A phenomenological interpretation of the dynamic glass transition
Interpretation of glass transition in terms of viscoelastic state variables of temperature, frequency, and composition
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Interpretation of glass transition in terms of viscoelastic state variables of temperature, frequency, and composition
A dynamic fatigue study was performed on a Titanium Silicate Glass in order to assess its susceptibility to delayed failure. Fracture mechanics techniques were used to analyze the results for the purpose of making lifetime predictions for optical elements made from this material. The material has reasonably good resistance (N=23 to stress corrosion in ambient conditions).
Experimentally determined dynamic crack propagation histories in wedge-loaded, modified tapered, and rectangular double cantilever beam specimens were used to drive a dynamic finite element code in its generation phase. The resultant dynamic fracture toughness versus crack velocity relation, during the initial crack acceleration phase of these dynamic fracture specimens, was erratic but followed the standard Gamma-shaped curves of brittle polymers and metals during subsequent crack propagation at terminal velocity and crack deceleration phases. The distinct initiation phase of dynamic crack propagation, which was not observed in dynamic fracture of brittle polymer and metal specimens, is attributed to the lower stored energy in the glass specimen.
The dynamic and static fatigue behavior of a machinable glass ceramic was investigated to assess its susceptibility to stress corrosion-induced delayed failure. Fracture mechanics techniques were used to analyze the results so that lifetime predictions for components of this material could be made. The resistance to subcritical crack growth of this material was concluded to be only moderate and was found to be dependent on the size of its microstructure.
Static and dynamic fatigue behavior of glass filament-wound plastic pressure vessels at ambient and cryogenic temperatures
A dynamic fatigue study was performed on a Li2O-Al2O3-SiO2 glass-ceramic in order to assess its susceptibility to delayed failure. Fracture mechanics techniques were used to analyze the results for the purpose of making lifetime predictions for optical elements made from this material. The material has reasonably good resistance (N = 20) to stress corrosion in ambient conditions. Analysis also indicated the elements should survive applied stresses incurred during grinding and polishing operations.
To assess the stress corrosion susceptibility of a machinable glass-ceramic, its dynamic fatigue behavior was investigated by measuring its strength as a function of stress rate. Fracture mechanics techniques were used to analyse the results for the purpose of making lifetime predictions for components of this material. This material was concluded to have only moderate resistance to stress in ambient conditions. The effects of specimen size on strength were assessed for the material used in this study: it was concluded that the Weibull edge-flaw scaling law adequately describes the observed strength-size relationship.
To assess the stress-corrosion susceptibility of a machinable glass-ceramic, its dynamic fatigue behavior was investigated by measuring its strength as a function of stress rate. Fracture mechanics techniques were used to analyze the results for the purpose of making lifetime predictions for components of this material. This material was concluded to have only moderate resistance (N = 30) to stress corrosion in ambient conditions. The effects of specimen size on strength were assessed for the material used in this study; it was concluded that the Weibull edge-flaw scaling law adequately describes the observed strength-size relation.
Ultra Low Expansion (ULE) glass is used in a number of applications which require a low thermal expansion coefficient. One such application is telescope mirror elements. An allowable stress can be calculated for this material based upon modulus of rupture data; however, this does not take into account the problem of delayed failure. Delayed failure, due to stress corrosion can significantly shorten the lifetime of a glass article. Knowledge of the factors governing the rate of subcritical flaw growth in a given environment enables the development of relations between lifetime, applied stress and failure probability for the material under study. Dynamic fatigue is one method of obtaining the necessary information to develop these relationships. In this study, the dynamic fatigue method was used to construct time-to-failure diagrams for both 230/270 ground and optically polished samples. The grinding and polishing process reduces the surface flaw size and subsurface damage, and relieves residual stress by removing materials with successively smaller grinding media. This resulted in an increase in the strength of the optic during the grinding and polishing sequence. There was also an increase in the lifetime due to grinding and polishing. It was found that using the fatigue parameters determined from the 230/270 grit surface are not significantly different from the optically polished values. Although the lower bound of the polished samples is more conservative, neither time-to-failure curves lie beyond the upper or lower bound of the confidence limits. Therefore, designers preferring conservative limits could use samples without residual stress present (polished samples) to determine the fatigue parameters and inert Weibull parameters from samples with the service condition surface, to determine time-to-failure of the optical element.
Investigation of the pressure load carrying capacity and fatigue strength of filament-wound glass-reinforced plastic pressure vessels subjected to static and cyclic loading at ambient and cryogenic (liquid nitrogen) temperature environments. The results indicate that the static fatigue problem is not critical at cryogenic temperatures. Under static loading at liquid nitrogen temperature, a reinforced plastic cylinder sustained pressurization for 88 days without failure at about 90% of the single cycle burst strength. At ambient temperature, the static life at 90% of the burst strength was about 7 min. Under cyclic loading in liquid nitrogen, no failure resulted after 1509 cycles at 55% of the single cycle burst strength. Under the same cyclic loading at ambient temperature, the test results would predict failure in the reinforced plastic. The results of similar tests upon adhesively bonded polyimide aluminum-foil lined cylinders are also reviewed.-
Circular specimens of low iron soda lime silicate glass were blasted with grit after having a circular notch etched into their centers. After separation into two groups, one group was exposed to gamma radiation. The fracture strengths of all samples were then tested by the biaxial technique, i.e., specimens were balanced on three balls and loaded in the center by a piston. The irradiated samples had received a 140,000 Gy dose from a Co-60 source. An enhanced interaction between the ambient moisture and the grit-blasted central notch was observed in the irradiated samples, which displayed accelerated corrosion.
Solar Dynamic Space Power Systems are candidate electrical power generating systems for future NASA missions. One of the key components in a solar dynamic power system is the concentrator which collects the sun's energy and focuses it into a receiver. In 1985, the NASA Lewis Research Center initiated the Advanced Solar Dynamic Concentrator Program with funding from NASA's Office of Aeronautics and Space Technology (OAST). The objectives of the Advanced Concentrator Program is to develop the technology that will lead to lightweight, highly reflective, accurate, scaleable, and long lived (7 to 10 years) space solar dynamic concentrators. The Advanced Concentrator Program encompasses new and innovative concepts, fabrication techniques, materials selection, and simulated space environmental testing. The Advanced Microsheet Glass Concentrator Program, a reflector concept, that is currently being investigated both in-house and under contract is discussed.
Dynamic mechanical studies of thermosetting PMR 15 polyimide/Celion 6000 composites were used to characterize cure behavior. Variation in composite shear modulus with cure time for laminates partially cured under 3.45 MPa pressure was compared with that of laminates fully cured under pressure to select a partially cured system whose behavior corresponded with that of the pressure-cured composites. An empirical kinetic model was developed that relates relative composite shear moduli to cure time and temperature. This model, coupled with standard statistical techniques, was used in the determination of an overall activation energy, E = 145 kj/mole (35 kcal/mole) and order of reaction, n, for the cure reaction(s). The empirical relationship defining dynamic modulus as a function of time and temperature remained linear well into the glassy region. Changes in dynamic glass-transition temperature and in the breadth of the transition peaks with cure time are discussed. Shear modulus and damping were found to be more sensitive measures of relative extent of cure than Fourier transform infrared spectroscopy.
Advanced solar dynamic concentrator concepts being considered by the NASA Lewis Research Center for space power systems include one utilizing microsheet glass coated with silver. For this material, a 5000-angstrom layer of silver is deposited on the back side of a contoured piece of microsheet glass, 0.2-mm thick. The silvered side is then bonded to a contoured aluminum, magnesium, or graphite epoxy face sheet with a space-qualified, pressure-sensitive thin-film adhesive. Experience gained from the development of this technology suggests that this material may reduce the cost and improve the performance of solar dynamic concentrators. This microsheet glass technology provides an effective barrier to atomic oxygen attack and provides the opportunity to utilize silver-reflective coatings in low-Earth-orbit solar dynamic applications.
The inherent brittleness of glass invariably leads to a large variability in strength data and a time dependence in strength. Leading rate plays a large role in strength values. Glass is found to be weaker when supporting loads over long periods of time as compared to glass which undergoes rapid leading. These properties complicate the structural design allowables for the utilization of glass components in an application such as Advanced X-ray Astrophysics Facility (AXAF). The test methodology to obtain parameters which can be used to predict the reliability and life time of Zerodur glass-ceramic which is to be used for the mirrors in the AXAF is described.
A dynamic fatigue study was performed on a Titanium Silicate glass to assess its susceptibility to delayed failure and to compare the results with those of a previous study. Fracture mechanics techniques were used to analyze the results for the purpose of making lifetime predictions. The material strength and lifetime was seen to increase due to the removal of residual stress through grinding and polishing. Influence on time-to-failure is addressed for the case with and without residual stress present. Titanium silicate glass otherwise known as ultra-low expansion (ULE)* glass is a candidate for use in applications requiring low thermal expansion characteristics such as telescope mirrors. The Hubble Space Telescope s primary mirror was manufactured from ULE glass. ULE contains 7.5% titanium dioxide which in combination with silica results in a homogenous glass with a linear expansion coefficient near zero. delayed failure . This previous study was based on a 230/270 grit surface. The grinding and polishing process reduces the surface flaw size and subsurface damage, and relieves residual stress by removing the material with successively smaller grinding media. This results in an increase in strength of the optic during the grinding and polishing sequence. Thus, a second study was undertaken using samples with a surface finish typically achieved for mirror elements, to observe the effects of surface finishing on the time-to-failure predictions. An allowable stress can be calculated for this material based upon modulus of rupture data; however, this does not take into account the problem of delayed failure, most likely due to stress corrosion, which can significantly shorten lifetime. Fortunately, a theory based on fracture mechanics has been developed enabling lifetime predictions to be made for brittle materials susceptible to delayed failure. Knowledge of the factors governing the rate of subcritical flaw growth in a given environment enables the development of relations between lifetime, applied stress and failure probability for the material under study. Dynamic fatigue is one method of obtaining the necessary information to develop these relationships. In this study, the dynamic fatigue method was used to construct a time-to-failure diagram for polished ULE glass.
The viscoelastic properties of an addition-cured polyimide, PMR-15, were evaluated through dynamic mechanical and stress relaxation testing. Below the glass transition temperature, the dynamic mechanical properties of the composites are strongly affected by the absorbed moisture in the resin. At temperature 20 C and more above the glass transition temperature, the storage modulus increases continuously with time, indicating that additional crosslinking is occurring in the resin. For resin moisture contents less than 2 percent, stress relaxation curves measured at different temperatures can be superimposed using horizontal shifts along the log(time) axis with only small shifts along the vertical axis.
It is shown that the Zhurkov method for testing the strength of solids can be applied to dynamic tension and to cyclic loading and provides a viable approach to accelerated testing of composites. Data from the literature are used to demonstrate a straightforward application of the method to dynamic tension of glass fiber and cyclic loading for glass/polymer, metal matrix, and graphite/epoxy composites. Zhurkov's equation can be used at relatively high loads to obtain failure times at any temperature of interest. By taking a few data points at one or two other temperatures the spectrum of failure times can be expanded to temperatures not easily accessible.