Cold sprayed refractory metals for chrome reduction in gun barrel liners
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
There has been increasing demand to understand the stress-strain response as well as damage and failure mechanisms of materials under impact loading condition. Dynamic tensile characterization has been an efficient approach to acquire satisfactory information of mechanical properties including damage and failure of the materials under investigation. However, in order to obtain valid experimental data, reliable tensile experimental techniques at high strain rates are required. This includes not only precise experimental apparatus but also reliable experimental procedures and comprehensive data interpretation. Kolsky bar, originally developed by Kolsky in 1949 [1] for high-rate compressive characterization of materials, has been extended for dynamic tensile testing since 1960 [2]. In comparison to Kolsky compression bar, the experimental design of Kolsky tension bar has been much more diversified, particularly in producing high speed tensile pulses in the bars. Moreover, instead of directly sandwiching the cylindrical specimen between the bars in Kolsky bar compression bar experiments, the specimen must be firmly attached to the bar ends in Kolsky tensile bar experiments. A common method is to thread a dumbbell specimen into the ends of the incident and transmission bars. The relatively complicated striking and specimen gripping systems in Kolsky tension bar techniques often lead to disturbance in stress wave propagation in the bars, requiring appropriate interpretation of experimental data. In this study, we employed a modified Kolsky tension bar, newly developed at Sandia National Laboratories, Livermore, CA, to explore the dynamic tensile response of a 4330-V steel. The design of the new Kolsky tension bar has been presented at 2010 SEM Annual Conference [3]. Figures 1 and 2 show the actual photograph and schematic of the Kolsky tension bar, respectively. As shown in Fig. 2, the gun barrel is directly connected to the incident bar with a coupler. The cylindrical striker set inside the gun barrel is launched to impact on the end cap that is threaded into the open end of the gun barrel, producing a tension on the gun barrel and the incident bar.
There has been increasing demand to understand the stress-strain response as well as damage and failure mechanisms of materials under impact loading condition. Dynamic tensile characterization has been an efficient approach to acquire satisfactory information of mechanical properties including damage and failure of the materials under investigation. However, in order to obtain valid experimental data, reliable tensile experimental techniques at high strain rates are required. This includes not only precise experimental apparatus but also reliable experimental procedures and comprehensive data interpretation. Kolsky bar, originally developed by Kolsky in 1949 [1] for high-rate compressive characterization of materials, has been extended for dynamic tensile testing since 1960 [2]. In comparison to Kolsky compression bar, the experimental design of Kolsky tension bar has been much more diversified, particularly in producing high speed tensile pulses in the bars. Moreover, instead of directly sandwiching the cylindrical specimen between the bars in Kolsky bar compression bar experiments, the specimen must be firmly attached to the bar ends in Kolsky tensile bar experiments. A common method is to thread a dumbbell specimen into the ends of the incident and transmission bars. The relatively complicated striking and specimen gripping systems in Kolsky tension bar techniques often lead to disturbance in stress wave propagation in the bars, requiring appropriate interpretation of experimental data. In this study, we employed a modified Kolsky tension bar, newly developed at Sandia National Laboratories, Livermore, CA, to explore the dynamic tensile response of a 4330-V steel. The design of the new Kolsky tension bar has been presented at 2010 SEM Annual Conference [3]. Figures 1 and 2 show the actual photograph and schematic of the Kolsky tension bar, respectively. As shown in Fig. 2, the gun barrel is directly connected to the incident bar with a coupler. The cylindrical striker set inside the gun barrel is launched to impact on the end cap that is threaded into the open end of the gun barrel, producing a tension on the gun barrel and the incident bar.
Investigation of damage and failure of materials under impact loading relies on reliable dynamic tensile experiments. A precise Kolsky tension bar is highly desirable. Based on the template of the Kolsky compression bar that we recently developed and presented at 2009 SEM conference, a new Kolsky tension bar apparatus was completed at Sandia National Laboratories, California. It is secured to the same optical table. Linear bearings with interior Frelon coating were employed to support the whole tension bar system including the bars and gun barrel. The same laser based alignment system was used to efficiently facilitate highly precise alignment of the bar system. However, the gun part was completely re-designed. One end of the gun barrel, as a part of loading device, was directly jointed to the bar system. A solid cylindrical striker is launched inside the gun barrel and then impacts on a flange attached to the other end of the gun barrel to facilitate a sudden tensile loading on the whole system. This design improves the quality of impact to easily produce a perfect stress wave and is convenient to utilize pulse shaping technique. A calibration and dynamic characterization of an aluminum specimen are presented.
Here we present a unique approach to plate impact experiments for characterization of dynamic material behavior under extreme conditions, i.e., ultra-high strain-rates (~10 6 /s) and test temperatures up to 1000 °C. Strategic modifications are made to the existing singlestage gas-gun facility at CWRU to enable this approach. These include an extension of the gun barrel at the breech end of the gas-gun, which now incorporates a precision machined steel housing that carries a vertical heater well to accommodate an 800 W resistance coil heater with axial and rotational degrees of freedom. This custom designed heater assembly enables specimens placed on the flyer plate carried by the sabot to be heated uniformly across the diameter in a 100 mTorr vacuum prior to impact at the breech end of the gun barrel. A new sabot design is utilized to minimize heat transfer from the heated flyer plate to the sabot body. Using this modified gas-gun facility, the dynamic strength of pre-heated commercial purity polycrystalline aluminum samples is investigated at the onset of plastic flow in response to weak normal shock compression at test temperatures ranging from room to near melt point of aluminum. Lastly, the dynamic strength of aluminum samples, as inferred from the measured normal particle velocity history at the free (rear) surface of the target plate, show progressive weakening with increasing specimen temperatures in the temperature range 23–643 °C; at higher test temperatures, however, the rate of softening in dynamic strength is observed to weaken and even reverse as the sample temperatures approach the melt point of aluminum (test temperature ~643 °C).
A sabot assembly includes a projectile and a housing dimensioned and configured for receiving the projectile. An air pressure cavity having a cavity diameter is disposed between a front end and a rear end of the housing. Air intake nozzles are in fluid communication with the air pressure cavity and each has a nozzle diameter less than the cavity diameter. In operation, air flows through the plurality of air intake nozzles and into the air pressure cavity upon firing of the projectile from a gun barrel to pressurize the air pressure cavity for assisting in separation of the housing from the projectile upon the sabot assembly exiting the gun barrel.
Disruptions are sudden unplanned terminations of tokamak plasmas that can lead to high thermal loads and runaway electrons (RE). Unmitigated disruptions in ITER are predicted to dissipate hundreds of MJ of thermal energy and generate multi-MeV runaway electrons. This intense heat and energetic particle beams can cause localized melting of the plasma facing components. Reliable and fast acting disruption mitigation (DM) techniques are therefore a critical requirement for ITER to safeguard the machine from damage. The proven method for DM centers on injecting a large quantity of impurity particles into the plasma to quickly increase density and radiate the thermal energy to mitigate thermal effects. Additionally, if the particle injection can achieve a critical density, it can create collisional drag which suppresses the formation of REs. The particle injection methods attempted have been shell pellet injection, massive gas injection, and shattered pellet injection (SPI). The SPI technique has been successfully used on DIII-D [1] to study thermal mitigation using a single-barrel SPI system that can more efficiently reach the critical density required for successful disruption mitigation than the other injection approaches. Recently, a new three-barrel second SPI (SPI-II) system has been developed for use on DIII-D to study injection effects from multiple toroidal locations and pellet timing. The SPI-II system is a liquid helium cooled pipe gun that has two 7 mm and one 8.5 mm pellet sizes. The pellet sizes are determined by the inner diameter of the pipe gun barrels which can easily be changed for different pellet sizes. The three pellets can be formed and fired individually or simultaneously. The SPI-II has provisions for making and firing pure species pellets with deuterium, neon, or argon and also deuterium layered pellets with a core of neon. The pellets are fired into a bent tube near the plasma edge which shatters them from the impact. This paper will describe the design and commissioning of the SPI-II system. Measured pellet speeds and shattered pellet fragment sizes will be reported.
A new pellet injection system for the TJ-II stellarator has been developed/constructed as part of a collaboration between the Oak Ridge National Laboratory (ORNL) and the Centro de Investigaciones Energ ticas, Medioambientales y Tecnol gicas (CIEMAT). ORNL is providing most of the injector hardware and instrumentation, the pellet diagnostics, and the pellet transport tubes; CIEMAT is responsible for the injector stand/interface to the stellarator, cryogenic refrigerator, vacuum pumps/ballast volumes, gas manifolds, remote operations, plasma diagnostics, and data acquisition. The pellet injector design is an upgraded version of that used for the ORNL injector installed on the Madison Symmetric Torus (MST). It is a four-barrel system equipped with a cryogenic refrigerator for in situ hydrogen pellet formation and a combined mechanical punch/propellant valve system for pellet acceleration (speeds ~100 to 1000 m/s). On TJ-II, it will be used as an active diagnostic and for fueling. To accommodate the plasma experiments planned for TJ-II, pellet sizes significantly smaller than those typically used for the MST application are required. The system will initially be equipped with four different pellet sizes, with the gun barrel bores ranging between ~0.5 to 1.0 mm. The new system is almost complete and is described briefly here, highlighting the new features added since the original MST injector was constructed. Also, the future installation on TJ-II is reviewed.
Shattered pellet injection (SPI) has been selected as the baseline technology for the disruption mitigation (DM) system for ITER. Typical SPI utilizes cryogenic cooling to desublimate low pressure (<100 mbar) gases onto a cold zone within a pipe gun barrel, forming a cylindrical pellet. Pellets are dislodged from the barrel and accelerated using either a gas driven mechanical punch or high-pressure light-gas delivered by a fast-opening valve. SPI technology developed at Oak Ridge National Laboratory is currently deployed and operational on DIII-D, JET, and KSTAR. These SPI systems are used in experiments for physics scaling to ITER thermal mitigation and runaway electron dissipation/avoidance. The pellet sizes used for these machines are in the range of 4 to 12.5 mm in diameter with length to diameter ratios (L/D) of ~1.5. The current plan for ITER SPI is to utilize pellets that are 28.5 mm in diameter with an L/D of ~2. Furthermore, the large pellet sizes, high steady-state magnetic fields, and limitations of operating in a radiation environment render much of the current technology unusable. In addition to technology improvements, a deeper understanding of pellet material properties, formation, and release is being developed for implementation in future SPI designs, specifically ITER.
Pressure-shear experiments were performed on granular tungsten carbide and sand using a newly-refurbished slotted barrel gun. The sample is a thin layer of the granular material sandwiched between driver and anvil plates that remain elastic. Because of the obliquity, impact generates both a longitudinal wave, which compresses the sample, and a shear wave that probes the strength of the sample. Laser velocity interferometry is employed to measure the velocity history of the free surface of the anvil. Since the driver and anvil remain elastic, analysis of the results is, in principal, straightforward. Experiments were performed at pressures up to nearly 2 GPa using titanium plates and at higher pressure using zirconium plates. Those done with the titanium plates produced values of shear stress of 0.1-0.2 GPa, with the value increasing with pressure. On the other hand, those experiments conducted with zirconia anvils display results that may be related to slipping at an interface and shear stresses mostly at 0.1 GPa or less. Recovered samples display much greater particle fracture than is observed in planar loading, suggesting that shearing is a very effective mechanism for comminution of the grains.
US Special Operations Command (USSOCOM) was seeking a technological leap in small firearms weapon suppressor technology, because anticipated enemy capabilities are requiring the operators to have smaller detection cross sections to ensure the safe execution of missions. Suppressors have been developed almost exclusively through trial-and-error methods since the time of the original design by Hiram Maxim over one hundred years ago. Consequently USSOCOM deemed it prudent to perform a physicsbased study of weapon suppression to understand performance limits and possibly identify breakthrough technologies. Lawrence Livermore National Laboratory’s (LLNL’s) high performance production level computational tool called ALE3D (Arbitrary Lagrangian-Eulerian 3D and 2D) has unique physics models and numerical algorithms for modeling suppressor dynamics. The flexible and extendable code framework supports fully integrated hydrodynamics, heat transfer, solid and fluid dynamics, and chemistry that can be applied to simulating propellant-driven motion of a bullet down a gun barrel, the transfer of heat from the burning propellant to the barrel and suppressor, the chemistry of muzzle flash, and the shock/acoustic/optical signatures in the near-field. LLNL’s originally anticipated role was to augment ALE3D for this task, by developing the software and analysis methodologies specific to the simulation of blast and muzzle flash phenomena. It was believed that insights provided by our ALE3D simulations in tandem with a coordinated experimental component by our other team members from Oak Ridge National Laboratory (ORNL) and the U. S. Army Armament, Research, Development and Engineering Center (ARDEC), would have excellent prospects of yielding useful suppressor design improvements that could be transitioned to industry and utilized by US Special Operations Command. The three year effort has come to fruition with the development of revolutionary suppressor designs that far outperform any previous or current design by anyone outside this multi-lab team.
A special single-shot pellet injection system that produces and accelerates large cryogenic pellets (~16 mm diameter and composed of D2 or Ne) to relatively high speeds (>300 and 600 m/s, respectively) was previously developed at the Oak Ridge National Laboratory. Subsequently, a similar system was installed on DIII-D and used successfully in disruption mitigation experiments. To circumvent some operational issues with injecting the large Ne pellets, a technique has been developed in which a relatively thin layer (0.1 to 1.0 mm) of D2 is frozen on the inner wall of the pipe-gun barrel, followed by filling the core with solid Ne. The technique and the initial laboratory tests are described, as well as the implementation and operational issues for fusion experiments.
Motivation of this project is: (1) Build a furnace as a cross section of a gun barrel capable of temperatures up to 600 Celsius; (2) To examine the influence of temperature, texture, and extrusion velocity in Tantalum; (3) Constrain parameters to improve and assist in constitutive model development using high speed imaging & PDV (in-situ); (4) Understanding microstructural development in materials using the dynamic extrusion technique; and (5) Use as a validation test for developing fracture models important to industry, the DoD, and the DOE.
A non-spinning projectile that is self-guided to a laser designated target and is configured to be fired from a small caliber smooth bore gun barrel has an optical sensor mounted in the nose of the projectile, a counterbalancing mass portion near the fore end of the projectile and a hollow tapered body mounted aft of the counterbalancing mass. Stabilizing strakes are mounted to and extend outward from the tapered body with control fins located at the aft end of the strakes. Guidance and control electronics and electromagnetic actuators for operating the control fins are located within the tapered body section. Output from the optical sensor is processed by the guidance and control electronics to produce command signals for the electromagnetic actuators. A guidance control algorithm incorporating non-proportional, "bang-bang" control is used to steer the projectile to the target.
The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing technique commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.
A multiple cathode system has been designed to provide the high average current polarized electron bunches for the future electron-ion collider eRHIC [1]. One of the key research topics in this design is the technique to generate a combined dipole and quadrupole rotating field at high frequency (700 kHz). This type of field is necessary for combining bunches from different cathodes to the same axis with minimum emittance growth. Our simulations and the prototype test results to achieve this will be presented. The future eRHIC project, next upgrade of EHIC, will be the first electron-heavy ion collider in the world. For polarized-electron and polarized proton collisions, it requires a polarized electron source with high average current ({approx}50 mA), short bunch ({approx}3 mm), emittance of about 20 {micro}m and energy spread of {approx}1% at 10 MeV. The state-of-art polarized electron cathode can generate average current of about more than 1 mA, but much less than 50 mA. The current is limited by the quantum efficiency, lifetime, space charge and ultra-high vacuum requirement of the polarized cathode. A possible approach to achieve the 50 mA beam is to employ multiple cathodes, such as 20 cathodes, and combine the multiple bunched beams from cathodes to the same axis. We name it as 'Gatling gun' because its operations bear similarity to a multi-barrel Gatling gun. The electron spin direction is not affected by electric field but will follow to the direction of the magnetic bending. This requires that, to preserve the spin polarization from cathode, the fixed bending field after the solenoid and the rotating bending field in combiner must be either a pair of electric bendings or a pair of magnetic bendings. We choose the scheme with a pair of magnetic bendings because it is much easier than the scheme with a pair of electric bendings at our 200 keV electron energy level.
Means of reducing the transverse load on a projectile accelerating in the barrel of a light-gas gun are considered.
MicroSight is an innovative gunsight technology that allows a marksman's eye to focus on both the front gunsight and the intended target. The MicroSight improves both firearm safety and performance by imaging two objects at different focal distances. The MicroSight was developed at Idaho National Laboratory, and has been licensed by Apollo Optical Systems. You can learn more about INL's research programs at http://www.facebook.com/idahonationallaboratory.