Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fuel Cell Stack Block”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Solid Oxide Fuel Cell Systems PVL Line

In July 2010, Stark State College (SSC), received Grant DE-EE0003229 from the U.S. Department of Energy (DOE), Golden Field Office, for the development of the electrical and control systems, and mechanical commissioning of a unique 20kW scale high-pressure, high temperature, natural gas fueled Stack Block Test System (SBTS). SSC worked closely with subcontractor, Rolls-Royce Fuel Cell Systems (US) Inc. (RRFCS) over a 13 month period to successfully complete the project activities. This system will be utilized by RRFCS for pre-commercial technology development and training of SSC student interns. In the longer term, when RRFCS is producing commercial products, SSC will utilize the equipment for workforce training. In addition to DOE Hydrogen, Fuel Cells, and Infrastructure Technologies program funding, RRFCS internal funds, funds from the state of Ohio, and funding from the DOE Solid State Energy Conversion Alliance (SECA) program have been utilized to design, develop and commission this equipment. Construction of the SBTS (mechanical components) was performed under a Grant from the State of Ohio through Ohio's Third Frontier program (Grant TECH 08-053). This Ohio program supported development of a system that uses natural gas as a fuel. Funding was provided under the Department of Energy (DOE) Solid-state Energy Conversion Alliance (SECA) program for modifications required to test on coal synthesis gas. The subject DOE program provided funding for the electrical build, control system development and mechanical commissioning. Performance testing, which includes electrical commissioning, was subsequently performed under the DOE SECA program. Rolls-Royce Fuel Cell Systems is developing a megawatt-scale solid oxide fuel cell (SOFC) stationary power generation system. This system, based on RRFCS proprietary technology, is fueled with natural gas, and operates at elevated pressure. A critical success factor for development of the full scale system is the capability to test fuel cell components at a scale and under conditions that can be accurately extrapolated to full system performance. This requires specially designed equipment that replicates the pressure (up to 6.5 bara), temperature (about 910 C), anode and cathode gas compositions, flows and power generation density of the full scale design. The SBTS fuel cell anode gas is produced through the reaction of pipeline natural gas with a mixture of steam, CO2, and O2 in a catalytic partial oxidation (CPOX) reactor. Production of the fuel cell anode gas in this manner provides the capability to test a fuel cell with varying anode gas compositions ranging from traditional reformed natural gas to a coal-syngas surrogate fuel. Stark State College and RRFCS have a history of collaboration. This is based upon SSCAs commitment to provide students with skills for advanced energy industries, and RRFCS need for a workforce that is skilled in high temperature fuel cell development and testing. A key to this approach is the access of students to unique SOFC test and evaluation equipment. This equipment is designed and developed by RRFCS, with the participation of SSC interns. In the near-term, the equipment will be used by RRFCS for technology development. When this stage is completed, and RRFCS has moved to commercial products, SSC will utilize this equipment for workforce training. The RRFCS fuel cell design is based upon a unique ceramic substrate architecture in which a porous, flat substrate (tube) provides the support structure for a network of solid oxide fuel cells that are electrically connected in series. These tubes are grouped into a {approx}350-tube repeat configuration, called a stack/block. Stack/block testing, performed at system conditions, provides data that can be confidently scaled to full scale performance. This is the basis for the specially designed and developed test equipment that is required for advancing and accelerating the RRFCS SOFC power system development program. All contract DE-EE0003229 objectives were achieved and deliverables completed during the period from March 1, 2010 through March 31, 2011. As a result of program completion, the Stack Block Test System was ready to support installation and electrical operation of a RRFCS solid oxide fuel cell (SOFC) stack block in the second quarter of 2011.

01 COAL, LIGNITE, AND PEAT↗

DE-FE0026098 Final Report - Advanced Materials and Manufacturing Processes for SOFC Power Systems Revision 1

The aim of the project is to qualify an integrated material set and processing solution for selected metallic components of an advanced integrated stack block. As the integrated stack block is the “engine” of the solid oxide fuel cell power system, the project will also support significant cost reductions, increased reliability, and improved performance of the LG Fuel Cell Systems Inc. (“LGFCS”) cell and stack technology to be included in the initial commercial product offering. In the proposed work an integrated material set, and processing solution will be developed using powder metals processing which has been proven to be an enabling technology capable of delivering net or near net shape components, as well as for creating compositions, microstructures, and properties that are otherwise unattainable. Several advanced manufacturing processes will be screened to select one or more that are most advantageous for the selected metallic components when produced at commercial volumes. This work will be accomplished through the integration of metallurgists and processing engineers from Carpenter Technology, with the product design and cost engineers from LGFCS. The expected outcome of the proposed work is an optimized material set and processing solution that will reduce the current cost.

03 NATURAL GAS↗

Next Generation Solid Oxide Fuel Cell Module Development

The overall objective of this project was to develop a transformative Solid Oxide Fuel Cell (SOFC) building block configuration comprised of multi-stack arrays that can be utilized in large-scale power plants. This transformative design signified the benefits of lower performance degradation coupled with improved reliability, low cost, smaller packaging for easier transport and installation, and improved maintenance and field serviceability characteristics. The project goal was to design and fabricate a scalable hot module for housing an array of SOFC stacks and to demonstrate the characteristics of the module gas distribution, insulation and instrumentation, and DC power take-off. The approach was to validate the design of a stack prototype scalable to megawatt (MW) class systems using FuelCell Energy’s Compact SOFC Architecture (CSA) stacks. The scope of work was intended to design, build, and test a compact and low-cost multi-stack sub-module with flexibility to house CSA stacks and scalable to 350 kW which could ultimately be deployed in construction of MW-class systems.

20 FOSSIL-FUELED POWER PLANTS↗

Reliable SOFC Systems

The goal of this U.S. Department of Energy (DOE) sponsored project was to advance the reliability, robustness and endurance of low-cost SOFC technology suitable for ultimate deployment in ≥100 MWe Integrated Gasification Fuel Cell (IGFC) or Natural Gas Fuel Cell (NGFC) systems capable of ≥97% CO2 capture. The ultimate SOFC program goals are ≤ 0.2% per 1000 hours power degradation over a 5-plus year stack life, high-volume (≥ 250 MW/year) stack production cost of ≤$225/kWsystem net AC, and “power block” (exclusive of fuel supply, contaminant removal, and CO2 capture subsystems) capital cost of ≤ 900/kWsystem net AC (in year 2011). To progress towards the ultimate program goals, the specific objectives of this project were to achieve an SOFC stack power degradation rate of ≤1.5% per 1000 hours in a 100 kW (125 kW Peak) Modular Power Block (MPB) stand-alone power system under thermally self-sustained normal operating conditions and to verify the prospects for high volume SOFC stack production cost below the DOE target of ≤ 225/kW. This final technical report summarizes the progress made during the project period of 36 months. Significant progress was made in the areas of cell and stack technology development, Modular Power Block (MPB) development, sub-MW MPB system development, and MW-class SOFC System Development and Costing. The work focused on areas necessary for comprehensive development of an SOFC fuel cell system, including, active cell improvement, contaminant resistance, process engineering, and development of non-repeat module components. Additionally, several custom built balance-of-plant components were designed and fabricated to support the fuel cell system. SOFC cell and stack development focused on improving cell performance and durability. Enhancements were achieved in areas of electrode stability and impurity tolerance. Additionally, several quality control techniques and tools were developed to ensure predictable and repeatable fabrication of SOFC stacks. Module development continued previous development efforts to achieve footprint reduction and higher efficiency by incorporating balance-of-plant functional equipment into the fuel cell containment module. Several improvements were made to prior design. Control and instrumentation hardware was integrated within the module for serviceability and size reduction. The design efforts culminated in a complete SOFC power plant system. The designed plant was constructed and tested at FCE. Stack and system costs were updated, reflecting advances made in this program.

20 FOSSIL-FUELED POWER PLANTS↗

SECA Coal-Based Systems - FuelCell Energy, Inc.

The overall goal of this U.S. Department of Energy (DOE) sponsored project is the development of solid oxide fuel cell (SOFC) cell and stack technology suitable for use in highly-efficient, economically-competitive central generation power plant facilities fueled by coal synthesis gas (syngas). This program incorporates the following supporting objectives: • Reduce SOFC-based electrical power generation system cost to $700 or less (2007 dollars) for a greater than 100 MW Integrated Gasification Fuel Cell (IGFC) power plant, exclusive of coal gasification and CO 2 separation subsystem costs. • Achieve an overall IGFC power plant efficiency of at least 50%, from coal (higher heating value or HHV) to AC power (exclusive of CO 2 compression power requirement). • Reduce the release of CO2 to the environment in an IGFC power plant to no more than 10% of the carbon in the syngas. • Increase SOFC stack reliability to achieve a design life of greater than 40,000 hours. At the inception of the project, the efforts were focused on research, design and testing of prototype planar SOFC power generators for stationary applications. FuelCell Energy, Inc. successfully completed the initial stage of the project by meeting the program metrics, culminating in delivery and testing of a 3 kW system at National Energy Technology Laboratory (NETL). Subsequently, the project was re-aligned into a three phase effort with the main goal to develop SOFC technology for application in coal-fueled power plants with >90% carbon capture. Phase I of the Coal-based efforts focused on cell and stack size scale-up with concurrent enhancement of performance, life, cost, and manufacturing characteristics. Also in Phase I, design and analysis of the baseline (greater than 100 MW) power plant system—including concept identification, system definition, and cost analysis—was conducted. Phase II efforts focused on development of a ≥25 kW SOFC stack tower incorporating multiple stack building blocks of scaled-up cells, suitable for integration into a large-scale fuel cell power module. Activities in Phase II also included the development of the baseline system, factory cost estimate for the baseline plant’s power block, and conceptual design of a natural gas fueled sub-MW system to be used for testing and verification of the fuel cell stacks in a system environment. The specific objective for Phase III was the validation of the performance and robustness of stacks and scaled stack arrays suitable for use in large-scale power generation systems such as an IGFC with reliable, fail-safe operation being of paramount importance. The work culminated in the verification tests of a 60 kW SOFC stack module in a power plant facility. This final technical report summarizes the progress made during the project period. Significant progress was made in the areas of cell and stack technology development, stack module design, sub-scale module tests, Baseline Power Plant system development and Proof-of- Concept Module unit design. The development of this technology will significantly advance the nation’s energy security and independence interests while simultaneously addressing environmental concerns, including greenhouse gas emissions and water usage.

01 COAL, LIGNITE, AND PEAT↗

Analyses of Large Coal-Based SOFCs for High Power Stack Block Development

This report summarizes the numerical modeling and analytical efforts for SOFC stack development performed for the coal-based SOFC program. The stack modeling activities began in 2004, but this report focuses on the most relevant results obtained since August 2008. This includes the latter half of Phase-I and all of Phase-II activities under technical guidance of VPS and FCE. The models developed to predict the thermal-flow-electrochemical behaviors and thermal-mechanical responses of generic planar stacks and towers are described. The effects of cell geometry, fuel gas composition, on-cell reforming, operating conditions, cell performance, seal leak, voltage degradation, boundary conditions, and stack height are studied. The modeling activities to evaluate and achieve technical targets for large stack blocks are described, and results from the latest thermal-fluid-electrochemical and structural models are summarized. Modeling results for stack modifications such as scale-up and component thickness reduction to realize cost reduction are presented. Supporting modeling activities in the areas of cell fabrication and loss of contact are also described.

electrochemistry↗

Novel Composite Materials for SOFC Cathode-Interconnect Contact

This report summarized the research efforts and major conclusions of our University Coal Research Project, which focused on developing a new class of electrically-conductive, Cr-blocking, damage-tolerant Ag-perovksite composite materials for the cathode-interconnect contact of intermediate-temperature solid oxide fuel cell (SOFC) stacks. The Ag evaporation rate increased linearly with air flow rate initially and became constant for the air flow rate {ge} {approx} 1.0 cm {center_dot} s{sup -1}. An activation energy of 280 KJ.mol{sup -1} was obtained for Ag evaporation in both air and Ar+5%H{sub 2}+3%H{sub 2}O. The exposure environment had no measurable influence on the Ag evaporation rate as well as its dependence on the gas flow rate, while different surface morphological features were developed after thermal exposure in the oxidizing and reducing environments. Pure Ag is too volatile at the SOFC operating temperature and its evaporation rate needs to be reduced to facilitate its application as the cathode-interconnect contact. Based on extensive evaporation testing, it was found that none of the alloying additions reduced the evaporation rate of Ag over the long-term exposure, except the noble metals Au, Pt, and Pd; however, these noble elements are too expensive to justify their practical use in contact materials. Furthermore, the addition of La{sub 0.8}Sr{sub 0.2}MnO{sub 3} (LSM) into Ag to form a composite material also did not significantly modify the Ag evaporation rate. The Ag-perovskite composites with the perovskite being either (La{sub 0.6}Sr{sub 0.4})(Co{sub 0.8}Fe{sub 0.2})O{sub 3} (LSCF) or LSM were systematically evaluated as the contact material between the ferritic interconnect alloy Crofer 22 APU and the LSM cathode. The area specific resistances (ASRs) of the test specimens were shown to be highly dependent on the volume percentage and the type of the perovskite present in the composite contact material as well as the amount of thermal cycling that the specimens were subjected to during testing. The Ag-LSCF composite contact materials proved more effective in trapping Cr within the contact material and preventing Cr migration into the cathode than the Ag-LSM composites. Ag-perovskite composite contact materials are promising candidates for use in intermediate-temperature SOFC stacks with ferritic stainless steel interconnects due to their ability to maintain acceptably low ASRs while reducing Cr migration into the cathode material.

01 COAL, LIGNITE, AND PEAT↗

SECA Coal-Based Systems – LGFCS

LGFCS is developing an integrated planar (IP) SOFC technology for mega-watt scale distributed power generation including the potential for use in highly efficient, economically competitive central generation power plant facilities fuel by coal synthesis gas. The overall goal of this project is to demonstrate, through analysis and testing, progress towards adequate stack life and stability in a low-cost solid-oxide fuel cell (SOFC) stack design. The emphasis of the proposed work has been the further understanding of the degradation mechanisms present within the LGFCS SOFC stack and development of the active layers to mitigate such mechanisms for achievement of a lower rate of power degradation. Performance enhancement has been achieved to support cost reduction. Testing is performed at a range of scales from single cells to ~350 kW bundles and ultimately pressurized 15kW blocks in test rigs that are representative of the product system cycle. The block is the representative fuel cell module that forms the building block for the LGFCS SOFC power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DEGRADATION ISSUES IN SOLID OXIDE CELLS DURING HIGH TEMPERATURE ELECTROLYSIS

Idaho National Laboratory (INL) is performing high-temperature electrolysis research to generate hydrogen using solid oxide electrolysis cells (SOECs). The project goals are to address the technical and degradation issues associated with the SOECs. This paper provides a summary of various ongoing INL and INL sponsored activities aimed at addressing SOEC degradation. These activities include stack testing, post-test examination, degradation modeling, and a list of issues that need to be addressed in future. Major degradation issues relating to solid oxide fuel cells (SOFC) are relatively better understood than those for SOECs. Some of the degradation mechanisms in SOFCs include contact problems between adjacent cell components, microstructural deterioration (coarsening) of the porous electrodes, and blocking of the reaction sites within the electrodes. Contact problems include delamination of an electrode from the electrolyte, growth of a poorly (electronically) conducting oxide layer between the metallic interconnect plates and the electrodes, and lack of contact between the interconnect and the electrode. INL’s test results on high temperature electrolysis (HTE) using solid oxide cells do not provide a clear evidence whether different events lead to similar or drastically different electrochemical degradation mechanisms. Post-test examination of the solid oxide electrolysis cells showed that the hydrogen electrode and interconnect get partially oxidized and become non-conductive. This is most likely caused by the hydrogen stream composition and flow rate during cool down. The oxygen electrode side of the stacks seemed to be responsible for the observed degradation due to large areas of electrode delamination. Based on the oxygen electrode appearance, the degradation of these stacks was largely controlled by the oxygen electrode delamination rate. University of Utah (Virkar) has developed a SOEC model based on concepts in local thermodynamic equilibrium in systems otherwise in global thermodynamic non-equilibrium. This model is under continued development. It shows that electronic conduction through the electrolyte, however small, must be taken into account for determining local oxygen chemical potential, within the electrolyte. The chemical potential within the electrolyte may lie out of bounds in relation to values at the electrodes in the electrolyzer mode. Under certain conditions, high pressures can develop in the electrolyte just under the oxygen electrode (anode)/electrolyte interface, leading to electrode delamination. This theory is being further refined and tested by introducing some electronic conduction in the electrolyte.

08 HYDROGEN↗

DEGRADATION ISSUES IN SOLID OXIDE CELLS DURING HIGH TEMPERATURE ELECTROLYSIS

Idaho National Laboratory (INL) is performing high-temperature electrolysis research to generate hydrogen using solid oxide electrolysis cells (SOECs). The project goals are to address the technical and degradation issues associated with the SOECs. This paper provides a summary of various ongoing INL and INL sponsored activities aimed at addressing SOEC degradation. These activities include stack testing, post-test examination, degradation modeling, and a list of issues that need to be addressed in future. Major degradation issues relating to solid oxide fuel cells (SOFC) are relatively better understood than those for SOECs. Some of the degradation mechanisms in SOFCs include contact problems between adjacent cell components, microstructural deterioration (coarsening) of the porous electrodes, and blocking of the reaction sites within the electrodes. Contact problems include delamination of an electrode from the electrolyte, growth of a poorly (electronically) conducting oxide layer between the metallic interconnect plates and the electrodes, and lack of contact between the interconnect and the electrode. INL's test results on high temperature electrolysis (HTE) using solid oxide cells do not provide a clear evidence whether different events lead to similar or drastically different electrochemical degradation mechanisms. Post-test examination of the solid oxide electrolysis cells showed that the hydrogen electrode and interconnect get partially oxidized and become non-conductive. This is most likely caused by the hydrogen stream composition and flow rate during cool down. The oxygen electrode side of the stacks seemed to be responsible for the observed degradation due to large areas of electrode delamination. Based on the oxygen electrode appearance, the degradation of these stacks was largely controlled by the oxygen electrode delamination rate. University of Utah (Virkar) has developed a SOEC model based on concepts in local thermodynamic equilibrium in systems otherwise in global thermodynamic non-equilibrium. This model is under continued development. It shows that electronic conduction through the electrolyte, however small, must be taken into account for determining local oxygen chemical potential, within the electrolyte. The chemical potential within the electrolyte may lie out of bounds in relation to values at the electrodes in the electrolyzer mode. Under certain conditions, high pressures can develop in the electrolyte just under the oxygen electrode (anode)/electrolyte interface, leading to electrode delamination. This theory is being further refined and tested by introducing some electronic conduction in the electrolyte.

08 HYDROGEN↗

Direct FuelCell/Turbine Power Plant

This report summarizes the progress made in development of Direct FuelCell/Turbine (DFC/T{reg_sign}) power plants for generation of clean power at very high efficiencies. The DFC/T system employs an indirectly heated Turbine Generator to supplement fuel cell generated power. The concept extends the high efficiency of the fuel cell by utilizing the fuel cell's byproduct heat in a Brayton cycle. Features of the DFC/T system include: electrical efficiencies of up to 75% on natural gas, minimal emissions, reduced carbon dioxide release to the environment, simplicity in design, direct reforming internal to the fuel cell, and potential cost competitiveness with existing combined cycle power plants. Proof-of-concept tests using a sub-MW-class DFC/T power plant at FuelCell Energy's (FCE) Danbury facility were conducted to validate the feasibility of the concept and to measure its potential for electric power production. A 400 kW-class power plant test facility was designed and retrofitted to conduct the tests. The initial series of tests involved integration of a full-size (250 kW) Direct FuelCell stack with a 30 kW Capstone microturbine. The operational aspects of the hybrid system in relation to the integration of the microturbine with the fuel cell, process flow and thermal balances, and control strategies for power cycling of the system, were investigated. A subsequent series of tests included operation of the sub-MW Direct FuelCell/Turbine power plant with a Capstone C60 microturbine. The C60 microturbine extended the range of operation of the hybrid power plant to higher current densities (higher power) than achieved in initial tests using the 30kW microturbine. The proof-of-concept test results confirmed the stability and controllability of operating a fullsize (250 kW) fuel cell stack in combination with a microturbine. Thermal management of the system was confirmed and power plant operation, using the microturbine as the only source of fresh air supply to the system, was demonstrated. System analyses of 40 MW DFC/T hybrid systems, approaching 75% efficiency on natural gas, were carried out using CHEMCAD simulation software. The analyses included systems for near-term and long-term deployment. A new concept was developed that was based on clusters of one-MW fuel cell modules as the building blocks. The preliminary design of a 40 MW power plant, including the key equipment layout and the site plan, was completed. The process information and operational data from the proof-of-concept tests were used in the design of 40 MW high efficiency DFC/T power plants. A preliminary cost estimate for the 40 MW DFC/T plant was also prepared. Pilot-scale tests of the cascaded fuel cell concept for achieving high fuel utilizations were conducted. The tests demonstrated that the concept has the potential to offer higher power plant efficiency. Alternate stack flow geometries for increased power output and fuel utilization capabilities were also evaluated. Detailed design of the packaged sub-MW DFC/T Alpha Unit was completed, including equipment and piping layouts, instrumentation, electrical, and structural drawings. The lessons learned from the proof-of-concept tests were incorporated in the design of the Alpha Unit. The sub-MW packaged unit was fabricated, including integration of the Direct FuelCell{reg_sign} (DFC{reg_sign}) stack module with the mechanical balance-of-plant and electrical balance-of-plant. Factory acceptance tests of the Alpha DFC/T power plant were conducted at Danbury, CT. The Alpha Unit achieved an unsurpassed electrical efficiency of 58% (LHV natural gas) during the factory tests. The resulting high efficiency in conversion of chemical energy to electricity far exceeded any sub-MW class power generation equipment presently in the market. After successful completion of the factory tests, the unit was shipped to the Billings Clinic in Billings, MT, for field demonstration tests. The DFC/T unit accomplished a major achievement by successfully completing 8000 hours of operation at the Billings site. The Alpha sub-MW DFC/T power plant unit was returned to the factory for post-operation inspection and analysis. The success of the Alpha Unit operation in the field and achievement of the ultra-high efficiency of 58%, triggered the establishment of a MW-scale commercial product design and development program. Design of a 3 MW (nominal rating) DFC/T Power Plant was completed with an electrical efficiency approaching 60+% LHV of natural gas depending on the design and performance of the gas turbine. Development efforts incorporated lessons learned from the Alpha sub-MW DFC/T power plant demonstration, as well as design features from FCE's commercial product offerings, the DFC1500 and DFC3000 MW-class simple cycle power plants. The 3 MW DFC/T power plant is anticipated to be a superb alternative for large distributed generation applications in locations with high cost-of-electricity.

03 NATURAL GAS↗

Comparison between Flownex and Corona thermal-hydraulic models for a single HTR prismatic fuel assembly - 18544

Computational tools and methodologies that can perform thermal-hydraulic analyses to reasonably predict the temperature distribution for the whole core of HTRs are useful for operational and safety analyses. In this paper, Flownex (a system code based on a one-dimensional thermal-fluid network methodology) and CORONA (Core Reliable Optimization and thermo-fluid Network Analysis) thermal-hydraulic models and results for a vertically stacked single fuel assembly will be compared. In Flownex, a basic unit cell containing part of the graphite and the associated fuel elements and coolant channels was developed. CORONA uses a basic unit cell concept for generating computational grids using several types of basic unit cells to model the heat transfer through the hexagonal blocks and a 1-D formulation to model the flow through the coolant channels. In CORONA, computational grids are generated using a combination of pre-generated mesh cells. The coolant channels and fuel rods are modelled explicitly. Flownex in contrast, models fuel and coolant channels implicitly by defining representative coolant channels, fuel rods and coated particle layers associated with each unit cell. Flownex can therefore model temperatures at coated particle level and also through each graphite block. The computational mesh employed by Flownex is much coarser than the mesh employed by CORONA. In both models, the helium gap between the fuel compact and the graphite block is modelled as stagnant. Flownex results were found to be of the same order of magnitude as those obtained using CORONA. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaporator Development for an Evaporative Heat Pipe System

As fossil fuel resources continue to deplete, research for alternate power sources continues to develop. One of these alternate technologies is fuel cells. They are a practical fuel source able to provide significant amounts of power for applications from laptops to automobiles and their only byproduct is water. However, although this technology is over a century old and NASA has been working with it since the early 1960 s there is still room for improvement. The research I am involved in at NASA's Glenn Research Center is focusing on what is called a regenerative fuel cell system. The unique characteristic of this type of system is that it used an outside power source to create electrolysis of the water it produces and it then reuses the hydrogen and oxygen to continue producing power. The advantage of this type of system is that, for example, on space missions it can use solar power to recharge its gas supplies between periods when the object being orbited blocks out the sun. This particular system however is far from completion. This is because of the many components that are required to make up a fuel cell that need to be tested individually. The specific part of the system that is being worked on this summer of 2004 is the cooling system. The fuel cell stack, that is the part that actually creates the power, also produces a lot of heat. When not properly cooled, it has been known to cause fires which, needless to say are not conducive to the type of power that is trying to be created. In order to cool the fuel cell stack in this system we are developing a heat pipe cooling system. One of the main components of a heat pipe cooling system is what is known as the evaporator, and that is what happens to be the part of the system we are developing this summer. In most heat pipe systems the evaporator is a tube in which the working fluid is cooled and then re-circulated through the system to absorb more heat energy from the fuel cell stack. For this system, instead of a tube, the evaporator is made up of a stack-up of screen material and absorbent membranes inside a stainless steel shell and held together by a film adhesive and epoxy. There is an initial design for this flat plate evaporator, however is has not yet been made. The components of the stack-up are known, so all testing is focused on how it will all go together. This includes finding an appropriate epoxy to make the evaporator conductive all the way through and finding a way to hold the required tight tolerances as the stainless steel outer shell is put together. By doing the tests on smaller samples of the stack-ups and then testing the fill size component, the final flat plate evaporator will reach its final design so that research can continue on other parts of the regenerative fue1 cell system, and another step in the improvement of fue1 cell technology can be made.

Peters, Leigh C.↗

Tailoring Fe-Base Alloys for Intermediate Temperature SOFC Interconnect Application

This report summarized the research efforts and major conclusions for our SECA Phase I and II project focused on Cr-free or low Cr Fe-Ni based alloy development for intermediate temperature solid oxide fuel cell (SOFC) interconnect application. Electrical conductivity measurement on bulk (Fe,Ni){sub 3}O{sub 4} coupons indicated that this spinel phase possessed a higher electrical conductivity than Cr{sub 1.5}Mn{sub 1.5}O{sub 4} spinel and Cr{sub 2}O{sub 3}, which was consistent with the low area specific resistance (ASR) of the oxide scale formed on these Fe-Ni based alloys. For Cr-free Fe-Ni binary alloys, although the increase in Ni content in the alloys improved the oxidation resistance, and the Fe-Ni binary alloys exhibited adequate CTE and oxide scale ASR, their oxidation resistance needs to be further improved. Systematic alloy design efforts have led to the identification of one low-Cr (6wt.%) Fe-Ni-Co based alloy which formed a protective, electrically-conductive Cr{sub 2}O{sub 3} inner layer underneath a Cr-free, highly conductive spinel outer layer. This low-Cr, Fe-Ni-Co alloy has demonstrated a good CTE match with other cell components; high oxidation resistance comparable to that of Crofer; low oxide scale ASR with the formation of electrically-insulating phases in the oxide scale; no scale spallation during thermal cycling; adequate compatibility with cathode materials; and comparable mechanical properties with Crofer. The existence of the Cr-free (Fe,Co,Ni){sub 3}O{sub 4} outer layer effectively reduced the Cr evaporation and in transpiration testing resulted in a 6-fold decrease in Cr evaporation as compared to a state-of-the-art ferritic interconnect alloy. In-cell testing using an anode supported cell with a configuration of Alloy/Pt/LSM/YSZ/Ni+YSZ indicates that the formation of the Cr-free spinel layer via thermal oxidation was effective in blocking the Cr migration and thus improving the cell performance stability. Electroplating of the Fe-Ni-Co alloys as precursor to synthesize a protective spinel layer on commercial ferritic steels has been initiated to facilitate the utilization of the Cr-free spinel as a surface seal to block Cr evaporation. It is suggested that low-cost Fe-Ni-Co alloy coating on commercial ferritic steels might be the best approach to completely eliminate the Cr poisoning problem in SOFC stacks, while maintaining the relatively low overall cost of the interconnect component.

30 DIRECT ENERGY CONVERSION↗

SECA Coal-Based Systems - LGFCS

LGFCS is developing an integrated planar (IP) SOFC technology for mega-watt scale power generation including the potential for use in highly efficient, economically competitive central generation power plant facilities fuel by coal synthesis gas. This Department of Energy Solid-State Energy Conversion Alliance (SECA) program has been aimed at achieving further cell and stack technical advancements and assessing the readiness of the LGFCS SOFC stack technology to be scaled to larger-scale demonstrations as a path to commercialization. Significant progress was achieved in reducing to practice a higher performance and lower cost cell technology, identifying and overcoming degradation mechanisms, confirming the structural capability of the porous substrate for reliability, maturing the strip design for improved flow to allow high fuel utilization operation while minimizing degradation mechanisms and obtaining full scale block testing at 19 kW under representative conditions for eventual product and meeting SECA degradation metrics. The SECA program has played a key role within the overall LGFCS development program in setting the foundation of the technology to justify the progression of the technology to the next level of technology readiness testing.

Goettler, Richard↗

SPUTTERED THIN FILMS FOR VERY HIGH POWER, EFFICIENT, AND LOW-COST COMMERCIAL SOFCS

The aim of this project was to leverage the low area specific resistance (ASR) of Redox’s GDC electrolyte-based cell architecture and increase solid oxide fuel cell (SOFC) efficiency (i.e., open circuit voltage, or OCV) without significantly increasing cell resistance. The key to achieving the increased SOFC efficiency is the introduction of a thin sputtered yttria stabilized zirconia (YSZ) electron-blocking layer and a thin sputtered gadolinia doped ceria (GDC) barrier layer on top of the half-cell substrate (i.e., anode and GDC electrolyte). A key initial effort of the project was to improve the quality of the half-cell substrate surface so that any remaining defects were significantly smaller than the desired film thickness. During lab-scale trials, we had to overcome challenges with film cracking during post-sputtering treatments (e.g., thermal anneals) as well as damage to the sputtering targets. After the initial lab-scale trials, the focus shifted toward the use of commercial scale sputtering equipment with a sputtering equipment manufacturer in the microelectronics industry. Using the commercial sputtering equipment, we deposited films with different variations of power, PO2, sputtering time, platen speed, etc. We then determined the combinations of sputtering conditions and post-sputtering treatments that yielded high-quality films without cracks or other significant defects. While thin films were deposited on cells as large as 10 cm by 10 cm, the processing was optimized using 4 cm by 4 cm cells. Cell performance was evaluated in stainless-steel test fixtures between 500 °C and 700 °C with hydrogen fuel fed to the anode and air fed to the cathode. Extensive studies allowed us to determine that modified cathode and cathode contact firing processes were required to achieve theoretical OCV. Moreover, use of the new firing processes resulted in the need for a modified cathode contact to achieve a low ASR. In summary, the project demonstrated the performance of high OCV (1.13 V at 650 °C) from sputtered layers and a low ASR (~0.25 Ohms-cm2 at 650 °C) resulting from a modification of cathode/contact processing and the introduction of alternative contact layers that are sufficient to yield a Gen-1 cell with a maximum power density of approximately 1.2 W/cm2. At an operating voltage of 0.74 V, this would yield a cell power density of ~1.1 W/cm2. While not utilized in this project, a Redox Gen-2 cell has a catalyst-infiltrated porous anode that reduces the ASR by more than 50% from that of the Gen-1 cells used in this project. Therefore, if the sputtered YSZ electron-blocking layer and GDC barrier layer are added to a Gen-2 half cell with a similar increase in OCV to the theoretical value of ~1.13 V at 650 °C, and if the same improvement in ASR (from that demonstrated in this project) is achieved when using the Gen-2 half-cell architecture as a sputtered cell substrate, then the power density at 0.74 Vop could be as high as ~2.6 W/cm2. The impact of such power density gains, while still maintaining high cell efficiency, and thus high system efficiency, is a dramatic decrease in system cost because the stack represents ~30-40% of the SOFC system cost.

01 COAL, LIGNITE, AND PEAT↗

DE-FE0031180 Final Report - LGFCS Prototype System Testing - R0

In the project, LGFCS assembled and tested its modular SOFC Power System that incorporates all critical technology improvements identified for its “product-like” demonstration. This product demonstrator is expected to meet customer and LGFCS performance expectations for operation, availability, durability and serviceability. The principal technology improvements are aimed at increasing the fuel cell power output and reducing the stack degradation rate. Improvements were also made for added system robustness and increased reliability. The objective of this program is to test a 250kWe thermally self-sustaining modular solid oxide fuel cell (SOFC) Power System for a minimum of 5,000 hours while advancing this commercial prototype product demonstrator to a Technical Readiness Level (TRL) 7. The SOFC system was tested on a site provided by Stark State College in North Canton, Ohio. System performance and degradation as well as cost estimates were compared to established SOFC Program performance metrics to assess progress. The major achievements were to assemble, and QA qualify 70 fuel cell strips for 12 integrated blocks into a fuel cell vessel and install it into a generator module with the fuel and power electronics modules on the test site. Performance to date included over 1800 hours on load at 250 KW-AC to the grid with a DC efficiency of 61% and AC efficiency of 55%. Power degradation was less than 0.4% per 1000 hours and NOx emissions met standards. The LGFCS SOFC Prototype System (GEN0) was demonstrated in an operational environment and therefore achieving Technical Readiness Level 7. The work presented here represents the efforts of all the employees of LG Fuel Cell Systems. Their dedication and hard work made GEN0 possible and successful.

03 NATURAL GAS↗

LGFCS Prototype System Testing (Final Report)

In the project, LGFCS assembled and tested its modular SOFC Power System that incorporates all critical technology improvements identified for its “product-like” demonstration. This product demonstrator is expected to meet customer and LGFCS performance expectations for operation, availability, durability and serviceability. The principal technology improvements are aimed at increasing the fuel cell power output and reducing the stack degradation rate. Improvements were also made for added system robustness and increased reliability. The objective of this program is to test a 250kWe thermally self-sustaining modular solid oxide fuel cell (SOFC) Power System for a minimum of 5,000 hours while advancing this commercial prototype product demonstrator to a Technical Readiness Level (TRL) 7. The SOFC system was tested on a site provided by Stark State College in North Canton, Ohio. System performance and degradation as well as cost estimates were compared to established SOFC Program performance metrics to assess progress. The major achievements were to assemble, and QA qualify 70 fuel cell strips for 12 integrated blocks into a fuel cell vessel and install it into a generator module with the fuel and power electronics modules on the test site. Performance to date included over 1800 hours on load at 250 KWAC to the grid with a DC efficiency of 61% and AC efficiency of 55%. Power degradation was less than 0.4% per 1000 hours and NOx emissions met standards. The LGFCS SOFC Prototype System (GEN0) was demonstrated in an operational environment and therefore achieving Technical Readiness Level 7. The work presented here represents the efforts of all the employees of LG Fuel Cell Systems. Their dedication and hard work made GEN0 possible and successful.

03 NATURAL GAS↗