Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GADOLINIUM 157”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study of shape transitions in N{approx}90 isotopes with beyond mean field calculations

We study the spherical to prolate-deformed shape transition in {sup 144-158}Sm and {sup 146-160}Gd isotopes with modern calculations beyond the mean field with the Gogny D1S force. We compare the results with the shape-phase transition predicted by the collective Hamiltonian model and with the experimental data. Our calculations do not support the existence of a first order phase transition in these isotopic chains in the viewpoint of the Bohr Hamiltonian neither the interpretation of the nuclei N = 90 as critical points.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nuclear Data Sheets for A = 157

The experimental results from the various reaction and decay studies leading to the nuclides {sup 157}Nd, {sup 157}Pm, {sup 157}Sm, {sup 157}Eu, {sup 157}Gd, {sup 157}Tb, {sup 157}Dy, {sup 157}Ho, {sup 157}Er, {sup 157}Tm, {sup 157}Yb, {sup 157}Lu, {sup 157}Hf, {sup 157}Ta, and {sup 157}W in the A = 157 mass chain have been reviewed. These data are summarized and presented, together with adopted level schemes and properties.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Mass tensor in the Bohr Hamiltonian from the nondiagonal energy weighted sum rules

Relations are derived in the framework of the Bohr Hamiltonian that express the matrix elements of the deformation-dependent components of the mass tensor through the experimental data on the energies and the E2 transitions relating the low-lying collective states. These relations extend the previously obtained results for the intrinsic mass coefficients of the well-deformed axially symmetric nuclei on nuclei of arbitrary shape. The expression for the mass tensor is suggested, which is sufficient to satisfy the existing experimental data on the energy weighted sum rules for the E2 transitions for the low-lying collective quadrupole excitations. The mass tensor is determined for {sup 106,108}Pd, {sup 108-112}Cd, {sup 134}Ba, {sup 150}Nd, {sup 150-154}Sm, {sup 154-160}Gd, {sup 164}Dy, {sup 172}Yb, {sup 178}Hf, {sup 188-192}Os, and {sup 194-196}Pt.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of Large Neutron Detectors Containing Lithium-Gadolinium-Borate Scintillator

This paper describes the development and testing of a neutron counter, spectrometer, and dosimeter that is compact, efficient, and accurate. A self-contained neutron detection instrument has wide applications in health physics, scientific research, and programs to detect, monitor, and control strategic nuclear materials (SNM). The 1.3 liter detector head for this instrument is a composite detector with an organic scintillator containing uniformly distributed {sup 6}Li{sub 6}{sup nat}Gd{sup 10}B{sub 3}O{sub 9}:Ce (LGB:Ce) microcrystals. The plastic scintillator acts to slow impinging neutrons and emits light proportional to the energy lost by the neutrons as they moderate in the detector body. Moderating neutrons that have slowed sufficiently capture in one of the Lithium-6, Boron-10, or Gadolinium-157 atoms in the LGB:Ce scintillator, which then releases the capture energy in a characteristic cerium emission pulse. The measured captured pulses indicate the presence of neutrons. When a scintillating fluor is present in the plastic, the light pulse resulting from the neutron moderating in the plastic is paired with the LGB:Ce capture pulse to identify the energy of the neutron. About 2% of the impinging neutrons lose all of their energy in a single collision with the detector. There is a linear relationship between the pulse areas of this group of neutrons and energy. The other 98% of neutrons have a wide range of collision histories within the detector body. When these neutrons are 'binned' into energy groups, each group contains a distribution of pulse areas. This data was used to assist in the unfolding of the neutron spectra. The unfolded spectra were then validated with known spectra, at both neutron emitting isotopes and fission/accelerator facilities. Having validated spectra, the dose equivalent and dose rate are determined by applying standard, regulatory damage coefficients to the measured neutron counts for each energy bin of the spectra. Testing at the Los Alamos Neutron Science Center (LANSCE), Edwards Accelerator Laboratory (EAL) at Ohio University and the Radiation Center at University of Massachusetts-Lowell has demonstrated that the instrument can measure neutrons and their spectra over the range between 0.8 MeV and 150 MeV with an uncertainty of only ± 8%. An independent test of the LGB:Ce neutron spectrometer was conducted by a US Defense Threat Reduction Agency (DTRA) team at the Idaho National Laboratory (INL). The results of this evaluation showed that the neutron spectrometer accurately identified bare radioactive isotopes by their spectra. Further, masking and shielding materials alter those spectra in predictable ways that permit an extrapolation from the observed spectra back to the identity of the isotopic spectrum. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposed experiment to measure {gamma}-rays from the thermal neutron capture of gadolinium

Gadolinium-157 ({sup 157}Gd) has the largest thermal neutron capture cross section among any stable nuclei. The thermal neutron capture yields {gamma}-ray cascade with total energy of about 8 MeV. Because of these characteristics, Gd is applied for the recent neutrino detectors. Here, we propose an experiment to measure the multiplicity and the angular correlation of {gamma}-rays from the Gd neutron capture. With these information, we expect the improved identification of the Gd neutron capture.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of the Lattice and Spin-Phonon Contributions on the Temperature Behavior of the Ground State Splitting of Gd{sup 3+} in SrMoO{sub 4}

The temperature behavior of the EPR spectra of the Gd{sup 3+} impurity center in single crystals of SrMoO{sub 4} in the temperature range T = 99–375 K is studied. The analysis of the temperature dependences of the spin Hamiltonian b{sub 2}{sup 0}(T) = b{sub 2}(F) + b{sub 2}(L) and P{sub 2}{sup 0}(T) = P{sub 2}(F) + P{sub 2}(L) (for Gd{sup 157}) describing the EPR spectrum and contributing to the Gd{sup 3+} ground state splitting ΔE is carried out. In terms of the Newman model, the values of b{sub 2}(L) and P{sub 2}(L) depending on the thermal expansion of the static lattice are estimated; the b{sub 2}(F) and P{sub 2}(F) spin-phonon contributions determined by the lattice ion oscillations are separated. The analysis of b{sub 2}{sup 0}(T) and P{sub 2}{sup 0}(T) is evidence of the positive contribution of the spin-phonon interaction; the model of the local oscillations of the impurity cluster with close frequencies ω describes well the temperature behavior of b{sub 2}(F) and P{sub 2}(F).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Isotopic Evidence for Multi-stage Cosmic-ray Exposure Histories of Lunar Meteorites: Long Residence on the Moon and Short Transition to the Earth

It is known that most lunar meteorites have complicated cosmic-ray exposure experiences on the Moon and in space. In this study, cosmic-ray irradiation histories of six lunar meteorites, Dhofar 489, Northwest Africa 032 (NWA 032), NWA 479, NWA 482, NWA 2995, and NWA 5000, were characterized from neutron-captured isotopic shifts of Sm and Gd, and from the abundances of long-lived cosmogenic radionuclides like {sup 10}Be, {sup 26}Al, {sup 36}Cl, and {sup 41}Ca. Sm and Gd isotopic data of all of six meteorites show significant isotopic shifts of {sup 149}Sm–{sup 150}Sm and {sup 157}Gd–{sup 158}Gd caused by accumulation of neutron capture reactions due to cosmic-ray irradiation, corresponding to the neutron fluences of (1.3–9.6) × 10{sup 16} n cm{sup −2}. In particular, very large Sm and Gd isotopic shifts of NWA 482 are over those of a lunar regolith 70002, having the largest isotopic shifts among the Apollo regolith samples, corresponding to cosmic-ray exposure duration over 800 million years in the lunar surface (2 π irradiation). Meanwhile, the concentrations of cosmogenic radionuclides for individual six meteorites show the short irradiation time less than one million years as their bodies in space (4 π irradiation). Our data also support the results of previous studies, revealing that most of lunar meteorites have long exposure ages at shallow depths on the Moon and short transit times from the Moon to the Earth.

79 ASTRONOMY AND ASTROPHYSICS↗

HETEROGENEOUS ISOTOPIC ANOMALIES OF SM AND GD IN THE NORTON COUNTY METEORITE: EVIDENCE FOR IRRADIATION FROM THE ACTIVE EARLY SUN

Large and heterogeneous isotopic variations of {sup 150}Sm/{sup 149}Sm and {sup 158}Gd/{sup 157}Gd due to neutron capture reactions caused by cosmic-ray irradiation were found in chemical and mineral separates from the Norton County meteorite. The light-colored separates, consisting mainly of enstatite (Mg{sub 2}Si{sub 2}O{sub 6}), have a very large neutron fluence of 1.98 Multiplication-Sign 10{sup 17} n cm{sup -2}, which is 10 times higher than that of the whole rock. Furthermore, four chemical separates showed a large variation in neutron fluences, ranging from 1.82 Multiplication-Sign 10{sup 16} to 1.87 Multiplication-Sign 10{sup 17} n cm{sup -2}. The variable amounts of neutron fluences from a small single fragment of the Norton County meteorite cannot be simply explained by single-stage cosmic-ray irradiation in space. Rare earth element (REE) analyses revealed that the fractions with high neutron fluences have similar chemical properties to those in the early condensates in the solar system, showing depletions of Eu and Yb in their REE abundance patterns. The data provide evidence for an activity of the early Sun (T Tauri), suggesting the migration of early and intense irradiation materials into the Norton County meteorite's parent body.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the {sup 157}Gd(n,{gamma}) reaction with the DANCE {gamma} calorimeter array

The {sup 157}Gd(n,{gamma}) reaction was measured with the DANCE {gamma} calorimeter (consisting of 160 BaF{sub 2} scintillation detectors) at the Los Alamos Neutron Science Center. The multiplicity distributions of the {gamma} decay were used to determine the resonance spins up to E{sub n}=300 eV. The {gamma}-ray energy spectra for different multiplicities were measured for the s-wave resonances. The shapes of these spectra were compared with simulations based on the use of the DICEBOX statistical model code. Simulations showed that the scissors mode is required not only for the ground-state transitions but also for transitions between excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark results with a new evaluation of 155 Gd and 157 Gd

Evaluations of gadolinium isotopes 155 Gd and 157 Gd in the resolved resonance region were performed with the code SAMMY. The main objective for revising the resonance evaluations of these isotopes was to address issues related to critical benchmark results.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of burnup and isotopic compositions of BWR 9 x 9 UO{sub 2} fuel assemblies

In order to extend isotopic composition data focusing on fission product nuclides, measurements are progressing using facilities of JAEA for five samples taken from high burnup BWR 9 x 9 UO{sub 2} fuel assemblies. Neutronics analysis with an infinite assembly model was applied to the preliminary measurement data using a continuous-energy Monte Carlo burnup calculation code MVP-BURN with nuclear libraries based on JENDL-3.3 and JENDL-4.0. The burnups of the samples were determined to be 28.0, 39.3, 56.6, 68.1, and 64.0 GWd/t by the Nd-148 method. They were compared with those calculated using node-average irradiation histories of power and in-channel void fractions which were taken from the plant data. The comparison results showed that the deviations of the calculated burnups from the measurements were -4 to 3%. It was confirmed that adopting the nuclear data library based on JENDL-4.0 reduced the deviations of the calculated isotopic compositions from the measurements for {sup 238}Pu, {sup 144}Nd, {sup 145}Nd, {sup 146}Nd, {sup 148}Nd, {sup 134}Cs, {sup 154}Eu, {sup 152}Sm, {sup 154}Gd, and {sup 157}Gd. On the other hand, the effect of the revision in the nuclear. data library on the neutronics analysis was not significant for major U and Pu isotopes. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spin and Parity Assignment of Neutron Resonances using Gamma-ray Multiplicity

Decay gamma rays following neutron capture on various isotopes are collected by the Detector for Advanced Neutron Capture Experiments (DANCE) array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation (160 detectors) and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a given isotope in the time-of-flight spectrum and obtain the summed energy spectrum for that isotope. The singles gamma-ray spectrum for each multiplicity can be separated by their DANCE cluster multiplicity. The multiplicity distribution contains the signatures of spin and parity of the capture state. Under suitable circumstances where the difference between spins of the initial (capture) and final (ground) state is large enough, the signatures in the multiplicity distribution can be used in improving the spin assignment of the initial state. The spin assignment is applied with varying degree of success to difference isotopes and description of this application for {sup 95}Mo, {sup 151,153}Eu, and {sup 155,157}Gd is reviewed briefly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hexagonal Uniformly Redundant Arrays (HURAs) for scintillator based coded aperture neutron imaging

A series of Monte Carlo simulations have been conducted, making use of the EJ-426 neutron scintillator detector, to investigate the potential of using hexagonal uniformly redundant arrays (HURAs) for scintillator based coded aperture neutron imaging. This type of scintillator material has a low sensitivity to gamma rays, therefore, is of particular use in a system with a source that emits both neutrons and gamma rays. The simulations used an AmBe source, neutron images have been produced using different coded-aperture materials (boron- 10, cadmium-113 and gadolinium-157) and location error has also been estimated. In each case the neutron image clearly shows the location of the source with a relatively small location error. Neutron images with high resolution can be easily used to identify and locate nuclear materials precisely in nuclear security and nuclear decommissioning applications. (authors)

42 ENGINEERING↗

Compensated gadolinium-loaded plastic scintillators for thermal neutron detection (and counting)

Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by gadolinium-155 and gadolinium-157, alternative treatment to Pulse Shape Discrimination has to be proposed in order to display a trustable count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a non-gadolinium loaded compensation scintillator solely interacts with the photon part of the incident radiation. Posterior to the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate after photon response compensation falls into statistical fluctuations or provides a robust image of a neutron activity. A laboratory prototype is tested under both photon and neutron irradiations, allowing us to investigate the performance of the overall compensation system in terms of neutron detection, especially with regards to a commercial helium-3 counter. The study reveals satisfactory results in terms of sensitivity and orientates future investigation toward promising axes. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of gamma-emission branching ratios for {sup 154,156,158}Gd compound nuclei: Tests of surrogate nuclear reaction approximations for (n,gamma) cross sections

The surrogate nuclear reaction method can be used to determine neutron-induced reaction cross sections from measured decay properties of a compound nucleus created using a different reaction and calculated formation cross sections. The reliability of (n,gamma) cross sections determined using the Weisskopf-Ewing and ratio approximations are explored for the {sup 155,157}Gd(n,gamma) reactions. Enriched gadolinium targets were bombarded with 22-MeV protons and gamma rays were detected in coincidence with scattered protons using the Silicon Telescope Array for Reaction Studies/Livermore-Berkeley Array for Collaborative Experiments (STARS/LiBerACE) silicon and germanium detector arrays. The gamma-emission probabilities for the {sup 154,156,158}Gd compound nuclei were measured at excitation energies up to 12 MeV. It is found that the approximations yield results that deviate from directly measured {sup 155,157}Gd(n,gamma) cross sections at low energies. To extract reliable cross sections, a more sophisticated analysis should be developed that takes into account angular-momentum differences between the neutron-induced and surrogate reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gadolinia nanofibers as a multimodal bioimaging and potential radiation therapy agent

Continuous bead-free C-type cubic gadolinium oxide (Gd{sub 2}O{sub 3}) nanofibers 20-30 μm long and 40-100 nm in diameter were sintered by sol-gel calcination assisted electrospinning technique. Dipole-dipole interaction of neighboring Gd{sup 3+} ions in nanofibers with large length-to-diameter aspect ratio results in some kind of superparamagnetic behavior: fibers are magnetized twice stronger than Gd{sub 2}O{sub 3} powder. Being compared with commercial Gd-DTPA/Magnevist{sup ®}, Gd{sub 2}O{sub 3} diethyleneglycol-coated (Gd{sub 2}O{sub 3}-DEG) fibers show high 1/T{sub 1} and 1/T{sub 2} proton relaxivities. Intense room temperature photoluminescence, high NMR relaxivity and high neutron scattering cross-section of {sup 157}Gd nucleus promise to integrate Gd{sub 2}O{sub 3} fibers for multimodal bioimaging and neutron capture therapy.

36 MATERIALS SCIENCE↗

Thermal neutron capture cross section of gadolinium by pile-oscillation measurements in MINERVE

Natural gadolinium is used as a burnable poison in most LWR to account for the excess of reactivity of fresh fuels. For an accurate prediction of the cycle length, its nuclear data and especially its neutron capture cross section needs to be known with a high precision. Recent microscopic measurements at Rensselaer Polytechnic Inst. (RPI) suggest a 11% smaller value for the thermal capture cross section of {sup 157}Gd, compared with most of evaluated nuclear data libraries. To solve this inconsistency, we have analyzed several pile-oscillation experiments, performed in the MINERVE reactor. They consist in the measurement of the reactivity variation involved by the introduction in the reactor of small-samples, containing different mass amounts of natural gadolinium. The analysis of these experiments is done through the exact perturbation theory, using the PIMS calculation tool, in order to link the reactivity effect to the thermal capture cross section. The measurement of reactivity effects is used to deduce the 2200 m.s-1 capture cross section of {sup nat}Gd which is (49360 {+-} 790) b. This result is in good agreement with the JEFF3.1.1 value (48630 b), within 1.6% uncertainty at 1{sigma}, but is strongly inconsistent with the microscopic measurements at RPI which give (44200 {+-} 500) b. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gadolinium Thin Foils in a Plasma Panel Sensor as an Alternative to 3He

Gadolinium has long been investigated as a detector for neutrons. It has a thermal neutron capture cross-section that is unparalleled among stable elements, because of the isotopes $^{155,157}$Gd. As a replacement for $^3$He, gadolinium has a significant defect, it produces many gamma-rays with an energy sum of 8 MeV. It also produces conversion electrons, mostly 29 keV in energy. The key to replacing $^3$He with gadolinium is using a gamma-blind electron detector to detect the conversion electrons. We suggest that coupling a layer of gadolinium to a Plasma Panel Sensor (PPS) can provide highly efficient, nearly gamma-blind detection of the conversion. The PPS is a proposed detector under development as a dense array of avalanche counters based on plasma display technology. We will present simulations of the response of prototypes of this detector and considerations of the use of gadolinium in the PPS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗