Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLOVEBOXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗

Evaluation of Glovebox Fires Involving Flammable Liquids and Standard Glovebox Tools (Final Report)

This research effort was commissioned to examine factors related to loss of containment due to fire within a glovebox (GB). Tests consisted of multiple trials with varying initial conditions. Com bustible levels and types were chosen to reflect realistic operation conditions (including worst-case scenarios), involving flammable liquids, GB tools, and other combustible items commonly found in GBs at Los Alamos National Labs (LANL).

42 ENGINEERING↗

Glovebox Handling of High-Consequence Materials with Super Baxter and Gesture-Based Programming - 18598

The handling of high-consequence materials is a difficult task requiring safe object manipulation while avoiding the risk of contamination or spillage. Specific operations including opening containers, segregating the wastes, and repackaging are required to be safely executed inside contained spaces such as gloveboxes. However, the workers' ability and dexterity to manipulate objects through thick protective gloves are compromised in many aspects. The fixed position of the glovebox arm ports restricts the movements of the workers' arms, which also makes it hard to lift heavy objects. Further, the operational workspace inside the glovebox is restricted by the gloves' reachability. Safety of workers is the paramount concern in glovebox operations and the very reason for their existence. Sharp edges and tools increases the risk of glove punctures, which may expose the operator to chemicals and radiation and risks contamination in the vicinity outside the glovebox. The operators are also affected by ergonomic stressors due to prolonged and repetitive operations. To achieve a high degree of human safety, robotic solutions to handle high-consequence materials inside the glovebox are desirable, as they remove the operators from the hazards listed above. However, robots, in general, lack the degree of adaptability necessary for most high-consequence material handling tasks as these tasks are often unstructured or highly variable. Likewise, most human operators, while highly skilled in the tasks at hand (task expertise), lack the robot programming skills necessary to adapt the robot's motions to the variations (programming expertise). A way to bridge this divide is to make robot programming more intuitive to human operators. Since humans naturally teach one another through demonstration and learning, robotic 'programming by demonstration' paradigms have begun to appear to reduce the burden of robot reprogramming. Gesture-Based Programming attempts to achieve that by enabling a robot to observe the normal actions and affordances of a human performing a task to learn to map those onto the skills of the robot. In the end, this approach permits benefits from both the human and the robot: the human's adaptive decision making and the robot's resilience to high-consequence material. Robotic solutions assuringly provide protection for the operators, however their autonomy brings about other potential risks. Artificial Intelligence is not perfect; it is a black box, which can produce results, but the full extent of those results may not be known precisely. In self-driving cars, a hypothetical AI problem is the 'green man detector'. Since self-driving cars have presumably never seen a green man, how can we know it won't veer toward him the first time it sees a green man? Likewise, even though GbP provides an open method for safe task execution replicating a human, incorrect task inferences can lead to potential collisions or unintended operations. Thus, a hardware safety measure is proposed to provide reliable operation inside the glovebox, and true safe operations are achieved by mechanically limiting the operational range of each arm link. The operational range is computed and validated through exhaustive offline simulations, which can be streamlined by affordable computing power. Super Baxter is one such robot which incorporates these capabilities. It is a human-like, bimanual robot, being developed at the Collaborative Robotics Lab (CRL) in conjunction with the Dept. of Energy/Environmental Management, Rethink Robotics, Barrett Technology, and the NSF Center for Robots and Sensors for the Human Well-Being (RoSe-HUB). Super Baxter is envisioned to represent the next generation of collaborative robots that will be intrinsically human-safe, as well as exceptionally human-intuitive. In summary, Super Baxter will enable safe glovebox operations through low-shot Gesture based Programming incorporated with hardware safety measures. Two aspects of safety will be discussed in the paper. First, the safety of the operator achieved by allowing him to program Super Baxter remotely through Gesture based Programming. Second, the safety of the glovebox, achieved by incorporating hardware safety measures using joint limits. Further, the capability of Super Baxter on Gesture based Programming is demonstrated through typical object manipulation tasks in glovebox operations. (authors)

42 ENGINEERING↗

Seismic Testing of Glovebox Feedthrough Connectors and Vacuum Pumps

In the design of tritium processing systems, the glovebox stripper system processes the glovebox atmosphere to recover tritium released inside the glovebox confinement. The glovebox stripper system must also be capable of processing the additional in-leakage caused by a Design Basis Accident (DBA) earthquake, in order to maintain the glovebox pressure negative relative to the room. However, it is unknown how much additional leakage occurs from electrical bulkhead feedthrough connectors after a DBA event. As there are dozens of these connectors on a tritium glovebox system, the potential increase in in-leakage can be significant. One vital part of the glovebox stripper system are the vacuum pumps that maintain the negative atmosphere of the glovebox following a DBA earthquake. The pumps must be able to operate following an earthquake. One candidate pump is the Senior Aerospace MB-602 Metal Bellows (Met-Bel) pump. A second alternative is the hermetically sealed Edwards Vacuum nXDS15iC Scroll Pump. The Edwards scroll pump is potentially a less expensive alternative to the Met-Bel pumps, but it is unknown if this scroll pumps will survive a DBA accident and remain operational. In order to determine the electrical feedthrough in-leakage and the candidate pumps’ survivability, a seismic test was performed to simulate a DBA earthquake. This report summarizes the results of seismic test, including helium leak rates and functionality tests for the electrical feedthroughs and vacuum pumps. All components had pre- and post-test leak rates less than the threshold valve of 1x10 -6 scc per sec.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle↗

Automated Glovebox Work-cell Design - 18370

Los Alamos National Laboratory (LANL) is the primary plutonium science and manufacturing facility in the United States supporting multiple national security programs. It is responsible for completing a high variety of small-batch manufacturing tasks requiring the handling and precision machining of Special Nuclear Materials (SNM). Given the myriad of tasks that must be completed in a limited workspace, LANL intends to utilize flexible, multi-use robotic work-cells capable of completing a variety of mission critical tasks in a single glovebox with no re-tooling needed between batch jobs. This approach would allow LANL more flexibility in its production schedule and to meet its future production and research objectives. In this paper, we present a system that integrates multiple sensors and other manufacturing peripherals into existing glovebox infrastructure. Currently, a technician can place an object in the work area where vision sensors and supervisory software identify the object and its pose and automatically determine which manufacturing task to complete. Pose uncertainty is addressed in real-time by the task planner, eliminating the need for fixtures. Grasps are validated using pressure sensors, payload sensors, and grasp quality metrics to ensure that objects are not dropped or damaged during manipulation. The robot, sensors, and peripherals are controlled using open-source software built utilizing ROS (Robot Operating System), which minimizes redevelopment and allows for re-use and extensibility. Established capabilities support vision, collision-free path planning, and more, minimizing development time. For this effort, particular attention was given to the integration of general peripheral devices (drill, chuck, etc.), which is critical to efficiently utilizing ROS in manufacturing environments. This integration is achieved with an in-development framework that allows for quick integration of peripherals, including I/O devices and motors. Contact tasks utilize the Generalized Contact Control Framework (GCCF) previously developed at UT Austin. GCCF allows application developers to easily define multiple contact control tasks for a single robot. This paper summarizes the key software components necessary to develop the multi-use work-cell including existing ROS components. UT-developed software for grasp validation, peripheral integration, and contact control is presented in more depth. Finally the glovebox system is demonstrated completing a set of tasks with no fixturing necessary. Primary tasks include surface preparation/ablation, drilling, press-fitting, and sorting, as well as supporting material transfer and inspection tasks. The glovebox work-cell reduces cost, operator dose, ergonomic issues, and time loss due to material transfer between gloveboxes that only support one task. If multiple glovebox work-cells are in use, they have the potential to eliminate bottlenecks and scale production capabilities beyond current limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Potential Ergonomic Injury Risk in the Nuclear Material Processing Glovebox Environment [Capstone Project]

Gloveboxes are isolation barriers that are used within many different industries such as pharmaceuticals, electronic parts fabrication, nuclear, and biological. The research on glovebox ergonomics is currently limited with few ergonomic professionals that focusing exclusively on glovebox working environments. There is existing documentation on occupational injuries, such as musculoskeletal disorders (MSD), sustained as a direct result of working in gloveboxes. The main elements that pose ergonomic risks to glovebox workers are operational repetition, duration, force, vibration, lifting heavy (more than 15lbs with two hands) objects, and awkward postures. This paper examines a small sample of the potential causal or risk factors that lead to the ergonomic injuries. A meta-analysis utilizing a random effect model is used to examine data from several studies which focus on, dexterity and strength changes as result of glove thickness, and robotic assistive technology as a means to improve postural mechanics. With the meta-analysis technique, similar data sets from different research studies can be coalesced into a single weighted, statistically significant result for subsequent consideration. The results from the analysis show that increased glove thickness results in decreased dexterity for operators thus increasing ergonomic risk factors such as task duration. It is also shown that glove thickness decreases grip strength but a similar decrease in pinch strength is not definitively demonstrated. With decreased grip strength, operators will need to exert more force (a known ergonomic risk factor) on processing tools, etc. during operations thus increasing the risk of ergonomic injury. The use of robotic assistive technology as a means to improve operator posture (risk factor) was also examined. Although it may be intuitively assumed that human-robotic collaboration would be beneficial in reducing risk factors, the result from this study’s analysis was not statistically significant. It is inferred that with additional directed research on this topic another study/analysis could be statistically significant demonstrating the benefits of the technology.

99 GENERAL AND MISCELLANEOUS↗

Glovebox Ergonomics Basics for Ergonomists Course #50606 [Slides]

Upon completion of this course participants will: Have an understanding of common topics and terms associated with glovebox basics. Be able to identify common types of musculoskeletal disorders. Be able to identify high risk activities associated with glovebox activities. Be able to demonstrate knowledge of glovebox ergonomic controls and best practices. Be able to demonstrate knowledge of glovebox ergonomic design/usage guidance and best practices. Be able to demonstrate knowledge of preventable exercises for glovebox ergonomic injuries.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Human and Robotic Testing in Gloveboxes to Reduce Worker Fatigue - 19542

A DOE-sponsored study conducted by the Los Alamos National Laboratory reported that the incidence rate of repetitive stress injuries (RSI) during manipulation tasks in glovebox and hot cell workspaces increased from 22% after 1-2 hours of work per day to 50% after 3 hours of work per day due to fatigue, repetitive motion, and hyperextension. Robotics can be a viable solution to this issue as robotic manipulators and wearable robotic devices can provide effective assistance to alleviate the workload. In order to use the robotic devices, an initial study to detect the amount of fatigue experienced by the glovebox operators is essential. Hence, in the present research two objectives have been specified and investigated. These include the use of electromyography (EMG) sensors to precisely detect the fatigue in various hands, arm and shoulder muscles and; the use of dexterous robotic arm and hand combinations to effectively perform certain repetitive and monotonous tasks conducted inside an in-house glovebox constructed for the research. A UR5 robotic arm and an i-limb artificial hand have been used. Human tests included eight subjects and two customized glovebox tasks. Pilot scale test results indicate variation in the mean frequency which is an indication of the level of fatigue that occurred. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium Prototype Glovebox and Furnace Design and Build (SPC-2954)

This specification contains the requirements for design, analysis, fabrication, testing and delivery of the Uranium Prototype Glovebox (UPG) and Furnace, and the associated equipment as described herein. The UPG will be primarily used for the containment of uranium and the prototyping of equipment to be used in higher hazard category gloveboxes. This will allow complex pieces of equipment to be tested in a less hazardous environment prior to fabrication and installation in other gloveboxes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Glovebox Fires Phase 1: Simulations of Open Burner Experiments

Understanding the duration of a fire required to breach a glovebox via glove ports and/or windows within a facility is important in developing mitigation strategies for safety. To facilitate this understanding, both simulation and experiments are utilized. The approach is to first validate the Computation Fluid Dynamics (CFD) code, Fire Dynamics Simulator (FDS), with experimental data collected by New Mexico Tech (NMT) and then perform simulations of full-scale rooms containing gloveboxes to assess numerous scenarios which would otherwise be cost-prohibitive experimentally. This report provides comparison to first-phase experiments involving a fire without a glovebox. A subsequent report will provide comparison to experiments involving a glovebox. The results indicate good agreement with FDS tending to over predict the pre-mixed and diffusion-mode tests by 6% and 10%, respectively.

42 ENGINEERING↗

Molten Salt Electrochemical Reactors Outside of a Glovebox

Molten salt electrochemical reduction (MSER) offers an electrified method for the reduction, refining, and recycling of metals such as iron and metallurgical grade silicon at high efficiency and lower temperatures than traditional methods, which use temperatures >1000C and carbon-based reductants. However, salts appropriate for MSER are moisture and air sensitive, necessitating air-free methods of processing and testing which is often acomplished with a glovebox. Glovebox operations are cumbersome and difficult to troubleshoot reactor issues. We have developed a robust method of testing chloride and carbonate salts in molten salt reactors outside of a glovebox for silicon and carbon production and steel carburization. We highlight a practical guide for glovebox-free testing of molten salt electrochemical reactors to reduce the barriers to performing this type of work. Our aim is to enable other research groups to step into this field with simple and repeatable reactor configurations.

47 OTHER INSTRUMENTATION↗

Evaluation of Cease Fire CFP 640 for Use in Gloveboxes (Final Report)

A Los Alamos National Laboratory (LANL) task group was established to discuss and evaluate a candidate fire suppression system (FSS) for gloveboxes (GB) and dropboxes (DB, for brevity, this report will simply refer to gloveboxes). Suitability criteria include compliance, compatibility, and capability. LANL contracted with New Mexico Tech (NMT) to quantitatively evaluate the perfor mance of one of those systems including its ability to extinguish GB fires, limit over-pressurization of the GB, etc. Additionally, the results of these experiments provide data points that could be used when fire hazard evaluations (FHEs) are conducted for determining when to require a fire suppres sion system installation within a GB (as required by NFPA 801, Standard for Facilities Handling Radioactive Materials, DOE Standard 1066-2012 Fire Protection, and AGS-G010-2011 Standard of Practice for Glovebox Fire Protection).

42 ENGINEERING↗

A cleanroom in a glovebox

The exploration of new materials, novel quantum phases, and devices requires ways to prepare cleaner samples with smaller feature sizes. Initially, this meant the use of a cleanroom that limits the amount and size of dust particles. However, many materials are highly sensitive to oxygen and water in the air. Furthermore, the ever-increasing demand for a quantum workforce, trained and able to use the equipment for creating and characterizing materials, calls for a dramatic reduction in the cost to create and operate such facilities. To this end, we present our cleanroom-in-a-glovebox, a system that allows for the fabrication and characterization of devices in an inert argon atmosphere. Additionally, we demonstrate the ability to perform a wide range of characterization as well as fabrication steps, without the need for a dedicated room, all in an argon environment. Finally, we discuss the custom-built antechamber attached to the back of the glovebox. This antechamber allows the glovebox to interface with ultra-high vacuum equipment such as molecular-beam epitaxy and scanning tunneling microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photogrammetry: Develop methods for detecting deviations from expected geometry of components in a glovebox environment (Lawrence Livermore National Laboratory Aging and Lifetimes Program FY23, Milestone 8651, Grading Criterion #4)

Measurements in glovebox environments are challenging to conduct. Currently deployed techniques are time consuming and provide limited information. These limitations make current disposition and future assessments of products challenging. In FY23 we developed methods for detecting deviations of components in a glovebox environment that address these shortcomings by rapidly collecting information-dense measurements. Conducted tests demonstrate that camera pose (position and orientation) can be derived for images utilized in the photogrammetry process. This information, in conjunction with common image processing techniques, enables automated detection and size estimation of surface features. First, image processing is used to identify marks, or localized regions, that standout from the surrounding area. Then, the physical size of the region can be estimated because scale can be determined for photogrammetry images. Development of this methods shows that photogrammetry can identify measurable deviations from expected geometries. Although measurement error when using this technique through a glovebox window still needs to be reduced, this capability shows promise for eliminating or reducing the use of tedious manual measurements.

42 ENGINEERING↗

Lessons Learned Converting A Commercial Enclosure to a Uranium Handling Glovebox

This presentation highlights the conversion of a commercial Directed Energy Deposistion machine to a radiological glovebox. An overview of some of the advanced manufacturing capabilities at INL is outlined along with some definitions and facts of additive manufacturing. The upgrades to the commercially purchased Optomec LENS MR-7 and the difficulties with qualifying it as a radiological glovebox are presented.

3-D Printing↗