Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fuzzy Logic System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Controlling of grid connected photovoltaic lighting system with fuzzy logic

In this study, DC electrical energy produced by photovoltaic panels is converted to AC electrical energy and an indoor area is illuminated using this energy. System is controlled by fuzzy logic algorithm controller designed with 16 rules. Energy is supplied from accumulator which is charged by photovoltaic panels if its energy would be sufficient otherwise it is supplied from grid. During the 1-week usage period at the semester time, 1.968 kWh energy is used from grid but designed system used 0.542 kWh energy from photovoltaic panels at the experiments. Energy saving is determined by calculations and measurements for one education year period (9 months) 70.848 kWh. (author)

14 SOLAR ENERGY↗

A self-learning disturbance observer for nonlinear systems in feedback-error learning scheme

Here this paper represents a novel online self-learning disturbance observer (SLDO) by benefiting from the combination of a type-2 neuro-fuzzy structure (T2NFS), feedback-error learning scheme and sliding mode control (SMC) theory. The SLDO is developed within a framework of feedback-error learning scheme in which a conventional estimation law and a T2NFS work in parallel. In this scheme, the latter learns uncertainties and becomes the leading estimator whereas the former provides the learning error to the T2NFS for learning system dynamics. A learning algorithm established on SMC theory is derived for an interval type-2 fuzzy logic system. In addition to the stability of the learning algorithm, the stability of the SLDO and the stability of the overall system are proven in the presence of time-varying disturbances. Thanks to learning process by the T2NFS, the simulation results show that the SLDO is able to estimate time-varying disturbances precisely as distinct from the basic nonlinear disturbance observer (BNDO) so that the controller based on the SLDO ensures robust control performance for systems with time-varying uncertainties, and maintains nominal performance in the absence of uncertainties.

42 ENGINEERING↗

Enhancing EV Motor Design Through Knowledge-Based AI and Hierarchical Fuzzy Logic Model

This work presents a novel approach to optimizing electric vehicle motor design through the integration of Knowledge-Based Artificial Intelligence (KB-AI) and Hierarchical Fuzzy Logic. Traditional motor design processes are time-intensive, relying heavily on iterative simulations and domain-specific expertise. These processes are further complicated by the nonlinear relationships between key design parameters. The proposed framework addresses these challenges by systematically encoding expert knowledge from scientific literature into a fuzzy logic system, allowing for the efficient handling of complex design variables. The hierarchical fuzzy logic model reduces computational complexity by decomposing the nonlinear relationships into manageable rule sets while maintaining design accuracy. The proposed methodology was applied to the design of a 100 kW motor, yielding optimal values for key parameters. This resulted in a compact motor design with a volume of 2.2 liters, showcasing the framework’s ability to deliver high-performance, application-specific motor configurations.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COMPARISON OF SELECTED WELD DEFECT EXTRACTION METHODS

This paper presents three different methods of welding defects detection from radiographs. First two methods are dedicated for extraction of flaws directly from radiograms. Fuzzy logic system considers whether the pixel belongs to crack (or background) using defects probability maps together with simple fuzzy rules. Neural network method uses knowledge gathered from radiographs with known defects. Indirect method extracts defects by subtracting background from the radiograph and next using various local thresholding methods.

36 MATERIALS SCIENCE↗

FN-DFE: Fuzzy-Neural Data Fusion Engine for Enhanced State-Awareness of Resilient Hybrid Energy System

Resiliency and improved state-awareness of modern critical infrastructures, such as energy production and industrial systems, is becoming increasingly important. As control systems become increasingly complex, the number of inputs and outputs increase. Therefore, in order to maintain sufficient levels of state-awareness, a robust system state monitoring must be implemented that correctly identifies system behavior even when one or more sensors are faulty. Furthermore, as intelligent cyber adversaries become more capable, incorrect values may be fed to the operators. To address these needs, this paper proposes a Fuzzy-Neural Data Fusion Engine (FN-DFE) for resilient state-awareness of control systems. The designed FN-DFE is composed of a three-layered system consisting of: 1) traditional threshold based alarms, 2) anomalous behavior detector using self-organizing fuzzy logic system, and 3) artificial neural network based system modeling and prediction. The improved control system state-awareness is achieved via fusing input data from multiple sources and combining them into robust anomaly indicators. In addition, the neural network based signal predictions are used to augment the resiliency of the system and provide coherent state-awareness despite temporary unavailability of sensory data. The proposed system was integrated and tested with a model of the Idaho National Laboratory’s (INL) hybrid energy system facility know as HYTEST. Experimental results demonstrate that the proposed FN-DFE provides timely plant performance monitoring and anomaly detection capabilities. It was shown that the system is capable of identifying intrusive behavior significantly earlier than conventional threshold based alarm systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adaptive fuzzy dynamic surface control for the chaotic permanent magnet synchronous motor using Nussbaum gain

This paper is concerned with the problem of adaptive fuzzy dynamic surface control (DSC) for the permanent magnet synchronous motor (PMSM) system with chaotic behavior, disturbance and unknown control gain and parameters. Nussbaum gain is adopted to cope with the situation that the control gain is unknown. And the unknown items can be estimated by fuzzy logic system. The proposed controller guarantees that all the signals in the closed-loop system are bounded and the system output eventually converges to a small neighborhood of the desired reference signal. Finally, the numerical simulations indicate that the proposed scheme can suppress the chaos of PMSM and show the effectiveness and robustness of the proposed method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Independent temperature and humidity control of a precooled desiccant air cooling system with proportional and fuzzy logic + proportional based controllers

Providing room comfort quickly by using less energy in cooling systems is important both in terms of efficiency and environment. In this study, independent temperature/humidity control strategies are designed for precooled desiccant based evaporative cooling system to provide room comfort quickly with less energy. Therefore, the speed controls of the system's actuators become important depending on the room, cooler and atmosphere conditions. The mathematical models are obtained to determine the relation between voltages of actuators and the variations in the room's temperature and humidity. After that, new control strategies are developed based on Proportional and Fuzzy+Proportional techniques and the control performance is increased by adding extra modes to the operation of the actuators. The effects of the control techniques on the cooling performance and energy consumption were investigated for different cases. It has been observed that the room temperature and relative humidity reach the set values in a short time for both techniques and are successfully kept at these values under the disturbances. By using Fuzzy+Proportional controller, the robustness of the cooler increases due to more precisely adjustment of controller's parameter depending the system conditions. Finally, both control strategies provide more than 20% energy savings compared to the traditional ON/OFF control.

42 ENGINEERING↗

Towards Resilient Critical Infrastructures: Application of Type-2 Fuzzy Logic in Embedded Network Security Cyber Sensor

Resiliency and cyber security of modern critical infrastructures is becoming increasingly important with the growing number of threats in the cyber-environment. This paper proposes an extension to a previously developed fuzzy logic based anomaly detection network security cyber sensor via incorporating Type-2 Fuzzy Logic (T2 FL). In general, fuzzy logic provides a framework for system modeling in linguistic form capable of coping with imprecise and vague meanings of words. T2 FL is an extension of Type-1 FL which proved to be successful in modeling and minimizing the effects of various kinds of dynamic uncertainties. In this paper, T2 FL provides a basis for robust anomaly detection and cyber security state awareness. In addition, the proposed algorithm was specifically developed to comply with the constrained computational requirements of low-cost embedded network security cyber sensors. The performance of the system was evaluated on a set of network data recorded from an experimental cyber-security test-bed.

97 MATHEMATICS AND COMPUTING↗

Fuzzy logic control and optimization system

A control system (300) for optimizing a power plant includes a chemical loop having an input for receiving an input signal (369) and an output for outputting an output signal (367), and a hierarchical fuzzy control system (400) operably connected to the chemical loop. The hierarchical fuzzy control system (400) includes a plurality of fuzzy controllers (330). The hierarchical fuzzy control system (400) receives the output signal (367), optimizes the input signal (369) based on the received output signal (367), and outputs an optimized input signal (369) to the input of the chemical loop to control a process of the chemical loop in an optimized manner.

97 MATHEMATICS AND COMPUTING↗

Computational Intelligence Based Data Fusion Algorithm for Dynamic sEMG and Skeletal Muscle Force Modelling

In this work, an array of three surface Electrography (sEMG) sensors are used to acquired muscle extension and contraction signals for 18 healthy test subjects. The skeletal muscle force is estimated using the acquired sEMG signals and a Non-linear Wiener Hammerstein model, relating the two signals in a dynamic fashion. The model is obtained from using System Identification (SI) algorithm. The obtained force models for each sensor are fused using a proposed fuzzy logic concept with the intent to improve the force estimation accuracy and resilience to sensor failure or misalignment. For the fuzzy logic inference system, the sEMG entropy, the relative error, and the correlation of the force signals are considered for defining the membership functions. The proposed fusion algorithm yields an average of 92.49% correlation between the actual force and the overall estimated force output. In addition, the proposed fusionbased approach is implemented on a test platform. Experiments indicate an improvement in finger/hand force estimation.

42 ENGINEERING↗

An ANFIS-based on B2C electronic commerce transaction

The purpose of this study is to use an adaptive-network-based fuzzy inference system to model a fuzzy logic-based system (FIS) for supporting decision-making process in B2C electronic commerce transaction. Firstly we introduce FIS in B2C electronic commerce transaction and ANFIS. Then we use ANFIS to model FIS with different membership functions(MF). Lastly we give a conclusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controlling the State of Machine Tools

Globally, manufacturers make great efforts to maintain the performance of industrial equipment. Developers and researchers are interested in automated approaches to maintaining the performance of equipment, especially at enterprises with high degrees of computerization and comprehensive information systems. In the present work, a new approach is outlined: an autonomous control system for maintaining the condition of metal-cutting machines. This approach is based on prior work in the field and permits maintenance on the basis of autonomous control of the state of machine tools. The structure of a system with the following generalized control functions is presented: decision making; and the issuing of commands on the basis of built-in resources. The formulation of control decisions employs the theory of fuzzy sets and fuzzy logic. By means of the ANFIS fuzzy network system, the autonomy of state control of the machine tool may be assessed. Criticality assessment of the condition of machine tools and their components is important in making decisions as to the setup of systems controlling the condition of equipment at enterprises, with assessment of their efficiency. In the monitoring subsystem, provision is made for assessment of the diagnostic results, prediction, and the generation of control decisions so as to prevent disruptions of machine-tool operation.

42 ENGINEERING↗

Neural and Fuzzy Adaptive Control of Induction Motor Drives

This paper proposes an adaptive neural network speed control scheme for an induction motor (IM) drive. The proposed scheme consists of an adaptive neural network identifier (ANNI) and an adaptive neural network controller (ANNC). For learning the quoted neural networks, a back propagation algorithm was used to automatically adjust the weights of the ANNI and ANNC in order to minimize the performance functions. Here, the ANNI can quickly estimate the plant parameters and the ANNC is used to provide on-line identification of the command and to produce a control force, such that the motor speed can accurately track the reference command. By combining artificial neural network techniques with fuzzy logic concept, a neural and fuzzy adaptive control scheme is developed. Fuzzy logic was used for the adaptation of the neural controller to improve the robustness of the generated command. The developed method is robust to load torque disturbance and the speed target variations when it ensures precise trajectory tracking with the prescribed dynamics. The algorithm was verified by simulation and the results obtained demonstrate the effectiveness of the IM designed controller.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fuzzy logic controller versus classical logic controller for residential hybrid solar-wind-storage energy system

Several researches for management of diverse hybrid energy systems and many techniques have been proposed for robustness, savings and environmental purpose. In this work we aim to make a comparative study between two supervision and control techniques: fuzzy and classic logics to manage the hybrid energy system applied for typical housing fed by solar and wind power, with rack of batteries for storage. The system is assisted by the electric grid during energy drop moments. A hydrogen production device is integrated into the system to retrieve surplus energy production from renewable sources for the household purposes, intending the maximum exploitation of these sources over years. The models have been achieved and generated signals for electronic switches command of proposed both techniques are presented and discussed in this paper.

14 SOLAR ENERGY↗

Multi-region Modeling of Daily Global Solar Radiation with Artificial Intelligence Ensemble

Solar radiation data are crucial for the design and evaluation of solar energy systems, climatic studies, water resources management, estimating crop productivity, etc. As so, for locations where direct measurements are not available, reliable models may be developed to estimate solar radiation from more readily available data. In this study, two artificial intelligence (AI)-based models including artificial neural network and adaptive neuro-fuzzy inference systems, three temperature-based empirical models including Meza–Varas, Hargreaves–Samani, and Chen, and a conventional multi-linear regression (MLR) model were employed for multi-region daily global solar radiation estimation for Iraq. To ensure appropriate selection of input variables, sensitivity analysis was conducted to determine the dominant parameters. Finally, two ensemble approaches, neural average ensemble and simple average ensemble, were applied to improve the performance of the single models. For this purpose, daily meteorological data of maximum temperature (T{sub max}), minimum temperature (T{sub min}), mean temperature (T{sub mean}), relative humidity (R{sub H}), and wind speed (U{sub 2}) were obtained from January 2006 to December 2016 from four major cities in Iraq representing, north, west, south, and east regions. The results revealed that temperatures (T{sub max}, T{sub mean}, T{sub min}) and relative humidity are the dominant parameters. While temperature-based empirical models and MLR model could be employed to achieve reliable results, AI-based models are superior in performance to other models. Also promising improvement in daily global solar radiation modeling could be achieved by model ensemble. The results of this study affirmed that the provided ensemble approaches can increase the performance of single models up to 19.19%, 7.59%, and 16.81% in training, validation, and testing steps, respectively.

58 GEOSCIENCES↗

A novel approach to robust H{sub ∞} integral control for TS fuzzy systems

In this paper, a novel approach to the robust H{sub ∞} integral control for TS fuzzy systems is considered. The control design concept can significantly improve the system stability for such a system. Based on the H{sub ∞} control theory and linear matrix inequality approach, a set of sufficient conditions guarantee the stability of the system and the H{sub ∞} performance. The proposed RHFI controllers are able to work well with the complex nonlinearity and can overcome the effect of approximate rules in the fuzzy system in case of parametric uncertainty existing in the system. This enables the fuzzy system to give appropriate responses with a fewer number of membership functions. Finally, the proposed RHFI controllers are verified through a simulation example, i.e., DFIG wind energy system. The simulated results show that the stability of the system is satisfied and the H{sub ∞} performance is achieved.

97 MATHEMATICS AND COMPUTING↗