Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geologic Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design and simulation of a muon detector to characterize geological overburden

This study presents the design, construction, and simulation of a mobile muon detector tailored for geological overburden characterization. The detector employs plastic scintillator paddles with silicon photomultipliers (SiPMs) and a QuarkNet data acquisition system, offering a portable solution suitable for remote field deployment. The simulator’s modular aluminum frame allows for adjustable geometry and directional sensitivity, while its battery system supports over a week of autonomous operation. Preliminary experimental tests confirmed that its muon flux measurements were consistent with theoretical expectations. A comprehensive simulation framework using Geant4 and CORSIKA was developed to model detector response and overburden effects. Analytical and Monte Carlo methods were used to assess quadrant resolution and infer muon directionality. This work lays the foundation for future overburden mapping and supports the development of reconstruction algorithms for geological applications.

72 - PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geologic Characterization of the South Georgia Rift Basin for Source Proximal CO2 Storage

The project Geologic Characterization of the South Georgia Rift Basin for Source Proximal CO2 Storage is one of 9 site characterization projects that were implemented as part of ARRA (American Recovery and Reinvestment Act). Data from this project was used to improve resolution of data in NATCARB in the area of study. Data related to this study has already been incorporated in NATCARB Atlas. The South Carolina Research Foundation and partners evaluated the feasibility of CCS in the Jurassic/ Triassic (J / TR) saline formations of the buried Mesozoic South Georgia Rift (SGR) Basin that extends from South Carolina into Georgia. The J / TR sequence, based on preliminary assessment of limited geologic and geophysical data, appears to have both the appropriate areal extent and multiple horizons to permanently and safely store CO2 The presence of several igneous rock layers within the sequence may potentially provide adequate seals to prevent upward CO2 migration into the Coastal Plain aquifer systems. Approximately 81 kilometers of 2-D seismic reflection data were collected by Bay Geophysical, Inc. to explore a portion of the SGR located in southern Georgia. The 81 kilometers were divided into two lines approximately 40.5 kilometers each, with Line 1 intersecting Georgia well GGS 3457. Line 2 intersects Line 1 at the southern portion of Line 1 to maximize the extent of coverage away from GGS-3457 (a deep well drilled in the 1980s for oil and gas exploration). This well had a set of usable logs, including gamma and neutron logs that provided promising results related to CO2 storage. Results showed sandstone with porosity values greater than 10 percent and a thickness of 120 meters. The design of the seismic shot was to extrapolate information away from the well and to better define the extent of the SGR and the necessary reservoir and caprock for a successful CO2 injection. A numerical simulation model of CO2 Injection and migration was developed based on the geology log for the GGS-3457 well. The simulation model was used to investigate the feasibility of injecting 30 million metric tons of CO2 into SGR J / TA sediments and integrity of the diabase layers as seals to prevent CO2 migration.

2-D seismic↗

Geologic Characterization for CO 2 Storage with Enhanced Oil Recovery in Northern Michigan

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. This report compiles the results of geologic characterization of late-stage reefs, active EOR reefs, and new EOR reefs in the Northern Niagaran Pinnacle Reef Trend (NNPRT) in Michigan to demonstrate developed methodologies, geologic variability, and reservoir potential for CO 2 storage. Conducting CO 2 injection and monitoring in these settings provide significant insights for addressing the project objectives: assessment of injectivity in complex carbonate reef deposits; assessing CO 2 trapping mechanisms in a closed reservoir system; assessing any final oil recovery from transitional or residual oil zones in a field where CO 2 flooding is nearing completion; evaluating the transition from EOR to storage of CO 2 ; assessing regional commercialization; assessing new technologies for tracking CO 2 , brine, and oil movements underground; and monitoring options in a closed reservoir with oil, residual oil, and water zones.

01 COAL, LIGNITE, AND PEAT↗

Geological characterization and ROZ potential of the Tar Springs Sandstone

This report focuses on regional and field scale geological characterization of the Tar Springs in Illinois using well records, including drilling and completion reports, well logs, and core data (core descriptions/core analyses) to analyze and interpret geological variations. In addition, oil saturation indicators (oil shows, oil saturation from core analysis, and drill stem test data) were analyzed to determine the ROZ potential of the Tar Springs Sandstone

02 PETROLEUM↗

Evaluation of Caprock Integrity of the Upper Ordovician Units within the CarbonSAFE Prefeasibility Study Region, Subtask 4.3 – Geological Characterization

In this report, the Indiana Geological and Water Survey (IGWS) evaluates the seal capacity of the Maquoketa Shale Group, a thick and heterogeneous sequence of carbonates, silts, and clay-rich rock units of Upper Ordovician age. This unit has been identified as a regional caprock that can effectively isolate the CO 2 stored in underlying reservoirs for secure sequestration. To accomplish this objective, the Maquoketa Group was assessed using two approaches: (1) development of a lithofacies/qualitative permeability model based on the combined wireline responses, and (2) analysis to characterize the pore size distribution and capillary entry pressures of the various lithologies in the unit using the mercury injection capillary pressure method.

01 COAL, LIGNITE, AND PEAT↗

sRecovery Act: Geologic Characterization of the South Georgia Rift Basin for Source Proximal CO 2 Storage

This study focuses on evaluating the feasibility and suitability of using the Jurassic/Triassic (J/TR) sediments of the South Georgia Rift basin (SGR) for CO 2 storage in southern South Carolina and southern Georgia The SGR basin in South Carolina (SC), prior to this project, was one of the least understood rift basin along the east coast of the U.S. In the SC part of the basin there was only one well (Norris Lightsey #1) the penetrated into J/TR. Because of the scarcity of data, a scaled approach used to evaluate the feasibility of storing CO 2 in the SGR basin. In the SGR basin, 240 km (~149 mi) of 2-D seismic and 2.6 km2 3-D (1 mi2) seismic data was collected, process, and interpreted in SC. In southern Georgia 81.3 km (~50.5 mi) consisting of two 2-D seismic lines were acquired, process, and interpreted. Seismic analysis revealed that the SGR basin in SC has had a very complex structural history resulting the J/TR section being highly faulted. The seismic data is southern Georgia suggest SGR basin has not gone through a complex structural history as the study area in SC. The project drilled one characterization borehole (Rizer # 1) in SC. The Rizer #1 was drilled but due to geologic problems, the project team was only able to drill to 1890 meters (6200 feet) instead of the proposed final depth 2744 meters (9002 feet). The drilling goals outlined in the original scope of work were not met. The project was only able to obtain 18 meters (59 feet) of conventional core and 106 rotary sidewall cores. All the conventional core and sidewall cores were in sandstone. We were unable to core any potential igneous caprock. Petrographic analysis of the conventional core and sidewall cores determined that the average porosity of the sedimentary material was 3.4% and the average permeability was 0.065 millidarcy. Compaction and diagenetic studies of the samples determined there would not be any porosity or permeability at depth in SC. In Georgia there appears to be porosity in the J/TR section based on neutron log porosity values. The only zones in Rizer #1 that appear to be porous were fractured diabase units where saline formation water was flowing into the borehole. Two geocellular models were created for the SC and GA study area. Flow simulation modeling was performed on the SC data set. The injection simulation used the newly acquired basin data as well as the Petrel 3-D geologic model that included geologic structure. Due to the new basin findings as a result of the newly acquired data, during phase two of the modeling the diabase unit was used as reservoir and the sandstone units were used as caprock. Conclusion are: 1) the SGR basin is composed of numerous sub-basins, 2) this study only looked at portions of two sub-basins, 3) in SC, 30 million tonnes of CO 2 can be injected into the diabase units if the fracture network is continuous through the units, 4) due to the severity of the faulting there is no way of assuring the injected CO 2 will not migrate upward into the overlying Coastal Plain aquifers, 5) in Georgia there appears to porous zones in the J/TR sandstones, 6) as in SC there is faulting in the sub-basin and the seismic suggest the faulting extends upward into the Coastal Plain making that area not suitable for CO 2 sequestration, 7) the complex faulting observed at both study areas appear to be associated with transfer fault zones (Heffner 2013), if sub-basins in the Georgia portion of the SGR basin can be located that are far away from the transfer fault zones there is a strong possibility of sequestering CO 2 in these areas, and 9) the SGR basin covers area in three states and this project only studied two small areas so there is enormous potential for CO 2 sequestration in other portions the basin and further research needs to be done to find these areas.

58 GEOSCIENCES↗

Three-Dimensional Geologic Characterization of Geothermal Systems: Astor Pass, Nevada, USA

Geothermal systems in the Great Basin, USA, are controlled by a variety of fault intersection and fault interaction areas. Understanding the specific geometry of the structures most conducive to geothermal circulation is crucial in order to both mitigate the costs of geothermal exploration (especially drilling) and to identify blind geothermal systems (no surface expression). Astor Pass, Nevada, one such blind geothermal system, lies near the boundary between two distinct structural domains, the Walker Lane and the Basin and Range, and exhibits characteristics of each setting. Both northwest-striking, left-stepping dextral faults of the Walker Lane and kinematically linked northerly striking normal faults associated with the Basin and Range are present at Astor Pass. Previous studies identified a blind geothermal system controlled by the intersection of northwest-striking dextral and north-northwest-striking normal faults. Wells drilled into the southwestern quadrant of the fault intersection yielded 94°C fluids, with geothermometers suggesting significantly higher maximum temperatures. Additional data, including reprocessed 2D seismic data and petrologic analysis of well cuttings, were integrated with existing and reinterpreted geologic maps and cross-sections to aid construction of a 3D geologic model. This comprehensive 3D integration of multiple data sets allows characterization of the structural setting of the Astor Pass blind geothermal system at a level of detail beyond what independent data interpretation can provide. Our analysis indicates that the blind geothermal system is controlled by two north- to northwest-plunging fault intersections.

15 GEOTHERMAL ENERGY↗

Three-Dimensional Geologic Characterization of a Great Basin Geothermal System: Astor Pass, Nevada

The Great Basin, western USA, exhibits anomalously high heat flow (~75±5 mWm-2) and active faulting and extension, resulting in ~430 known geothermal systems. Recent studies have shown that steeply dipping normal faults in transtensional pull-aparts are a common structural control of these Great Basin geothermal systems. The Astor Pass blind (no surface expression) geothermal system, Nevada, lies along the boundary between the Basin and Range to the east and the Walker Lane to the west. Across this boundary, strain is transferred from dextral shear in the Walker Lane to west-northwest directed extension in the Basin and Range, resulting in a transtensional setting consisting of both northwest-striking, left-stepping dextral faults and northerly striking normal faults. Previous studies indicate that Astor Pass was controlled by the intersection of a northwest-striking dextral normal fault and north-northwest striking normal-dextral fault bounding the western side of the Terraced Hills. Drilling (to ~1200 m) has revealed fluid temperatures of ~94°C, confirming a blind geothermal system. Expanding upon previous work and employing interpretation of 2D seismic reflection data, additional detailed geologic mapping, and well cuttings analysis, a 3-dimensional geologic model of the Astor Pass geothermal system was constructed. The 3D model indicates a complex interaction/intersection area of three discrete fault zones: a northwest-striking dextral-normal fault, a north-northwest-striking normal-dextral fault, and a north-striking west-dipping normal fault. These two discrete, critically-stressed intersection areas plunge moderately to steeply to the NW-NNW and probably act as conduits for upwelling geothermal fluids.

15 GEOTHERMAL ENERGY↗

Petrographic and Advanced Geologic Characterization Report on One Earth Energy #1 (API# 1211325373)

The One Earth Energy #1 (OEE1, API 1211325373) well was drilled to a depth of 7,099 feet from the Pennsylvanian bedrock to the Precambrian granite. In total, 99 thin sections were taken from Rotary Sidewall Core (RSWC) from 2,275 feet to 6,903 feet; 59 thin sections were taken from Whole Core (WC) from 4,311.5 to 6,519.2 feet for this report. This report details specifically thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis annotated thin section photomicrographs, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS), and statistics of grain size analysis on Mount Simon thin sections from OEE1. Characterized units include the St. Peter Sandstone, Eminence Formation, Potosi Dolomite, Franconia Formation, Davis Member, Ironton Sandstone, Galesville Sandstone, Eau Claire Formation, Elmhurst Sandstone, Mt. Simon Sandstone, and Argenta Formation.

09 BIOMASS FUELS↗

Petrographic and Advanced Geologic Characterization Report on Lively Grove #1 (API# 1218924947)

Lively Grove #1 (LG1 API number 1218924947) well was drilled to a depth of 5,758 feet, from the Glen Dean Limestone to the top of the Precambrian unit. In total, 49 thin sections were taken from Rotary Sidewall Core (RSWC), and one thin section was taken from Whole Core (2,918 feet, New Albany Shale) from 1,700 to 5,872 feet for this report. This report details specifically thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis annotated thin section photomicrographs, scanning electron microscopy (SEM) with Energy Dispersive x-ray Spectroscopy (EDS), X-ray Diffraction (XRD), statistics of grain size analysis on St. Peter Sandstone thin sections, and Argon-Argon (Ar-Ar) dating on Precambrian samples from LG1. Characterized units include the Salem Limestone, New Albany Shale, Trenton Group, Joachim Dolomite, St. Peter Sandstone, Everton Formation, Eminence Formation, Davis Member, Eau Claire Formation, and Precambrian Basement.

01 COAL, LIGNITE, AND PEAT↗