencies.

Earth Science

Dark Energy Survey Year 3 results: Simulation-based cosmological inference with wavelet harmonics, scattering transforms, and moments of weak lensing mass maps. II. cosmological results

Here, we present a simulation-based cosmological analysis using a combination of Gaussian and non-Gaussian statistics of the weak lensing mass (convergence) maps from the first three years of the Dark Energy Survey. We implement the following: (1) second and third moments; (2) wavelet phase harmonics; (3) the scattering transform. Our analysis is fully based on simulations, spans a space of seven 𝑤 Cold Dark Matter (𝑤⁢ CDM) cosmological parameters, and forward models the most relevant sources of systematics inherent in the data: masks, noise variations, clustering of the sources, intrinsic alignments, and shear and redshift calibration. We implement a neural network compression of the summary statistics, and we estimate the parameter posteriors using a simulation-based inference approach. Including and combining different non-Gaussian statistics is a powerful tool that strongly improves constraints over Gaussian statistics (in our case, the second moments); in particular, the figure of merit (𝑆 8 , Ω m ) is improved by 70% (Λ ⁢CDM) and 90% (𝑤 ⁢CDM). When all the summary statistics are combined, we achieve a 2% constraint on the amplitude of fluctuations parameter 𝑆 8 ≡ 𝜎 8 ⁢(Ω m /0.3) 0.5 , obtaining 𝑆 8 = 0.794 ±0.017 (Λ⁢ CDM) and 𝑆 8 = 0.817 ±0.021 (𝑤 ⁢CDM), and a ∼10% constraint on Ω m , obtaining Ω m =0.259 ±0.025 (Λ ⁢CDM) and Ω m = 0.273 ±0.029 (𝑤⁢ CDM). In the context of the 𝑤⁢ CDM scenario, these statistics also strengthen the constraints on the parameter 𝑤, obtaining 𝑤 <−0.72. The constraints from different statistics are shown to be internally consistent (with a 𝑝-value>0.1 for all combinations of statistics examined). We compare our results to other weak lensing results from the first three years of the Dark Energy Survey data, finding good consistency; we also compare with results from external datasets, such as planck constraints from the cosmic microwave background, finding statistical agreement, with discrepancies no greater than <2.2⁢𝜎.

79 ASTRONOMY AND ASTROPHYSICS

Covariant harmonic oscillators and coupled harmonic oscillators

It is shown that the system of two coupled harmonic oscillators shares the basic symmetry properties with the covariant harmonic oscillator formalism which provides a concise description of the basic features of relativistic hadronic features observed in high-energy laboratories. It is shown also that the coupled oscillator system has the SL(4,r) symmetry in classical mechanics, while the present formulation of quantum mechanics can accommodate only the Sp(4,r) portion of the SL(4,r) symmetry. The possible role of the SL(4,r) symmetry in quantum mechanics is discussed.

Han, Daesoo

Harmonic drive gear error: Characterization and compensation for precision pointing and tracking

Imperfections and geometry effects in harmonic drive gear reducers cause a cyclic gear error, which at a systems level, results in high frequency torque fluctuations. To address this problem, gear error testing was performed on a wide variety of sizes and types of harmonic drives. It was found that although all harmonic drives exhibit a significant first harmonic, higher harmonics varied greatly with each unit. From life tests, small changes were found in harmonic content, phase shift, and error magnitude (on the order of .008 deg peak-to-peak maximum) occurred for drives with many millions of degrees of output travel. Temperature variations also influenced gear error. Over a spread of approximately 56 C (100 F), the error varied in magnitude approximately 20 percent but changes in a repeatable and predictable manner. Concentricity and parallelness tests of harmonic drive parts resulted in showing alignment influence gear error amplitude. Tests on dedoidaled harmonic drives showed little effect on gear error; surprisingly, in one case for a small drive, gear error actually improved. Electronic compensation of gear error in harmonic drives was shown to be substantially effective for units that are first harmonic dominant.

Nye, Ted W.

The Local Stellar Velocity Field via Vector Spherical Harmonics

We analyze the local field of stellar tangential velocities for a sample of 42,339 nonbinary Hipparcos stars with accurate parallaxes, using a vector spherical harmonic formalism. We derive simple relations between the parameters of the classical linear model (Ogorodnikov-Milne) of the local systemic field and low-degree terms of the general vector harmonic decomposition. Taking advantage of these relationships, we determine the solar velocity with respect to the local stars of (V(sub X), V(sub Y), V(sub Z)) (10.5, 18.5, 7.3) +/- 0.1 km s(exp -1) not corrected for the asymmetric drift with respect to the local standard of rest. If only stars more distant than 100 pc are considered, the peculiar solar motion is (V(sub X), V(sub Y), V(sub Z)) (9.9, 15.6, 6.9) +/- 0.2 km s(exp -1). The adverse effects of harmonic leakage, which occurs between the reflex solar motion represented by the three electric vector harmonics in the velocity space and higher degree harmonics in the proper-motion space, are eliminated in our analysis by direct subtraction of the reflex solar velocity in its tangential components for each star. The Oort parameters determined by a straightforward least-squares adjustment in vector spherical harmonics are A=14.0 +/- 1.4, B=13.1 +/- 1.2, K=1.1 +/- 1.8, and C=2.9 +/- 1.4 km s(exp -1) kpc(exp -1). The physical meaning and the implications of these parameters are discussed in the framework of a general linear model of the velocity field. We find a few statistically significant higher degree harmonic terms that do not correspond to any parameters in the classical linear model. One of them, a third-degree electric harmonic, is tentatively explained as the response to a negative linear gradient of rotation velocity with distance from the Galactic plane, which we estimate at approximately -20 km s(exp -1) kpc(exp -1). A similar vertical gradient of rotation velocity has been detected for more distant stars representing the thick disk (z greater than 1 kpc), but here we surmise its existence in the thin disk at z less than 200 pc. The most unexpected and unexplained term within the Ogorodnikov-Milne model is the first-degree magnetic harmonic, representing a rigid rotation of the stellar field about the axis -Y pointing opposite to the direction of rotation. This harmonic comes out with a statistically robust coefficient of 6.2 +/- 0.9 km s(exp -1) kpc(exp -1) and is also present in the velocity field of more distant stars. The ensuing upward vertical motion of stars in the general direction of the Galactic center and the downward motion in the anticenter direction are opposite to the vector field expected from the stationary Galactic warp model.

Galaxy

Harmonics of 60 Hz in power systems caused by geomagnetic disturbances

Simultaneous VLF/ULF observations carried out near Winnipeg, Manitoba show that geomagnetic disturbances control the behavior of harmonics of 60 Hz man-made electric power. The harmonics of 60 Hz detected by the VLF receiver are at multiples of 180 Hz, indicating that they originated from a 3 phase ac power system. Under geomagnetically quiet conditions, only odd harmonics of 70 Hz were detected. In disturbed conditions, both odd and even harmonics were excited. The strength of each harmonic changed concurrently with geomagnetic pulsation (ULF) activity. These findings seem to indicate that a portion of telluric currents shunted into the power line system through the neutrals of the Y-connected transformers give rise to a dc bias to the transformer core materials and that it distorts their hysteresis loops, activating harmonics of 60 Hz power. A mathematical proof is given that a hysteresis loop having a point of symmetry generates odd harmonics only, whereas loops lacking in point-symmetry generally give rise to both odd and even harmonics. A general formula was obtained to calculate the strength of each harmonic based on the shape of the hysteresis loop.

Hayashi, K.

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center

Multimode Directional Coupler for Utilization of Harmonic Frequencies from TWTAs

A novel waveguide multimode directional coupler (MDC) intended for the measurement and potential utilization of the second and higher order harmonic frequencies from high-power traveling wave tube amplifiers (TWTAs) has been successfully designed, fabricated, and tested. The design is based on the characteristic multiple propagation modes of the electrical and magnetic field components of electromagnetic waves in a rectangular waveguide. The purpose was to create a rugged, easily constructed, more efficient waveguide- based MDC for extraction and exploitation of the second harmonic signal from the RF output of high-power TWTs used for space communications. The application would be a satellitebased beacon source needed for Qband and V/W-band atmospheric propagation studies. The MDC could function as a CW narrow-band source or as a wideband source for study of atmospheric group delay effects on highdata- rate links. The MDC is fabricated from two sections of waveguide - a primary one for the fundamental frequency and a secondary waveguide for the second harmonic - that are joined together such that the second harmonic higher order modes are selectively coupled via precision- machined slots for propagation in the secondary waveguide. In the TWTA output waveguide port, both the fundamental and the second harmonic signals are present. These signals propagate in the output waveguide as the dominant and higher order modes, respectively. By including an appropriate mode selective waveguide directional coupler, such as the MDC presented here at the output of the TWTA, the power at the second harmonic can be sampled and amplified to the power level needed for atmospheric propagation studies. The important conclusions from the preliminary test results for the multimode directional coupler are: (1) the second harmonic (Ka-band) can be measured and effectively separated from the fundamental (Ku-band) with no coupling of the latter, (2) power losses in the fundamental frequency are negligible, and (3) the power level of the extracted second harmonic is sufficient for further amplification to power levels needed for practical applications. It was also demonstrated that third order and potentially higher order harmonics are measurable with this device. The design is frequency agnostic, and with the appropriate choice of waveguides, is easily scaled to higher frequency TWTs. The MDC has the same function but with a number of important advantages over the conventional diplexer.

Simmons, Rainee N.

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]

Determination of rotor harmonic blade loads from acoustic measurements

The magnitude of discrete frequency sound radiated by a rotating blade is strongly influenced by the presence of a nonuniform distribution of aerodynamic forces over the rotor disk. An analytical development and experimental results are provided for a technique by which harmonic blade loads are derived from acoustic measurements. The technique relates, on a one-to-one basis, the discrete frequency sound harmonic amplitudes measured at a point on the axis of rotation to the blade-load harmonic amplitudes. This technique was applied to acoustic data from two helicopter types and from a series of test results using the NASA-Langley Research Center rotor test facility. The inferred blade-load harmonics for the cases considered tended to follow an inverse power law relationship with harmonic blade-load number. Empirical curve fits to the data showed the harmonic fall-off rate to be in the range of 6 to 9 db per octave of harmonic order. These empirical relationships were subsequently used as input data in a compatible far field rotational noise prediction model. A comparison between predicted and measured off-axis sound harmonic levels is provided for the experimental cases considered.

Kasper, P. K.