Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas discharge lamps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Direct-current converter for gas-discharge lamps

Metal/halide and similar gas-discharge lamps are powered from low-voltage dc source using small efficient converter. Converter is useful whenever 60-cycle ac power is not available or where space and weight allocations are limited. Possible applications are offshore platforms, mobile homes, and emergency lighting. Design innovations give supply high reliability and efficiency up to 75 percent.

Lutus, P.↗

Dimmable Electronic Ballast for a Gas Discharge Lamp

Titanium dioxide (TiO2) is the most efficient photocatalyst for organic oxidative degradation. TiO2 is effective not only in aqueous solution, but also in nonaqueous solvents and in the gas phase. It is photostable, biologically and chemically inert, and non-toxic. Low-energy UV light (approximately 375 nm, UV-A) can be used to photoactivate TiO2. TiO2 photocatalysis has been used to mineralize most types of organic compounds. Also, TiO2 photocatalysis has been effectively used in sterilization. This effectiveness has been demonstrated by its aggressive destruction of microorganisms, and aggressive oxidation effects of toxins. It also has been used for the oxidation of carbon monoxide to carbon dioxide, and ammonia to nitrogen. Despite having many attractive features, advanced photocatalytic oxidation processes have not been effectively used for air cleaning. One of the limitations of the traditional photocatalytic systems is the ballast that powers (lights) the bulbs. Almost all commercial off-the-shelf (COTS) ballasts are not dimmable and do not contain safety features. COTS ballasts light the UV lamp as bright as the bulb can be lit, and this results in shorter bulb lifetime and maximal power consumption. COTS magnetic ballasts are bulky, heavy, and inefficient. Several iterations of dimmable electronic ballasts have been developed. Some manifestations have safety features such as broken-bulb or over-temperature warnings, replace-bulb alert, logbulb operational hours, etc. Several electronic ballast boards capable of independently lighting and controlling (dimming) four fluorescent (UV light) bulbs were designed, fabricated, and tested. Because of the variation in the market bulb parameters, the ballast boards were designed with a very broad range output. The ballast boards can measure and control the current (power) for each channel.

Raducanu, Marius↗

Commerical Transition to LEDs: A Pathway to High-Value Products

The use of light-emitting diodes (LEDs) to support plant growth is a radical departure from use of gas-discharge lamps, which were developed in mid-19th and widely adopted by the industry during the 20th century. Initial investigation by the National Aeronautics and Space Administration (NASA) in the late 1980s on the use of LEDs to grow plant in space is resulting in an industry-wide transition from gas discharge to solid-state lighting systems. This global transformation is given urgency by national policies to reduce energy consumption and being facilitated by ready access to information on LEDs. The combination of research, government policy, and information technology has resulted in an exponential increase in research into the use and application of LED technology in horticulture. Commercial horticulture has identified the opportunities provided by LEDs to optimize light spectra to promote growth, regulate morphology, increase nutrient content, and reduce operating costs. LED-light technology is enabling the development of innovative lighting systems, and is being incorporated into large-scale plant factories for the production of edible, ornamental, and medicinal plants. An overview of prevalence of readily accessible information on LEDs and implications for future adoption in horticulture is discussed.

Commerical↗

Visible and near-ultraviolet spectra of low-pressure rare-gas microwave discharges

The spectral emission characteristics of three commercial low pressure rare gas discharge lamps wire obtained in the near ultraviolet and visible wavelength range. All three lamps show a definite continuum over the entire wavelength range from 0.185 to 0.6 micrometers. Considerable line emission is superimposed on much of the continuum for wavelengths greater than 0.35 micrometers. These sources were used to make transmittance measurements on quartz samples in the near ultraviolet wavelength range.

Campbell, J. P.↗

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Laser induced asymmetry and inhomogeneous broadening of the microwave lineshape of a gas cell atomic frequency standard

The possibility of replacing the RF discharge lamp in a rubidium gas cell clock with a single mode laser diode is addressed. Since the short term stability of the rubidium frequency standard is limited by the shot noise of the photodetector, an increased signal-to-noise ratio due to more efficient laser diode optical pumping might improve the short term performance. Because the emission wavelength of the laser diode can be tuned, improved long term performance could be gained through the control of the light shift effect. However, due to the nature of the gas cell frequency standard, various physical phenomena are strongly coupled in their effect on the frequency output, and thus careful consideration must be given to any change in one parameter because of its interrelation with other parameters. Some investigations concerning the coupled effect of the optical and microwave fields in the rubidium atomic clock are reported. It is shown that this type of coupling is an important consideration for any attempt to incorporate a laser diode into a gas cell clock.

Camparo, J. C.↗

Wavelengths, f-Values, and Cross Sections in the UV Spectra of Astrophysical, Atoms, Ions, and Molecules

Data analysis for Fe III was completed in 2004. The new spectra give wavelengths and some energy levels for Fe III that are at least an order of magnitude more accurate than values in the literature. However, the data set is missing - because they are outside the wavelength range that we can study at Imperial College or with ancillary FT spectroscopy measurements at NIST - important transitions that would allow all energy levels to be determined with improved accuracy. We are assessing collaborations at other labs. We have made test runs with a number of cathodes (pure metals and alloys) in the Penning discharge source and selected four iron group (3d) elements, Cr, Mn, Co, and Ni, for further measurements. Cathodes of pure Cr and Co and an alloy of Ni were found to be best. Mn has not nm stably yet, and other cathode geometries or alloys may need to be assessed. Optimum Penning discharge (PD) lamp conditions (buffer gas, gas pressure, and current/voltage) were established for Co, and investigations are underway for Cr and Ni. Definitive measurements for Co await purchase of new mirrors and photomultiplier tubes that will improve signal to noise ratio. Our plan for the next year is to continue evaluating cathodes and operating conditions through March 05, and then to begin definitive measurements. The UV wavelength measurements made at Imperial College with the unique UV FT spectrometer will be complemented by visible and near IR range measurements at NIST in June and/or July. Approximately one year from now, we intend to visit Lund University to collaborate on lifetime measurements that will allow our branching ration data to be used to determine f-values.

Raymond, John C.↗

Investigations of laser pumped gas cell atomic frequency standard

The performance characteristics of a rubidium gas cell atomic frequency standard might be improved by replacing the standard rubidium discharge lamp with a single mode laser diode. Aspects of the laser pumped gas cell atomic clock studied include effects due to laser intensity, laser detuning, and the choice of the particular atomic absorption line. Results indicate that the performance of the gas cell clock may be improved by judicious choice of the operating parameters of the laser diode. The laser diode also proved to be a valuable tool in investigating the operation of the conventional gas cell clock. Results concerning linewidths, the light shift effect and the effect of isotopic spin exchange in the conventional gas cell clock are reported.

Volk, C. H.↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

Improved ultraviolet resonance lamp

Removal of the seal area from the path of the lamp discharge eliminates the gradual deterioration of lithium fluoride window surfaces from condensation of products formed by interaction of a resonant rare-gas discharge with window sealing materials. The discharge is confined to the inner tube.

Bass, A. M.↗

Photo-Induced Deuterium Enrichment in Residues Produced from the UV Irradiation of Pyrimidine in H2O and H2O+NH3 Ices

Organic compounds found in meteorites often show isotopic signatures of their interstellar/protosolar heritage as enrichments in D and 15N. Meteoritic organics found to be enriched in D include amino acids, hydroxy and dicarboxylic acids, as well as polycyclic aromatic hydrocarbons (PAHs). Processes that can produce isotopic enrichments in presolar/protosolar materials include gas-phase ion-molecule reactions, gas-grain surface reactions, and unimolecular photo-dissociation reactions involving PAHs. Because many molecules in interstellar clouds are enriched in D, the presence of D anomalies in meteorites is thought to originate from preserved or slightly altered interstellar/protostellar materials. However, the link between isotopic enrichments seen in space and those in meteoritic compounds and their relationship remain unclear. In this work, we present results of hydrogen isotopic fractionation for compounds in organic residues produced from the UV irradiation using an H2- discharge UV lamp of H2O:pyrimidine = 20:1 and H2O:NH3:pyrimidine = 20:2:1 ice mixtures at low temperature (is less than 20 K). After irradiation, the resulting residues are dissolved in H2O and analyzed with gas chromatography-mass spectrometry coupled with isotope ratio mass spectrometry (GC-MS/IRMS) [1], following a protocol similar to that used for previous analyses of comparable samples [2,3]. We used this technique to measure compound-specific D/H isotopic ratios for the initial pyrimidine and for two photo-products present in the residues, namely, 2,2'-bipyrimidine and an unidentified bipyrimidine isomer [2-4]. Measuring D enrichments in bipyrimidines has the advantage that the H atoms on these molecules are not easily exchangeable with other compounds, in particular the H2O and NH3 present in the ices or the solvents used to extract the samples for GC-MS/IRMS measurements. The δD value for the initial pyrimidine, measured with a high-temperature conversion elemental analyzer connected to the IRMS, was found to be -30% per mille. Preliminary measurements made on a residue produced from the UV irradiation of an H2O:NH3:pyrimidine = 20:2:1 ice mixture indicate δD values of +118% per mille for 2,2'- bipyrimidine and +92% per mille for the other bipyrimidine isomer, and therefore show a significant D enrichment during the photo-processing and warm-up that lead to their formation [5]. New measurements are currently being performed on a number of residues produced from simpler H2O:pyrimidine = 20:1 ice mixtures under different experimental conditions and will be presented here.

Laboratory Astrochemistry↗

High-power ultraviolet (UV) and vacuum ultraviolet (VUV) lamps with micro-cavity plasma arrays

A plasma lamp includes plates that are approximately parallel, with at least one array of microcavities formed in a surface of at least one plate. When desirable, the plates are separated a fixed distance by spacers with at least one spacer being placed near the plate's edge to form a hermetic seal therewith. A gas makes contact with the microcavity array. Electrodes capable of delivering a time-varying voltage are located on the surface of each plate. At least one electrode is located on an exterior surface of at least one interior plate. Optionally, protective windows may be placed over the electrodes. The application of the time-varying voltage interacts with the gas to form a glow discharge plasma in the microcavities and the fixed volume between the plates (when present). The glow discharge plasma efficiently and uniformly emits UV/VUV radiation over the entire surface of the lamp.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-power ultraviolet (UV) and vacuum ultraviolet (VUV) lamps with micro-cavity plasma arrays

A product having at least one plasma lamp that includes plates that are approximately parallel, with at least one array of microcavities formed in a surface of at least one plate. When desirable, the plates are separated a fixed distance by spacers with at least one spacer being placed near the plate's edge to form a hermetic seal therewith. A gas makes contact with the microcavity array. Electrodes capable of delivering a time-varying voltage are located such that the application of the time-varying voltage interacts with the gas to form a glow discharge plasma in the microcavities and the fixed volume between the plates. The glow discharge plasma efficiently and uniformly emits radiation that is predominantly in the UV/VUV spectral range with at least a portion of the radiation being emitted from the plasma lamp.

Park, Sung-Jin↗