Engineering PapersSearch

SEARCH · Engineering Papers

Results for “GLAMR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang

Evaluation of GLAMR-Based Calibration for SI-Traceable Field Reflectance Retrievals

The reflected solar instrument that is part of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is being formulated with a goal of providing SI-traceable measurement of radiance that is an order of magnitude more accurate than the current imaging sensors. The Goddard Laser for Absolute Measurement of Radiance (GLAMR) is a key element to reaching such accuracy along with transferring the laboratory calibration to on-orbit measurements. Results from field reflectance retrievals using three separate instruments all of which have been calibrated using GLAMR are shown. The instruments include a commercial field spectrometer and a portable version of CLARREO's calibration demonstration system. The third instrument is NASA Goddard's Lidar, Hyperspectral and Thermal Imager (G-LiHT) which is an airborne system. All three were operated during a March 2013 measurement campaign at Red Lake Playa, Arizona as part of the on-orbit commissioning phase of Landsat 8. Reflectance is derived from near-coincident measurements by the three sensors for a small area of the playa. The retrieved results are SI-traceable and demonstrate the ability to transfer the GLAMR calibration to the field. Use of the G-LiHT data in the calibration of Landsat-7 and -8 sensors permits them both to be placed on the GLAMR-scale as well.

Angal, Amit

Results from Source-Based and Detector-Based Calibrations of a CLARREO Calibration Demonstration System

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is formulated to determine long-term climate trends using SI-traceable measurements. The CLARREO mission will include instruments operating in the reflected solar (RS) wavelength region from 320 nm to 2300 nm. The Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO and facilitates testing and evaluation of calibration approaches. The basis of CLARREO and SOLARIS calibration is the Goddard Laser for Absolute Measurement of Response (GLAMR) that provides a radiance-based calibration at reflective solar wavelengths using continuously tunable lasers. SI-traceability is achieved via detector-based standards that, in GLAMRs case, are a set of NIST-calibrated transfer radiometers. A portable version of the SOLARIS, Suitcase SOLARIS is used to evaluate GLAMRs calibration accuracies. The calibration of Suitcase SOLARIS using GLAMR agrees with that obtained from source-based results of the Remote Sensing Group (RSG) at the University of Arizona to better than 5 (k2) in the 720-860 nm spectral range. The differences are within the uncertainties of the NIST-calibrated FEL lamp-based approach of RSG and give confidence that GLAMR is operating at 5 (k2) absolute uncertainties. Limitations of the Suitcase SOLARIS instrument also discussed and the next edition of the SOLARIS instrument (Suitcase SOLARIS- 2) is expected to provide an improved mechanism to further assess GLAMR and CLARREO calibration approaches. (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

Angal, Amit

Detector Based Calibration of a Portable Imaging Spectrometer for CLARREO Pathfinder Mission

The Climate Absolute Refractivity and Reflectance Observatory (CLARREO) Pathfinder (CPF) mission is being developed to demonstrate SI-traceable retrievals of reflectance at unprecedented accuracies for global satellite observations. An Independent Calibration of the CPF sensor using the Goddard Laser for Absolute Measurement of Radiance (GLAMR) is planned to allow validation of CPF accuracies. GLAMR is a detector-based calibration system relies on a set of NIST-calibrated transfer radiometers to assess the spectral radiance from the GLAMR sphere source to better than 0.3 % (k=2). The current work describes the calibration of the Solar, Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS) that was originally developed as a calibration demonstration system for the CLARREO mission and is now being used to assess the independent calibration being developed for CPF. The methodology for the radiometric calibration of SOLARIS is presented as well as results from the GLAMR-based calibration of SOLARIS. The portability of SOLARIS makes it capable of collecting field measurements of earth scenes and direct solar and lunar irradiance similar to those expected during the on-orbit operation of the CPF sensor. Results of SOLARIS field measurements are presented. The use of SOLARIS in this effort also allows the testing protocols for GLAMR to be improved and the field measurements by SOLARIS build confidence in the error budget for GLAMR calibrations. Results are compared to accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

Aytac, Yigit

Prelaunch Spectral Characterization of the Operational Land Imager-2

The Landsat-9 satellite, launched in September 2021, carries the Operational Land Imager-2 (OLI-2) as one of its payloads. This instrument is a clone of the Landsat-8 OLI and its mission is to continue the operational land imaging of the Landsat program. The OLI-2 instrument is not significantly different from OLI though the instrument-level pre-launch spectral characterization process was much improved. The focal plane modules used on OLI-2 were manufactured as spares for OLI and much of the spectral characterization of the components was performed for OLI. However, while the spectral response of the fully assembled OLI was characterized by a double monochromator system, the OLI-2 spectral characterization made use of the Goddard Laser for Absolute Measurement of Radiance (GLAMR). GLAMR is a system of tunable lasers that cover 350–2500 nm which are fiber-coupled to a 30 in integrating sphere permanently monitored by NIST-traceable radiometers. GLAMR allowed the spectral characterization of every detector of the OLI-2 focal plane in nominal imaging conditions. The spectral performance of the OLI-2 was, in general, much better than requirements. The final relative spectral responses (RSRs) represent the best characterization any Landsat instrument spectral response. This paper will cover the results of the spectral characterization from the component-level to the instrument-level of the Landsat-9 OLI-2.

Landsat-9

JPSS-2 VIIRS version 2 at-launch relative spectral response characterization

The JPSS-2 VIIRS sensor has completed its pre-launch test program and is now awaiting launch in the 2022 timeframe. The VIIRS spectral characterization, in the form of band averaged and supporting detector level relative spectral response (RSR) for each VIIRS band, was completed in 2019 and is based upon independent SpMA dual monochromator (all bands) and GSFC GLAMR laser system (reflectance bands only) spectral measurements, including first time measurements of the VIIRS SWIR bands by a laser system. The measurements and subsequent analysis effort by subject matter experts of the VIIRS DAWG has led to the July 2019 VIIRS Version 2 RSR release, the official at-launch RSR characterization for the JPSS-2 VIIRS mission. Version 2 replaces and improves upon the August 2018 Version 1 release by incorporating the GLAMR measurements into the analysis to produce an updated “fused” RSR for reflective solar bands (M1- M10, I1-I3, DNBLGS, DNBMGS) and by applying a CO2 absorption correction to the SpMA measurements for thermal band M13. For all other bands (M11, M12, M14-M16, I4, I5), the Version 1 characterization, based entirely upon the SpMA measurements, is carried forward into the Version 2 release. An assessment on compliance with spectral performance metrics finds that VIIRS is compliant on nearly all metrics, with a few minor exceptions. The version 2 RSR release includes band average (over all detectors and subsamples) RSR plus supporting RSR for each detector and subsample, and is available under EAR99 restrictions to the science community at a restricted access NASA eRoom site.

JPSS-2

JPSS-4 VIIRS Version 2 at-Launch Relative Spectral Response Characterization

The JPSS-4 VIIRS sensor, the last in a JPSS program that will eventually span some 25+ years of on-orbit data collection, has completed its pre-launch test program. The test program included measurements for characterizing the VIIRS relative spectral response (RSR) in support of the Sensor and Environmental Data Records that will be generated from JPSS-4 VIIRS on-orbit observations after launch. Subject matter experts of the Government Team’s VIIRS DAWG have analyzed the VIIRS spectral measurements and produced the VIIRS spectral characterization, in the form of band averaged and supporting detector level RSR for each VIIRS band. The characterization is based upon the analysis of independent SpMA dual monochromator (all bands) and GSFC GLAMR laser system (reflectance bands only) spectral measurements. The SpMA and GLAMR measurements for reflectance bands (DNBLGS and DNBMGS, I1-I3, M1-M11) were combined to produce a “fused” RSR. For emissive bands (I4, I5, M12-M16), the SpMA measurements provide the entire characterization. The effort has led to the VIIRS Version 2 RSR product, the official at-launch RSR characterization for the JPSS-4 VIIRS mission, which is currently slated to be the next launch (expected Fall 2027) of the JPSS program. As expected, the JPSS-4 RSR are a close match to those of JPSS-3 and JPSS-2 (NOAA-21) VIIRS, while showing some spectral position and shape differences with SNPP and JPSS-1 (NOAA-20) VIIRS. An assessment on compliance with spectral performance metrics finds that VIIRS bandaverage RSR are compliant on nearly all metrics, with only a single minor exception. The Version 2 RSR will be available under EAR99 restrictions to the science community on the restricted access NASA Sharepoint.

SDR

JPSS-3 VIIRS Version 2 at-Launch Relative Spectral Response Characterization

The JPSS-3 VIIRS sensor has completed its pre-launch test program including measurements for characterizing the VIIRS relative spectral response (RSR) in support of the Sensor and Environmental Data Records (SDR and EDR, resp.) that will be generated from VIIRS on-orbit observations. Government team subject matter experts of the VIIRS DAWG have analyzed the VIIRS spectral measurements and produced the VIIRS spectral characterization, in the form of band-average and supporting detector level RSR for each VIIRS band. The characterization is based upon the analysis of independent SpMA dual monochromator (all bands) and GSFC GLAMR laser system (reflectance bands only) spectral measurements. The SpMA and GLAMR measurements for reflectance bands (DNB LGS and MGS, I1-I3, M1-M11) were combined to produce a “fused” RSR. For emissive bands (I4, I5, M12-M16), the SpMA measurements provide the characterization. The effort has led to the VIIRS Version 2 RSR release, the official at-launch RSR characterization for the JPSS-3 VIIRS mission. The JPSS-3 RSR are a close match to those of JPSS-2. An assessment on compliance with spectral performance metrics finds that VIIRS band-average RSR are compliant on nearly all metrics, with only a single minor exception. The Version 2 RSR release is available under EAR99 restrictions to the science community on the restricted access NASA Sharepoint.

Chris Moeller

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration

First Results from Laser-Based Spectral Characterization of Landsat 9 Operational Land Imager-2

Landsat 9 will continue the Landsat data record into its fifth decade with launch scheduled for December 2020. The two instruments on Landsat 9 are Thermal Infrared Sensor-2 (TIRS-2) and Operational Land Imager-2 (OLI-2). OLI-2 is a nine-channel pushbroom imager with a 15-degree field of view that will have a 16-day measurement cadence from its nominal 705-km orbit altitude. A key aspect of the data that will be produced by OLI-2 is its spectral fidelity which enables countless science applications. The prelaunch test campaign for spectral characterization of OLI-2 was substantially improved relative to the methodology used for OLI: the full spectral response of every detector was characterized with greater accuracy, sampling, and precision. This paper will describe how this was accomplished with a tunable laser-based light source called Goddard Laser for Absolute Measurement of Radiance (GLAMR).

tunable laser

Characterization of Firefly, an Imaging Spectrometer Designed for Airborne Measurements of Solar-Induced Fluorescence

FIREFLY (Fluorescence Imaging of REd and Far-red Light Yield) is a compact, fine-resolution imaging spectrometer that was designed and assembled by Headwall Photonics (Fitchburg, MA, USA) in collaboration with NASA scientists for airborne measurements of Solar-Induced Fluorescence (SIF). FIREFLY is integrated into the next generation of NASA Goddard’s Lidar, Hyperspectral and Thermal airborne imager (G-LiHT; www.gliht.nasa.gov), providing a complete system for measuring, interpreting and scaling SIF emissions. Characterization of FIREFLY was performed here to evaluate its performance and suitability for retrieving SIF.

Imaging Spectroscopy