Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Graphite specimens”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Determination of the orientation symmetry axis of graphite specimens

A technique is described for determining the true orientation symmetry axis of graphite specimens from conventional X-ray diffraction data. The technique, although developed for graphite, is applicable to any material exhibiting crystalline orientation which is symmetric about some axis. The requisite equations are derived for applying the procedure to both Bacon transmission data and rotating specimen reflection data. Results are presented which show that the symmetry axis of eleven molded graphites tested differed significantly from their nominal pressing directions.

Schryer, D. R.↗

Large-Scale Weibull Analysis of H-451 Nuclear- Grade Graphite Specimen Rupture Data

A Weibull analysis was performed of the strength distribution and size effects for 2000 specimens of H-451 nuclear-grade graphite. The data, generated elsewhere, measured the tensile and four-point-flexure room-temperature rupture strength of specimens excised from a single extruded graphite log. Strength variation was compared with specimen location, size, and orientation relative to the parent body. In our study, data were progressively and extensively pooled into larger data sets to discriminate overall trends from local variations and to investigate the strength distribution. The CARES/Life and WeibPar codes were used to investigate issues regarding the size effect, Weibull parameter consistency, and nonlinear stress-strain response. Overall, the Weibull distribution described the behavior of the pooled data very well. However, the issue regarding the smaller-than-expected size effect remained. This exercise illustrated that a conservative approach using a two-parameter Weibull distribution is best for designing graphite components with low probability of failure for the in-core structures in the proposed Generation IV (Gen IV) high-temperature gas-cooled nuclear reactors. This exercise also demonstrated the continuing need to better understand the mechanisms driving stochastic strength response. Extensive appendixes are provided with this report to show all aspects of the rupture data and analytical results.

Nemeth, Noel N.↗

Reliability Assessment of Graphite Specimens under Multiaxial Stresses

An investigation was conducted to predict the failure strength response of IG-100 nuclear grade graphite exposed to multiaxial stresses. As part of this effort, a review of failure criteria accounting for the stochastic strength response is provided. The experimental work was performed in the early 1990s at the Oak Ridge National Laboratory (ORNL) on hollow graphite tubes under the action of axial tensile loading and internal pressurization. As part of the investigation, finite-element analysis (FEA) was performed and compared with results of FEA from the original ORNL report. The new analysis generally compared well with the original analysis, although some discrepancies in the location of peak stresses was noted. The Ceramics Analysis and Reliability Evaluation of Structures Life prediction code (CARES/Life) was used with the FEA results to predict the quadrants I (tensile-tensile) and quadrant IV (compression-tension) strength response of the graphite tubes for the principle of independent action (PIA), the Weibull normal stress averaging (NSA), and the Batdorf multiaxial failure theories. The CARES/Life reliability analysis showed that all three failure theories gave similar results in quadrant I but that in quadrant IV, the PIA and Weibull normal stress-averaging theories were not conservative, whereas the Batdorf theory was able to correlate well with experimental results. The conclusion of the study was that the Batdorf theory should generally be used to predict the reliability response of graphite and brittle materials in multiaxial loading situations.

Sookdeo, Steven↗

Design and fabrication of graphite-epoxy bolted wing skin splice specimens

Graphite-epoxy bolted joint specimens were designed and fabricated. These specimens were to be representative of a side-of-body wing skin splice with a 20-year life expectancy in a commercial transport environment. Preliminary tests were performed to determine design values of bearing and net tension stresses. Based upon the information developed, a three-fastener-wide representative wing skin splice was designed for a load of 2627 KN/m (15,000 lbf/in.). One joint specimen was fabricated and tested at NASA. The wing skin splice failed at 106 percent of design ultimate load. This joint design achieved all static load objectives. Fabrication of six specimens, together with their loading fixtures, was completed, and the specimens were delivered to NASA-LRC.

Johnson, R. W.↗

Woven graphite epoxy composite test specimens with glass buffer strips

Woven unidirectional graphite cloth with bands of fiberglass replacing the graphite in discrete lengthwise locations was impregnated with epoxy resin and used to fabricate a series of composite tensile and shear specimens. The finished panels, with the fiberglass buffer strips, were tested. Details of the fabrication process are reported.

Bonnar, G. R.↗

Evaluation of long-duration exposure to the natural space environment on graphite-polyimide and graphite-epoxy mechanical properties (A0175)

The primary objective of this experiment is to accumulate the needed operational data associated with the exposure of graphite-polyimide and graphite-epoxy material to the environments of space. The experiment will be mounted in two 3-in.-deep peripheral trays. Graphite-polyimide specimens will occupy 1 1/3 trays and the graphite-epoxy specimens will occupy two-thirds of a tray. The experiment approach requires two matched sets of specimens with traceable records that are maintained for materials processing and specimen quality. After fabrication, one set of each test specimen will be sectioned and structurally tested to serve as a data baseline. After the flight, the other set of specimens will undergo extensive measurements of mechanical properties for comparison with the original data baseline. Structural testing of the graphite-polyimide specimens will provide strength and elastic data in tension, compression, and shear. Transverse tension microcracking and crack propagation will be evaluated by photomicroscopy. Structural testing of the graphite-epoxy specimens will include verification of laminate, core, adhesive, and fatigue properties as applied to the design and analysis of the payload bay door. Microcracking and crack propagation will also be analyzed by photomicroscopy.

Powell, J. H.↗

Effect of load introduction on graphite epoxy compression specimens

Compression testing of modern composite materials is affected by the manner in which the compressive load is introduced. Two such effects are investigated: (1) the constrained edge effect which prevents transverse expansion and is common to all compression testing in which the specimen is gripped in the fixture; and (2) nonuniform gripping which induces bending into the specimen. An analytical model capable of quantifying these foregoing effects was developed which is based upon the principle of minimum complementary energy. For pure compression, the stresses are approximated by Fourier series. For pure bending, the stresses are approximated by Legendre polynomials.

Reiss, R.↗

Experimental behavior of graphite-epoxy Y-stiffened specimens loaded in compression

An experimental investigation of the behavior of graphite-epoxy Y-stiffened specimens loaded in compression is presented. Experimental results are presented for element specimens with a single stiffener and for panel specimens with three stiffeners. Response and failure characteristics of the specimens are described. Effects of impact damage on structural response for both specimen configurations are also presented. Experimental results indicate that impact location may significantly affect the residual strength of the Y-stiffened specimens. The failure results indicate that the critical failure mode is buckling of the stiffener webs for Y-stiffened element specimens and buckling of the stiffener webs and other stiffener blades for the Y-stiffened panel specimens.

Sydow, P. Daniel↗

Experimental behavior of graphite-epoxy Y-stiffened specimens loaded in compression

An experimental investigation of the behavior of graphite-epoxy Y-stiffened specimens loaded in compression is presented. Experimental results are presented for element specimens with a single stiffener and for panel specimens with three stiffeners. Response and failure characteristics of the specimens are described. Effects of impact damage on structural response for both specimen configurations are also presented. Results indicate that impact location may significantly affect the residual strength of the Y-stiffened specimens. The failure results indicate that the critical failure mode is buckling of the stiffener webs for Y-stiffened element specimens and buckling of both stiffener web and stiffener blade for the Y-stiffened panel specimens.

Sydow, P. D.↗

Composite Of Bisfuran/Bismaleimide With Graphite Fibers

Composite-material specimens made of graphite fibers and matrix composed of experimental copolymer of bismaleimide and bisfuran. Found to have mechanical and thermal properties comparable or superior to those of similar composite-material specimens. Candidates for use as lightweight structural components to replace metal components in high-temperature aircraft applications. Bismaleimides used widely for other purposes because of low cost and ease in fabrication. Mechanical properties equal or exceed those of composite made with commercial formulation.

Meador, Mary Ann B.↗

Flight-service program for advanced composite rudders on transport aircraft

Flight service experience and in-service inspection results are reported for DC-10 graphite composite rudders during the third year of airline service. Test results and status are also reported for ground-based and airborne graphite-epoxy specimens with three different epoxy resin systems to obtain moisture absorption data. Twenty graphite composite rudders were produced, nine of which were installed on commercial aircraft during the past three years. The rudders collectively accumulated 75,863 flight hours. The high time rudder accumulated 12,740 flight hours in slightly over 36 months. The graphite composite rudders were inspected visually at approximately 1000 flight hour intervals and ultrasonically at approximately 3000 flight hour intervals in accordance with in-service inspection plans. All rudders were judged acceptable for continued service as a result of these inspections. Composite moisture absorption data on small specimens, both ground-based and carried aboard three flight-service aircraft, are given. The specimens include Thornel 300 fibers in Narmco 5208 and 5209 resin systems, and Type AS fibers in the Hercules 3501-6 resin system.

Source record↗

Application of a peak-valley detector for secant stiffness measurements

A technique for monitoring the change in secant stiffness of composite specimens during cyclic-fatigue loading computes the secant modulus every five seconds. A resettable peak-valley detector, which captures and holds the maximum and minimum values of an input analog signal, is used in conjunction with a multichannel data acquisition unit. This detector is also used in conjunction with an analog switch to halt the cycling of the specimen after a certain degradation of stiffness develops for the application of NDE techniques. Results for a T300/5208 graphite-epoxy specimen are presented in the form of a stiffness vs number of cycles curve.

Stiffler, R.↗

Improved Transverse Crack Detection in Composites

A modified ultrasonic C-scan technique was implemented for improving the detection of a certain type of damage in composite specimens. The type of damage being studied is transverse (through the thickness) cracking of unidirectional off-axis graphite-epoxy specimens. These cracks are difficult to detect using standard through-transmission C-scan techniques. The modification is based on mode conversion to produce transmitted shear waves from incident longitudinal waves. While mode conversion is used extensively with isotropic materials, its use with composites is more limited. This is largely because the computation of wave propagation parameters is significantly more complicated with highly anisotropic materials than with isotropic materials. The appropriate incident angles to produce the desired mode conversion were computed based on the mechanical properties of the composite. Once the angles were computed the technique was simple to implement and resulted in marked improvement in detection of the transverse cracks being studied.

Pereira, J. Michael↗

A fiber-optic technique for the measurement of contact angle in a clearance-fit pin-loaded hole

A fiber-optic technique for measuring contact angle during pin loading of a specimen is proposed. The experimental design and procedures for loading a 49.8-mm-diameter instrumented pin into an quasi-isotropic graphite-epoxy specimen are described. The optical fiber was located just above the surface of the pin outer diameter in order to obtain accurate pin-hole contact-angle measurements at increasing load levels. The movement of the optical fiber through the no-contact, contact, and no-contact regions is discussed; the photodiode output decreased monotonically as the fiber moved from the no-contact to the contact region and then decreased monotonically as the fiber moved from the contact region to the no-contact region. Variations in the contact angle measurements are examined as function of applied load level. The measurements are compared to contact angle values obtained using a finite element analysis and an electrical technique; it is determined that the data correlate well.

Prabhakaran, R.↗

An experimental investigation of Iosipescu specimen for composite materials

A detailed experimental evaluation of the Iosipescu specimen tested in the modified Wyoming fixture is presented. Moire interferometry is employed to determine the deformation of unidirectional and cross-ply graphite-epoxy specimens. The results of the moire experiments are compared to those from the traditional strain-gage method. It is shown that the strain-gage readings from one surface of a specimen together with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to twisting. A localized hybrid analysis is introduced to perform efficient reduction of moire data, producing whole-field strain distributions in the specimen test sections.

Ho, H.↗

Compression behavior of graphite-thermoplastic and graphite-epoxy panels with circular holes or impact damage

An experimental investigation of the compression behavior of laminated specimens made from graphite-epoxy tape, graphite-thermoplastic tape and graphite-thermoplastic fabric was conducted. Specimens with five different stacking sequences were loaded to failure in uniaxial compression. Some of the specimens had central circular holes with diameters up to 65 percent of the specimen width. Other specimens were subjected to low speed impact with impact energies up to 35 J prior to compressive loading. This investigation indicates that graphite-thermoplastic specimens with holes have up to 15 percent lower failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and hole size. However, graphite-thermoplastic specimens subjected to low speed impact have up to 15 percent higher failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and impact energy. Compression tests of graphite-thermoplastic specimens constructed of unidirectional tape and fabric indicate that the material form has little effect on failure strains in specimens with holes or low speed impact damage.

Jegley, Dawn C.↗

Comparison of hand laid-up tape and filament wound composite cylinders and panels with and without impact damage

Experimentally determined axial compressive failure loads, strains and failure modes of composite flat panels and cylinders are presented. A comparison of two types of filament wound flat graphite-epoxy panels indicates that the winding pattern can influence structural response. A comparison of hand laid-up tape and filament wound composite cylinders indicates that fabrication method may not significantly influence the failure mode or average failure strain of thick-walled (radius-to-thickness ratio less than 15) graphite-epoxy cylinders. The interaction of manufacturing-induced features (fiber cross-overs) and low-speed impact damage for graphite-epoxy specimens is also presented. Filament would flat panels with many fiber cross-overs exhibited lower failure strains than filament wound panels without fiber cross-overs for all impact speeds examined. Graphite-thermoplastic cylinders exhibited a significantly different failure mode from the graphite-epoxy cylinders.

Jegley, Dawn C.↗

Numerical analysis of the Iosipescu specimen for composite materials

A finite element analysis of the Iosipescu shear tests for unidirectional and cross-ply composites is presented. It is shown that an iterative analysis procedure must be used to model the fixture-specimen kinematics. The correction factors which are needed to compensate for the nonuniformity of stress distribution in calculating shear modulus are shown to be dependent on the material orthotropic ratio and the finite element loading models. Test section strain distributions representative of typical graphite-epoxy specimens are also presented.

Ho, H.↗