Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “H- source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Control system for the Spallation Neutron Source H{sup -} source test facility Allison scanner

Spallation Neutron Source is currently in progress of a multiyear plan to ramp ion beam power to the initial design power of 1.4 MW. Key to reaching this goal is understanding and improving the operation of the H{sup -} ion source. An Allison scanner was installed on the ion source in the test facility to support this improvement. This paper will discuss the hardware and the software control system of the installed Allison scanner. The hardware for the system consists of several parts. The heart of the system is the scanner head, complete with associated bias plates, slits, and signal detector. There are two analog controlled high voltage power supplies to bias the plates in the head, and a motor with associated controller to position the head in the beam. A multifunction data acquisition card reads the signals from the signal detector, as well as supplies the analog voltage control for the power supplies. To synchronize data acquisition with the source, the same timing signal that is used to trigger the source itself is used to trigger data acquisition. Finally, there is an industrial personal computer to control the rest of the hardware. Control software was developed using National Instruments LABVIEW, and consists of two parts: a data acquisition program to control the hardware and a stand alone application for offline user data analysis.

43 PARTICLE ACCELERATORS↗

H{sup -} radio frequency source development at the Spallation Neutron Source

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

43 PARTICLE ACCELERATORS↗

rf improvements for Spallation Neutron Source H{sup -} ion source

The Spallation Neutron Source at Oak Ridge National Laboratory is ramping up the accelerated proton beam power to 1.4 MW and just reached 1 MW. The rf-driven multicusp ion source that originates from the Lawrence Berkeley National Laboratory has been delivering {approx}38 mA H{sup -} beam in the linac at 60 Hz, 0.9 ms. To improve availability, a rf-driven external antenna multicusp ion source with a water-cooled ceramic aluminum nitride (AlN) plasma chamber is developed. Computer modeling and simulations have been made to analyze and optimize the rf performance of the new ion source. Operational statistics and test runs with up to 56 mA medium energy beam transport beam current identify the 2 MHz rf system as a limiting factor in the system availability and beam production. Plasma ignition system is under development by using a separate 13 MHz system. To improve the availability of the rf power system with easier maintenance, we tested a 70 kV isolation transformer for the 80 kW, 6% duty cycle 2 MHz amplifier to power the ion source from a grounded solid-state amplifier.

43 PARTICLE ACCELERATORS↗

Ramping Up the SNS Beam Power with the LBNL Baseline H- source

LBNL designed and built the Frontend for the Spallation Neutron Source, including its H- source and Low-Energy Beam Transport (LEBT). This paper discusses the performance of the H- source and LEBT during the commissioning of the accelerator, as well as their performance while ramping up the SNS beam power to 540 kW. Detailed discussions of major shortcomings and their mitigations are presented to illustrate the effort needed to take even a well-designed R&D ion source into operation. With these modifications, at 4% duty factor the LBNL H- source meets the essential requirements that were set at the beginning of the project.

43 PARTICLE ACCELERATORS↗

Ramping up the SNS Beam Power with the H- Source using 0 mg Cs/Day

This paper describes the ramp up of the beam power for the Spallation Neutron Source by ramping up the pulse length, the repetition rate, and the beam current emerging from the H- source. Starting out with low rep rates (<10 Hz) and short pulse lengths (<<0.3 ms) the H- source and LEBT delivered from LBNL exceeded the requirements with almost perfect availability. This paper discusses the modifications that were required to exceed 0.2 ms pulse length and 0.2% duty factor with acceptable availability and performance. Currently the source is supporting neutron production at 1 MW with 38 mA LINAC beam current at 60 Hz and 0.9 ms pulse length. The pulse length will be increased to ~1.1 ms to meet the requirements for neutron production with a power between 1 and 1.4 MW. A MEBT beam current of 46 mA with a 5.4% duty factor has been demonstrated for 32 hours. A 56mA MEBT beam current with a 4.1% duty factor has been demonstrated for 20 minutes at the conclusion of a 12 day production run. This is close to the 59 mA needed for 3 MW neutron productions. Also notable is the Cs2CrO4 cesium system, which dispenses ~10 mg of Cs during the startup of the ion source, sufficient for producing the required 38 mA for 4 weeks without significant degradation.

H- source↗

RAMPING UP THE SNS BEAM CURRENT WITH THE LBNL BASELINE H- SOURCE

Over the last two years the Spallation Neutron Source (SNS) has ramped up the repetition rate, pulse length, and the beam current to reach 540 kW, which has challenged many subsystems including the H- source designed and built by Lawrence Berkeley National Laboratory (LBNL). This paper discusses the major modifications of the H- source implemented to consistently and routinely output the beam current required by the SNS beam power ramp up plan. At this time, 32 mA LINAC beam current are routinely produced, which meets the requirement for 690 kW planned for end of 2008. In June 2008, a 14-day production run used 37 mA, which is close to the 38 mA required for 1.44 MW. A medium energy beam transport (MEBT) beam current of 46 mA was demonstrated on September 2, 2008.

43 PARTICLE ACCELERATORS↗

Detection of an extended soft X-ray source H 2326-79 in the southern sky

A new extended soft X-ray source H 2326-79 has been detected with the low energy detectors of the HEAO1 A-2 experiment. The source is found to have a size of approximately 2.5 arcsec and is centered at RA(1950)=23 h 26 m, Decl.(1950)= -79 deg 24 min. The observed energy flux, seen mainly in the 0.18-0.4 keV band, corrected for finite source size, is found to be about 2.6 x 10 to the -11th erg/sq cm-sec. It is determined that the source spectrum fits well with either an exponential model (gaunt factor included) or with a Raymond Smith plasma model. The observed characteristics of the source are studied for two physical models: a very old low surface brightness supernova remnant undetected in the radio and optical regions, and an enhanced X-ray emission region surrounding an H I cloud embedded in the hot cavity of Loop I. The observed source is also interpreted as a group of two or more unresolved stellar X-ray sources.

Agrawal, P. C.↗

A 15 mA CW H- Source for Accelerators

A cw surface-plasma type negative ion source has been developed. H- beam with current 15 mA and energy of 32 keV is regularly produced in the runs with duration >10{sup 2} hours. Unattended operation of the source under computer control is realized. The source has a simplified maintenance and an easy access to consumable parts.

43 PARTICLE ACCELERATORS↗

Record Performance of and Extraction Studies with the Spallation Neutron Source H- Injector

During the past year the Spallation Neutron Source has operated with proton beam powers up to 1.4 MW with good availability. However, after a recent premature target failure the power was reduced to 1 MW for the ~20-week service cycle of the new target, whereas the subsequent target will be used at 1.2 MW. The ion source and low-energy beam transport deliver 50 to 60 mA H- beams into the RFQ with availbilities of ~99.5%. The compromised RFQ transmission limits the LINAC beam to ~35 mA, which is sufficient for 1.4 MW. Our current injector efforts focus on improving reliability and increasing the source service cycles beyond the achived 7 A·h to reduce the venting of the RFQ and to improve the stability of the accelerator operations. In addition, extraction studies show that higher extraction fields improve the RFQ transmission, apparently due to a reduced emittance of the LEBT H- beams.

Stockli, Martin P.↗

Recent Performance of the SNS H-Source for 1-MW Neutron Production

This paper describes the performance of the SNS ion source and LEBT as they continue to deliver ~50 mA H- beams at a 5.3% duty factor required for neutron production with a ~1MW proton beam since the fall of 2009. The source continues to deliver persistent H- beams for up to 6 weeks without adding Cs after an initial dose of ~4 mg, except when there are excessive plasma impurities. In one case the H- beam decayed due to an air leak, which is shown to be consistent with sputtering of the Cs layer, and which allows to bracket the plasma potential. In another case, the performance of two sources degraded progressively, which appears to be consistent with a progressive deterioration of the Cs covered Mo converter. These two and other recently discovered issues are discussed in detail.

Cesium↗

Optimization of the cesiation process for the spallation neutron source (SNS) H - ion sources

RF-driven (internal and external antenna), Cs-enhanced H - ion sources at the Spallation Neutron Source (SNS) facility are capable of producing high current (>60 mA), high duty-factor (1 ms, 60 Hz) H - beams lasting multiple months. A solid reaction Cs dispenser system is used to cesiate the ion source. This work reports on our continuous effort to optimize the ion source cesiation process guided by the Cs signal observed with the plasma emission spectroscopy to mitigate the Cs induced high voltage sparking while assuring to enable high H - beam currents

Han, Baoxi↗

Plasma emission spectroscopy for operating and developing the Spallation Neutron Source (SNS) H- ion sources

An RF-driven, Cs-enhanced H- ion source feeds the SNS accelerator with a high current (typically >50 mA), ~1.0 ms pulsed beam at 60 Hz. To achieve the persistent high current beam for several weeks long service cycles, each newly installed ion source undergoes a rigorous conditioning and cesiation processes. Plasma conditioning outgases the system and sputter-cleans the ion conversion surfaces. A cesiation process immediately following the plasma conditioning releases Cs to provide coverage on the ion conversion surfaces. The effectiveness of the ion source conditioning and cesiation is monitored with plasma emission spectroscopy using a high-sensitivity optical spectrometer. Plasma emission spectroscopy is also used to provide a mean for diagnosing and confirming a failure of the insulating coating of the ion source RF antenna which is immersed in the plasma. Emissions of composition elements of the antenna coating material, Na emission being the most significant, drastically elevate to signal a failure when it happens. Plasma spectra of the developmental ion source with an AlN chamber and an external RF antenna are also briefly discussed.

Han, Baoxi↗

Control System for the SNS H- Source Test Stand Allison Scanner

SNS is currently in progress of a multi-year plan to ramp ion beam power to the initial design power of 1.4 MW. Key to reaching this goal is understanding and improving the operation of the H- ion source. An Allison scanner was installed on the ion source test stand to support this improvement. This paper will discuss the hardware and the software control system of the installed Allison scanner. The hardware for the system consists of several parts. The heart of the system is the scanner head, complete with associated bias plates, slits, and signal detector. There are two analog controlled high voltage power supplies to bias the plates in the head, and a motor with associated controller to position the head in the beam. A multifunction data acquisition card reads the signals from the signal detector, as well as supplying the analog voltage control for the power supplies. To synchronize data acquisition with the source, the same timing signal that is used to trigger the source itself is used to trigger data acquisition. Finally, there is an industrial PC to control the rest of the hardware. Control software was developed using National Instruments LabVIEW, and consists of two parts, a data acquisition program to control the hardware, and a stand alone application for offline user data analysis.

SNS Ion Source↗

Recent Performance and Ignition Tests of the pulsed SNS H- Source for 1-MW Neutron Production

After acquiring several reliable spare targets, SNS ramped the beam power from 850 kW to 1.4 MW, which required an increase in H- beam pulse length from 0.88 to 1.0 ms at 60 Hz. This increase initially produced slow 2-MHz power ramp-ups and, after several weeks of uninterrupted operation, it produced plasma outages every time the pulse length was raised above ~0.95 ms. Similar outages were previously observed towards the end of long service cycles, which were believed to indicate that the breakdown voltage of the high purity hydrogen started to exceed the induced electric fields. In 2011 the RF was reconfigured to start with 10 cycles of 1.96 MHz, which yielded the shortest H- beam rise times and apparently eliminated those plasma outages. The new, pulse-length dependent outages were eliminated by increasing the initial frequency to 1.985 MHz. However, careful frequency studies are unable to justify this frequency. In addition, the paper discusses the issues and solutions for the electron-dump voltage, which starts to sag and become unstable after several weeks of high current operation.

43 PARTICLE ACCELERATORS↗

Recent Performance of and Plasma Outage Studies with the SNS H- Source

SNS ramps to higher power levels that can be sustained with high availability. The goal is 1.4 MW despite a compromised RFQ, which requires higher RF power than design levels to approach the nominal beam transmission. Unfortunately at higher power the RFQ often loses its thermal stability, a problem apparently enhanced by beam losses and high influxes of hydrogen. Delivering as much H- beam as possible with the least amount of hydrogen led to plasma outages. The root cause is the dense 1-ms long ~55-kW 2-MHz plasma pulses reflecting ~90% of the continuous ~300W, 13-MHz power, which was mitigated with a 4-ms filter for the reflected power signal and an outage resistant, slightly-detuned 13-MHz match. Lowering the H2 also increased the H- beam current to ~55 mA, and increased the transmission by ~7%.

H- ion source↗

Herschel observations of extra-ordinary sources: H{sub 2}S as a probe of dense gas and possibly hidden luminosity toward the Orion KL hot core

We present Herschel/HIFI observations of the light hydride H{sub 2}S obtained from the full spectral scan of the Orion Kleinmann-Low nebula (Orion KL) taken as part of the Herschel Observations of EXtra-Ordinary Sources GT (guaranteed time) key program. In total, we observe 52, 24, and 8 unblended or slightly blended features from H{sub 2} {sup 32}S, H{sub 2} {sup 34}S, and H{sub 2} {sup 33}S, respectively. We only analyze emission from the so-called hot core, but emission from the plateau, extended ridge, and/or compact ridge are also detected. Rotation diagrams for ortho and para H{sub 2}S follow straight lines given the uncertainties and yield T {sub rot} = 141 ± 12 K. This indicates H{sub 2}S is in local thermodynamic equilibrium and is well characterized by a single kinetic temperature or an intense far-IR radiation field is redistributing the population to produce the observed trend. We argue the latter scenario is more probable and find that the most highly excited states (E {sub up} ≳ 1000 K) are likely populated primarily by radiation pumping. We derive a column density, N {sub tot}(H{sub 2} {sup 32}S) = 9.5 ± 1.9 × 10{sup 17} cm{sup –2}, gas kinetic temperature, T {sub kin} = 120±{sub 10}{sup 13} K, and constrain the H{sub 2} volume density, n{sub H{sub 2}} ≳ 9 × 10 {sup 7} cm{sup –3}, for the H{sub 2}S emitting gas. These results point to an H{sub 2}S origin in markedly dense, heavily embedded gas, possibly in close proximity to a hidden self-luminous source (or sources), which are conceivably responsible for Orion KL's high luminosity. We also derive an H{sub 2}S ortho/para ratio of 1.7 ± 0.8 and set an upper limit for HDS/H{sub 2}S of <4.9 × 10 {sup –3}.

79 ASTRONOMY AND ASTROPHYSICS↗