Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GADOLINIUM 140”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A=140☆

The 2006 evaluation of A=140 was updated using experimental results published before November 2018 from the various reaction and decay studies leading to the nuclei {sup 140}Sb, {sup 140}Te, {sup 140}I, {sup 140}Xe, {sup 140}Cs, {sup 140}Ba, {sup 140}La, {sup 140}Ce, {sup 140}Pr, {sup 140}Nd, {sup 140}Pm, {sup 140}Sm, {sup 140}Eu, {sup 140}Gd, {sup 140}Tb, {sup 140}Dy, {sup 140}Ho. These data are summarized and presented, together with adopted level schemes and properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

Purpose: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. Methods: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. Results: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold and the 640 mm phantom. While gadolinium might be considered at 160 mm diameter, hafnium showed the best overall performance for phantom sizes of 320 mm and above. The measurements conducted on the clinical CT scanner showed very good agreement with simulations with deviations in the order of 5 to 10%. Conclusions: The results of this study encourage the development and use of CM based on high-Z materials, especially for adipose patients, where high tube voltages are necessary to reach sufficiently short scan times. Hafnium proved to be the best compromise for average-size and for adipose patients. Even higher-Z materials such as gold and bismuth showed a good overall performance in conjunction with high tube voltage, large patients or strong added filtration and may be recommended for scans under these conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancement in magnetocaloric properties of holmium chromite by gadolinium substitution

HoCrO{sub 3}, Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3}, and GdCrO{sub 3} bulk powder samples were prepared by citrate route. The phase purity and the structural properties of the samples were examined by x-ray diffraction and Raman spectroscopic measurements. The dc magnetization data revealed that the Cr{sup 3+} ordering temperatures (Néel temperature) for the HoCrO{sub 3}, Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3}, and GdCrO{sub 3} samples are 140 K, 148 K, and 167 K, respectively, while the ac magnetization data revealed that the rare-earth (Ho) ordering occurs at ∼8 K for HoCrO{sub 3} and Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3} samples. Temperature-induced magnetization reversal and spin reorientation were observed in GdCrO{sub 3} bulk sample, which depends on applied magnetic field and disappears at ∼1500 Oe and 500 Oe, respectively. By fitting the dc magnetic data with Curie-Weiss law, the effective magnetic moments were calculated to be 11.66 μ{sub B}, 10.23 μ{sub B}, and 9.90 μ{sub B} for the HoCrO{sub 3}, Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3}, and GdCrO{sub 3} samples, respectively. The isothermal magnetization data showed that the magnetic behavior changed from canted antiferromagnetic in low temperature region (below Néel temperature) to paramagnetic at high temperature. It was found that Gd substitution considerably improves the magnetocaloric effect of HoCrO{sub 3}. Pure GdCrO{sub 3} bulk sample showed giant magnetocaloric entropy change (31.6 J/kg K at temperature ∼5 K and at ∼70 kOe), which is higher than that for polycrystalline RMnO{sub 3}, RCrO{sub 3}, and RFeO{sub 3} bulk powder samples. This renders GdCrO{sub 3} useful for potential applications in low-temperature magnetic refrigeration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficacy of Gadolinium Gallium Garnet (GGG) as a High-Impedance Optical Window for Shock Wave Experiments

We conducted a series of plate impact experiments to examine the efficacy of < 111>-oriented gadolinium gallium garnet (GGG) single crystals as high-impedance optical window for Photonic Doppler velocimetry (PDV) under shock and double-shock loading. At ~ 123 GPa, shocked GGG remains fully transparent to 1550 nm light for at least 250 ns without any signal degradation. Above 135 GPa, PDV data measured through GGG exhibit a gradual loss of fringe contrast following shock entrance, which eventually leads to transparency loss. The duration for which shocked GGG remains transparent decreases with increasing pressure, and at ~ 148 GPa, it becomes opaque within ~ 20–30 ns. This limits the use of GGG as an interferometry window between ~ 110–140 GPa under single shock loading. Within this pressure range, the refractive index of GGG increases linearly with density: n = 1.552 + 0.054ρ. In contrast to single shock loading, where GGG becomes opaque rapidly above ~ 140 GPa, double-shocked GGG remains optically transparent for over 100 ns when it is first shocked to ~ 123 GPa and then reshocked to significantly higher pressures (215–233 GPa). Our findings raise the exciting possibility of GGG being used as a high-impedance optical window in multi-shock and shock-ramp loading experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Linear thermomagnetic energy harvester for low-grade thermal energy harvesting

Low-grade thermal energy, either from waste heat or from natural resources, constitutes an enormous energy reserve that remains to be fully harvested. Harvesting low-grade heat is challenging because of the low Carnot efficiency. Among various thermal energy harvesting mechanisms available for capturing low-grade heat (temperature less than 100 degrees C), the thermomagnetic effect has been found to be quite promising. In this study, we demonstrate a scalable thermomagnetic energy harvester architecture that exhibits 140% higher power density compared to the previously published spring-mass designs. The alternating force required to oscillate the thermomagnetic mass is generated through the interaction between two magnetic forces in opposite directions. We employed numerical modeling to illustrate the behavior of a thermomagnetic device under different operating conditions and to obtain the optimal hot-side and cold-side temperatures for continuous mode operations. A miniaturized thermomagnetic harvester was fabricated and experiments were conducted to systematically evaluate the performance. The prototype was found to exhibit an oscillation frequency of 0.33 Hz, a work output of 0.6 J/kg/cycle, and a power density of 0.2 W/kg of gadolinium under the temperature difference of 60 K.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetocaloric effect of gadolinium in high magnetic fields

The magnetocaloric effect of gadolinium has been inspected directly in pulsed magnetic fields up to 62 T. The maximum observed adiabatic temperature change is ΔT ad = 60.5 K, the initial temperature T 0 being just above 300 K. The field dependence of ΔT ad is found to follow the usual H 2/3 law, with a small correction in H 4/3 . Yet, as H is increased, a radical change is observed in the dependence of ΔT ad on T 0 , at H = const. The familiar caret-shaped peak situated at T 0 = T C becomes distinctly asymmetric, its high-temperature slope becoming more gentle and evolving into a broad plateau. For yet higher magnetic fields, μ 0 H ≳ 140 T, calculations predict a complete disappearance of the maximum near T C and an emergence of a new very broad maximum far above T C .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dipole potentials indicate restructuring of the membrane interface induced by gadolinium and beryllium ions

The dipole component of the membrane boundary potential, phi(d), is an integral parameter that may report on the conformational state of the lipid headgroups and their hydration. In this work, we describe an experimental approach to measurements of the dipole potential changes, Deltaphi(d), and apply it in studies of Be(2+) and Gd(3+) interactions with membranes composed of phosphatidylserine (PS), phosphatidylcholine (PC), and their mixtures. Deltaphi(d) is determined as the difference between the changes of the total boundary potential, phi(b), measured by the IFC method in planar lipid membranes and the surface potential, phi(s), determined from the electrophoretic mobility of liposomes. The Gouy-Chapman-Stern formalism, combined with the condition of mass balance, well describes the ion equilibria for these high-affinity cations. For the adsorption of Be(2+) and Gd(3+) to PC membranes, and of Mg(2+) to PS membranes, the values of Deltaphi(b) and Deltaphi(s) are the same, indicative of no change of phi(d). Binding of Gd(3+) to PS-containing membranes induces changes of phi(d) of opposite signs depending on the density of ionized PS headgroups in the bilayer. At low density, the induced Deltaphi(d) is negative (-30 mV), consistent with the effect of dehydration of the surface. At maximal density (pure PS, neutral pH), adsorption of Be(2+) or Gd(3+) induces an increase of phi(d) of 35 or 140 mV, respectively. The onset of the strong positive dipole effect on PS membranes with Gd(3+) is observed near the zero charge point and correlates with a six-fold increase of membrane tension. The observed phenomena may reflect concerted reorientation of dipole moments of PS headgroups as a result of ion adsorption and lipid condensation. Their possible implications to in-vivo effects of these high-affinity ions are discussed.

Non-NASA Center↗

Optimizing conversion efficiency and reducing ion energy in a laser-produced Gd plasma

We have demonstrated an efficient extreme ultraviolet (EUV) source at 6.7 nm by irradiating Gd targets with 0.8 and 1.06 {mu}m laser pulses of 140 fs to 10 ns duration. Maximum conversion efficiency of 0.4% was observed within a 0.6% bandwidth. A Faraday cup observed ion yield and time of flight signals for ions from plasmas generated by each laser. Ion kinetic energy was lower for shorter pulse durations, which yielded higher electron temperatures required for efficient EUV emission, due to higher laser intensity. Picosecond laser pulses were found to be the best suited to 6.7 nm EUV source generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

(γ, 2n)-Reaction cross-section calculations of several even-even lanthanide nuclei using different level density models

There are several level density models that can be used to predict photo-neutron cross sections. Some of them are Constant Temperature + Fermi Gas Model (CTFGM), Back-Shifted Fermi Gas Model (BSFM), Generalized Superfluid Model (GSM), Hartree-Fock-Bogoliubov microscopic Model (HFBM). In this study, the theoretical photo-neutron cross sections produced by (γ, 2n) reactions for several eveneven lanthanide nuclei such as {sup 140,142}Ce, {sup 142,144,146,148,150}Nd, {sup 144,148,150,152,154}Sm, and {sup 160}Gd have been calculated on the different level density models as mentioned above by using TALYS 1.6 and EMPIRE 3.1 computer codes for incident photon energies up to 30 MeV. The obtained results have been compared with each other and available experimental data existing in the EXFOR database. Generally, at least one level density model cross-section calculations are in agreement with the experimental results for all reactions except {sup 144}Sm(γ, 2n){sup 142}Sm along the incident photon energy, TALYS 1.6 BSFM option for the level density model cross-section calculations can be chosen if the experimental data are not available or are improbable to be produced due to the experimental difficulty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Light emission efficiency and imaging performance of Gd{sub 2}O{sub 2}S:Eu powder scintillator under x-ray radiography conditions

Purpose: To evaluate Gd{sub 2}O{sub 2}S:Eu powder phosphor as a radiographic image receptor and to compare it to phosphors often used in radiography. Gd{sub 2}O{sub 2}S:Eu is nonhygroscopic, emitting red light with decay time close to that of Gd{sub 2}O{sub 2}S:Tb. Methods: The light intensity emitted per unit of x-ray exposure rate (absolute luminescence efficiency) was measured for laboratory prepared screens with coating thicknesses of 33.1, 46.4, 63.1, 78.3, and 139.8 mg/cm{sup 2} and tube voltages ranging from 50 to 140 kVp. Parameters related to image quality such as the modulation transfer function (MTF) and the detective quantum efficiency (DQE) were also experimentally examined. In addition, a previously validated Monte Carlo code was used to estimate intrinsic x-ray absorption and optical properties, as well as the MTF and the Swank factor (I) of the Gd{sub 2}O{sub 2}S:Eu scintillators. Results: Gd{sub 2}O{sub 2}S:Eu light intensity was found higher than that of single CsI:Tl crystal for tube voltages up to 100 kVp. The MTF and the DQE were found to be comparable with those of Gd{sub 2}O{sub 2}S:Tb and CsI:Tl screens. MTF estimated by the Monte Carlo code was found very close to the experimental MTF values. Gd{sub 2}O{sub 2}S:Eu showed peak emission in the wavelength range 620-630 nm. Its emission spectrum was excellently matched to various optical detectors (photodiodes, photocathodes, CCDs, and CMOS) employed in flat panel detectors. Conclusions: Gd{sub 2}O{sub 2}S:Eu is an efficient phosphor potentially well suited to radiography and especially to some digital detectors sensitive to red light.

36 MATERIALS SCIENCE↗