Fracture‐Resistant and Thermally Insulating Ultrahigh‐Temperature Carbide Foams

Dense ultrahigh‐temperature ceramics (UHTCs) carbides are recognized as potential materials for thermal protection systems (TPS) owing to properties beyond existing structural materials’ capabilities. Recent advances in UHTCs have enabled the development of multiscale porous microstructures. Herein, it is highlighted that the porosity in UHTCs are no longer treated as a defect but as a functional property specifically tailored for thermal insulation. It is a promising solution to design and fabricate bulk UHTC foams via a freeze‐drying (FD) approach followed by calibrated pressureless spark plasma sintering. Herein, monolithic TaC and HfC UHTC foams and their composite show the partial solid–solution formation of (Ta, Hf)C with porosity ≥50%. TaC–HfC foam (≈80–92 N) shows an intermediate load‐bearing capability compared to monolithic TaC (≈120–135 N) and HfC (≈28–35 N) foams, with no evident cracking on the sample surface. The thermal conductivity of partial solid‐solution TaC–HfC foam increases up to fivefold compared to parent UHTC foams. In the results, solid solutions’ efficacy and pores’ unidirectionality in providing thermal insulation to TaC–HfC while maintaining its high‐load bearing capability are illustrated. In conclusion, the developed technique establishes a new paradigm shift in UHTCs, expanding their potential for TPS in extreme environments.

36 MATERIALS SCIENCE

The impact of aerosol mixing state on immersion freezing: insights from classical nucleation theory and particle-resolved simulations

Immersion freezing, initiated by ice-nucleating particles (INPs) in supercooled aqueous droplets, plays an important role in the formation of ice crystals within clouds. The efficiency of immersion freezing depends strongly on INP composition and, crucially, on the mixing state – how chemical species are distributed across the particle population. Here, we quantify the impact of aerosol mixing state on immersion freezing using a combined theoretical and particle-resolved modeling approach. We derive analytical expressions for the frozen fraction of internally and externally mixed INP populations based on classical nucleation theory, showing that the frozen fraction is sensitive to whether ice-active species are present in all particles or only in a subset of the population. We introduce a multi-species immersion freezing scheme into the particle-resolved model PartMC, using the water activity-based immersion freezing model (ABIFM) to compute freezing probabilities for mixed-composition particles. To improve computational efficiency, we implement a Binned Tau-Leaping algorithm and demonstrate an order-of-magnitude speedup with minimal accuracy loss. Simulations reproduce the analytical trends in limiting cases and extend the analysis to more general aerosol populations, where mixing state continues to exert a substantial control on frozen fraction. Sensitivity analyses across particle size, species type, and cooling condition reveal that the mixing state effect is most pronounced when small amounts of highly efficient INPs are mixed with less efficient materials. These findings underscore the need to represent aerosol mixing state explicitly in models of heterogeneous ice nucleation to reduce uncertainty in cloud-phase partitioning.

54 ENVIRONMENTAL SCIENCES

Getting Warmer: IceCube Nears Freeze Out

IceCube has recently detected a diffuse population of high-energy neutrinos arising from the Milky Way. We use this high-significance detection to place new limits on dark matter (DM) annihilation to neutrinos with two complementary approaches. The first method uses the background-subtracted Galactic longitude distribution of shower events to place a conservative bound on the DM annihilation cross section that does not rely on any assumed Galactic cosmic ray emission model; the resulting limits on the velocity-averaged annihilation cross section improve upon existing bounds by factors of a few. The second method uses the template-dependent neutrino energy spectra from the Inner Galaxy, inferred under different Galactic cosmic ray emission models. This complementary approach shows that the inferred Galactic neutrino intensities are already sensitive to DM contributions near the thermal-relic benchmark for a range of TeV-scale DM masses, though this comparison is more model-dependent. Our results demonstrate that measurements of diffuse Galactic neutrino emission can be used as a powerful probe of DM annihilation into neutrinos. Future observations with IceCube-Gen2 and KM3NeT will substantially extend this sensitivity, potentially allowing a decisive test of the thermal freeze-out mechanism with Galactic neutrino observations.

Mukhopadhyay, Mainak [Fermilab; Chicago U., KICP;

Heavy long-lived dark vector via a gluonic portal

We study a dark gauge boson Z′ that exclusively couples to the QCD gluons through higher dimensional operators. These operators are generated from integrating out of heavy ultraviolet resonances carrying both QCD and dark gauge charges. With SU(3)C gauge invariance, charge and parity symmetries preserved, we find that the leading effective operators are restricted to have the form of Z′GGG and Z′Z′GG at dimension-eight, which can naturally render the Z′ particle long-lived, and serve as a viable dark matter candidate. We investigate the phenomenology of these operators with both collider experiments and cosmological observation, without and with the assumption that this dark gauge boson plays the role of the dominant dark matter component. For an unstable Z′, we show that depending on its lifetime, it can be probed by various observables up to ultraviolet physics scale around 10 9 GeV. For Z′ being dark matter, we find that $m_{Z'}$ ≳ 1 TeV is consistent with the thermal freeze-out scenario. In contrast, in the freeze-in scenario, the extremely small couplings leave the relevant parameter space largely unconstrained by current experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Fire Protection Design

The purpose of this project is to design the demolition and installation of a deluge valve swap from a DV-5 to a DV-5A valve.

99 GENERAL AND MISCELLANEOUS

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION

A Technical Evaluation of Self-Protection Dose Rates in U.S. Domestic Nuclear Security Policy

U.S. nuclear security policy uses radiation self-protection as a basis for reducing material attractiveness, but existing dose-rate criteria may not reflect the time scales of theft or sabotage. This report evaluates whether the commonly cited 1 Gy/h at 1 m criterion can plausibly cause adversary task failure during short-duration malicious acts.

Fritchie, Jacob Wesley [Sandia National Laboratori

Protection of battery electrodes against side reactions

A battery electrode composition is provided that comprises composite particles. Each of the composite particles in the composition (which may represent all or a portion of a larger composition) may comprise a porous electrode particle and a filler material. The porous electrode particle may comprise active material provided to store and release ions during battery operation. The filler material may occupy at least a portion of the pores of the electrode particle. The filler material may be liquid and not substantially conductive with respect to electron transport.

Yushin, Gleb

A Novel Approach to Investigate Thermal Protection Systems Materials

The Koo Research Group (KRG) at The University of Texas at Austin (UT) and KAI has specialized in “Ablation Research” for more than fifteen years. Recently, the group has developed several incredibly unique capabilities that can advance “Thermal Protection Systems (TPS) Materials Research & Development” using an integrated experimental and numerical approach. The paper aims to introduce the methodology KRG has developed to solve this challenging problem. It will discuss how the KRG develops “Process-Properties-Performance” relationships of novel TPS materials in a systematical approach using (a) processing and fabrication, (b) thermal characterization of properties, (c) aerothermal testing, (d) microstructures characterization and analysis, and (e) numerical modeling. Progress and challenges of this research will also be discussed.

Engineering

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification

Development of in-situ polymerized intrinsically conductive resin and low-cost carbon pigments offering high conductivity for sensing, EMI shielding and lighting protection

Electrically conductive composites are emerging across diverse industries such as electronic, automotive, aerospace, advanced air mobility, biomedical, infrastructure, defense and security offering static charge dissipation, electromagnetic interference shielding, lighting protection, sensing, dicing, corrosion monitoring, etc. Conductivity enhanced composites provide several advantages compared to conventional metals including weight reduction, corrosion resistance, energy efficient processability, tunable properties and multifunctionality. Polymers are typically insulating in nature and require conducting filler for electron transport. However, dispersion and polymer-filler interphases are critical and often disrupt conducting pathways. Besides, conductive fillers such as graphene, carbon nanotube, MXene, silver nanowire, etc. are expensive, limiting their wide adoption in composite industry. On the other hand, a limited number of intrinsically conductive polymers are available among which polyaniline (PANI) has been widely studied due to its high conductivity, thermal and chemical stability. However, PANI is difficult to process and exhibits weak mechanical properties. In brief, there is a significant demand for electrically conductive polymer formulation with cost-effective conducting fillers that offer processability in scale to expand the market of conductivity enhanced materials.

Kumar, Vipin [Oak Ridge National Laboratory (ORNL)

Nuclear Security Risks for HALEU Fuels

There is growing interest in high-assay low-enriched uranium (HALEU) for use in advanced nuclear reactors as a high-energy fuel source. The primary objectives of this report are to identify the security risks that directly result from HALEU and to identify the gaps and challenges it presents from a theft and sabotage perspective. This study focuses on HALEU security risks for the front end of the fuel cycle and includes a review of the supply chain, fuel fabrication, and transport for terrestrial reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS