Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GdCl3”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Materials Data on GdCl3 by Materials Project

GdCl3 crystallizes in the hexagonal P6_3/m space group. The structure is three-dimensional. Gd3+ is bonded in a 9-coordinate geometry to nine equivalent Cl1- atoms. There are six shorter (2.82 Å) and three longer (3.00 Å) Gd–Cl bond lengths. Cl1- is bonded in a distorted trigonal non-coplanar geometry to three equivalent Gd3+ atoms.

36 MATERIALS SCIENCE↗

Calcium-independent activation of extracellular signal-regulated kinases 1 and 2 by cyclic strain

We have previously demonstrated that cyclic strain induces extracellular signal-regulated kinases 1 and 2 (ERK1/2) activation in endothelial cells (EC). The aim of this study was to investigate the effect of Ca2+ on the activation of ERK1/2. Bovine aortic EC were pretreated with a chelator of extracellular Ca2+, ethylaneglycol-bis(aminoethylether)-tetra-acetate (EGTA), a depleter of Ca2+ pools, 2,5-Di-(tert-butyl)-1,4-benzohydroquinone (BHQ), or a Ca2+ channel blocker, GdCl3, and subjected to an average 10 % strain at a rate of 60 cycles/min for 10 min. BHQ and GdCl3 did not inhibit the strain-induced ERK1/2 activation. Chelation of normal extracellular Ca2+ (1.8 mM) medium with EGTA (3 mM) acutely stimulated baseline phosphorylation and activation of ERK1/2, thereby obscuring any strain-induced activation of ERK1/2. However, in EC preincubated for 24 hours in Ca2+-free medium, elevated baseline phosphorylation was minimally activated by EGTA (200 microM) such that cyclic strain stimulated ERK1/2 in the presence or absence of BHQ. These results suggest a Ca2+ independence of the ERK1/2 signaling pathway by cyclic strain. Copyright 1998 Academic Press.

NASA Discipline Cell Biology↗

Novel Electrochemical Technique: Serial Open Circuit Potentiometry to Examine the Separability of Lanthanides in Molten Salts

The accumulation of lanthanide fission products in molten salts reduces the efficiency of pyroprocessing used nuclear fuel. Lanthanide fission products are notoriously difficult to separate due to their similar physical and electrical properties. We developed a novel electrochemical technique called serial open circuit potentiometry (SOCP) which allows us to delineate between metal deposition reactions with similar reduction potentials to great precision. SOCP has several advantages over traditional open circuit potentiometry including its ability to create 3D plots that describe all metal deposition reactions in a system. This information can be used to precisely determine equilibrium potentials of metal deposition reactions and quantify their error, determine nucleation potentials, and determine the nucleation and growth mechanism. In this work, we demonstrated the effectiveness of SOCP by studying molten salt mixtures containing CeCl3, GdCl3, and both CeCl3 and GdCl3 in LiCl-KCl eutectic.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Activation of the CaR-CSE/H2S pathway confers cardioprotection against ischemia-reperfusion injury

Ischemia-reperfusion (I/R) injury is a multifactorial process triggered when an organ is subjected to transiently reduced blood supply. The result is a cascade of pathological complications and organ damage due to the production of reactive oxygen species following reperfusion. The present study aims to evaluate the role of activated calcium-sensing receptor (CaR)-cystathionine γ-lyase (CSE)/hydrogen sulfide (H2S) pathway in I/R injury. Firstly, an I/R rat model with CSE knockout was constructed. Transthoracic echocardiography, TTC and HE staining were performed to determine the cardiac function of rats following I/R Injury, followed by TUNEL staining observation on apoptosis. Besides, with the attempt to better elucidate how CaR-CSE/H2S affects I/R, in-vitro culture of human coronary artery endothelial cells (HCAECs) was conducted with gadolinium chloride (GdCl3, a CaR agonist), H{sub 2}O{sub 2}, siRNA against CSE (siCSE), or W7 (a CaM inhibitor). The interaction between CSE and CaM was subsequently detected. Plasma oxidative stress indexes, H2S and CSE, and apoptosis-related proteins were all analyzed following cell apoptosis. We found that H2S elevation led to the improvement whereas CSE knockdown decreased cardiac function in rats with I/R injury. Moreover, oxidative stress injury in I/R rats with CSE knockout was aggravated, while the increased expression of H2S and CSE in the aortic tissues resulted in alleviated the oxidative stress injury. Moreover, increased H2S and CSE levels were found to inhibit cell apoptotic ability in the aortic tissues after I/R injury, thus attenuating oxidative stress injury, accompanied by inhibited expression of apoptosis-related proteins. In HCAECs following oxidative stress treatment, siCSE and CaM inhibitor were observed to reverse the protection of CaR agonist. Coimmunoprecipitation assay revealed the interaction between CSE and CaM. Taken together, all above-mentioned data provides evidence that activation of the CaR-CSE/H2S pathway may confer a potent protective effect in cardiac I/R injury.

60 APPLIED LIFE SCIENCES↗

A New Small Nano-Kelvin Resolution Thermometer for Low Temperature Experiments

A small, high resolution paramagnetic susceptibility thermometer was developed using a GdCl3 paramagnetic salt. The device uses a SQUID (Superconducting Quantum Interference Device) magnetometer to determine the temperature dependent magnetization of the salt in a magnetic field. The magnetic field is provided by a pair of small samarium cobalt permanent magnet disks situated inside the thermometer housing. The eliminates the need for a heavy, charging solenoid used in a conventional SQUID based magnetic thermometer system. This thermometer can resolve approximately 10 (exp -9)K near the liquid-gas critical point of He-3(approximately 3.31K). The drift rate of the thermometer was measured to be less than 2 x 10 (exp -13) K per second. This light weight thermometer (approximately 7 g) is a candidate for use in future low temperature Space Shuttle and International Space Station experiments. The present thermometer design easily permits a variety of magnetic materials for use in other applications.

Welander, Paul↗

A Small Nano-Kelvin Resolution Thermometer for Low Temperature Experiments in Space

A small high resolution paramagnetic susceptibility thermometer was developed using a GdCl3 paramagnetic salt. The device uses a SQUID magnetometer to determine the temperature dependent magnetization of the salt in a magnetic field. The required magnetic field is provided by a pair of small SmCo permanent magnet disks situated inside the thermometer housing. This eliminates the use of a heavy charging solenoid in a conventional SQUID based magnetic thermometer system using a flux tube. This thermometer can resolve approximately 10(exp -9)K near the liquid-gas critical point of The (approx. 3.31K). The drift in the thermometer is less than 2 x 10(exp -13) K/s. This light weighted thermometer (approx. 7 g) is a candidate for use in future International Space Station flight low temperature experiments.

Welander, Paul↗

High Resolution Thermometry for EXACT

High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.

Panek, J. S.↗

Salt Sample Statistical Study

Historically there has, at times, been large variability in measured uranium concentration amongst salt samples taken at the same time from the electrorefiner with relative standard deviations ranging from 0.59% up to a high of 114%. This has led to uncertainty in the actual uranium content of the salt. A series of surrogate experiments were performed with gadolinium to study the effects of Li2O, Gd2O3, and Gd metal additions to an LiCl-KCl-GdCl3 salt on the gadolinium content of the salt. These experiments showed no increase in salt sample variability following the additions of the mentioned species, indicating that the carryover of these species from the oxide reduction process may not lead to the historic variability issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗