DURABLE HIGH TEMPERATURE COATINGS FOR UTILITY SCALE GAS TURBINE HOT GAS PATH COMPONENTS (PHASE II STTR)
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Raising turbine inlet temperature is a key lever for improving industrial gas-turbine efficiency and power output, but it increases thermo-mechanical demands on hot-gas-path components. Additive manufacturing (AM), particularly laser powder bed fusion (L-PBF), enables complex internal cooling features in critical components such as turbine tip shoes that are difficult to produce by conventional casting. However, qualification of new high-temperature AM alloys and aggressive geometries is often limited by trial-and-error iteration of build parameters and post-build heat treatments, with cracking during stress relieving or hot isostatic pressing (HIP) being a recurring failure mode.
An airfoil for a turbine of a gas turbine engine is provided. The airfoil comprises a main body comprising a wall structure defining an inner cavity adapted to receive a cooling air. The wall structure includes a first diffusion region and at least one first metering opening extending from the inner cavity to the first diffusion region. The wall structure further comprises at least one cooling circuit comprising a second diffusion region and at least one second metering opening extending from the first diffusion region to the second diffusion region. The at least one cooling circuit may further comprise at least one third metering opening, at least one third diffusion region and a fourth diffusion region.
The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.
Combustion instability in gas turbines can be mitigated using active techniques or passive techniques, but passive techniques are almost exclusively used in industrial settings. While fuel staging, a common passive technique, is effective in reducing the amplitude of self-excited instabilities in gas turbine combustors at steady-state conditions, the effect of transients in fuel staging on self-excited instabilities is not well understood. This paper examines the effect of fuel staging transients on a laboratory-scale five-nozzle can combustor undergoing self-excited instabilities. The five nozzles are arranged in a four-around-one configuration and fuel staging is accomplished by increasing the center nozzle equivalence ratio. When the global equivalence ratio is φ = 0.70 and all nozzles are fueled equally, the combustor undergoes self-excited oscillations. These oscillations are suppressed when the center nozzle equivalence ratio is increased to φ = 0.80 or φ = 0.85. Two transient staging schedules are used, resulting in transitions from unstable to stable operation, and vice-versa. It is found that the characteristic instability decay times are dependent on the amount of fuel staging in the center nozzle. It is also found that the decay time constants differ from the growth time constants, indicating hysteresis in stability transition points. High speed CH* chemiluminescence images in combination with dynamic pressure measurements are used to determine the instantaneous phase difference between the heat release rate fluctuation and the combustor pressure fluctuation throughout the combustor. This analysis shows that the instability onset process is different from the instability decay process.
Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged-stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τT Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a given τ Transient , the decay timescale decreased with increasing staging equivalence ratio. For 1, 16, and 58 ms transients, τ does not depend on τ Transient , though it does strongly depend on direction, where instability onset cases have longer and more variable τ than instability decay cases. The same dependence of τ on direction is seen for the 4,000 and 10,000 ms transients. However, unlike the short duration transients, τ does depend on τ Transient as would be expected. Phase space reconstruction shows the instability is a harmonic limit cycle with a single frequency. The instantaneous phase images shows the center region of the combustor goes out-of-phase first followed by the rest of the combustor. Finally, asymmetric fuel staging tests are conducted. It is found that non-axisymmetric staging can be as effective as axisymmetric staging, although small hardware variations between nozzles can affect the the minimum staging equivalence ratio that consistently suppresses the instability. These changes in the bifurcation equivalence ratio can make staging configurations appear less effective; however, both axisymmetric and non-axisymmetric staging configurations exhibit similar staged-stable p' RMS , damping rates, and instability transition times for equivalence ratios greater than the bifurcation equivalence ratio. Instantaneous phase images show similar instantaneous phase relationship structures in the staged nozzle (center or outer), suggesting that the instability suppression mechanism is similar in each case. This result is surprising given that the time-averaged flame shapes are very different between axisymmetric and non-axisymmetric staging configurations. The similar effectiveness of axisymmetric and non-axisymmetric staging in this geometry is attributed to the fact that the instability mode is a nominally axisymmetric plane wave. It is hypothesized that non-axisymmetric staging configurations will likely be more effective than axisymmetric staging configurations when the instability mode shape is asymmetric (such as a circumferential wave).
Flexible resources are increasingly important as variable renewable energy deployment in the power system increases. Although many systems are transitioning away from fossil fuels, open-cycle gas turbines are likely to play an important balancing role for some time, thus requiring accurate modeling of their operational parameters. This paper explores the impact of detailed representation of three operational parameters - start- up costs, run-up rates, and forced outage rates - in the production cost model of a system as it adopts higher levels of wind and solar. Using PLEXOS simulations of the NREL-118 bus test system, the study examines how more detailed parameter modeling affects outcomes such as the number of start-ups and shutdowns, ramping and total generation costs for open-cycle gas turbines, as renewable energy levels increase. The results suggest the value of detailed parameter modeling and continued research on combustion turbines' ability to provide flexibility.
Higher turbine inlet temperatures may require the use of ceramic matrix composites (CMC) such as SiC/SIC, which require environmental barrier coatings (EBCs) to protect them against the detrimental effect of water vapor. Here, the goal of this project is to determine the maximum bond coating temperature for EBCs for land-based turbines, where the minimum coating lifetime is 25,000 h. If the temperature exceeds the 1414°C melting point of the Si bond coating, then coatings without a bond coating also need to be evaluated. Thus, current Yb 2 Si 2 O 7 EBCs with a Si bond coating and next-generation EBCs without a Si bond coating are being evaluated in laboratory testing using 1-h cycles in air+90%H 2 O. For this initial work, coatings were deposited on CVD SiC coupons. Reaction kinetics at 1250°, 1300° and 1350°C have been evaluated by measuring the thickness of the thermally grown silica scale after 100–500 h exposures. For comparison, scale growth rates for uncoated SiC and Si specimens in dry and wet environments were included as minimum and maximum values, respectively. Based on a critical scale thickness failure criteria, estimated maximum temperatures were calculated for both EBC systems using this initial data.
A gas turbine including a working fluid flowpath extending aftward from a forward injector in a combustor. The combustor may include an inner radial wall, an outer radial wall, and, therebetween, a flow annulus, and a third radial wall formed about the outer radial wall that forms an outer flow annulus. A staged injector may intersect the flow annulus so to attain an injection point within the working fluid flowpath by which aftward and forward annulus sections are defined. Air directing structure may include an aftward intake section corresponding to the aftward annulus section and a forward intake section corresponding to the forward annulus section. The air directing structure may include a switchback coolant flowpath to direct air from the compressor discharge cavity to the staged injector. The switchback coolant flowpath may include an upstream section through the flow annulus, and a downstream section through the outer flow annulus.
A gas turbine that includes a working fluid flowpath extending aftward from a forward injector in a combustor. The combustor may include an inner radial wall, an outer radial wall, and, therebetween, a flow annulus. A staged injector may intersect the flow annulus so to attain an injection point within the working fluid flowpath by which aftward and forward annulus sections are defined. Air directing structure may include an aftward intake section that corresponds to the aftward annulus section and a forward intake section that corresponds to the forward annulus section. The air directing structure may be configured to: direct air entering through the aftward intake section through the aftward annulus section in a forward direction to the staged injector; and direct air entering through the forward intake section through the forward annulus section in a forward direction to the forward injector.
A gas turbine that includes a working fluid flowpath extending aftward from a forward injector in a combustor. The combustor may include an inner radial wall, an outer radial wall, and, therebetween, a flow annulus. A staged injector may intersect the flow annulus so to attain an injection point within the working fluid flowpath by which aftward and forward annulus sections are defined. Air directing structure may include an aftward intake section that corresponds to the aftward annulus section and a forward intake section that corresponds to the forward annulus section. The air directing structure may be configured to: direct air entering through the aftward intake section through the aftward annulus section in a forward direction to the staged injector; and direct air entering through the forward intake section through the forward annulus section in an aftward direction to the staged injector.
A gas composition sensor based on Raman spectroscopy using reflective metal lined capillary waveguides is tested under field conditions for feed-forward applications in gas turbine control. The capillary waveguide enables effective use of low powered lasers and rapid composition determination, for computation of required parameters to pre-adjust burner control based on incoming fuel. Tests on high pressure fuel streams show sub-second time response and better than one percent accuracy on natural gas fuel mixtures. Fuel composition and Wobbe constant values are provided at one second intervals or faster. The sensor, designed and constructed at NETL, is packaged for Class I Division 2 operations typical of gas turbine environments, and samples gas at up to 800 psig. Simultaneous determination of the hydrocarbons methane, ethane, and propane plus CO, CO<sub>2</sub>, H<sub>2</sub>O, H<sub>2</sub>, N<sub>2</sub>, and O<sub>2</sub> are realized. The capillary waveguide permits use of miniature spectrometers and laser power of less than 100 mW. The capillary dimensions of 1 m length and 300 μm ID also enable a full sample exchange in 0.4 s or less at 5 psig pressure differential, which allows a fast response to changes in sample composition. Sensor operation under field operation conditions will be reported.
Not provided.
A gas turbine includes forward and aft rows of rotatable blades, a row of stationary vanes between the forward and aft rows of rotatable blades, an annular intermediate disc, and a seal housing apparatus. The forward and aft rows of rotatable blades are coupled to respective first and second portions of a disc/rotor assembly. The annular intermediate disc is coupled to the disc/rotor assembly so as to be rotatable with the disc/rotor assembly during operation of the gas turbine. The annular intermediate disc includes a forward side coupled to the first portion of the disc/rotor assembly and an aft side coupled to the second portion of the disc/rotor assembly. The seal housing apparatus is coupled to the annular intermediate disc so as to be rotatable with the annular intermediate disc and the disc/rotor assembly during operation of the gas turbine.
In this paper, an experimental and numerical investigation of internal cooling channels with rib turbulators is presented with sCO 2 as the working fluid at process conditions (pressure-20.7 MPa and temperature up to 150 °C). The effect of channel aspect ratio up to 2:1 on thermal-hydraulic performance is explored in additively manufactured rectangular channels and square channels, both with and without 60 deg ribs on the top and bottom sides. The Wilson-plot method is employed to experimentally measure channel-averaged Nusselt number over a Reynolds number range up to 370,000. The friction factor is calculated from pressure drop and mass flow rate and additionally, the overall thermal performance factor (TPF) is reported. A companion computational fluid dynamics (CFD) simulation is performed for the rib turbulated cooling configurations reported in the experiments using the Reynolds average Navier–Stokes-based turbulence model. The objective of the numerical study is to gain insight into the local heat transfer augmentation in the ribbed channels as a result of varying the aspect ratio, channel configuration (square versus rectangular), operating conditions (Reynolds number) and the surface roughness, an inherent outcome of the additive manufacturing process. Surface roughness is simulated using sand grain roughness height (K S ) calculated from the experimental data, and a comparison is presented with the corresponding channel configuration with varying surface roughness heights starting from smooth surfaces (K S = 0). Experimental results indicate that the heat transfer augmentation is negligible in the rectangular channels with ribs on the long side compared to the square channel. However, it is enhanced by 60% in comparison to placing ribs on the shorter side. The TPF remains constant at around 1 for the entire range of Reynolds numbers consistent with prior work at the National Energy Technology Laboratory (NETL). Here, the simulation results highlight that increased surface roughness can have a favorable considerable influence on Nusselt number and overall thermal performance enhancement.
High-hydrogen gas turbines enable integration of carbon sequestration into coal-gasifying power plants, though NO{sub x} emissions are often high. This work explores nitrogen dilution of hydrogen diffusion flames to reduce thermal NO{sub x} emissions and avoid problems with premixing hydrogen at gas turbine pressures and temperatures. The burner design includes an array of high-velocity coaxial fuel and air injectors, which balances stability and ignition performance, combustor pressure drop, and flame residence time. Testing of this array injector at representative gas turbine conditions (16 atm and 1750 K firing temperature) yields 4.4 ppmv NO{sub x} at 15% O{sub 2} equivalent. NO{sub x} emissions are proportional to flame residence times, though these deviate from expected scaling due to active combustor cooling and merged flame behavior. The results demonstrate that nitrogen dilution in combination with high velocities can provide low NO{sub x} hydrogen combustion at gas turbine conditions, with significant potential for further NO{sub x} reductions via suggested design changes.