Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Gascon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Parallel Hybrid Turboprop Performance Modeling and Optimization

NASA’s Electrified Powertrain Flight Demonstration (EPFD) project conducts ground and flight tests of integrated Megawatt (MW) class hybrid-electric powertrain systems on regional turboprop aircraft demonstrators. To meet the increased demand for assessment of potential capabilities and benefits from these novel vehicle configurations, NASA is developing tooling and models to estimate the performance of hybridized regional turboprops. This paper covers the development of a parametrically driven performance model for a De Havilland Canada Dash 8-400 (Q400) regional turboprop integrated with a novel parallel hybrid architecture using the Gascon framework. Gascon is a modern reimplementation of the General Aviation Synthesis Program (GASP) built using the Condor mathematical modeling framework in Python. Within Gascon, a parametric representation of the parallel hybrid architecture was synthesized, which features the electric motor coupled to the power turbine. This capability allows for in-the-loop optimization of the parametric parallel hybrid architecture to characterize the mission capabilities and fuel savings of the design and determine optimal power scheduling strategies for efficient electric power management for a given mission. The study shows that a fuel savings of up to 20% can be achieved, but that increased fuel savings comes at the expense of payload capacity.

Gascon

Parallel Hybrid Turboprop Performance Modeling and Optimization

NASA’s Electrified Powertrain Flight Demonstration (EPFD) project conducts ground and flight tests of integrated Megawatt (MW) class hybrid-electric powertrain systems on regional turboprop aircraft demonstrators. To meet the increased demand for assessment of potential capabilities and benefits from these novel vehicle configurations, NASA is developing tooling and models to estimate the performance of hybridized regional turboprops. This paper covers the development of a parametrically driven performance model for a De Havilland Canada Dash 8-400 (Q400) regional turboprop integrated with a novel parallel hybrid architecture using the Gascon framework. Gascon is a modern reimplementation of the General Aviation Synthesis Program (GASP) built using the Condor mathematical modeling framework in Python. Within Gascon, a parametric representation of the parallel hybrid architecture was synthesized, which features the electric motor coupled to the power turbine. This capability allows for in-the-loop optimization of the parametric parallel hybrid architecture to characterize the mission capabilities and fuel savings of the design and determine optimal power scheduling strategies for efficient electric power management for a given mission. The study shows that a fuel savings of up to 20% can be achieved, but that increased fuel savings comes at the expense of payload capacity.

Gascon

GASP Advancements With Symbolic Computations, Optimization, and Decoupled Numerical Methods

NASA is exploring advancements in hybrid-electric propulsion concepts for aircraft design. A new analysis capability has been deployed at NASA’s Ames Research Center using a new mathematical modeling framework in Python that leverages symbolic representation of mathematical expressions, optimization-based problem formulations, and standalone numerical methods. This capability, called Gascon, has been verified against NASA’s General Aviation Synthesis Program (GASP) results for several vehicles that exercise the analysis capability for a variety of aircraft classes and engine models, including both turbofans and turboprops. We believe this capability will set the stage for more rapid development of novel aircraft models with more flexible design assessments using optimization, and more traceable analysis for reproducibility. Additionally, a novel Pareto optimization-based design space exploration that shows the trade between range flown and fuel burn by manipulating the thrust split during cruise for a true parallel hybrid aircraft was developed by leveraging the unique features of Gascon.

aircraft design

Autoencoder-Based Anomaly Detection System for Online Data Quality Monitoring of the CMS Electromagnetic Calorimeter

The CMS detector is a general-purpose apparatus that detects high-energy collisions produced at the LHC. Online data quality monitoring of the CMS electromagnetic calorimeter is a vital operational tool that allows detector experts to quickly identify, localize, and diagnose a broad range of detector issues that could affect the quality of physics data. A real-time autoencoder-based anomaly detection system using semi-supervised machine learning is presented enabling the detection of anomalies in the CMS electromagnetic calorimeter data. A novel method is introduced which maximizes the anomaly detection performance by exploiting the time-dependent evolution of anomalies as well as spatial variations in the detector response. The autoencoder-based system is able to efficiently detect anomalies, while maintaining a very low false discovery rate. The performance of the system is validated with anomalies found in 2018 and 2022 LHC collision data. In addition, the first results from deploying the autoencoder-based system in the CMS online data quality monitoring workflow during the beginning of Run 3 of the LHC are presented, showing its ability to detect issues missed by the existing system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Searching for beyond the Standard Model physics using the improved description of 100 Mo $2\nu \beta \beta$ decay spectral shape with CUPID-Mo

The current experiments searching for neutrinoless double-β ($0\nu \beta \beta$) decay also collect large statistics of Standard Model allowed two-neutrino double-β ($2\nu \beta \beta$ ) decay events. These can be used to search for Beyond Standard Model (BSM) physics via $2\nu \beta \beta$ decay spectral distortions. 100 Mo has a natural advantage due to its relatively short half-life, allowing higher $2\nu \beta \beta$ decay statistics at equal exposures compared to the other isotopes. We demonstrate the potential of the dual read-out bolometric technique exploiting a 100 Mo exposure of 1.47 kg years, acquired in the CUPID-Mo experiment at the Modane underground laboratory (France). We set limits on $0\nu \beta \beta$ decays with the emission of one or more Majorons, on $2\nu \beta \beta$ decay with Lorentz violation, and $2\nu \beta \beta$ decay with a sterile neutrino emission. In this analysis, we investigate the systematic uncertainty induced by modeling the $2\nu \beta \beta$ decay spectral shape parameterized through an improved model, an effect never considered before. This work motivates searches for BSM processes in the upcoming CUPID experiment, which will collect the largest amount of $2\nu \beta \beta$ decay events among the next-generation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

CUPID, the Cuore upgrade with particle identification

CUPID, the CUORE Upgrade with Particle Identification, is a next-generation experiment to search for neutrinoless double beta decay (0 νββ ) and other rare events using enriched Li 2 100 MoO 4 scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for 0 νββ of 100 Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10 −4 cts/(keV·kg·yr), 240 kg isotope mass, 5 keV FWHM energy resolution at 3 MeV and 10 live-years of data taking, CUPID will have a 90% C.L. half-life exclusion sensitivity of 1.8 · 10 27 yr, corresponding to an effective Majorana neutrino mass ( m ββ ) sensitivity of 9–15 meV, and a 3σ discovery sensitivity of 1 · 10 27 yr, corresponding to an m ββ range of 12–21 meV.

Alfonso, K. [Virginia Polytechnic Institute and St

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Publisher Erratum: A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

In the originally published version of this article, several errors were identified in the author list and acknowledgements section. These have now been corrected as follows: Corrections to the Author List: Barrera has been corrected to Barresi. Copello (affiliation 18) has been corrected to Copello (affiliation 19). F. De Domizio has been corrected to S. Di Domizio. Figueros-Feliciamo has been corrected to Figueroa-Feliciano. Mancarella (affiliations 8, 17) has been corrected to Mancarella (affiliations 8, 18). Manenti (affiliations 18, 19) has been corrected to Manenti (affiliations 19, 20). Mayer (affiliations 3, 20, 31) has been corrected to Mayer (affiliations 3, 21, 31). Pagot has been corrected to Pageot. Puranam (affiliation 20) has been corrected to Puranam (affiliation 21). O. Penek has been corrected to Ö. Penek. L. Pettinacci has been corrected to V. Pettinacci. P. Pirro has been corrected to S. Pirro. Previtale has been corrected to Previtali. Rappoldi (affiliation 18) has been corrected to Rappoldi (affiliation 19). Raselli (affiliation 18) has been corrected to Raselli (affiliation 19). Rizzoli (affiliations 8, 17) has been corrected to Rizzoli (affiliations 8, 18). Rossella (affiliation 18) has been corrected to Rossella (affiliation 19). Correction to the Acknowledgements Section: The following grant numbers were missing and have now been added: This work was supported by NSF-PHY-2412377 and NSF-PHY-1913374. Additionally, on page 11, Section 5, second line, the chemical formula was incorrectly given as Li 2 MO 4 . The correct formula is Li 2 MoO 4 . The original article has been updated to reflect these corrections. The publisher apologizes for the inconvenience.

Alfonso, K. [Virginia Polytechnic Institute and St

Publisher Erratum: CUPID, the Cuore upgrade with particle identification

Publisher Erratum: Eur. Phys. J. C (2025) 85:737 https://doi.org/10.1140/epjc/s10052-025-14352-1 The author M. Pavan (affiliations 9 and 10) was missing from the published author list. The online version of the article has been updated to include the author. Additionally, affiliations 4 and 17 have been corrected to reflect the proper institutional order. The publisher apologizes for the inconvenience caused.

Alfonso, K. [Virginia Polytechnic Institute and St

Sensitivity of the CUPID experiment to $0\nu \beta \beta$ decay of 100 Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0\nu \beta \beta$ ) of 100 Mo using Li 2 MoO 4 scintillating crystals. It will operate 1596 crystals at ~10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for α rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0\nu \beta \beta$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of 1.0 x 10 –4 counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \textrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{\beta \beta } < \ 9.6$ – 28 meV. The Frequentist discovery sensitivity (3σ ) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \textrm{yr}$, corresponding to $\hat{m}_{\beta \beta }= \ 12$ – 36 meV.

Alfonso, K. [Virginia Polytechnic Institute and St

ECFA Higgs, electroweak, and top Factory Study

The ECFA Higgs, electroweak, and top Factory Study ran between 2021 and 2025 as a broad effort across the experimental and theoretical particle physics communities, bringing together participants from many different proposed future collider projects. Activities across three main working groups advanced the joint development of tools and analysis techniques, fostered new considerations of detector design and optimisation, and led to a new set of studies resulting in improved projected sensitivities across a wide physics programme. This report demonstrates the significant expansion in the state-of-the-art understanding of the physics potential of future e+e- Higgs, electroweak, and top factories, and has been submitted as input to the 2025 European Strategy for Particle Physics Update.

Altmann, J. [Monash U.]

The IDEA detector concept for FCC-ee

A detector concept, named IDEA, optimized for the physics and running conditions at the FCC-ee is presented. After discussing the expected running conditions and the main physics drivers, a detailed description of the individual sub-detectors is given. These include: a very light tracking system with a powerful vertex detector inside a large drift chamber surrounded by a silicon wrapper, a high resolution dual readout crystal electromagnetic calorimeter, an HTS based superconducting solenoid, a dual readout fiber calorimeter and three layers of muon chambers embedded in the magnet flux return yoke. Some examples of the expected detector performance, based on fast and full simulation, are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

A Note on the Temporary Misregistration of Landsat-8 Operational Land Imager (OLI) and Sentinel-2 Multi Spectral Instrument (MSI) Imagery

The Landsat-8 and Sentinel-2 sensors provide multi-spectral image data with similar spectral and spatial characteristics that together provide improved temporal coverage globally. Both systems are designed to register Level 1 products to a reference image framework, however, the Landsat-8 framework, based upon the Global Land Survey images, contains residual geolocation errors leading to an expected sensor-to-sensor misregistration of 38 m (2sigma). These misalignments vary geographically but should be stable for a given area. The Landsat framework will be readjusted for consistency with the Sentinel-2 Global Reference Image, with completion expected in 2018. In the interim, users can measure Landsat-to-Sentinel tie points to quantify the misalignment in their area of interest and if appropriate to reproject the data to better alignment.

Storey, James

Atmospheric Correction Inter-Comparison eXercise

The Atmospheric Correction Inter-comparison eXercise (ACIX) is an international initiative with the aim to analyse the Surface Reflectance (SR) products of various state-of-the-art atmospheric correction (AC) processors. The Aerosol Optical Thickness (AOT) and Water Vapour (WV) are also examined in ACIX as additional outputs of AC processing. In this paper, the general ACIX framework is discussed; special mention is made of the motivation to initiate the experiment, the inter-comparison protocol, and the principal results. ACIX is free and open and every developer was welcome to participate. Eventually, 12 participants applied their approaches to various Landsat-8 and Sentinel-2 image datasets acquired over sites around the world. The current results diverge depending on the sensors, products, and sites, indicating their strengths and weaknesses. Indeed, this first implementation of processor inter-comparison was proven to be a good lesson for the developers to learn the advantages and limitations of their approaches. Various algorithm improvements are expected, if not already implemented, and the enhanced performances are yet to be assessed in future ACIX experiments.

Processors inter-comparison

Observations and Recommendations for the Calibration of Landsat 8 OLI and Sentinel 2 MSI for Improved Data Interoperability

Combining data from multiple sensors into a single seamless time series, also known as data interoperability, has the potential for unlocking new understanding of how the Earth functions as a system. However, our ability to produce these advanced data sets is hampered by the differences in design and function of the various optical remote-sensing satellite systems. A key factor is the impact that calibration of these instruments has on data interoperability. To address this issue, a workshop with a panel of experts was convened in conjunction with the Pecora 20 conference to focus on data interoperability between Landsat and the Sentinel 2 sensors. Four major areas of recommendation were the outcome of the workshop. The first was to improve communications between satellite agencies and the remote-sensing community. The second was to adopt a collections-based approach to processing the data. As expected, a third recommendation was to improve calibration methodologies in several specific areas. Lastly, and the most ambitious of the four, was to develop a comprehensive process for validating surface reflectance products produced from the data sets. Collectively, these recommendations have significant potential for improving satellite sensor calibration in a focused manner that can directly catalyze efforts to develop data that are closer to being seamlessly interoperable.

calibration; geometric; radiometric; Landsat; Sent

An Inter-Comparison Exercise of Sentinel-2 Radiometric Validations Assessed by Independent Expert Groups

Copernicus is the European Union's Earth Observation and Monitoring programme, delivering free access to operational and historical environmental data to support applications in a wide range of societal benefit areas. To allow meaningful long-term environmental monitoring and robust decision-making, it is essential to ensure that satellite-retrieved products are of high quality and consistency. This paper describes the outputs of an international workshop on the radiometric calibration validation of the Copernicus Sentinel-2A and Sentinel-2B Multi-Spectral Instrument. A wide range of vicarious methodologies have been applied independently and then compared per type of target. All methods agree on the good radiometric performance of both Sentinel-2A and Sentinel-2B with respect to the mission requirements as well as on evidence of a slight bias between the two instruments. Comparisons of all these results are discussed to highlight the benefits and advantages of the methods as well as to propose potential improvements either for the methods themselves and/or for the comparison exercise.

Sentinel-2