Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Frisch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance Study of Virtual Frisch Grid CdZnTeSe Detectors

Nuclear detectors for x-ray and gamma-ray spectroscopy and imaging are a vital tool in many homeland security, medical imaging, astrophysics and other applications. Most of these applications require room-temperature operation due to the operational constraints imposed by a cryogenic cooling system. CdZnTe (CZT) has been the main material with the desired detection properties, and CZT crystals have been used commercially for three decades. However, CdZnTe still suffers from long-standing issues of high densities of performance-limiting intrinsic defects such as Te inclusions and networks of dislocation walls (sub-grain boundaries). A recently invented new quaternary material CdZnTeSe showed excellent material properties for radiation detection. The material was found to be free from dislocation networks, possess reduced Te inclusions, and have better compositional homogeneity. Virtual Frisch grid detectors were fabricated from crystals taken from a CdZnTeSe ingot that was grown by the traveling heater method. The detectors were fabricated from an as-grown ingot, bypassing the post-growth annealing process commonly practiced for industrial-grade CZT. The performances of the detectors were studied with different Frisch grid lengths using an amplifier shaping time ranging from 1–6 µs. The detectors showed high-quality spectroscopic performance with an as-measured energy resolution of ~1.1% at 662 keV for an optimum Frisch grid length of 3 mm. The charge collection was observed to enhance for longer Frisch grids.

47 OTHER INSTRUMENTATION↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

3x3 array module of 8×8×32 mm 3 position-sensitive virtual frisch-grid CdZnTe detectors for imaging and spectroscopy of cosmic gamma-rays

Here, we evaluated the performance of the 3x3 array of 32-mm long position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors read out by the IDEAS GDS-100 data acquisition system. The array is a mechanically solid module designed for integration into a large effective area gamma-ray telescope proposed for imaging and spectroscopy of cosmic gamma-rays. The array employs the bar-shaped 8x8x32 mm 3 CZT crystals which recently became available from Redlen Technologies, Inc. and Kromek-eV Group PLC at affordable costs. The waveform sampling IDE3421 application-specific integrated circuit (ASIC), developed by the University of Michigan and IDEAS for CZT pixel detectors, was adapted to capture the signals from the array's VFG detectors. We showed good spectral performance of the Redlen detectors with an energy resolution of <1% FWHM at 662 keV and slightly poorer performance of the Kromek-eV detectors with a resolution of <2% measured at a reduced temperature of 13 °C. By testing the same detectors as single devices using hybrid charge-sensitive preamplifiers, we demonstrated improved energy resolutions at a normal temperature of ~25°C: <1% and 1.3-1.7%, respectively. However, the Kromek-eV detectors did not perform as well as the Redlen ones. We explained this by the space charge formation (polarization) decreasing the electric field and the electron drift times. The polarization was likely caused by the high injections of holes from the anode contacts. The absence of polarization in Redlen detectors suggested that the quality of the contacts might have played a role in this case.

47 OTHER INSTRUMENTATION↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

High-Energy 3D Calorimeter for Use in Gamma-Ray Astronomy Based on Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors

We will present a concept for a calorimeter based on a novel approach of 3D position-sensitive virtual Frisch-grid CdZnTe (hereafter CZT) detectors. This calorimeter aims to measure photons with energies from approximately 100 keV to 20 - 50 MeV . The expected energy resolution at 662 keV is better than 1% FWHM, and the photon interaction position-measurement accuracy is better than 1 mm in all 3 dimensions. Each CZT bar is a rectangular prism with typical cross-section from 5 x 5 to 7 x 7 mm2 and length of 2 - 4 cm. The bars are arranged in modules of 4 x 4 bars, and the modules themselves can be assembled into a larger array. The 3D virtual voxel approach solves a long-standing problem with CZT detectors associated with material imperfections that limit the performance and usefulness of relatively thick detectors (i.e., greater than 1 cm). Also, it allows us to use the standard (unselected) grade crystals, while achieving the energy resolution of the premium detectors and thus substantially reducing the cost of the instrument. Such a calorimeter can be successfully used in space telescopes that use Compton scattering of gamma rays, such as AMEGO, serving as part of its calorimeter and providing the position and energy measurement for Compton-scattered photons (like a focal plane detector in a Compton camera). Also, it could provide suitable energy resolution to allow for spectroscopic measurements of gamma ray lines from nuclear decays.

Moiseev, A.↗

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

The Chemical Composition and Gas-to-Dust Mass Ratio of Nearby Interstellar Matter

We use recent results on interstellar gas toward nearby stars and interstellar by-products within the solar system to select among the equilibrium radiative transfer models of the nearest interstellar material presented in Slavin & Frisch. For the assumption that O/H - 400 parts per million, models 2 and 8 are found to yield good fits to available data on interstellar material inside and outside of the heliosphere, with the exception of the Ne abundance in the pickup ion and anomalous cosmic-ray populations. For these models, the interstellar medium (ISM) at the entry point to the heliosphere has n(H(sup 0)) = 0.202-0.208/cu cm, n(He(sup 0) = 0.0137-0.0152/cu cm, and ionizations X(H) = 0.29-0.30, X(He) = 0.47-0.51. These best models suggest that the chemical composition of the nearby ISM is approx.60%-70% subsolar if S is undepleted. Both H(0) and H(+) need to be included when evaluating abundances of ions found in warm diffuse clouds. Models 2 and 8 yield an H filtration factor of approx.0.46. Gas-to-dust mass ratios for the ISM toward epsilon CMa are R(sub gd) = 178-183 for solar abundances of Holweger or R(sub gd) = 611-657 for an interstellar abundance standard 70% solar. Direct observations of dust grains in the solar system by Ulysses and Galileo yield R(sub gd) appr0x. 115 for models 2 and 8, supporting earlier results (Frisch and coworkers). If the local ISM abundances are subsolar, then gas and dust are decoupled over small spatial scales. The inferred variation in R(sub gd) over parsec length scales is consistent with the fact that the ISM near the Sun is part of a dynamically active cluster of cloudlets flowing away from the Sco-Cen association. Observations toward stars within approx.500 pc show that R(sub gd) correlates with the percentage of the dust mass that is carried by iron, suggesting that an Fe-rich grain core (by mass) remains after grain destruction. Evidently large dust grains (>10(exp -13) g) and small dust grains (<10(exp -13) g) are not well mixed over parsec length spatial scales in the ISM. It also appears that very small C-dominated dust grains have been destroyed in the ISM within several parsecs of the Sun, since C appears to be essentially undepleted. However, if gas-dust coupling breaks down over the cloud lifetime, the missing mass arguments applied here to determine R(sub gd) and dust grain mineralogy are not appropriate.

Frisch, Priscilla C.↗

The Effect of the Weight Scheme on DFT Vibrational Frequencies

All-electron B3LYP harmonic frequencies of Ge2H5 and Ge2H6 are computed for several choices of grid and using both the Becke and the Stratmann, Scuseria, and Frisch atomic partition functions (weight scheme). For large grids, the results are independent of the weighting scheme. The lowest frequency mode is much more stable with respect to the number of grid points when the Stratmann, Scuseria, and Frisch weights are used.

Bauschlicher, Charles↗

Using 3D position sensitivity to reveal response non-uniformities in CdZnTe, TlBr, and CsPbBr 3 detectors

Position sensitivity enables the correction of response non-uniformities in room-temperature semiconductor detectors caused by crystal defects and other factors. It can also be used to pinpoint the exact location of crystal defects responsible for the response variations. This work describes a technique for revealing and visualizing the detector regions affecting the charge collection efficiency in CdZnTe (CZT), TlBr, and CsPbBr 3 detectors configured as position-sensitive virtual Frisch-grid (VFG) devices. The technique correlates the photopeak events in energy spectra with their spatial distributions inside the detectors using the position information. By selecting the events from narrow energy intervals within a photopeak, we can visualize the detector volumes with particular charge collection efficiencies, which, in turn, correlate with the locations of electrode and crystal defects. Here, we demonstrate this technique in several examples. Columnar structures in the volume plots (position distribution maps) are consistent with signal losses near or at the anode in selected samples of CZT and TlBr. Structures exhibiting a distinct depth dependence are consistent with grain boundaries or other crystal defects.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Optical Observations of Nearby Interstellar Gas

Observations indicated that a cloud with a heliocentric velocity of approximately -28 km/s and a hydrogen column density that possibly could be on the order of, or greater than, 5 x 10 to the 19 power/square cm is located within the nearest 50 to 80 parsecs in the direction of Ophiuchus. This is a surprisingly large column density of material for this distance range. The patchy nature of the absorption from the cloud indicates that it may not be a feature with uniform properties, but rather one with small scale structure which includes local enhancements in the column density. This cloud is probably associated with the interstellar cloud at about the same velocity in front of the 20 parsec distant star alpha Oph (Frisch 1981, Crutcher 1982), and the weak interstellar polarization found in stars as near as 35 parsecs in this general region (Tinbergen 1982). These data also indicate that some portion of the -14 km/s cloud also must lie within the 100 parsec region. Similar observations of both Na1 and Ca2 interstellar absorption features were performed in other lines of sight. Similar interstellar absorption features were found in a dozen stars between 20 and 100 parsecs of the Sun.

Frisch, P. C.↗

Instrumentation for correlated prompt n – γ emission studies in coincidence with fission fragments

Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical Assemblies: Dragon Burst Assembly and Solution Assemblies

This work reviews the historical literature associated with the Dragon experiment and water boiler reactors operated at Los Alamos during the Manhattan Project. Frisch’s invited talk given at the American Nuclear Society’s Fast Burst Reactor Conference held at the University of New Mexico in Albuquerque, New Mexico, in 1969 is quoted. From the literature review, basic models for the Dragon experiment and for a water boiler–type assembly (aqueous homogeneous reactor) were created that can be used for conducting multiphysics simulations for criticality excursion studies. This methodology utilizes the coupled neutronic-hydrodynamic method to perform a time-dependent dynamic simulation of a criticality excursion. MCNP® was utilized to calculate important nuclear kinetic parameters that were incorporated into the models. Simulation results compare reasonably well with historic data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Fission with Exotic Nuclei (Abbreviated Report)

Nuclear fission is a key mechanism involved in the synthesis of heavy elements in the Cosmos and is the primary explanation for the stability of superheavy elements. Nevertheless, our knowledge of fission remains extremely fragmented. Most experiments have been conducted only on a tiny number of stable actinide nuclei and are often incomplete, leading to gaps in our basic understanding of the process. For many radioactive isotopes, basic fission data such as the charge or mass distribution of the fragments is unknown. These gaps cannot always be filled by simulation alone. Common fission models contain too many free parameters and lack predictive power. In contrast, the fundamental theory of fission under development at LLNL is much more predictive, but its current computational cost is too high to be used extensively for data evaluations. A unique window of opportunity to resolve these limitations has recently opened: the U.S. nuclear science community is ramping up major experimental programs at the Facility for Rare Isotope Beams (FRIB, the DOE flagship facility in low-energy nuclear science), and techniques from machine learning have shown great potential to simplify the use of a fundamental, quantum-mechanical theory of fission. This project has two components. On the experimental side, we acquired and deployed at the HIGS facility a new dual Frisch-Grid ionization chamber to measure correlated fragment-mass, kinetic energy, and angular distributions of fission fragments from induced fission. This new device was used to perform measurements of charge, mass and total kinetic energy of fission fragments in the photofission of 238 U and eight gamma-ray beam energies between 6.2 and 13 MeV, which allowed extracting high-precision independent yields for this reaction. The device was also used to perform measurements of the same quantities in the neutron-induced fission of 234 U with monoenergetic beams of energy between 5 and 8 MeV. In parallel, we collaborated with a team at Commissariat à l’énergie atomique et aux énergies alternatives (CEA) to perform a series of measurements of fission yields in inverse kinematics for the two isotopes of 236 U and 240 Pu. The experiment took place at the Grand Accélérateur National d’Ions Lourds in France in June 2023. The deployment of the VAMOS spectrometer with a new array called PISTA allowed determining the excitation energy of the fissioning system within 1 Mega-electronvolts. The second component of the project involved using deep neural networks to build fast and reliable emulators of our current fission models. In an invited paper published in Frontier in Physics, we showed that autoencoders could successfully compress nuclear wavefunctions in nuclear density functional theory. We achieved a dimensionality reduction of the order of two orders of magnitude while keeping the error in the total energy to less than 0.01%. In a second paper submitted to Physical Review Letters in June 2023 with our collaborators at CEA, we showed that variational autoencoders can learn the collective degrees of freedom driving the fission process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗