Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gamma irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gamma Irradiation Facility

Gamma irradiation is a process that uses Cobalt60 radionuclide produced artificially in nuclear reactors to irradiate a variety of items using gamma radiation. A key characteristic of gamma irradiation is its high penetration capability and the fact that it can modify physical, chemical, and biological properties of the irradiated materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rapid Sample Insertion/Extraction Systems for Gamma Irradiation

The Rapid Sample Insertion/Extraction System for Gamma Irradiation, otherwise known as the "rabbit" system, was a four-week long project which included many different aspects; from coding an Arduino to building PVC piping to 3-D printing the "rabbit" capsules. The "rabbit" system is a system of PVC piping that allows a quick and efficient transfer of materials into/out of one of the irradiation chambers in the Gamma Irradiation Facility (GIF) with the use of a 3-D printed "rabbit." This "rabbit" encapsulates material to be irradiated and carries it from a position outside of the irradiation chamber to the basket inside of the chamber. The main purpose of this system is to save time and provide more exact data without any delays that normally occur when a person has to enter the chamber, retrieve data, and then analyze the data. This system should take measurements and retrieve the data instantaneously. The way in which the "rabbit" is sent through the PVC piping is with an advanced bi-directional, high-throughput pneumatic system, or a shop vacuum cleaner. When the vacuum is set to blow or suck then the "rabbit" will be pulled through the PVC piping to its intended destination and will hit sensors along the sides of the tubing when it reaches the end of the piping. These sensors tell the Arduino that the "rabbit" is finished moving throughout the tubing and stops a timer. Another timer is used to see how long the "rabbit" is being irradiated so when the "rabbit" reaches the sensors in the basket in the irradiation chamber another timer is started and it ends when the sensors no longer detect the "rabbit," which means that it has begun its journey back to the starting point.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Response of GaN-Based Semiconductor Devices to Ion and Gamma Irradiation

GaN has electronic properties that make it an excellent material for the next generation of power electronics; however, its radiation hardening still needs further understanding before it is used in radiation environments. In this work we explored the response of commercial InGaN LEDs to two different radiation environments: ion and gamma irradiations. For ion irradiations we performed two types of irradiations at the Ion Beam Lab (IBL) at Sandia National Laboratories (SNL): high energy and end of range (EOR) irradiations. For gamma irradiations we fielded devices at the gamma irradiation facility (GIF) at SNL. The response of the LEDs to radiation was investigated by IV, light output and light output vs frequency measurements. We found that dose levels up to 500 krads do not degrade the electrical properties of the devices and that devices exposed to ion irradiations exhibit a linear and non- linear dependence with fluence for two different ranges of fluence levels. We also performed current injection annealing studies to explore the annealing properties of InGaN LEDs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance assessment after long-term irradiation of ATLAS Micromegas detectors using 120 GeV muons at the Gamma Irradiation Facility at CERN

The ATLAS muon spectrometer will face an increased particle rate as a result of the increased instantaneous luminosity expected during the High-Luminosity LHC (HL-LHC) upgrade. The HL-LHC will provide a luminosity of $\mathscr{L}$ = 7.5 × 10 34 cm −2 s −1 and 3000 fb −1 of integrated luminosity in 10 years, about 9 times more data of the ones so far collected by the ATLAS experiment. Micromegas chambers are used in the New Small Wheel(s), the first forward muon spectrometer station, to provide tracking and triggering at the intense particle rates expected. The detectors are operated with a ternary gas mixture composed of Ar + 5%CO 2 + 2%iC 4 H 10 , providing good high voltage stability and a large pulse height, important for inclined track reconstruction of particles crossing the detector. To ensure the long-term stable operation of the detector during the whole HL-LHC period, and due to the hydrocarbon content in the mixture, an extensive aging campaign has been ongoing since 2021 at the CERN Gamma Irradiation Facility, where spare production chambers are long-term exposed to a 14 TBq 137 Cs 𝛾-source, accumulating so far, a charge equivalent to five years of HL-LHC operations under the highest expected background rate. This paper describes the results of the Micromegas chamber performance studies after two years of gamma irradiation and using the SPS/H4 120 GeV muon beams at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the degradation of gamma-irradiated elastomers using Raman spectroscopy

This report presents key findings from Raman spectroscopic analysis of gamma-irradiated rubber samples extracted from a laminated lead-damped rubber (LDR) seismic isolation device. The samples were exposed to gamma radiation from a 60Co source in a Foss Therapy Services gamma irradiator, reaching absorbed doses up to 1600 kGy. A distinct threshold near 400 kGy was identified, beyond which significant spectral changes were observed. Two Raman peaks - at approximately 425 cm-1 and 2440 cm-1 - were tracked as a function of dose using Gaussian fitting. The 425 cm-1 peak, attributed to sulfur–sulfur (S–S) bond stretching (resulting from vulcanization of the rubber), exhibited a dose-dependent upshift, indicating radiation-induced crosslinking within the sulfur-based polymer network. Conversely, the 2440 cm-1 peak, likely associated with vibrational modes of additives or impurities, showed a downward shift with increasing dose, suggesting chain scission and degradation of non-rubber constituents. These results provide first-of-a-kind insights into the microstructural evolution of elastomers under high-dose gamma irradiation and establish a preliminary dose threshold for significant degradation. Future work will incorporate multi-modal characterization—including Fourier Transform Infrared (FTIR) spectroscopy, scanning electrom microscopy (SEM) of the rubber surface morphology, thermogravimetric analysis (TGA) to determine changes in thermal stability, and mechanical testing—to correlate molecular-level changes with macroscopic performance of these elastomers as damping media in seismic isolation devices. These findings are expected to provide regulatory guidance and design criteria for qualifying low-damping rubber seismic isolators in advanced nuclear reactor applications.

36 - MATERIALS SCIENCE↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Properties for a Gamma–Irradiated ‘Revised’ International Simple Glass

Simplified surrogate high-level waste glasses from recent national and international testing were irradiated to gamma doses of 100 Mrad and 200 Mrad. Properties of the irradiated glass were measured for comparison to the pristine unirradiated glass. Glass transition temperatures as well as infrared and Raman spectroscopy measurements show no change in the irradiated glass. Short-term aqueous corrosion tests on the glass powders also indicate no measurable differences comparing the irradiated to pristine samples. Some corrosion differences were observed in the pristine glasses due to slight compositional changes. As expected from the observed radiation darkening of the glass, absorbance spectra of the irradiated glass with the pristine glass used as LDRD–2021–00341 LDRD External Report Summary reference indicates a broad absorbance over the range of 400 to 700 nm that is centered around 550-600 nm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gamma-irradiation of malic acid in aqueous solutions

The gamma-irradiation of malic acid in aqueous solutions was studied under initially oxygenated and oxygen-free conditions in an attempt to determine the possible interconversion of malic acid into other carboxylic acids, specifically those associated with Krebs cycle. The effect of dose on product formation of the system was investigated. Gas-liquid chromatography combined with mass spectrometry was used as the principal means of identification of the nonvolatile products. Thin layer chromatography and direct probe mass spectroscopy were also employed. The findings show that a variety of carboxylic acids are formed, with malonic and succinic acids in greatest abundance. These products have all been identified as being formed in the gamma-irradiation of acetic acid, suggesting a common intermediary. Since these molecules fit into a metabolic cycle, it is strongly suggestive that prebiotic pathways provided the basis for biological systems.

Negron-Mendoza, A.↗

Response of thyroid follicular cells to gamma irradiation compared to proton irradiation. I. Initial characterization of DNA damage, micronucleus formation, apoptosis, cell survival, and cell cycle phase redistribution

The RBE of protons has been assumed to be equivalent to that of photons. The objective of this study was to determine whether radiation-induced DNA and chromosome damage, apoptosis, cell killing and cell cycling in organized epithelial cells was influenced by radiation quality. Thyroid-stimulating hormone-dependent Fischer rat thyroid cells, established as follicles, were exposed to gamma rays or proton beams delivered acutely over a range of physical doses. Gamma-irradiated cells were able to repair DNA damage relatively rapidly so that by 1 h postirradiation they had approximately 20% fewer exposed 3' ends than their counterparts that had been irradiated with proton beams. The persistence of free ends of DNA in the samples irradiated with the proton beam implies that either more initial breaks or a quantitatively different type of damage had occurred. These results were further supported by an increased frequency of chromosomal damage as measured by the presence of micronuclei. Proton-beam irradiation induced micronuclei at a rate of 2.4% per gray, which at 12 Gy translated to 40% more micronuclei than in comparable gamma-irradiated cultures. The higher rate of micronucleus formation and the presence of larger micronuclei in proton-irradiated cells was further evidence that a qualitatively more severe class of damage had been induced than was induced by gamma rays. Differences in the type of damage produced were detected in the apoptosis assay, wherein a significant lag in the induction of apoptosis occurred after gamma irradiation that did not occur with protons. The more immediate expression of apoptotic cells in the cultures irradiated with the proton beam suggests that the damage inflicted was more severe. Alternatively, the cell cycle checkpoint mechanisms required for recovery from such damage might not have been invoked. Differences based on radiation quality were also evident in the alpha components of cell survival curves (0.05 Gy(-1) for gamma rays, 0.12 Gy(-1) for protons), which suggests that the higher level of survival of gamma-irradiated cells could be attributed to the persistence of nonlethally irradiated thyrocytes and/or the capacity to repair damage more effectively than cells exposed to equal physical doses of protons. The final assessment in this study was radiation-induced cell cycle phase redistribution. Gamma rays and protons produced a similar dose-dependent redistribution toward a predominantly G(2)-phase population. From our cumulative results, it seems likely that a majority of the proton-irradiated cells would not continue to divide. In conclusion, these findings suggest that there are quantitative and qualitative differences in the biological effects of proton beams and gamma rays. These differences could be due to structured energy deposition from the tracks of primary protons and the associated high-LET secondary particles produced in the targets. The results suggest that a simple dose-equivalent approach to dosimetry may be inadequate to compare the biological responses of cells to photons and protons.

NASA Discipline Radiation Health↗

Analysis of Chromosomal Aberrations after Low and High Dose Rate Gamma Irradiation in ATM or NBS Suppressed Human Fibroblast Cells

A detailed understanding of the biological effects of heavy nuclei is needed for space radiation protection and for cancer therapy. High-LET radiation produces more complex DNA lesions that may be non-repairable or that may require additional processing steps compared to endogenous DSBs, increasing the possibility of misrepair. Interplay between radiation sensitivity, dose, and radiation quality has not been studied extensively. Previously we studied chromosome aberrations induced by low- and high- LET radiation in several cell lines deficient in ATM (ataxia telangactasia mutated; product of the gene that is mutated in ataxia telangiectasia patients) or NBS (nibrin; product of the gene mutated in the Nijmegen breakage syndrome), and gliomablastoma cells that are proficient or lacking in DNA-dependent protein kinase (DNA-PK) activity. We found that the yields of both simple and complex chromosomal aberrations were significantly increased in the DSB repair defective cells compared to normal cells. The increased aberrations observed for the ATM and NBS defective lines was due to a significantly larger quadratic dose-response term compared to normal fibroblasts for both simple and complex aberrations, while the linear dose-response term was significantly higher in NBS cells only for simple exchanges. These results point to the importance of the functions of ATM and NBS in chromatin modifications that function to facilitate correct DSB repair and minimize aberration formation. To further understand the sensitivity differences that were observed in ATM and NBS deficient cells, in this study, chromosomal aberration analysis was performed in normal lung fibroblast cells treated with KU-55933, a specific ATM kinase inhibitor, or Mirin, an MRN complex inhibitor involved in activation of ATM. We are also testing siRNA knockdown of these proteins. Normal and ATM or NBS suppressed cells were irradiated with gamma-rays and chromosomes were collected with a premature chromosome condensation (PCC) technique at the first mitosis post-irradiation. Chromosomes were analyzed using a multicolor fluorescence in-situ hybridization (mFISH) chromosome painting method. Preliminary analysis showed that chromosomal exchanges were increased in the cells treated with the specific ATM inhibitor. Possible cytogenetic signatures of acute and low dose-rate gamma irradiation in ATM or Nibrin deficient and suppressed cells will be discussed.

Hada, M.↗