Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GOLD 187”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A = 187

Evaluated spectroscopic data and level schemes from radioactive decay and nuclear reaction studies are presented for {sup 187}Hf, {sup 187}Ta, {sup 187}W, {sup 187}Re, {sup 187}Os, {sup 187}Ir, {sup 187}Pt, {sup 187}Au, {sup 187}Hg, {sup 187}Tl, {sup 187}Pb, {sup 187}Bi, and {sup 187}Po. This evaluation for A = 187 supersedes the earlier one by R.B. Firestone (1991Fi02) published in Nuclear Data Sheets 62, 159 (1991) and the {sup 187}Tl evaluation by C.M. Baglin (1999Ba24) published in Nuclear Data Sheets 86, 487 (1999). Highlights of this publication are the following: This evaluation includes first identifications of {sup 187}Hf, {sup 187}Ta (1999Be63, 2000PoZY) and {sup 187}Po (2006An11) nuclides. A B(E2){up_arrow} = 0.080 12 was determined by 1967Bi10 for the 9/2+ state at 845 keV in {sup 187}Re Coulomb Excitation. Using this B(E2) value and the adopted 845{gamma} ray properties, a T{sub 1/2}=54 fs 34 can be deduced for the 845 keV level of {sup 187}Re. This T{sub 1/2} yields a large B(E2)(W.u.){approx}1.3x105 for the 263{gamma} (depopulating the same level) indicating either substantial unobserved feeding or incorrect g-ray branching intensities of this level. The decay of g.s. and isomer of {sup 187}Tl are poorly known (please see {sup 187}Tl {epsilon} decay (51 s+15.60 s)). Based on {sup 191}Po {alpha} decay studies, 2002An19 establishes a {sup 187}Pb isomeric level energy at 2(15) keV and assigns J{pi}=13/2+ for the {sup 187}Pb g.s. and J{pi}=3/2- for the isomeric state (inverse of the systematics of odd-mass Pb nuclei in this region). From {sup 187}Pb and {sup 187}Pb{sup m} mass measurements, 2005We11 determined the isomeric level energy at 33(13) keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Panning for Gold: New Emission Lines from UV–VIS Spectroscopy of Au i and Au ii

The recent detection of a neutron star merger by the LIGO collaboration has renewed interest in laboratory studies of r-process elements. Accurate modeling and interpretation of the electromagnetic transients following the mergers requires computationally expensive calculations of both the structure and opacity of all trans-iron elements. To date, the necessary atomic data to benchmark structure codes are incomplete or, in some cases, absent entirely. Within the available laboratory studies, the literature on Au i and Au ii provides incomplete reports of the emission lines and level structures. We present a new study of Au i and Au ii lines and levels by exposing a solid gold target to plasma in the Compact Toroidal Hybrid (CTH) experiment at Auburn University. A wavelength range from 187 to 800 nm was studied. In Au i, 86 lines are observed, 43 of which are unreported in the literature, and the energies of 18 $5{d}^{9}6s6p$ levels and 16 of the 18 known $5{d}^{9}6s6d$ levels are corroborated by a least-squares level energy optimization. In Au ii, 76 emission lines are observed, and 51 of the lines are unreported in the literature. For both Au i and Au ii, the new lines predominantly originate from the most energetic of the known levels, and over half of the new Au ii lines have wavelengths longer than 300 nm. For the estimated electron parameters of CTH plasmas at the gold target (ne ~ 10 12 cm -3 , T e ~ 10 eV), two-electron transitions are similar in intensity to LS-allowed one-electron transitions.

79 ASTRONOMY AND ASTROPHYSICS↗

Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator

Purpose: Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has been published. The Varian TrueBeam 2.0 accelerator includes a prototype tracking system with selectable couch or MLC compensation. This study provides a direct comparison of the two tracking types with an otherwise identical setup. Methods: Several experiments were performed to characterize the geometric and dosimetric performance of electromagnetic guided couch and MLC tracking on a TrueBeam accelerator equipped with a Millennium MLC. The tracking system latency was determined without motion prediction as the time lag between sinusoidal target motion and the compensating motion of the couch or MLC as recorded by continuous MV portal imaging. The geometric and dosimetric tracking accuracies were measured in tracking experiments with motion phantoms that reproduced four prostate and four lung tumor trajectories. The geometric tracking error in beam’s eye view was determined as the distance between an embedded gold marker and a circular MLC aperture in continuous MV images. The dosimetric tracking error was quantified as the measured 2%/2 mm gamma failure rate of a low and a high modulation VMAT plan delivered with the eight motion trajectories using a static dose distribution as reference. Results: The MLC tracking latency was approximately 146 ms for all sinusoidal period lengths while the couch tracking latency increased from 187 to 246 ms with decreasing period length due to limitations in the couch acceleration. The mean root-mean-square geometric error was 0.80 mm (couch tracking), 0.52 mm (MLC tracking), and 2.75 mm (no tracking) parallel to the MLC leaves and 0.66 mm (couch), 1.14 mm (MLC), and 2.41 mm (no tracking) perpendicular to the leaves. The motion-induced gamma failure rate was in mean 0.1% (couch tracking), 8.1% (MLC tracking), and 30.4% (no tracking) for prostate motion and 2.9% (couch), 2.4% (MLC), and 41.2% (no tracking) for lung tumor motion. The residual tracking errors were mainly caused by inadequate adaptation to fast lung tumor motion for couch tracking and to prostate motion perpendicular to the MLC leaves for MLC tracking. Conclusions: Couch and MLC tracking markedly improved the geometric and dosimetric accuracies of VMAT delivery. However, the two tracking types have different strengths and weaknesses. While couch tracking can correct perfectly for slowly moving targets such as the prostate, MLC tracking may have considerably larger dose errors for persistent target shift perpendicular to the MLC leaves. Advantages of MLC tracking include faster dynamics with better adaptation to fast moving targets, the avoidance of moving the patient, and the potential to track target rotations and deformations.

60 APPLIED LIFE SCIENCES↗

Discovery of Highly Excited Long-Lived Isomers in Neutron-Rich Hafnium and Tantalum Isotopes through Direct Mass Measurements

A study of cooled {sup 197}Au projectile-fragmentation products has been performed with a storage ring. This has enabled metastable nuclear excitations with energies up to 3 MeV, and half-lives extending to minutes or longer, to be identified in the neutron-rich nuclides {sup 183,184,186}Hf and {sup 186,187}Ta. The results support the prediction of a strongly favored isomer region near neutron number 116.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Genomic description of human clinical Aspergillus fumigatus isolates, California, 2020

Abstract Aspergillus fumigatus, an environmental mold, causes life-threatening infections. Studies on the phylogenetic structure of human clinical A. fumigatus isolates are limited. Here, we performed whole genome sequencing of 24 A. fumigatus isolates collected from 18 patients in U.S. healthcare facilities in California. Single-nucleotide polymorphism (SNP) differences between patient isolates ranged from 187 to 70 829 SNPs. For five patients with multiple isolates, we calculated the within-host diversities. Three patients had a within-host diversity that ranged from 4 to 10 SNPs and two patients ranged from 2 to 16 977 SNPs. Findings revealed highly diverse A. fumigatus strains among patients and two patterns of diversity for isolates that come from the same patient, low and extremely high diversity.

Misas, Elizabeth (ORCID:0000000162437716)↗