Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fresnel zone plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Contrast optimization of Fresnel zone plate imaging

Fresnel zone plates (FZPs) are circular diffractive elements that operate as a lens for x-rays. They have gained interest in the field of laser-plasma physics due to their ability to achieve higher spatial resolution than pinholes. Their design and implementation are complicated by the fact that a significant amount of the x-rays passing through the FZP will not diffract (zeroth order) and present a background to the measurement. This background can be large and inhomogeneous depending on the geometric setup of the experiment. Furthermore, we present calculations of the diffracted (first order) and un-diffracted (zeroth order) flux profiles, which makes it possible to optimize the contrast between the first order imaging rays and the zeroth order background. Calculations for the implementation of a central block in the FZP, designed to block the zeroth from the entire field of view, are also presented.

47 OTHER INSTRUMENTATION↗

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility

The study of Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate the potential of Fresnel zone plates (FZPs) to achieve resolution that would unlock such studies. FZPs are circular aperiodic gratings that use diffraction to focus x rays and produce an image with high spatial resolution. Taking into account the NIF’s challenging environment, we have designed a specific array of five FZPs for a zinc backlighter to take a radiograph of a target with 9 keV x rays. We measured a mean resolution for the FZP of 1.9µm±0.5µm and a ±1mm depth of focus at an x-ray calibration facility as well as a 2.3µm±0.4µm resolution on a resolution wire mesh shot on the NIF. We also performed an in-depth analysis of the image quality to assess the capability to resolve the small features present in RT and RM instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray imaging of Rayleigh–Taylor instabilities using Fresnel zone plate at the National Ignition Facility

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 μm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 μm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh–Taylor instabilities with a measured resolution of under 3 μm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

Do, A. (ORCID:0000000174372147)↗

Effect of tilt on circular zone plate performance

Fresnel zone plates are frequently used as focusing and imaging optics in x-ray microscopy, as they provide the ease of use of normal incidence optics. We consider here the effects of tilt misalignment on their optical performance, both in the thin optics limit and in the case of zone plates that are sufficiently thick so that volume diffraction effects come into play. Using multislice propagation, we show that simple analytical models describe the tilt sensitivity of thin zone plates and the thickness at which volume diffraction must be considered, and examine numerically the performance of example zone plates for soft x-ray focusing at 0.5 keV and hard x-ray focusing at 10 keV.

47 OTHER INSTRUMENTATION↗

Spectrally selective modulation of terahertz radiation beams

We report the results of an experimental study on the focusing of broadband terahertz (THz) radiation using lenses and Fresnel zone plates. The obtained data are compared with the results of numerical simulations. It is shown that the use of lenses for focusing THz radiation can lead to the appearance of a ring structure in the spatial distributions of its intensity. The use of Fresnel zone plates allows the spatial distribution of the THz radiation intensity to be varied at selected frequencies of the spectrum. (terahertz radiation)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An experimental and computational study of thin-layer Rayleigh–Taylor instability development during deceleration with and without an externally applied magnetic field

The importance of mitigating the Rayleigh–Taylor instability (RTI) in inertial confinement fusion (ICF) is critical to successfully achieve high gain fusion yield. Consequently, understanding the seed mechanisms of RTI and the potential evolution of RTI in ICF relevant conditions is crucial. Single feature perturbations consistently demonstrate non-linear RTI evolution, for which an experimental platform on OMEGA-EP is developed. Manufacturing defects introduced into the target design require exploration of unanticipated changes to RTI development and an identification of targets that will still render quantifiable physics results. Consequently, it is presented that the inherent 3D nature of experimental targets necessitates 3D modeling for accurate design work and predictive modeling of experimental targets, especially when high resolution imaging diagnostics, like Fresnel Zone Plates, are utilized. A study of the morphology of the RTI evolution due to changing initial conditions and the presence of an externally applied magnetic field are also explored. Experimental data show thin-layer RTI morphology comparable to resistive magneto hydrodynamic 3D results. A discussion on the impacts of an externally applied magnetic field makes the case for continued efforts to observe a magnetic field's impact on RTI morphology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a true single line of sight 3D hot-spot imaging for the National Ignition Facility

High resolution 3D self-emission x-ray imaging during inertial confinement fusion capsule implosion enables the measurement of the shape of the hotspot. While current 3D imaging capabilities use multiple lines of sight to perform image reconstruction, it would be highly desirable to use only one line of sight, as this would significantly reduce the number of windows in the target hohlraum and decrease their impacts on implosion symmetry. Such a goal is achievable using the zone plate coded imaging technique developed by N. M. Ceglio [Proc. SPIE 0106, 55-62 (1977)]. It consists of fielding a visible light Fresnel zone plate on shot to record a shadowgraph. Here, the image can then be reconstructed either by printing the shadowgraph on a transparent film and shining a suitable wavelength light through it or by numerical reconstruction. A new approach using numerical reconstruction is presented, and it relaxes the constraint by an order of magnitude on the optic design, thus enabling an easier fabrication process, as it allows a scaling-up of the optic dimensions. The design, fabrication process, and testing with an x-ray source of a prototype is presented. The reconstruction of an ~14.5 × 17 μm 2 broadband x-ray source was successful and shows that the performances are in line with expectation with an at least 5 mm axial resolution.

47 OTHER INSTRUMENTATION↗

InAs Terahertz Metalens Emitter for Focused Terahertz Beam Generation

Metasurfaces have opened doors to combining multiple photonic functionalities in a single compact device. In particular, the ability to generate short terahertz (THz) pulses with precise wavefront engineering in a single THz metasurface redefined the role metasurfaces can play in THz systems. Here, an InAs metalens emitter which generates and focuses a THz pulse beam is demonstrated using a 130 nm thick InAs metasurface designed as a binary‐phase Fresnel zone plate. The THz beam is focused to a spot of ≈430 μm at 1 THz with a short focal length of 5 mm and large numerical aperture of 0.5. Nanoscale InAs Mie resonators comprising the metasurface enable THz generation with an amplitude as high as 20 times compared to plasmonic THz emitters and several times compared to a 1 mm thick ZnTe crystal. This InAs metasurface emitter provides a new paradigm for designing THz imaging, spectroscopy, and communication systems, where THz beam generation and shaping are performed with a single device without compromising the generation efficiency, while eliminating losses and avoiding limitations of phase matching of conventional nonlinear optics approaches.

47 OTHER INSTRUMENTATION↗

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-photon polymerization printed lattices as support structures in multi-shell ICF targets: Platform development and initial assessment

Recent interest in fielding direct drive multi-shell targets on the NIF [K. Molvig et al., Phys. Rev. Lett. 116, 255003 (2016) and S. X. Hu et al., Phys. Rev. E 100, 063204 (2019)] has highlighted the need for a low density structure to support the inner shell(s) and to avoid energy loss in the acceleration and collision process. We have developed a two-shell platform to evaluate the use of low density two-photon polymerization (2PP) printed lattices as a support structure between the shells. Here, 2PP structures are an attractive option because they can be produced at densities as low as 5 mg/cc, which is ideal for multi-shell targets, and their 3D structure can be tailored to the user's needs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High spatial resolution and contrast radiography of hydrodynamic instabilities at the National Ignition Facility

In this work, we are developing techniques for studying the Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high-energy-densities at the National Ignition Facility (NIF). In particular, through the improvement of experimental imaging quality, we are progressing toward the study of the turbulent regime of the mixing regions in capsule implosion experiments for inertial confinement fusion, which requires few micrometers resolution. Using 60 NIF beams, a solid shock tube is driven launching a shock wave that crosses the interface between a dense and a light material pre-machined in the target to obtain sinusoidal ripples, which results in RM and RT instabilities that are imaged using the NIF Crystal Backlighter Imager. High-quality images were obtained with a mean resolution of 7 μm and improved contrast. While the obtained resolution does not allow the observation of the smallest scale of the “turbulent” energy spectrum, the generated image encompasses 63% of the total flow energy, a 50% improvement over previous studies, which is observed for the first time a roll-up feature in a high energy density-type RT experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Element-specific first order reversal curves measured by magnetic transmission x-ray microscopy

The first-order reversal curve (FORC) method is a macroscopic measurement technique that can be used to extract quantitative and microscopic properties of hysteretic systems. Using magnetic transmission x-ray microscopy (MTXM), local element-specific FORC measurements are performed on a 20 nm thick film of CoTb. The FORCs measured with microscopy reveal a step-by-step domain evolution under the magnetic field cycling protocol and provide a direct visualization of the mechanistic interpretation of FORC diagrams. They are compared with magnetometry FORCs and show good quantitative agreement. Furthermore, the high spatial resolution and element-specific sensitivity of MTXM provide new capabilities to measure FORCs in small regions or specific phases within multicomponent systems, including buried layers in heterostructures. The ability to perform FORCs on very small features is demonstrated with the MTXM-FORC measurement of a rectangular microstructure with vortex-like Landau structures. This work demonstrates the confluence of two uniquely powerful techniques to achieve quantitative insight into nanoscale magnetic behavior.

36 MATERIALS SCIENCE↗

A platform to measure isentropes from proton-heated warm dense matter on short pulse laser facilities

We describe the development of an experimental platform that measures the release isentrope of materials heated isochorically to temperatures of a few electron volts, using short-pulse laser-produced protons to heat the sample and long-pulse laser-produced x rays to perform streaked x-ray radiography. The density profiles derived from the radiography data are integrated to generate pressure–density isentropes, independent of prior knowledge of the equation of state of the sample material. In order to understand the sensitivities of isentrope extraction from radiography data, we analyze synthetic radiographs generated by a radiation hydrodynamics code. Noise reduction and high spatial resolution are critical for isentrope reconstruction, as demonstrated by the analysis of a proof-of-principle shot day on the OMEGA-EP facility. In conclusion, the data demonstrate the feasibility of the platform for characterizing isentropes, and we discuss the necessary improvements to enhance precision in differentiating between equation-of-state models.

Equations of state↗