Visualization of Space-Time Ambiguities to be Explored by NASA GEC Mission with a Critique of Synthesized Measurements for Different GEC Mission Scenarios

The Grant supported research addressing the question of how the NASA Solar Terrestrial Probes (STP) Mission called Geospace electrodynamics Connections (GEC) will resolve space-time structures as well as collect sufficient information to solve the coupled thermosphere-ionosphere- magnetosphere dynamics and electrodynamics. The approach adopted was to develop a high resolution in both space and time model of the ionosphere-thermosphere (I-T) over altitudes relevant to GEC, especially the deep-dipping phase. This I-T model was driven by a high- resolution model of magnetospheric-ionospheric (M-I) coupling electrodynamics. Such a model contains all the key parameters to be measured by GEC instrumentation, which in turn are the required parameters to resolve present-day problems in describing the energy and momentum coupling between the ionosphere-magnetosphere and ionosphere-thermosphere. This model database has been successfully created for one geophysical condition; winter, solar maximum with disturbed geophysical conditions, specifically a substorm. Using this data set, visualizations (movies) were created to contrast dynamics of the different measurable parameters. Specifically, the rapidly varying magnetospheric E and auroral electron precipitation versus the slower varying ionospheric F-region electron density, but rapidly responding E-region density.

Sojka, Jan J.↗

Visualization of Space-Time Ambiguities to be Explored by the NASA GEC Mission with a Critique of Synthesized Measurements for Different GEC Mission Scenarios

The objective of this grant was to study how a multi-satellite mission configuration can be optimized for maximum exploratory scientific return. NASA's Solar Terrestrial Probe (STP) concept mission Geospace Electrodynamic Connections (GEC) was the target mission for this pilot study. GEC prime mission characteristics were two fold: (i) a series of three satellites in the same orbit plane with differential spacing, and (ii) a deep-dipping phase in which these satellites could dip to altitudes as low as 130 km to explore the lower ionosphere and thermosphere. Each satellite would carry a full suite of plasma and neutral in-situ sensors and have the same dipping capability. This latter aspect would be envisaged as a series, up to 10, of deep-dipping campaigns, each lasting 10 days during which the perigee would be lowered to the desired probing depth. The challenge in optimization is to establish the scientific problems that can best be addressed by varying or selecting satellite spacing during a two-year mission while also interspersing, in this two year time frame, the deep-dipping campaigns. Although this sounds like a straightforward trade-off situation, it is complicated by the orbit precession in local time, the location of perigee, and that even the dipping campaigns will have preferred satellite spacing requirements.

Sojka, Jan J.↗

Electronic structure of single-layer superlattices (GeC){sub 1}(SiC){sub 1}, (SnC){sub 1}(SiC){sub 1}, and (SnC){sub 1}(GeC){sub 1}

The crystal and electronic structures of GeC, SiC, and SnC crystals and superlattices based on them, GeC/SiC, SnC/SiC, and SnC/GeC, are modeled within density functional theory. The equilibrium lattice constants are obtained, the band spectra and densities of states are calculated, and the specific features of the formation of the valence band and chemical bonding in these crystals and superlattices are studied.

36 MATERIALS SCIENCE↗

Epitaxial growth and electrical transport properties of Cr{sub 2}GeC thin films

Cr{sub 2}GeC thin films were grown by magnetron sputtering from elemental targets. Phase-pure Cr{sub 2}GeC was grown directly onto Al{sub 2}O{sub 3}(0001) at temperatures of 700-800 deg. C. These films have an epitaxial component with the well-known epitaxial relationship Cr{sub 2}GeC(0001)//Al{sub 2}O{sub 3}(0001) and Cr{sub 2}GeC(1120)//Al{sub 2}O{sub 3}(1100) or Cr{sub 2}GeC(1120)//Al{sub 2}O{sub 3}(1210). There is also a large secondary grain population with (1013) orientation. Deposition onto Al{sub 2}O{sub 3}(0001) with a TiN(111) seed layer and onto MgO(111) yielded growth of globally epitaxial Cr{sub 2}GeC(0001) with a virtually negligible (1013) contribution. In contrast to the films deposited at 700-800 deg. C, the ones grown at 500-600 deg. C are polycrystalline Cr{sub 2}GeC with (1010)-dominated orientation; they also exhibit surface segregations of Ge as a consequence of fast Ge diffusion rates along the basal planes. The room-temperature resistivity of our samples is 53-66 {mu}{Omega}cm. Temperature-dependent resistivity measurements from 15-295 K show that electron-phonon coupling is important and likely anisotropic, which emphasizes that the electrical transport properties cannot be understood in terms of ground state electronic structure calculations only.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermodynamics and kinetics of 2D g-GeC monolayer as an anode materials for Li/Na-ion batteries

Development of high capacity anode materials is one of the essential strategies for next-generation high-performance Li/Na-ion batteries. Rational design, using density functional theory, can expedite the discovery of these anode materials. Here, we propose a new anode material, germanium carbide, g-GeC, for Li/Na-ion batteries. Our results show that g-GeC possesses both benefits of the high stability of graphene and the strong interaction between Li/Na and germanene. The single-layer germanium carbide, g-GeC, can be lithiated/sodiated on both sides yielding Li 2 GeC and Na 2 GeC with a storage capacity as high as 633 mA h/g. Besides germagraphene’s 2D honeycomb structure, fast charge transfer, and high (Li/Na)-ion diffusion and negligible volume change further enhance the anode performance. These findings provide valuable insights into the electronic characteristics of newly predicted 2D g-GeC nanomaterial as a promising anode for (Li/Na)-ion batteries.

25 ENERGY STORAGE↗

Effect of high hydrostatic pressure on structural stability of Ti{sub 3}GeC{sub 2}: A first-principles investigation

An investigation into the structural stability, electronic and elastic properties of Ti{sub 3}GeC{sub 2} under high hydrostatic pressure was conducted using first-principles calculations based on density functional theory (DFT). From the energy and enthalpy calculations, and the variations of elastic constants with pressure, we conclude that {alpha}-Ti{sub 3}GeC{sub 2} is most stable upon compression to 100 GPa, which is not consistent with the nonhydrostatic in situ synchrotron X-ray diffraction studies. The higher structural stability was analyzed in terms of electronic level. The absence of band gap at the Fermi level and the finite value of the density of states at the Fermi energy reveal the metallic behavior of all polymorphs of Ti{sub 3}GeC{sub 2}. -- Graphical abstract: The less phase stability of {beta}-Ti{sub 3} SiC{sub 2} compared to that of {alpha}-Ti{sub 3} SiC{sub 2} can be interpreted by the states between -6.0 and 3.6 eV shift toward the higher energy region for {beta}-Ti{sub 3} SiC{sub 2} Display Omitted Research highlights: > From the energy and enthalpy calculations of polymorphs for Ti{sub 3}GeC{sub 2}, we can conclude that Ti{sub 3}GeC{sub 2} possessed higher stable structural stability under pressure to 100 GPa, which is not consistent with the nonhydrostatic experiments. > The higher stable structure of Ti{sub 3}GeC{sub 2} is testified by the calculated variations of elastic constants with pressure. > The reasons for this higher stable phase stability were discussed in terms of the electronic level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Orbit Optimization for the Geospace Electrodynamics Connections (GEC) Mission

The Geospace Electrodynamics Connections (GEC) mission plan is to launch multiple spacecraft to perform in-situ atmospheric science in the lower ionosphere. There is limited experience in this low altitude region with the Atmospheric Explorer-C (AE-C) being the last spacecraft to explore this region in 1973. AE-C flew an eccentric orbit using maneuvers to lower its perigee to near 130 km at various times during its mission. GEC will advance the science performed by AE-C by performing multiple low-perigee, atmospheric dipping campaigns for extended durations. AE-C kept its perigee near 130 km for only a total of roughly 1 day. Furthermore, GEC plans to carry a more diverse suite of instruments and will be able to capture different temporal and spatial phenomena through the use of multiple spacecraft flying in a string of pearls formation. The mission analysis for GEC has been broken into two parts: the analysis of the parking orbit with the dipping campaigns and the examination of the multi-satellite dynamics of the GEC constellation. The analysis described in this paper examines the capability to meet the requirements necessary to support the 10 dipping campaigns using a single spacecraft as a representative of all three in the constellation. Further analysis is being performed to analyze the multi-satellite nature of the GEC mission.

Mesarch, Michael A.↗

Blade System Design Study. Part II, final project report (GEC).

As part of the U.S. Department of Energy's Low Wind Speed Turbine program, Global Energy Concepts LLC (GEC)1 has studied alternative composite materials for wind turbine blades in the multi-megawatt size range. This work in one of the Blade System Design Studies (BSDS) funded through Sandia National Laboratories. The BSDS program was conducted in two phases. In the Part I BSDS, GEC assessed candidate innovations in composite materials, manufacturing processes, and structural configurations. GEC also made recommendations for testing composite coupons, details, assemblies, and blade substructures to be carried out in the Part II study (BSDS-II). The BSDS-II contract period began in May 2003, and testing was initiated in June 2004. The current report summarizes the results from the BSDS-II test program. Composite materials evaluated include carbon fiber in both pre-impregnated and vacuum-assisted resin transfer molding (VARTM) forms. Initial thin-coupon static testing included a wide range of parameters, including variation in manufacturer, fiber tow size, fabric architecture, and resin type. A smaller set of these materials and process types was also evaluated in thin-coupon fatigue testing, and in ply-drop and ply-transition panels. The majority of materials used epoxy resin, with vinyl ester (VE) resin also used for selected cases. Late in the project, testing of unidirectional fiberglass was added to provide an updated baseline against which to evaluate the carbon material performance. Numerous unidirectional carbon fabrics were considered for evaluation with VARTM infusion. All but one fabric style considered suffered either from poor infusibility or waviness of fibers combined with poor compaction. The exception was a triaxial carbon-fiberglass fabric produced by SAERTEX. This fabric became the primary choice for infused articles throughout the test program. The generally positive results obtained in this program for the SAERTEX material have led to its being used in innovative prototype blades of 9-m and 30-m length, as well as other non-wind related structures.

17 WIND ENERGY↗

Understanding Plasma Interactions with the Atmosphere: The Geospace Electrodynamic Connections (GEC) Mission

The Geospace Electrodynamic Connections (GEC) mission is a multispacecraft Solar-Terrestrial Probe that has been specifically designed to advance the level of physical insight of our understanding of the coupling among the ionosphere, thermosphere, and magnetosphere. GEC is NASA's fifth Solar-Terrestrial Probe. Through multipoint measurements in the Earth's ionosphere-thermosphere (I-T) system, GEC will (i) discover the spatial and temporal scales on which magnetospheric energy input into the I-T region occurs, (ii) determine the spatial and temporal scales for the response of the I-T system to this input of energy, and (iii) quantify the altitude dependence of the response.

Source record↗

Relationships among diurnal variations of polar night cloud, precipitation, surface temperatures, and the fair-weather return current of the global electric circuit (GEC)

Over the past five years (June 2017-current), the vertical electric field (E z ) as well as numerous cloud, precipitation and radiation properties have been monitored at the Department of Energy-Atmospheric Radiation Measurement (DOE ARM) North Slope of Alaska (NSA) field site. Comparisons between the composite diurnal averaged fair-weather E z , and composite ceilometer derived cloud base height during the polar night, reveal a significant correlation between the parameters (r = 0.62), supporting previous studies that there is high correlation between local electric field and cloud properties. With the use of extensive instrumentation at the site, such as the Micro Pulse Lidar (MPL), Ka-band Zenith Radar (KAZR), ceilometer, SKYRAD, Precipitation Imaging Package (PIP), among others, this study provides a more comprehensive examination of the diurnal cycle of cloud and precipitation properties along with the localized fair-weather return current of the larger Global Electric Circuit (GEC) system. Comparisons between the composite diurnal averaged fair-weather E z , and cloud thickness, maximum column backscatter, and precipitation particle counts all show similar diurnal variability during the polar night, indicating that during the largest magnitude fair weather E z time periods, clouds bases tend to be higher, clouds are thicker, have a larger column backscatter, and display more precipitating particles. Furthermore, a slight diurnal variability in the polar night surface temperature was found to be highly correlated (r = 0.87) to the longwave downwelling irradiance measured by SKYRAD, indicating that the variations in the physical properties of local clouds could modulate the diurnal polar night surface temperature variability on the order of 0.5 °C/day. In conclusion, these findings emphasize the importance and global nature of the GEC system, with the global aggregate of thunderstorms and electrified clouds potentially influencing polar night cloud properties as well as diurnal wintertime polar surface temperature variation.

54 ENVIRONMENTAL SCIENCES↗

Materials Data on GeC by Materials Project

GeC is Zincblende, Sphalerite structured and crystallizes in the cubic F-43m space group. The structure is three-dimensional. Ge4+ is bonded to four equivalent C4- atoms to form corner-sharing GeC4 tetrahedra. All Ge–C bond lengths are 1.99 Å. C4- is bonded to four equivalent Ge4+ atoms to form corner-sharing CGe4 tetrahedra.

36 MATERIALS SCIENCE↗

Materials Data on GeC by Materials Project

GeC is Halite, Rock Salt structured and crystallizes in the cubic Fm-3m space group. The structure is three-dimensional. Ge4+ is bonded to six equivalent C4- atoms to form a mixture of edge and corner-sharing GeC6 octahedra. The corner-sharing octahedral tilt angles are 0°. All Ge–C bond lengths are 2.19 Å. C4- is bonded to six equivalent Ge4+ atoms to form a mixture of edge and corner-sharing CGe6 octahedra. The corner-sharing octahedral tilt angles are 0°.

36 MATERIALS SCIENCE↗

Materials Data on GeC by Materials Project

GeC is Wurtzite structured and crystallizes in the hexagonal P6_3mc space group. The structure is three-dimensional. Ge4+ is bonded to four equivalent C4- atoms to form corner-sharing GeC4 tetrahedra. There is three shorter (1.99 Å) and one longer (2.00 Å) Ge–C bond length. C4- is bonded to four equivalent Ge4+ atoms to form corner-sharing CGe4 tetrahedra.

36 MATERIALS SCIENCE↗

A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO

This report addresses uncertainties pertaining to brachytherapy single-source dosimetry preceding clinical use. The International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement (GUM) and the National Institute of Standards and Technology (NIST) Technical Note 1297 are taken as reference standards for uncertainty formalism. Uncertainties in using detectors to measure or utilizing Monte Carlo methods to estimate brachytherapy dose distributions are provided with discussion of the components intrinsic to the overall dosimetric assessment. Uncertainties provided are based on published observations and cited when available. The uncertainty propagation from the primary calibration standard through transfer to the clinic for air-kerma strength is covered first. Uncertainties in each of the brachytherapy dosimetry parameters of the TG-43 formalism are then explored, ending with transfer to the clinic and recommended approaches. Dosimetric uncertainties during treatment delivery are considered briefly but are not included in the detailed analysis. For low- and high-energy brachytherapy sources of low dose rate and high dose rate, a combined dosimetric uncertainty <5% (k=1) is estimated, which is consistent with prior literature estimates. Recommendations are provided for clinical medical physicists, dosimetry investigators, and source and treatment planning system manufacturers. These recommendations include the use of the GUM and NIST reports, a requirement of constancy of manufacturer source design, dosimetry investigator guidelines, provision of the lowest uncertainty for patient treatment dosimetry, and the establishment of an action level based on dosimetric uncertainty. These recommendations reflect the guidance of the American Association of Physicists in Medicine (AAPM) and the Groupe Europeen de Curietherapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) for their members and may also be used as guidance to manufacturers and regulatory agencies in developing good manufacturing practices for sources used in routine clinical treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Guidelines by the AAPM and GEC-ESTRO on the use of innovative brachytherapy devices and applications: Report of Task Group 167

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used in the evaluation of innovative devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining the equivalence of the innovative treatment modality to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of innovative radiotherapy devices or applications is a critical part in which physicists should be actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative brachytherapy devices and applications and includes evaluation of (1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, (2) risks and benefits from a regulatory and safety perspective, and (3) resource assessment and preparedness. Further, it is suggested that any developed calibration methods be traceable to a primary standards dosimetry laboratory (PSDL) such as the National Institute of Standards and Technology in the U.S. or to other PSDLs located elsewhere such as in Europe. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the Accredited Dosimetry Calibration Laboratories in the U.S. is encouraged before a source is introduced into widespread routine clinical use. The American Association of Physicists in Medicine and the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO) have developed guidelines for the safe and consistent application of brachytherapy using innovative devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. Nuclear Regulatory Commission, U.S. Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, U.S. Food and Drug Administration, European Commission for CE Marking (Conformité Européenne), and institutional review boards and radiation safety committees.

60 APPLIED LIFE SCIENCES↗

Geothermal Economics Calculator (GEC): Additional modifications to final report as per GTP's request

This report will discuss the methods and the results from economic impact analysis applied to the development of Enhanced Geothermal Systems (EGS), conventional hydrothermal, low temperature geothermal and coproduced fluid technologies resulting in electric power production. As part of this work, the Energy & Geoscience Institute (EGI) has developed a web-based Geothermal Economics Calculator (Geothermal Economics Calculator (GEC)) tool that is aimed at helping the industry perform geothermal systems analysis and study the associated impacts of specific geothermal investments or technological improvements on employment, energy and environment. It is well-known in the industry that geothermal power projects will generate positive economic impacts for their host regions. Our aim in the assessment of these impacts includes quantification of the increase in overall economic output due to geothermal projects and of the job creation associated with this increase. Such an estimate of economic impacts of geothermal investments on employment, energy and the environment will also help us understand the contributions that the geothermal industry will have in achieving a sustainable path towards energy production.

15 GEOTHERMAL ENERGY↗

Enhancement of X-ray performance with new GEC charged coupled devices (CCD)

Samples of two GEC charge coupled devices with enhanced X-ray performance have been tested. The P8607, fabricated with reduced linear dimensions, gives the lowest detector noise reported for Fe-55 with a CCD. The deep depletion device P8600-HR gives the best combination of energy resolution and quantum efficiency at 6 keV. The energy resolution vs quantum efficiency trade-off curve are discussed.

Schwartz, D. A.↗

Fourier Transform Infrared Spectroscopy of CF4 on the GEC Reference Cell

Fourier Transform Infrared Spectroscopy (FTIR) has been used to characterize inductively coupled CF4 plasmas in a GEC Reference Cell in-situ In examining these FTIR spectra, several assumptions and approximations of FTIR analysis are addressed. This includes the density dependence of cross-sections, non-linear effects in the addition of overlapping bands and the effect of spatial variations in density and temperature, This analysis demonstrates that temperatures extracted from MR spectra may provide a poor estimate of the true neutral plasma temperature. The FTIR spectra are dominated by unreacted CF, accounting for 40-60% of the gas products. The amount of CF4 consumption is found to have a marked dependence on power, and is nearly independent of pressure in the range of 10-50 mtorr. Small amounts of C2F6 are observed at low power. Also observed are etching products from the quartz window SiF4 COF2 and CO which occur in approximately equal ratios and together account for less than 10% of the gas. The concentrations of these species are nearly independent of pressure. CFx radicals are below the detection limit of this apparatus (approx. 1012/cc).