Gain suppression study on LGADs at the CENPA tandem accelerator
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.
The detection of primordial B modes of the cosmic microwave background (CMB) could provide information about the early stages of the Universe's evolution. The faintness of this signal requires exquisite calibration accuracy and control of instrumental systematic effects which otherwise could bias the measurements. In this work, we study the impact of an imperfect relative polarisation gain calibration on the recovered value of the tensor-to-scalar ratio r for the LiteBIRD experiment, through the application of the blind Needlet Internal Linear Combination (NILC) foreground-cleaning method. We derive requirements on the relative calibration accuracy of the overall polarisation gain (Δg ν ) for each LiteBIRD frequency channel. Our results show that minimum variance techniques, as NILC, are less sensitive to systematic gain calibration uncertainties compared to a parametric approach, if the latter is not equipped with a proper modelling of these instrumental effects. In this study, the most stringent requirements are found in the channels where the CMB signal is relatively brighter, with the tightest constraints at 166 GHz (Δg ν ≈ 0.16%). This differs from the outcome of an analogous analysis performed with a parametric method, where the tightest requirements are obtained for the foreground-dominated channels. Gain calibration uncertainties, corresponding to the derived requirements, are then simultaneously propagated into all frequency channels. By doing so, we find that the overall impact on estimated r is lower than the total gain systematic budget for LiteBIRD approximately by a factor 5, due to the correlations of the impacts of gain calibration uncertainties in different frequency channels. In order to decouple the systematic effect from the specific choice of the model, we derive the requirements assuming constant spectral parameters for the foreground emission. To assess the robustness of the obtained results against more realistic scenarios, we repeat the analysis assuming sky models of intermediate and high complexity. In these further cases, we adopt an optimised NILC pipeline, called the Multi-Clustering NILC (MC-NILC). We find that the impact of gain calibration uncertainties on r is lower than the LiteBIRD gain systematics budget for the intermediate-complexity sky model. For the high-complexity case, instead, it would be necessary to tighten the requirements by a factor 1.8.
Tunable, unipolar, near-infrared intraband optical gain is demonstrated in semiconductor colloidal quantum wells, expanding the form and optical range for potential infrared applications. Atomically flat colloidal quantum wells of cadmium selenide display photoinduced absorption features in the near-infrared assigned to intraband (alternatively intersubband) transitions from the first to second electron subbands of the quantum wells. Under ultraviolet optical excitation, these same transitions from the first to second electron subbands are shown to exhibit stimulated emission, resulting in optical gain covering the near-infrared spectral region. The modal gain, bandwidth, and lifetime of this intraband gain are manipulated by using excitation energy, fluence, temperature, and surface chemistry. Unlike previous demonstrations of intraband optical gain in epitaxial quantum wells (e.g., quantum cascade lasers), the colloidal quantum wells are undoped. As a result, nearly thresholdless gain is in principle possible and limited in practice by the measurement of small optical losses of the samples in the near-infrared. Furthermore, the observations may be understood as a modified "quantum fountain" employing the valence band, a strategy that may be applied to many other materials.
Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.
This paper introduces a gain-scheduling PID controller design strategy for hydroturbine frequency control mode. This scheme first uses real data to learn the nonlinear dynamics of the hydroturbine using neural controlled differential equations and then perturbs the obtained nonlinear system at different equilibrium points, based on which a static output feedback adaptive dynamic programming algorithm is then used to optimize the PID gains for each equilibrium point. Moreover, a continuous-time version of stochastic distribution control is proposed to further fine-tune the optimized PID gains. Finally, the controller is obtained by implementing linear interpolation between the optimized PID control gains. The simulation results show that the proposed gain-scheduling PID controller can control a larger range of operation points compared with the given fixed PID controller and the baseline method. Compared with the given fixed PID controller, the proposed gain-scheduling PID controller can regulate hydroturbine frequency against disturbances induced by power-load variation with over 50% less overshoot for some operation points.
LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.
Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.
We present a detailed derivation of a formula for the small-gain calculation for an x-ray free electron laser oscillator (XFELO) based on a medium-energy (3–4 GeV) storage ring. We found harmonic lasing and strong focusing are essential for this beam energy range. Taking the small-signal low-gain formula developed by Kim and his colleagues, we modified it in such a way that the gain can be calculated without the “no focusing approximation,” and a strong focusing can be applied, as well as harmonic lasing. In this formula, the gain is represented as a product of two factors with one of them depending only on the harmonic number, undulator period, and gap. Using this factor, we show that it is favorable to use harmonic lasing to achieve hard x-ray FEL working in the small-signal low-gain regime with the medium-energy electron beam. Our formula also allows FEL optimization by varying the vertical gradient of the undulator, the vertical dispersion, and the horizontal and vertical focusing, independently. As an example, we applied this formula to study the feasibility of an XFELO option for the National Synchrotron Light Source II (NSLS-II) upgrade. Since a quite high peak current is required for the FEL, collective effects of beam dynamics in medium-energy synchrotrons significantly affect the electron beam parameters. We carried out a multiparameter optimization taking collective effects into account. Note, even though our example is for a ring-based XFELO at 3 to 4 GeV, the formula and, in particular, the approach developed here may be applied to other types of FELs. Published by the American Physical Society 2024
The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.
Ultra-high intensity laser–plasma interactions can produce ultra-relativistic electrons via direct laser acceleration, assisted by quasi-static plasma magnetic and electric fields. These fields transversely confine electron motion and induce betatron oscillations. The net energy gain is strongly influenced by the interplay between two frequencies: the betatron frequency and the frequency of laser field oscillations experienced by the electron. Prior work has shown that energy gain is enabled by a resonance between the betatron oscillations and the oscillations of the laser field. In particular, higher-order resonances occur when the laser field completes multiple cycles during one betatron oscillation, allowing additional regimes of energy transfer beyond the fundamental (betatron) resonance. In this work, we demonstrate that such resonances become particularly effective when the laser's phase velocity is superluminal. Although the two frequencies generally evolve differently with increasing electron energy—leading to detuning—a superluminal phase velocity introduces a non-monotonic frequency ratio with a global minimum. This minimum allows sustained frequency matching over a broad energy range, thereby enabling enhanced energy gain. As the phase velocity increases, the betatron resonance becomes ineffective due to premature frequency detuning. At the same time, higher-order resonances become increasingly effective, emerging as the dominant mechanisms for enhanced energy gain in this regime of direct laser acceleration.
Fourth-generation diffraction-limited synchrotron light sources (DL-SLS) present a compelling platform for advanced light source applications due to their ultra-low emittance (around tens of picometers), sub-micrometer beam stability, and high repetition rates (greater than 1 MHz). Despite these advantages, fundamental limitations, such as long bunch durations (tens of picoseconds), large relative energy spread (~10⁻³), and low peak current (<300 A), have hindered their effectiveness in free-electron laser (FEL) applications. Using a low-gain three-dimensional (3D) model based on NSLS-II upgrade lattice parameters, we demonstrate that a 6% single-pass gain is achievable with an optimized transverse gradient undulator (TGU). Concurrently, recent advances in X-ray optics—specifically, a four-mirror bow-tie resonator utilizing diamond mirrors and beryllium compound refractive lenses (CRLs)—enable total round-trip losses below 4% and an output coupling efficiency near 1%, rendering a Storage Ring based X-ray FEL oscillator (XFELO) a realistic possibility. In the 3D framework, the TGU effectively mitigates the detrimental effects of large energy spread by spatially dispersing the beam, leading to enhanced gain relative to conventional one-dimensional (1D) models. We establish both analytical and numerical connections between the 1D and 3D descriptions, leveraging GENESIS simulations to map equivalent gain conditions. While 1D resonance is defined in the energy domain, the 3D TGU system shifts the resonance dependence to transverse gradient and dispersion parameters. Once optimized, this framework allows predictive modeling using 1D formulas, which can then be validated through full 3D simulations.
Abstract Exceptional points (EPs)—singularities in the parameter space of non-Hermitian systems where two nearby eigenmodes coalesce—feature unique properties with applications such as sensitivity enhancement and chiral emission. Existing realizations of EP lasers operate with static populations in the gain medium. By analyzing the full-wave Maxwell–Bloch equations, here we show that in a laser operating sufficiently close to an EP, the nonlinear gain will spontaneously induce a multi-spectral multi-modal instability above a pump threshold, which initiates an oscillating population inversion and generates a frequency comb. The efficiency of comb generation is enhanced by both the spectral degeneracy and the spatial coalescence of modes near an EP. Such an “EP comb” has a widely tunable repetition rate, self-starts without external modulators or a continuous-wave pump, and can be realized with an ultra-compact footprint. We develop an exact solution of the Maxwell–Bloch equations with an oscillating inversion, describing all spatiotemporal properties of the EP comb as a limit cycle. We numerically illustrate this phenomenon in a 5-μm-long gain-loss coupled AlGaAs cavity and adjust the EP comb repetition rate from 20 to 27 GHz. This work provides a rigorous spatiotemporal description of the rich laser behaviors that arise from the interplay between the non-Hermiticity, nonlinearity, and dynamics of a gain medium.
A hybrid dual-stage bismuth-doped fiber and neodymium-doped fiber amplifier with high optical gain and extended bandwidth of operation in the E-band is demonstrated. The amplifier features a maximum gain of 43 dB, output power of 372 mW, and a minimum noise figure of 5.5 dB, and operation wavelength range of 1397–1472 nm, enabled by 153-m of bismuth-doped fiber and two 7-m lengths of neodymium-doped fiber. The demonstration shows the possibility of achieving improved gain bandwidth by combining fiber amplifiers with overlapping gain spectra in the E-band.
In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy deposits from a proton beam were studied. Three LGAD prototypes of 50 μm, 100 μm, and 150 μm were characterized. The devices' gain was determined as a function of bias voltage, incidence beam angle, and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. LGADs are considered for the active target (ATAR), and energy linearity is an important property for particle ID capabilities.
Recent experimental demonstrations of ignition and target gain in inertial confinement fusion (ICF) have stimulated interest in exploring the fundamental physics of violent deuterium-tritium (DT) burn in high-gain ICF targets. A significant DT-burn fraction is a necessary condition for high energy gain and large neutron yields (>100MJ). Using classical molecular-dynamics (MD) simulations and a hybrid fluid-kinetic model, we examine how a large fraction of low-energy 𝛼 particles can kick D and T ions out of equilibrium in high-gain ICF targets. The MD results suggest that (1) temperatures of 𝑇 𝐷 and 𝑇 𝑇 can differ by as much as ∼20% of their mean temperature and (2) the deviation of the DT energy distribution from the Maxwell-Boltzmann function can exceed ∼30%. Some of these MD observations, such as the preferential heating of D ions by low-energy 𝛼 particles and the temperature separation, can be explained by a proposed hybrid fluid-kinetic model. Furthermore, the implication of such nonequilibrium effects on the DT reactivity is also discussed.
Maximizing the amount of work harvested from an environment is important for a wide variety of biological and technological processes, from energy-harvesting processes such as photosynthesis to energy storage systems such as fuels and batteries. Here, we consider the maximization of free energy—and by extension, the maximum extractable work—that can be gained by a classical or quantum system that undergoes driving by its environment. We consider how the free energy gain depends on the initial state of the system while also accounting for the cost of preparing the system. We provide simple necessary and sufficient conditions for increasing the gain of free energy by varying the initial state. We also derive simple formulae that relate the free energy gained using the optimal initial state rather than another suboptimal initial state. Finally, we demonstrate that the problem of finding the optimal initial state may have two distinct regimes, one easy and one difficult, depending on the temperatures used for preparation and work extraction. We illustrate our results on a simple model of an information engine.
The Photon Detection System (PDS) is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 PhotoMultiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operating at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu R5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70 °C, although this temperature is rather higher than that of the liquid Argon.