Analysis method for Fourier transform spectroscopy

A fast Fourier transform technique is given for the simulation of those distortion effects in the instrument line shape of the interferometric spectrum that are due to errors in the measured interferogram. The technique is applied to analyses of atmospheric absorption spectra and laboratory spectra. It is shown that the nonlinear least squares method can retrieve the correct information from the distorted spectrum. Analyses of HF absorption spectra obtained in a laboratory and solar CO absorption spectra gathered by a balloon-borne interferometer indicate that the retrieved amount of absorbing gas is less than the correct value in most cases, if the interferogram distortion effects are not included in the analysis.

Park, J. H.

Analysis and application of Fourier transform spectroscopy in atmospheric remote sensing

An analysis method for Fourier transform spectroscopy is summarized with applications to various types of distortion in atmospheric absorption spectra. This analysis method includes the fast Fourier transform method for simulating the interferometric spectrum and the nonlinear least-squares method for retrieving the information from a measured spectrum. It is shown that spectral distortions can be simulated quite well and that the correct information can be retrieved from a distorted spectrum by this analysis technique.

Park, J. H.

The application of Fourier transform spectroscopy to the remote identification of solids in the solar system

The techniques of Fourier transform spectroscopy combined with large aperture telescopes and advances in detector technology now permit infrared (at a wavelength greater than 1 micron) observations of the surfaces of small solar system objects such as asteroids and satellites. The results demonstrate that this activity can produce important new compositional information related to the origin and evolution of the solar system. The detection of water ice in Saturn's rings and on some of the satellites of Jupiter and Saturn confirm expectations that ices are important mineralogical components in the chemistry of the outer solar system. More recent studies of the mineralogical composition of the surfaces of asteroids provide a new observational link to the origin of meteorites and the early thermal history of the solar system. These results have been dependent upon supporting laboratory studies of the spectral behavior of ices and minerals to define the potential, and limitations, of the method. Since many of the astronomical observations have been exploratory in nature, prospects are good that continued refinement of the techniques will lead to additional insights.

Larson, H. P.

Fourier-transform spectroscopy of O3 in the 3-micron region

Fourier transform spectra of ozone have been recorded in the 2-5-micron region at a resolution of 0.01/cm. Absorption lines belonging to numerous vibration-rotation transitions have been observed in these spectra, and a detailed analysis of the band system centered at 3.6 microns has been completed.

Smith, M. A. H.

Fiber-optic thermometer using Fourier transform spectroscopy

An integrated-optic Mach-Zender interferometer is used as a Fourier transform spectrometer to analyze the input and output spectra of a temperature-sensing thin-film etalon. This configuration provides a high degree of immunity to the effects of changes in the source spectrum, and it readily permits the interrogation of a number of different sensors using a single spectrometer. In addition, this system has a potentially low cost because it uses optical communications hardware that may in the future be manufactured in large quantities.

Beheim, Glenn

New Atomic Data for Doubly Ionized Iron Group Atoms by High Resolution UV Fourier Transform Spectroscopy

Currently available laboratory spectroscopic data of doubly ionized iron-group element were obtained about 50 years ago using spectrographs of modest dispersion, photographic plates, and eye estimates of intensities. The accuracy of the older wavelength data is about 10 mAngstroms at best, whereas wavelengths are now needed to an accuracy of 1 part in 10(exp 6) to 10(exp 7) (0.2 to 2 mAngstroms at 2000 Angstroms). The Fourier transform (FT) spectroscopy group at Imperial College, London, and collaborators at the Harvard College Observatory have used a unique VUV FT spectrometer in a program focussed on improving knowledge of spectra of many neutral and singly and doubly ionized, astrophysically important, iron group elements. Spectra of Fe II and Fe III have been recorded at UV and VUV wavelengths with signal-to-noise ratios of several hundred for the stronger lines. Wavelengths and energy levels for Fe III are an order of magnitude more accurate than previous work; analysis is close to completion. f-values for Fe II have been published.

Smith, Peter L.

High-resolution Fourier transform spectroscopy of the Meinel system of OH

The infrared spectrum of the hydroxyl radical OH, between 1850 and 9000/cm has been measured with a Fourier transform spectrometer. The source, a hydrogen-ozone diffusion flame, was designed to study the excitation of rotation-vibration levels of the OH Meinel bands under conditions similar to those in the upper atmosphere which produce the nighttime OH airglow emission. Twenty-three bands were observed: nine bands in the Delta upsilon = 1 sequence, nine bands in the Delta upsilon = 2 sequence, and five bands in the Delta upsilon = 3 sequence. A global nonlinear least-squares fit of 1696 lines yielded molecular parameters with a standard deviation of 0.003/cm. Term values are computed, and transition frequencies in the Delta upsilon = 3, 4, 5, 6 sequences in the near-infrared are predicted.

Abrams, Mark C.

Fourier transform spectroscopy of the nu3 band of the N3 radical

The nu3 transitions of N3 radicals produced by HN3-Cl reactions in a multipass cell (effective path length 100 m) are investigated experimentally using a Fourier-transform spectrometer with maximum resolution 0.004/cm. A total of 176 rotation-vibration lines are listed in a table and used, in combination with published data on 240 optical lines (Douglas and Jones, 1965), to determine the nu3 molecular constants. The lower-than-expected value of the nu3 fundamental frequency (1644.6784/cm) is attributed to the vibronic interaction discussed by Kawaguchi et al. (1981).

Brazier, C. R.

A Novel Application of Fourier Transform Spectroscopy with HEMT Amplifiers at Microwave Frequencies

The goal was to develop cryogenic high-electron-mobility transistor (HEMT) based radiometers and use them to measure the anisotropy in the cosmic microwave background (CMB). In particular, a novel Fourier transform spectrometer (FTS) built entirely of waveguide components would be developed. A dual-polarization Ka-band HEMT radiometer and a similar Q-band radiometer were built. In a series of measurements spanning three years made from a ground-based site in Saskatoon, SK, the amplitude, frequency spectrum, and spatial frequency spectrum of the anisotropy were measured. A prototype Ka-band FTS was built and tested, and a simplified version is proposed for the MAP satellite mission. The 1/f characteristics of HEMT amplifiers were quantified using correlation techniques.

Wilkinson, David T.

Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control

Progress has been made into adapting and enhancing a commercially available infrared spectrometer for the development of a handheld device for in-field measurements of the chemical composition of various samples of materials. The intent is to duplicate the functionality of a benchtop Fourier transform infrared spectrometer (FTIR) within the compactness of a handheld instrument with significantly improved spectral responsivity. Existing commercial technology, like the deuterated L-alanine triglycine sulfide detectors (DLATGS), is capable of sensitive in-field chemical analysis. This proposed approach compares several subsystem elements of the FTIR inside of the commercial, non-benchtop system to the commercial benchtop systems. These subsystem elements are the detector, the preamplifier and associated electronics of the detector, the interferometer, associated readout parameters, and cooling. This effort will examine these different detector subsystem elements to look for limitations in each. These limitations will be explored collaboratively with the commercial provider, and will be prioritized to meet the deliverable objectives. The tool design will be that of a handheld gun containing the IR filament source and associated optics. It will operate in a point-and-shoot manner, pointing the source and optics at the sample under test and capturing the reflected response of the material in the same handheld gun. Data will be captured via the gun and ported to a laptop.

Pugel, Diane

Fourier transform spectroscopy of the Swan (d(sup 3)pi(sub g) - a(sup 3)pi(sub u)) system of the jet-cooled C2 molecule

The Swan (d(sup 3)pi(sub g) - a(sup 3)pi(sub u)) system of the C2 molecule was produced in a jet-cooled corona excited supersonic expansion of helium using diazoacetonitrile as a percursor molecule. This spectrum was recorded using the McMath Fourier transform spectrometer of the National Solar Observatory at Kitt Peak. A total of nine bands with v prime = 0 to 3 and v prime prime = 0 to 4 in the range 16,570-22,760/cm were observed and rotationally analyzed. The C2 molecules in this source had a rotational temperature of only 90 K so that only the low-J lines were present in the spectrum. In some sense the low temperatures in the jet source simulate conditions in the interstellar medium. The Swan system of C2 was also produced in a composite wall hollow cathode made Al4C3/Cu, and the rotational structure of the 1-0, 2-1, 3-2, 0-0, and 1-1 bands were analyzed. The data obtained from both these spectra were fitted together along with some recently published line positions. The rotational constants, lambda doubling parameters and the vibrational constants were estimated from this global fit. Our work on jet-cooled C2 follows similar work on the violet and red systems of CN. A summary of this CN work is also presented. also presented.

Prasad, C. V. V.

An investigation of the optimization of parameters affecting the implementation of fourier transform spectroscopy at 20-500 micron from the C-141 airborne infrared observatory

A program for 20-500 micron spectroscopy from the NASA flying C141 infrared observatory is being carried out with a Michelson interferometer. The parameters affecting the performance of the instrument are studied and an optimal configuration for high performance on the C-141 aircraft is recommended. As each parameter is discussed the relative merits of the two modes of mirror motion (rapid scan or step and integrate) are presented.

Thompson, R. I.

Study of dynamic emission spectra from lubricant films in an elastohydrodynamic contact using Fourier transform spectroscopy

Infrared emission spectra were obtained through a diamond window from lubricating fluids in an operating sliding elastohydrodynamic contact and analyzed by comparison with static absorption spectra under similar pressures. Different loads, shear rates and temperatures were used. Most of the spectra exhibited polarization characteristics, indicating directional alignment of the lubricant in the EHD contact. Among the fluids studied were a "traction" fluid, an advanced ester, and their mixtures, a synthetic paraffin, a naphthenic reference fluid (N-1), both neat and containing 1 percent of p-tricresyl phosphate as an anti-wear additive, and a C-ether. Traction properties were found to be nearly proportional to mixture composition for traction fluid and ester mixtures. The anti-wear additive reduced traction and fluid temperature under low loads but increased them under higher loads, giving rise to formation of a friction polymer.

Lauer, J. L.

Airborne infrared astronomical observations by Fourier transform spectroscopy

Infrared spectroscopic observations from NASA-operated aircraft constitute a rapidly maturing application of FTS methods initially developed for ground-based telescopes. Coupled to airborne telescopes up to 36 in. in diameter, these experiments are now producing new astronomical results as exciting and unexpected as those derived from Connes's first high resolution planetary observations at mountain-top observatories. This review examines the special problems of the IR spectral region that led to aircraft observatories and includes a brief survey of the facilities themselves and their modes of operation. The special problems of operating FTS devices on aircraft and the scientific results achieved with current capabilities are discussed. Finally, airborne observations are compared to the ultimate in high-altitude observing platforms: earth-orbiting cooled and uncooled telescopes carried by the Space Shuttle vehicle.