Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GOLD 170”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A=170☆

Nuclear structure data pertaining to all nuclei with mass number A=170 have been evaluated, and incorporated into the ENSDF data file. This evaluation supersedes the previous evaluation (Coral M. Baglin), Nuclear Data Sheets 96, 611 (2002), (cutoff date 15 August 2002) and subsequent updates of the ENSDF file for Yb to Dy (cutoff 15 April 2010), Lu (cutoff 8 October 1998), Pt (cutoff 17 February 1999) and Ta, Os (cutoff 7 April 1998). Since the previous evaluation, {sup 170}Gd has been observed and the ground state T{sub 1/2} measured. New excited states have also been observed in the neutron rich {sup 170}Dy. The ground state T{sub 1/2} of {sup 170}Tb has been determined, however, there are currently still no excited states observed in this nucleus. There remains some uncertainty in the ground state and longer-lived isomer in {sup 170}Ir which could warrent further experimental investigation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling a Hypothetical {sup 170}Tm Source for Brachytherapy Applications

Purpose: To perform absorbed dose calculations based on Monte Carlo simulations for a hypothetical {sup 170}Tm source and to investigate the influence of encapsulating material on the energy spectrum of the emitted electrons and photons. Methods: GEANT4 Monte Carlo code version 9.2 patch 2 was used to simulate the decay process of {sup 170}Tm and to calculate the absorbed dose distribution using the GEANT4 Penelope physics models. A hypothetical {sup 170}Tm source based on the Flexisource brachytherapy design with the active core set as a pure thulium cylinder (length 3.5 mm and diameter 0.6 mm) and different cylindrical source encapsulations (length 5 mm and thickness 0.125 mm) constructed of titanium, stainless-steel, gold, or platinum were simulated. The radial dose function for the line source approximation was calculated following the TG-43U1 formalism for the stainless-steel encapsulation. Results: For the titanium and stainless-steel encapsulation, 94% of the total bremsstrahlung is produced inside the core, 4.8 and 5.5% in titanium and stainless-steel capsules, respectively, and less than 1% in water. For the gold capsule, 85% is produced inside the core, 14.2% inside the gold capsule, and a negligible amount (<1%) in water. Platinum encapsulation resulted in bremsstrahlung effects similar to those with the gold encapsulation. The range of the beta particles decreases by 1.1 mm with the stainless-steel encapsulation compared to the bare source but the tissue will still receive dose from the beta particles several millimeters from the source capsule. The gold and platinum capsules not only absorb most of the electrons but also attenuate low energy photons. The mean energy of the photons escaping the core and the stainless-steel capsule is 113 keV while for the gold and platinum the mean energy is 160 keV and 165 keV, respectively. Conclusions: A {sup 170}Tm source is primarily a bremsstrahlung source, with the majority of bremsstrahlung photons being generated in the source core and experiencing little attenuation in the source encapsulation. Electrons are efficiently absorbed by the gold and platinum encapsulations. However, for the stainless-steel capsule (or other lower Z encapsulations) electrons will escape. The dose from these electrons is dominant over the photon dose in the first few millimeter but is not taken into account by current standard treatment planning systems. The total energy spectrum of photons emerging from the source depends on the encapsulation composition and results in mean photon energies well above 100 keV. This is higher than the main gamma-ray energy peak at 84 keV. Based on our results, the use of {sup 170}Tm as a brachytherapy source presents notable challenges.

07 ISOTOPE AND RADIATION SOURCES↗

Cryogenically enhanced quasi-optical resonator for megawatt pulsed millimeter-wave sources

We report the design, cryogenic optimization, and performance modeling of a compact quasi-optical ring resonator intended to compress microwaves pulses at 170 and 250 GHz to the megawatt level. By combining ultra-low-loss CVD diamond and gold-doped silicon wafers with high-RRR copper mirrors, the calculated unloaded quality factor exceeds 4.3 × 10 5 at 20 K and yields simulated gains up to $\mathscr{G}$ = 4.1 × 10 3 . Coupling the resonator with a laser-driven semiconductor switch described by an extended Vogel model shows that 1 MW, nanosecond pulses can be generated from only 445 W of microwave drive power while dissipating 272 W into the cryostat. A practical cooling architecture using two Gifford–McMahon stages (20 and 80 K) is proposed, demonstrating that high-repetition-rate (10–20 kHz) operation is feasible with commercially available cryocoolers. The results outline a clear path toward cost-effective, table-top sources for extreme-ultraviolet lithography, dynamic nuclear polarization, and fusion systems.

Panisset, Constant [Ecole Polytechnique Federale L↗

Enhanced Spatial Proteomics and Metabolomics from a Single Tissue Section Using MALDI-MSI and LCM-microPOTS Platforms

Spatially resolved mass spectrometry (MS)-based multi-omics workflows are becoming more utilized for revealing the complex biology that occurs within tissues. However, these approaches commonly require multiple independent tissue sections to analyze the metabolite and protein compositions of these samples. This poses a significant challenge in preserving cell- or region-specific molecular fidelity, as variations between tissue sections can compromise the accurate correlation of molecular data. Here, in this study, we developed workflows for comprehensive multi-omics profiling from a single tissue section (STS) using different MS modalities. We enhanced the functionality of an electrically insulated substrate by employing metal-assisted approaches that enabled both MS-based untargeted spatial metabolomics and proteomics from STS. This allowed metabolite imaging using matrix-assisted laser desorption/ionization-MS imaging (MALDI-MSI), without compromising it for subsequent proteome profiling with laser capture microdissection (LCM)-based technology. Specifically, implementing copper tape as a backing for polyethylene naphthalate (PEN) slides enabled the detection of >140 metabolites across a poplar root tissue section using MALDI-trapped ion mobility spectrometry time of flight (timsTOF)-MS. Afterwards, we detected 6,571 unique proteins from two distinct root regions by leveraging LCM technology coupled to our microdroplet based sample preparation approach. We also developed an alternative workflow utilizing gold-coated PEN substrates for imaging with MALDI-Fourier-transform ion cyclotron resonance (FTICR)-MS, which permitted the profiling of >170 metabolites and the identification of 6,542 unique proteins across a single poplar root tissue section. These results were comparable to using each assay independently without modifications. These approaches offer new opportunities for high-resolution molecular profiling of multiple omics-levels across biological tissues.

Veličković, Marija [Pacific Northwest National Lab↗

Extending quantum-mechanical benchmark accuracy to biological ligand-pocket interactions

Predicting the binding affinity of ligands to protein pockets is key in the drug design pipeline. The flexibility of ligand-pocket motifs arises from a range of attractive and repulsive electronic interactions during binding. Accurately accounting for all interactions requires robust quantum-mechanical (QM) benchmarks, which are scarce for ligand-pocket systems. Additionally, disagreement between “gold standard” Coupled Cluster (CC) and Quantum Monte Carlo (QMC) methods casts doubt on many benchmarks for larger non-covalent systems. We introduce the “QUantum Interacting Dimer” (QUID) benchmark framework containing 170 non-covalent (non-)equilibrium systems modeling chemically and structurally diverse ligand-pocket motifs. Symmetry-adapted perturbation theory shows that QUID broadly covers non-covalent binding motifs and energetic contributions. Robust binding energies are obtained using complementary CC and QMC methods, achieving agreement of 0.5 kcal/mol. The benchmark data analysis reveals that several dispersion-inclusive density functional approximations provide accurate energy predictions, though their atomic van der Waals forces differ in magnitude and orientation. Contrarily, semiempirical methods and empirical force fields require improvements in capturing non-covalent interactions (NCIs) for out-of-equilibrium geometries. The wide span of NCIs, highly accurate interaction energies, and analysis of molecular properties take QUID beyond the “gold standard” for QM benchmarks of ligand-protein systems.

Puleva, Mirela [University of Luxembourg, Luxembou↗

SU-E-I-67: X-Ray Fluorescence for Energy Response Calibration of a Photon Counting Detector: A Simulation Study

Purpose: To investigate the feasibility of energy calibration and energy response characterization of a photon counting detector using x-ray fluorescence. Methods: A comprehensive Monte Carlo simulation study was done to investigate the influence of various geometric components on the x-ray fluorescence measurement. Different materials, sizes, and detection angles were simulated using Geant4 Application for Tomographic Emission (GATE) Monte Carlo package. Simulations were conducted using 100 kVp tungsten-anode spectra with 2 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm2 in detection area. The fluorescence material was placed 300 mm away from both the x-ray source and the detector. For angular dependence measurement, the distance was decreased to 30 mm to reduce the simulation time. Compound materials, containing silver, barium, gadolinium, hafnium, and gold in cylindrical shape, were simulated. The object size varied from 5 to 100 mm in diameter. The angular dependence of fluorescence and scatter were simulated from 20° to 170° with an incremental step of 10° to optimize the fluorescence to scatter ratio. Furthermore, the angular dependence was also experimentally measured using a spectrometer (X-123CdTe, Amptek Inc., MA) to validate the simulation results. Results: The detection angle between 120° to 160° resulted in more optimal x-ray fluorescence to scatter ratio. At a detection angle of 120°, the object size did not have a significant effect on the fluorescence to scatter ratio. The experimental results of fluorescence angular dependence are in good agreement with the simulation results. The Kα and Kβ peaks of five materials could be identified. Conclusion: The simulation results show that the x-ray fluorescence procedure has the potential to be used for detector energy calibration and detector response characteristics by using the optimal system geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient black silicon photovoltaic devices with enhanced blue response

A photovoltaic (PV) device with improved blue response. The PV device includes a silicon substrate with an emitter layer on a light receiving side. The emitter layer has a low opant level such that it has sheet resistance of 90 to 170 ohm/sq. Anti-reflection in the PV device is provided solely by a nano-structured or black silicon surface on the light-receiving surface, through which the emitter is formed by diffusion. The nano structures of the black silicon are formed in a manner that does not result in gold or another high-recombination metal being left in the black silicon such as with metal-assisted etching using silver. The black silicon is further processed to widen these pores so as to provide larger nanostructures with lateral dimensions in the range of 65 to 150 nanometers so as to reduce surface area and also to etch away a highly doped portion of the emitter.

Oh, Jihun↗

Is Cu a stable electrode material in hybrid perovskite solar cells for a 30-year lifetime?

One grand challenge for long-lived perovskite solar cells is that the common electrode materials in solar cells, such as silver and aluminum or even gold, strongly react with hybrid perovskites. Here we report the evaluation of the potential of copper (Cu) as the electrode material in perovskite solar cells for long-term stability. In encapsulated devices which limit exposure to oxygen and moisture, Cu in direct contact with CH 3 NH 3 PbI 3 showed no reaction at laboratory time scales, and is predicted to be stable for almost 170 years at room temperature and over 22 years at the nominal operating cell temperature of 40 °C. No diffusion of Cu into CH 3 NH 3 PbI 3 has been observed after thermal annealing for over 100 hours at 80 °C, nor does Cu cause charge trap states in direct contact with CH 3 NH 3 PbI 3 after long-term thermal annealing or illumination. High performance devices with efficiency above 20% with Cu electrode retains 98% of the initial efficiency after 816 hours storage in ambient environment without encapsulation. Finally, the results indicate Cu is a promising low-cost electrode material for perovskite solar cells for long-term operation.

25 ENERGY STORAGE↗

An online x-ray based position validation system for prostate hypofractionated radiotherapy

Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR{sub seg}) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPR{sub trig}) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR{sub seg} of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80°–100° and 260°–280° where seeds are obscured by anatomy. This resulted in a TPR{sub trig} of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior–posterior and lateral directions, the TPR{sub trig} of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130°–170° and 310°–350° (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images. Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20° arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Iron X-ray Transmission at Temperature Near 150 eV Using the National Ignition Facility: First Measurements and Paths to Uncertainty Reduction

Discrepancies exist between theoretical and experimental opacity data for iron, at temperatures 180–195 eV and electron densities near 3 × 1022/cm3, relevant to the solar radiative-convective boundary. Another discrepancy, between theory and helioseismic measurements of the boundary’s location, would be ameliorated if the experimental opacity is correct. To address these issues, this paper details the first results from new experiments under development at the National Ignition Facility (NIF), using a different method to replicate the prior experimental conditions. In the NIF experiments, 64 laser beams indirectly heat a plastic-tamped rectangular iron-magnesium sample inside a gold cavity. Another 64 beams implode a spherical plastic shell to produce a continuum X-ray flash which backlights the hot sample. An X-ray spectrometer records the transmitted X-rays, the unattenuated X-rays passing around the sample, and the sample’s self-emission. From these data, X-ray transmission spectra are inferred, showing Mg K-shell and Fe L-shell X-ray transitions from plasma at a temperature of ~150 eV and electron density of ~8 × 1021/cm3. These conditions are similar to prior Z measurements which agree better with theory. The NIF transmission data show statistical uncertainties of 2–10%, but various systematic uncertainties must be addressed before pursuing quantitative comparisons. The paths to reduction of the largest uncertainties are discussed. Once the uncertainty is reduced, future NIF experiments will probe higher temperatures (170–200 eV) to address the ongoing disagreement between theory and Z data.

36 MATERIALS SCIENCE↗

Continuous table acquisition MRI for radiotherapy treatment planning: Distortion assessment with a new extended 3D volumetric phantom

Purpose: Accurate geometry is required for radiotherapy treatment planning (RTP). When considering the use of magnetic resonance imaging (MRI) for RTP, geometric distortions observed in the acquired images should be considered. While scanner technology and vendor supplied correction algorithms provide some correction, large distortions are still present in images, even when considering considerably smaller scan lengths than those typically acquired with CT in conventional RTP. This study investigates MRI acquisition with a moving table compared with static scans for potential geometric benefits for RTP. Methods: A full field of view (FOV) phantom (diameter 500 mm; length 513 mm) was developed for measuring geometric distortions in MR images over volumes pertinent to RTP. The phantom consisted of layers of refined plastic within which vitamin E capsules were inserted. The phantom was scanned on CT to provide the geometric gold standard and on MRI, with differences in capsule location determining the distortion. MRI images were acquired with two techniques. For the first method, standard static table acquisitions were considered. Both 2D and 3D acquisition techniques were investigated. With the second technique, images were acquired with a moving table. The same sequence was acquired with a static table and then with table speeds of 1.1 mm/s and 2 mm/s. All of the MR images acquired were registered to the CT dataset using a deformable B-spline registration with the resulting deformation fields providing the distortion information for each acquisition. Results: MR images acquired with the moving table enabled imaging of the whole phantom length while images acquired with a static table were only able to image 50%–70% of the phantom length of 513 mm. Maximum distortion values were reduced across a larger volume when imaging with a moving table. Increased table speed resulted in a larger contribution of distortion from gradient nonlinearities in the through-plane direction and an increased blurring of capsule images, resulting in an apparent capsule volume increase by up to 170% in extreme axial FOV regions. Blurring increased with table speed and in the central regions of the phantom, geometric distortion was less for static table acquisitions compared to a table speed of 2 mm/s over the same volume. Overall, the best geometric accuracy was achieved with a table speed of 1.1 mm/s. Conclusions: The phantom designed enables full FOV imaging for distortion assessment for the purposes of RTP. MRI acquisition with a moving table extends the imaging volume in the z direction with reduced distortions which could be useful particularly if considering MR-only planning. If utilizing MR images to provide additional soft tissue information to the planning CT, standard acquisition sequences over a smaller volume would avoid introducing additional blurring or distortions from the through-plane table movement.

60 APPLIED LIFE SCIENCES↗

Cryogenic thermonuclear fuel implosions on the National Ignition Facility

The first inertial confinement fusion implosion experiments with equimolar deuterium-tritium thermonuclear fuel have been performed on the National Ignition Facility. These experiments use 0.17 mg of fuel with the potential for ignition and significant fusion yield conditions. The thermonuclear fuel has been fielded as a cryogenic layer on the inside of a spherical plastic capsule that is mounted in the center of a cylindrical gold hohlraum. Heating the hohlraum with 192 laser beams for a total laser energy of 1.6 MJ produces a soft x-ray field with 300 eV temperature. The ablation pressure produced by the radiation field compresses the initially 2.2-mm diameter capsule by a factor of 30 to a spherical dense fuel shell that surrounds a central hot-spot plasma of 50 {mu}m diameter. While an extensive set of x-ray and neutron diagnostics has been applied to characterize hot spot formation from the x-ray emission and 14.1 MeV deuterium-tritium primary fusion neutrons, thermonuclear fuel assembly is studied by measuring the down-scattered neutrons with energies in the range of 10 to 12 MeV. X-ray and neutron imaging of the compressed core and fuel indicate a fuel thickness of (14 {+-} 3) {mu}m, which combined with magnetic recoil spectrometer measurements of the fuel areal density of (1 {+-} 0.09) g cm{sup -2} result in fuel densities approaching 600 g cm{sup -3}. The fuel surrounds a hot-spot plasma with average ion temperatures of (3.5 {+-} 0.1) keV that is measured with neutron time of flight spectra. The hot-spot plasma produces a total fusion neutron yield of 10{sup 15} that is measured with the magnetic recoil spectrometer and nuclear activation diagnostics that indicate a 14.1 MeV yield of (7.5{+-}0.1) Multiplication-Sign 10{sup 14} which is 70% to 75% of the total fusion yield due to the high areal density. Gamma ray measurements provide the duration of nuclear activity of (170 {+-} 30) ps. These indirect-drive implosions result in the highest areal densities and neutron yields achieved on laser facilities to date. This achievement is the result of the first hohlraum and capsule tuning experiments where the stagnation pressures have been systematically increased by more than a factor of 10 by fielding low-entropy implosions through the control of radiation symmetry, small hot electron production, and proper shock timing. The stagnation pressure is above 100 Gbars resulting in high Lawson-type confinement parameters of P{tau} Asymptotically-Equal-To 10 atm s. Comparisons with radiation-hydrodynamic simulations indicate that the pressure is within a factor of three required for reaching ignition and high yield. This will be the focus of future higher-velocity implosions that will employ additional optimizations of hohlraum, capsule and laser pulse shape conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Revisiting heavy ion collisions under the influence of strong magnetic fields

The quark-gluon plasma (QGP) phase refers to matter where quarks and gluons are believed to be deconfined and it probably takes place at temperatures of the order of 150 to 170 MeV. In large colliders around the world (RHIC/BNL, ALICE/CERN, GSI, etc), physicists are trying to convert hadronic matter at these order of temperatures into QGP by looking at non-central heavy ion collisions. Possible experiments towards this search are Au-Au collisions at RHIC/BNL and Pb-Pb collisions at SPS/CERN, where the hadron abundances and particle ratios are used in order to determine the temperature and baryonic chemical potential of the possibly present hadronic matter-QGP phase transition. The magnetic fields involved in heavy-ion collisions, although time dependent and short-lived, can reach intensities higher than the ones considered in magnetars, around 1.7 Multiplication-Sign 10{sup 19} to 10{sup 20} Gauss. In fact, the densities related to the chemical potentials obtained within the relativistic models framework developed in previous works are very low (of the order of 10{sup -3} fm{sup -3}). At these densities the nuclear interactions are indeed very small and this fact made us consider the possibility of free Fermi and Boson gases under the unfluence of strong magnetic fields. We investigate the effects of magnetic fields of the order of 10{sup 18}, 10{sup 19} and 10{sup 20} G through a {chi}{sup 2} fit to some data sets of the STAR experiment. Our results shown that a field of the order of 10{sup 19} G can produce a much better fit to the experimental data than the calculations without magnetic fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗