Identification of late-stage tau accumulation using plasma phospho-tau217
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Endometriosis, defined as the ectopic growth of endometrial tissue outside of the uterine cavity, is an inflammatory and hormone-dependent disease that causes excruciating pelvic pain, infertility, and significantly decreases quality of life in affected patients. The JUN N-terminal kinases (JNKs) are a leading class of nonhormonal therapeutic targets that have been validated in preclinical models of endometriosis and in a Phase 1/2 clinical trial. Despite their therapeutic potential, JNK inhibitors with increased potency and specificity are needed to address the inflammatory pathology of endometriosis and to prevent disease progression. Leveraging a DNA-encoded chemical library collection of ~4 billion compounds, we identified lead inhibitor CDD-2428 and optimized derivatives, CDD-2728 and CDD-3013, with excellent binding affinity to JNK1-3 (K d = 0.12 to 3.7 nM), enhanced selectivity, metabolic stability, and cellular permeability. Crystallographic and biochemical studies confirmed that CDD-3013 exhibited superior kinase selectivity with improved efficacy compared to existing JNK inhibitors. In primary endometriosis cell models, CDD-2728 and CDD-3013 suppressed JNK-dependent inflammatory signaling, dampening pathways linked to pain, invasion, angiogenesis, and macrophage recruitment. In an endometriosis mouse model, both CDD-2728 and CDD-3013 reduced endometriotic lesion size, macrophage infiltration, and cellular proliferation, showing in vivo efficacy. When tested in a lipopolysaccharide-induced hyperalgesia model, CDD-2728 and CDD-3013 decreased markers of induced pain, as measured by changes in a dynamic weight bearing test and Grimace scores. These findings nominate CDD-2728 and CDD-3013 as potent, nonhormonal therapeutic candidates for endometriosis with broad anti-inflammatory and analgesic activity, addressing a critical unmet clinical need.
Barometric pressure, gas composition, toxicity, and thermal exchange of spacecraft cabin atmospheres are discussed. Effects of gravitation, acceleration, weightlessness, noise, and vibration on human behavior and performance during space flight are also described.
Gemini spacecraft and launch vehicle development and performance, flight operations, mission results, and physical science and biomedical experiments - Gemini midprogram conference
Abstract Francisella tularensis poses considerable public health risk due to its high infectivity and potential for bioterrorism. Francisella‐like lipoprotein (Flpp3), a key virulence factor unique to Francisella, plays critical roles in infection and immune evasion, making it a promising target for therapeutic development. However, the lack of well‐defined binding pockets and structural information on native interactions has hindered structure‐guided ligand discovery against Flpp3. Here, we used a combination of physics‐based and deep‐learning methods to design high‐affinity miniprotein binders targeting two distinct sites on Flpp3. We identified four binders for site I with binding affinities ranging between 24–110 nM. For the second site, an initial binder showed a dissociation constant ( K D ) of 81 nM, and subsequent site saturation mutagenesis yielded variants with sub‐nanomolar affinities. Circular dichroism confirmed the topology of designed miniproteins. The X‐ray crystal structure of Flpp3 in complex with a site I binder is nearly identical to the design model (Cα root‐mean‐square deviation (RMSD): 0.9 Å). These designed miniproteins provide research tools to explore the roles of Flpp3 in tularemia and should enable the development of new therapeutic candidates.
ABSTRACT Tau pathology spread into neocortex indicates a transition from healthy aging to Alzheimer's disease (AD). Connectivity between tau epicenters and later accumulating regions of cortex has been proposed as a mechanism of tau spread, but how this relationship changes with greater AD pathology burden or genotype is not understood. We investigated tau accumulation in two key regions, precuneus and inferior temporal cortex, using resting state functional connectivity (rsFC) and longitudinal PET imaging from a multicohort sample of cognitively unimpaired older adults. We examined how baseline tau PET, Aβ PET, and ApoE4 genotype status interact with rsFC between hippocampus and these downstream regions to predict rate of tau accumulation in neocortex. We found that the 3‐way interaction between connectivity, baseline tau, and baseline Aβ or ApoE4 status was associated with neocortical tau accumulation in precuneus and inferior temporal cortex. In addition, baseline tau, Aβ, and ApoE4 status also moderated the association between connectivity and rate of memory decline. Together, these results suggest that the extent and distribution of future tau accumulation may be predicted by the interaction of baseline connectivity, AD pathology, and genetic risk.
Heat exposure has been linked to psychosocial stress, an established antecedent of perinatal depression; however, evidence on heat-related stress during pregnancy in sub-Saharan Africa remains limited. We analyzed psychosocial stress scores and covariate data from the Ghana Randomized Air Pollution and Health Study, linking daily maximum and minimum shaded wet bulb globe temperature (WBGT) metrics to participants’ stress scores derived from the Crisis in Family Systems-Revised Life Events Questionnaire. We evaluated associations using ordinal logistic regression of pregnancy-average and trimester-average exposures and distributed lag non-linear models (DLNMs) to assess time-varying associations across gestation. Higher average maximum WBGT exposure across pregnancy was associated with increased odds of higher psychosocial stress; each 1 °C increase in maximum WBGT was associated with 64% higher odds of belonging to a higher stress category (OR = 1.64; 95% CI = 1.17–2.31; p = 0.0040). In trimester-average models, higher first-trimester maximum WBGT was also associated with higher stress (OR = 1.44; 95% CI = 1.15–1.81; p = 0.0014). DLNMs suggested that relatively cooler daily maximum WBGT values (25th percentile) were associated with decreased odds of stress in early pregnancy, whereas extreme daily maximum WBGT values (99th percentile) showed a pattern consistent with increased odds of stress in mid-to-late gestation. These findings highlight gestational windows in which heat exposure may influence stress, emphasizing the need for further research into underlying mechanisms and effective interventions to protect maternal mental health in heat-vulnerable settings.
Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.
Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.
The high specific impulse (Isp) of Nuclear Electric Propulsion (NEP) technology offers the potential for advanced space mission capabilities. However, the five critical technology elements of NEP vehicles have yet to prove technical maturity levels for consideration into mission design. In response to the critical reviews by the NASA Engineering and Safety Center (NESC) and the National Academies of Sciences, Engineering, and Medicine (NASEM), NASA’s Space Nuclear Propulsion (SNP) project created an NEP Technology Maturation Plan (TMP) for focused development of NEP technology. The TMP called for a coordinated set of technology development efforts to meet this objective. The Modular Assembled Radiators for NEP VehicLes (MARVL) Early Career Initiative (ECI) project was initiated to develop a portion of the fifth Critical Technology Element (CTE) of the NEP vehicle: the Primary Heat Rejection Subsystem (PHRS). A target application of a 2039 human-rated Mars mission was outlined in the TMP. For the outlined mission, a NEP vehicle will experience several thermal environments which will impact the design and operation of the PHRS. To maintain radiator temperatures within the required effective temperature range, the effect of natural, induced, and NEP internally generated heat loads on the radiator panel must be well understood. Furthermore, this analysis is critical for analyzing the influence of various orientations and positions of the NEP vehicle relative to nearby celestial bodies throughout the mission. This study conducted a complete enveloping analysis of the thermal environments influencing the NEP vehicle throughout the mission. Thermal analysis was conducted for the radiator panels based on the defined mission environments. This thermal analysis concludes with the selection of ideal radiator orientations for the NEP vehicle, and the identification of worst case hot and cold environmental sink temperatures throughout the mission. For the target application, the environmental sink temperature while the reactor is powered OFF or powered ON ranges from 30 K to 353 K and 2.7 K to 243 K respectively. When considering interplanetary space, the minimum environmental sink temperature when the reactor is powered OFF and the radiators are oriented “edge to Sun” is 2.7 K. The environmental thermal models generated in this study will be used for future studies with the full vehicle system model. The environmental sink temperature curves generated will be used for future radiator and component analysis to predict transient performance in the space environment. The environmental sink temperature and heat rejection capability curves will inform the trade between commissioning orbits that are in consideration. The model may also serve as a useful tool as reference for future crewed space missions, missions involving radiators or temperature sensitive equipment, or other missions requiring analysis of natural orbital thermal environments.
As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.
Disclosed are non-linear transmission lines using ferromagnetic materials to generate ferromagnetic resonance oscillations. In one aspect, a non-linear transmission line apparatus is disclosed. The apparatus includes an outer conductor having a first side and a second internally facing side, and an inner conductor positioned internal to the non-linear transmission line apparatus. The apparatus further includes a ferromagnetic material surrounding the inner conductor, wherein the ferromagnetic material comprises nanoparticles of an ε-polymorph of iron oxide expressed as ε-Fe2O3. The apparatus also includes a first dielectric material positioned between the outer conductor and the inner conductor, the dielectric material in contact with both the ferromagnetic material and with the second internally facing side of the outer conductor, wherein the outer conductor, the inner conductor, the dielectric material and the ferromagnetic material form the nonlinear transmission line.
Modern space propulsion and exploration system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. The Inductive Monitoring System (IMS) is a data-driven system health monitoring software tool that has been successfully applied to several aerospace applications. IMS uses a data mining technique called clustering to analyze archived system data and characterize normal interactions between parameters. This characterization, or model, of nominal operation is stored in a knowledge base that can be used for real-time system monitoring or for analysis of archived events. Ongoing and developing IMS space operations applications include International Space Station flight control, satellite vehicle system health management, launch vehicle ground operations, and fleet supportability. As a common thread of discussion this paper will employ the evolution of the IMS data-driven technique as related to several Integrated Systems Health Management (ISHM) elements. Thematically, the projects listed will be used as case studies. The maturation of IMS via projects where it has been deployed, or is currently being integrated to aid in fault detection will be described. The paper will also explain how IMS can be used to complement a suite of other ISHM tools, providing initial fault detection support for diagnosis and recovery.
Actinides are inherently unstable and undergo nuclear decay processes with a concurrent release of energy. Consequently, they are used for nuclear power generation, nuclear weapons, and nuclear medicine. However, the radioactive decay processes also pose significant technological problems for the safe treatment and storage of spent nuclear materials. Cost-effective extraction of the actinides is the key first step in the remediation of nuclear waste, but the appropriate chemical means have yet to be determined. Our present understanding of the chemistry of actinides is limited, with the role of the 5f electrons posing a set of particularly challenging questions. The work reported here is focused on the use of electronic spectroscopy to probe the bonding of small molecules in the gas phase that contains thorium or uranium. Analyses of these data, carried out within the framework of ligand field theory, reveal clear evidence that the 5f electrons are spectators that retain their atomic metal ion character.
The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the ISS is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace Ni-H2 batteries approaching the end of their useful life and concurrently funded a Li-Ion ORU (Orbital Replacement Unit) and cell life testing project. The first set of 6 Li-ion battery replacements was launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit cycling and the status of the Li-Ion cell and ORU life cycle testing.
International Space Station Lithium-Ion Battery Start-Up.The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. As the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. The first set of 6 Li-ion battery replacements were launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit start-up and the status of the Li-Ion cell and ORU life cycle testing.
When originally launched, the International Space Station (ISS) primary Electric Power System (EPS) used Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate for ten years at a 35 percent depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. For service beyond that period, upgraded Li-Ion Orbital Replacement Units (ORUs) were designed. These are the largest Li-Ion batteries ever utilized for a human rated spacecraft. With the oldest 12 Ni-H2 battery ORUs cycling since September 2006, the first set of six was replaced by Li-Ion batteries in December 2016; the second set of six is planned for replacement in September 2018. This paper will include an overview of the ISS Li-Ion battery system architecture, on-orbit status of the first 6 batteries, start up of the second 6 batteries, and the status of the Li-Ion cell and ORU life cycle testing.
When originally launched, the International Space Station (ISS) primary Electric Power System (EPS) used Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate for ten years at a 35% depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. For service beyond that period, upgraded Li-Ion Orbital Replacement Units (ORUs) were designed. These are the largest Li-Ion batteries ever utilized for a human rated spacecraft. The first set of six Ni-H2 batteries was replaced by Li-Ion batteries in December 2016; the second set of six was launched in September 2018 and installed in March 2019. The third set of six were launched in September 2019. Three batteries were installed in September 2019, with the remaining three to be installed in January 2020. This paper will include a brief overview of the ISS Li-Ion battery system architecture, start up of the second and third set of 6 batteries and the on-orbit status of all 18 batteries, plus the status of the Li-Ion cell life testing.