Nuclear Data Sheets for A=85

Evaluated experimental data are presented for 13 known nuclides of mass 85 (Zn, Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo). Since the previous 1990 evaluation of A=85, {sup 85}Zn, {sup 85}Ga, {sup 85}Ge and {sup 85}nuclides are newly added here. Excited state data for {sup 85}Se, {sup 85}Zr have become available from radioactive decay and in–beam γ–ray studies. New and improved high–spin data are available for {sup 85}Br, {sup 85}Kr, {sup 85}Rb, {sup 85}Y, {sup 85}Nb and {sup 85}Mo. New direct and precise measurement of atomic masses of {sup 85}Ge, {sup 85}As, {sup 85}Se, {sup 85}Br, {sup 85}Rb, {sup 85}Zr, {sup 85}Nb and {sup 85}Mo have greatly improved the landscape of β decay–Q values and separation energies in this mass region. In spite of extensive experimental work on the isobaric nuclei of this mass chain several deficiencies remain. No excited states are known in {sup 85}Zn, {sup 85}Ga, {sup 85}As. Only a few excited state are assigned in {sup 85}Ge from {sup 85}Ga β– decay. From radioactivity studies, the decay schemes of {sup 85}Zn and {sup 85}Mo are not known, and those for {sup 85}Ga, {sup 85}Ge, {sup 85}As and 10.9–s isomer of {sup 85}Zr are incomplete. Level lifetimes are not known for excited states in {sup 85}Se, {sup 85}Br, {sup 85}Nb and {sup 85}Mo. The {sup 85}Tc nuclide has not been detected in fragmentation experiments at GANIL, alluding to its unbound nature for proton emission. The {sup 85}Kr, {sup 85}Rb, {sup 85}Sr, and {sup 85}Y nuclides remain the most extensively studied from many different reactions and decays. The evaluation of A=85 nuclides has been done after a span of 23 years, thus includes an extensive amount of new data for almost each nuclide. This work supersedes the data for A=85 nuclides presented in earlier full NDS publication by J. Tepel in 1980Te04 and a later one published in an update mode by H. Sievers in 1991Si01.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Beta-delayed Neutron Measurements in the Light-mass Fission Group

A new accurate determination of beta-delayed neutron emission probabilities from nuclei in the low mass region of the light fission group has been performed. The measurements were carried out using the BELEN 4π neutron counter at the IGISOL-JYFL mass separator in combination with a Penning trap. The new results significantly improve the uncertainties of neutron emission probabilities for {sup 91}Br, {sup 86}As, {sup 85}As, and {sup 85}Ge nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hydrometallurgical recovery of germanium from coal gasification fly ash. Solvent extraction method

This article is concerned with a simple hydrometallurgical method for the selective recovery of germanium from fly ash (FA) generated in an integrated gasification with combined cycle (IGCC) process. The method is based on the leaching of FA with water and a subsequent concentration and selective separation of germanium by a solvent method. Regarding the leaching step, the different operational conditions studied were liquid/solid (L/S) ratio and time of contact. The solvent extraction method was based on germanium complexation with catechol (CAT) in an aqueous solution followed by the extraction of the Ge-CAT complex with an extracting organic reagent diluted in an organic solvent. The main factors examined during the extraction tests were aqueous phase/organic phase (AP/OP) volumetric ratio, aqueous phase pH, amounts of reagents, and time of contact. Germanium extraction yields were higher than 90%. Alkaline and acid stripping of organic extracts were studied obtaining the best results with 1M NaOH (85%). A high-purity germanium solution was obtained. Experimental data presented in this work show that the extraction of germanium by the solvent method designed can be selective toward germanium, and this element can be effectively separated from arsenic, molybdenum, nickel, antimony, vanadium, and zinc.

01 COAL, LIGNITE, AND PEAT↗

A dark matter search using the final CDMS-II data and 100 mm SuperCDMS germanium detector ionization test

Astrophysical observations indicate that approximately 85% of the matter in the universe is nonluminous, nonbaryonic, and nonrelativistic (cold) dark matter. Weakly Interacting Massive Particles (WIMPs) are a particularly well motivated dark matter particle candidate. They would be thermally produced in the early universe and their relics account for the current dark matter abundance. WIMP candidate particles are naturally provided by extensions to the Standard Model of particle physics, such as supersymmetry. The Cryogenic Dark Matter Search (CDMS) experiment operates cryogenic germanium and silicon particle detectors in the low-background environment of the Soudan Underground Laboratory in northern Minnesota to search for WIMP-nucleus scatters while rejecting electron-recoil background. The detectors simultaneously measure the ionization and phonon energies of each scattering event. The difference in ionization yield (ratio of ionization energy to recoil energy) discriminates nuclear recoils from the electron-recoil background efficiently.More sensitive detectors are required to probe the WIMP parameter space with lower WIMP-nucleon scattering cross sections. To support the R&D effort especially the detector R&D and characterization of the SuperCDMS experiment, a new CDMS test facility has been developed on the University of Minnesota campus. This thesis documents the test facility and the work involved in its development. In the test facility, we performed the first ionization collection efficiency measurements of the ionization test devices. The test devices are fabricated with detector-grade germanium crystals that are 100 mm in diameter, which is the largest available, and 33 mm in thickness. The measured efficiencies are consistent with the earlier measurements conducted with smaller Ge crystals, demonstrating that these 100 mm crystals can be used for development of the next generation dark matter detectors.Improvements of data analysis methods can also potentially improve the sensitivity of an experiment. The data taken during the last four runs of CDMS II with total raw exposure 612 kg-day were reprocessed with improved ionization pulse reconstruction algorithm. We present the classic timing analysis with the reprocessed data in this thesis. For the four runs combined, this analysis resulted in a new WIMP-nucleon cross section 4.4×10 -44 cm 2 for a WIMP mass of 70 GeV, which is a factor of 1.6 improvement compared to the original c58 classic timing analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

A Segmented, Enriched N-type Germanium Detector for Neutrinoless Double Beta-Decay Experiments

We present data characterizing the performance of the _rst segmented, N- type Ge detector, isotopically enriched to 85% 76Ge. This detector, based on the Ortec PT6x2 design and referred to as SEGA (Segmented, Enriched Germanium Assembly), was developed as a possible prototype for neutrinoless double beta-decay measurements by the Majorana collaboration. We present some of the general characteristics (including bias potential, efficiency, leakage current, and integral cross-talk) for this detector in its temporary cryostat. We also present an analysis of the resolution of the detector, and demonstrate that for all but two segments there is at least one channel that reaches the Majorana resolution goal below 4 keV FWHM at 2039 keV, and all channels are below 4.5 keV FWHM.

detector↗

New subshell closure at N=58 emerging in neutron-rich nuclei beyond {sup 78}Ni

The structure of neutron-rich nuclei beyond {sup 78}Ni was studied using postaccelerated radioactive beams of {sup 83,84,85}Ga utilizing beta gamma and beta-n gamma spectroscopy. Our data, when combined with energy level systematics, suggests a possible new spherical subshell closure at N=58 is created by the nearly degenerated nu3s{sub 1/2} and nu2d{sub 5/2} orbitals being well separated from other orbitals above N=50. The near degeneracy of these states could be evidenced by isomerism in this region. The energies of the 2{sub 1}{sup +} and proposed 4{sub 1}{sup +} states observed in N=52 {sup 84}Ge are interpreted as an indication of a possible weakening of the doubly magic {sup 78}Ni core for nuclei beyond N=50. The experimental evidence is supported by spherical HFB calculations using the SkO{sub T} functional involving the tensor term in the nucleon-nucleon interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Adhesion of Antireflective Coatings in Multijunction Photovoltaics

The development of a new composite dual cantilever beam (cDCB) thin-film adhesion testing method is reported, which allows the measurement of adhesion on the fragile thin substrates used in multijunction photovoltaics. We address the adhesion of several antireflective coating systems on multijunction cells. By varying interface chemistry and morphology, we demonstrate the ensuing effects on adhesion and help to develop an understanding of how high adhesion can be achieved, as adhesion values ranging from 0.5 J/m2 to 10 J/m2 were measured. Damp Heat (85 degrees C/85% RH) was used to invoke degradation of interfacial adhesion. We show that even with germanium substrates that fracture easily, quantitative measurements of adhesion can still be made at high test yield. The cDCB test is discussed as an important new methodology, which can be broadly applied to any system that makes use of thin, brittle, or otherwise fragile substrates.

14 SOLAR ENERGY↗

SU-F-I-56: High-Precision Gamma-Ray Analysis of Medical Isotopes

Purpose: Advanced, time-resolved, Compton-suppressed gamma-ray spectroscopy with germanium detectors is implemented for assaying medical isotopes to study the radioactive decay process leading to a more accurate appraisal of the received dose and treatment planning. Lowell’s Array for Radiological Assay (LARA), a detector array that is comprised of six Compton-suppressed high-purity germanium detectors, is currently under development at UMass-Lowell which combines Compton-suppression and time-and-angle correlations to allow for highly efficient and highly sensitive measurements. Methods: Two isotopes produced Brookhaven Linac Isotope Producer (BLIP) were investigated. {sup 82}Sr which is the parent isotope for producing {sup 82}Rb is often used in cardiac PET. {sup 82}Sr gamma-ray spectrum is dominated by the 511keV photons from positron annihilation which prevent precise measurement of co-produced contaminant isotopes. A second project was to investigate the production of platinum isotopes. Natural platinum was bombarded with protons from 53MeV to 200MeV. The resulting spectrum was complicated due to the large number of stable platinum isotopes in the target, the variety of open reaction channels (p,xn), (p,pxn), (p,axn). Results: By using face-to-face NaI(Tl) counters 90-degrees to the Compton-suppressed germaniums to detect the 511keV photons, a much cleaner and more sensitive measurement of {sup 85}Sr and other contaminants was obtained. For the platinum target, we identified the production of {sup 188–189–191–195}Pt, {sup 191–192–193–194–195–196}Au and {sup 186–188–189–190–192–194–189–190–192–194}Ir. For example, at the lower energies (53 and 65MeV), we measured {sup 191}Pt production cross-sections of 144mb and 157mb. Considerable care was needed in following the process of dissolving and diluting the samples to get consistent results. The new LARA array will help us better ascertain the absolute efficiency of the counting system and more reliable production cross-sections. Conclusion: Modern HPGe spectroscopic techniques provide enhanced sensitivity, promising precise quantification of the quality of radioisotopes used in medical physics. Using new decay information may have non-trivial impact on treatment planning and dose-assessment.

07 ISOTOPE AND RADIATION SOURCES↗

Quantitative adhesion characterization of antireflective coatings in multijunction photovoltaics

We discuss the development of a new composite dual cantilever beam (cDCB) thin-film adhesion testing method, which enables the quantitative measurement of adhesion on the thin and fragile substrates used in multijunction photovoltaics. In particular, we address the adhesion of several 2- and 3-layer antireflective coating systems on multijunction cells. By varying interface chemistry and morphology through processing, we demonstrate the marked effects on adhesion and help to develop an understanding of how high adhesion can be achieved, as adhesion values ranging from 0.5 J/m2 to 10 J/m2 were measured. Damp heat (85 degrees C/85% RH) was used to invoke degradation of interfacial adhesion. We demonstrate that even with germanium substrates that fracture relatively easily, quantitative measurements of adhesion can be made at high test yield. The cDCB test is discussed as an important new methodology, which can be broadly applied to any system that makes use of thin, brittle, or otherwise fragile substrates.

14 SOLAR ENERGY↗

Multi-keV x-ray sources from metal-lined cylindrical hohlraums

As multi-keV x-ray sources, plastic hohlraums with inner walls coated with titanium, copper, and germanium have been fired on Omega in September 2009. For all the targets, the measured and calculated multi-keV x-ray power time histories are in a good qualitative agreement. In the same irradiation conditions, measured multi-keV x-ray conversion rates are {approx}6%-8% for titanium, {approx}2% for copper, and {approx}0.5% for germanium. For titanium and copper hohlraums, the measured conversion rates are about two times higher than those given by hydroradiative computations. Conversely, for the germanium hohlraum, a rather good agreement is found between measured and computed conversion rates. To explain these findings, multi-keV integrated emissivities calculated with RADIOM [M. Busquet, Phys. Fluids 85, 4191 (1993)], the nonlocal-thermal-equilibrium atomic physics model used in our computations, have been compared to emissivities obtained from different other models. These comparisons provide an attractive way to explain the discrepancies between experimental and calculated quantitative results.

36 MATERIALS SCIENCE↗

Screening and Spectral Summing of LANL Empty Waste Drums - 13226

Empty 55-gallon drums that formerly held transuranic (TRU) waste (often over-packed in 85- gallon drums) are generated at LANL and require radiological characterization for disposition. These drums are typically measured and analyzed individually using high purity germanium (HPGe) gamma detectors. This approach can be resource and time intensive. For a project requiring several hundred drums to be characterized in a short time frame, an alternative approach was developed. The approach utilizes a combination of field screening and spectral summing that was required to be technically defensible and meet the Nevada Nuclear Security Site (NNSS) Waste Acceptance Criteria (WAC). In the screening phase of the operation, the drums were counted for 300 seconds (compared to 600 seconds for the typical approach) and checked against Low Level (LL)/TRU thresholds established for each drum configuration and detector. Multiple TRU nuclides and multiple gamma rays for each nuclide were evaluated using an automated spreadsheet utility that can process data from up to 42 drums at a time. Screening results were reviewed by an expert analyst to confirm the field LL/TRU determination. The spectral summing analysis technique combines spectral data (channel-by-channel) associated with a group of individual waste containers producing a composite spectrum. The grouped drums must meet specific similarity criteria. Another automated spreadsheet utility was used to spectral sum data from an unlimited number of similar drums grouped together. The composite spectrum represents a virtual combined drum for the group of drums and was analyzed using the SNAP{sup TM}/Radioassay Data Sheet (RDS)/Batch Data Report (BDR) method. The activity results for a composite virtual drum were divided equally amongst the individual drums to generate characterization results for each individual drum in the group. An initial batch of approximately 500 drums were measured and analyzed in less than 2 months in 2011. A second batch of approximately 500 more drums were measured and analyzed during the following 2 1/2 months. Four different HPGe detectors were employed for the operation. The screening and spectral summing approach can reduce the overall measurement and analysis time required. However, developing the technical details and automation spreadsheets requires a significant amount of expert time prior to beginning field operations and must be considered in the overall project schedule. This approach has continued to be used for characterizing several hundred more empty drums in 2012 and is planned to continue in 2013. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Background Method of Isotope Markers for Measuring the Efficiency of Intercalation of Graphite by Potassium Atoms

The result of low-background measurements of the gamma activity of graphite-potassium intercalated sample is presented. A germanium gamma spectrometer, used for measurements, was located in the low-background chamber of Baksan Neutrino Observatory. For 384 hours of exposure, 768 decays of K-40 isotope nuclei were registered. This activity corresponds to 85 μg/cm{sup 2} potassium atoms embedded in to graphite lattice. A computer simulation of the intercalation process and the gamma-ray spectrum set is also presented. The accuracy of the potassium concentration determination can be brought to 10{sup –}11–10{sup –}12 g/g for mixture enriched with K-40 isotope.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Factors affecting eluation characteristics of sorption generators of technetium-99m

The influence of the adsorbed mass of molybdenum on the width of eluation profiles of generators and the patterns of molybdenum distribution in the amount of chromatographic columns by scanning them on the germanium-gallium detector using collimating device are studied. The boundary conditions under which the maximum value of {sup 99m}Tc yield from generators Y{sub e} = 1 are defined. After scanning the columns, it was found out that the degree of filling the columns with molybdenum Q and the value of its maximum adsorption depend naturally on the total weight of the adsorbed mass. In order to achieve the condition Y{sub e} = 1 the value of Q should be at least 85%.

07 ISOTOPE AND RADIATION SOURCES↗

High-precision measurements of half-lives for 69 Ge, 73 Se, 83 Sr, 85 mSr, and 63 Zn radionuclides relevant to the astrophysical p-process via photoactivation at the Madison Accelerator Laboratory

The ground state half-lives of 69 Ge, 73 Se, 83 Sr, 63 Zn, and the half-life of the 1/2 - isomer in 85 Sr have been measured with high precision using the photoactivation technique at an unconventional bremsstrahlung facility that features a repurposed medical electron linear accelerator. The γ -ray activity was counted over about 6 half-lives with a high-purity germanium detector, enclosed into an ultra low-background lead shield. The measured half-lives are: T 1/2 ( 69 Ge) = 38.82 ± 0.07 (stat) ± 0.06 (sys) h; T 1/2 ( 73 Se) = 7.18 ± 0.02 (stat) ± 0.004 (sys) h; T 1/2 ( 83 Sr) = 31.87 ± 1.16 (stat) ± 0.42 (sys) h; T 1/2 ( 85m Sr) = 68.24 ± 0.84 (stat) ± 0.11 (sys) min; T 1/2 ( 63 Zn) = 38.71 ± 0.25 (stat) ± 0.10 (sys) min. These high-precision half-life measurements will contribute to a more accurate determination of corresponding ground-state photoneutron reaction rates, which are part of a broader effort of constraining statistical nuclear models needed to calculate stellar nuclear reaction rates relevant for the astrophysical p -process nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Band Structure of {sup 85}Sr

High spin states in {sup 85}Sr were populated using the reaction {sup 76}Ge({sup 13}C, 4n) at a beam energy of 52 MeV. Gamma-gamma coincidence measurements along with investigation of directional correlation ratios were utilized to establish the extended level scheme upto I{sup {pi}}= (35/2{sup -}). One of the positive parity states observed at 3383.3 keV ((I{sup {pi}}= 19/2{sup (+)}) may be considered as a magnetic rotational ({Delta}I = 1) band, the negative parity states built on 3028.0 level show an irregular behaviour and does not exhibit magnetic rotation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector Simulation and WIMP Search Analysis for the Cryogenic Dark Matter Search Experiment

Astrophysical and cosmological measurements on the scales of galaxies, galaxy clusters, and the universe indicate that 85% of the matter in the universe is composed of dark matter, made up of non-baryonic particles that interact with cross-sections on the weak scale or lower. Hypothetical Weakly Interacting Massive Particles, or WIMPs, represent a potential solution to the dark matter problem, and naturally arise in certain Standard Model extensions. The Cryogenic Dark Matter Search (CDMS) collaboration aims to detect the scattering of WIMP particles from nuclei in terrestrial detectors. Germanium and silicon particle detectors are deployed in the Soudan Underground Laboratory in Minnesota. These detectors are instrumented with phonon and ionization sensors, which allows for discrimination against electromagnetic backgrounds, which strike the detector at rates orders of magnitude higher than the expected WIMP signal. This dissertation presents the development of numerical models of the physics of the CDMS detectors, implemented in a computational package collectively known as the CDMS Detector Monte Carlo (DMC). After substantial validation of the models against data, the DMC is used to investigate potential backgrounds to the next iteration of the CDMS experiment, known as SuperCDMS. Finally, an investigation of using the DMC in a reverse Monte Carlo analysis of WIMP search data is presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Low Level and Transuranic Waste Segregation and Low Level Waste Characterization at the 200 Area of the Hanford Site - 12424

This paper describes the waste measurement and waste characterization activities carried out by ANTECH Corporation (ANTECH) and CH2M Hill Plateau Remediation Company (CHPRC) at the 200 Area of the Hanford Site under Contracts No. 22394 and No. 40245 for the US Department of Energy (DOE). These include Low Level Waste (LLW) and Transuranic (TRU) Waste segregation and LLW characterization for both 55-gallon (200-litre) drums with gross weight up to 454 kg and 85-gallon over-pack drums. In order to achieve efficient and effective waste drum segregation and assay, ANTECH deployed an automated Gamma Mobile Assay Laboratory (G-MAL) at the trench face in both 200 Area West and East. The unit consists of a modified 40 foot ISO shipping container with an automatic flow through roller conveyor system with internal drum weigh scale, four measurement and drum rotation positions, and four high efficiency high purity Germanium (HPGe) detectors with both detector and shadow shields. The unit performs multiple far-field measurements and is able to segregate drums at levels well below 100 nCi/g. The system is sufficiently sensitive that drums, which are classified as LLW, are characterized at measurement levels that meet the Environmental Restoration Disposal Facility (ERDF) Waste Acceptance Criteria (WAC). With measurement times of between 20 and 30 minutes the unit can classify and characterize over 40 drums in an 8-hour shift. The system is well characterized with documented calibrations, lower limits of detection (LLD) and total measurement uncertainty. The calibrations are confirmed and verified using nationally traceable standards in keeping with the CHPRC measurement requirements. The performance of the system has been confirmed and validated throughout the measurement process by independent CHPRC personnel using traceable standards. All of the measurement and maintenance work has been conducted during the period under a Quality Assurance Plan (QAP) compliant with the applicable criteria of NQA-1 (2000). This includes not only the calibrations and measurements but also the data analysis activities of the ANTECH Subject Matter Experts (SME) and ANTECH support and maintenance activities as well as the activities of CHPRC staff who recover, transport and load waste drums and disposition measured and characterized drums. The overall processes of drum recovery and analysis are described in the paper. Specific spectral data is presented which illustrates the segregation, sentencing and assay process for different types of drums with different radionuclide profiles. The process of identifying and quantifying a wide range of non-TRU radionuclide isotopes is explained and illustrated with spectral examples. The difficulties associated with the measurement of drums with a high gamma ray background, usually arising from high levels of Cs-137 are considered. These drums, which would normally be declared indeterminate and treated as TRU, are addressed under contract No. 40245 by the deployment of the ANTECH Neutron Mobile Assay Laboratory. This is an Active-Passive neutron assay system housed in a modified ISO shipping container. The unit is designed for the measurement and assay of both drums and crates (including B-25 boxes and SWB containers) and will quantify the content of both plutonium and uranium. The neutron system has been employed to perform further evaluation on indeterminate drums to classify them to either LLW or TRU. The experiences of both gamma ray and neutron system operation in different conditions are described; as are the issues of throughput, drum handling and system maintenance. All of these are considered in the overriding context of safe drum handling and safe assay system operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of Solvent on the Capacity Retention in a Germanium Anode for Lithium Ion Batteries

A thin and mechanically stable solid electrolyte interphase (SEI) is desirable for a stable cyclic performance in a lithium ion battery. For the electrodes that undergo a large volume expansion such as Si, Ge and Sn, the presence of a robust SEI layer can improve the capacity retention. In this work, the role of solvent choice on the electrochemical performance of Ge electrode is presented by a systematic comparison of the SEI layers in EC-based and FEC-based electrolytes. The results show that the presence of FEC as a co-solvent in a binary or ternary solvent electrolyte results in an excellent capacity retention of ~ 85% after 200 cycles at the current density of 500 mA·g-1; while EC-based electrode suffers a rapid capacity degradation with a capacity retention of just 17% at the end of 200 cycles. Post analysis by an extensive use of x-ray photoelectron spectroscopy was carried out, which showed that the presence of Li2O in FEC-based SEIs was the origin for the improved electrochemical performance.

Mishra, Kuber↗