Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier transform spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis method for Fourier transform spectroscopy

A fast Fourier transform technique is given for the simulation of those distortion effects in the instrument line shape of the interferometric spectrum that are due to errors in the measured interferogram. The technique is applied to analyses of atmospheric absorption spectra and laboratory spectra. It is shown that the nonlinear least squares method can retrieve the correct information from the distorted spectrum. Analyses of HF absorption spectra obtained in a laboratory and solar CO absorption spectra gathered by a balloon-borne interferometer indicate that the retrieved amount of absorbing gas is less than the correct value in most cases, if the interferogram distortion effects are not included in the analysis.

Park, J. H.↗

Analysis and application of Fourier transform spectroscopy in atmospheric remote sensing

An analysis method for Fourier transform spectroscopy is summarized with applications to various types of distortion in atmospheric absorption spectra. This analysis method includes the fast Fourier transform method for simulating the interferometric spectrum and the nonlinear least-squares method for retrieving the information from a measured spectrum. It is shown that spectral distortions can be simulated quite well and that the correct information can be retrieved from a distorted spectrum by this analysis technique.

Park, J. H.↗

Theoretical framework for soft X-ray Fourier transform spectroscopy using the Wigner function

This work presents a theoretical framework for the propagation of partially coherent Gaussian radiation in a modified Mach–Zehnder interferometer designed for Fourier transform spectroscopy (FTS) applications. Using the Wigner function formalism, we analytically propagate the radiation through the system and benchmark our approach by comparing the resulting interference pattern and interferogram with previous works in the diffraction limit. Our analysis reveals that the transverse coherence length requirement of the incident light field for detectable modulation is less stringent than previously assumed. Additionally, we provide theoretical demonstrations of FTS performance across various wavelengths using the proposed setup. These findings underscore the potential of this interferometer to achieve high-resolution FTS in the soft X-ray regime.

Fourier transform spectroscopy↗

The application of Fourier transform spectroscopy to the remote identification of solids in the solar system

The techniques of Fourier transform spectroscopy combined with large aperture telescopes and advances in detector technology now permit infrared (at a wavelength greater than 1 micron) observations of the surfaces of small solar system objects such as asteroids and satellites. The results demonstrate that this activity can produce important new compositional information related to the origin and evolution of the solar system. The detection of water ice in Saturn's rings and on some of the satellites of Jupiter and Saturn confirm expectations that ices are important mineralogical components in the chemistry of the outer solar system. More recent studies of the mineralogical composition of the surfaces of asteroids provide a new observational link to the origin of meteorites and the early thermal history of the solar system. These results have been dependent upon supporting laboratory studies of the spectral behavior of ices and minerals to define the potential, and limitations, of the method. Since many of the astronomical observations have been exploratory in nature, prospects are good that continued refinement of the techniques will lead to additional insights.

Larson, H. P.↗

Mechanistic aspects of plasma-enhanced catalytic methane decomposition by time-resolved operando diffuse reflectance infrared Fourier transform spectroscopy

To study mechanistic aspects of plasma-enhanced catalysis, methane is decomposed by a supported Ni catalyst assisted by an Ar/O 2 atmospheric pressure plasma jet (APPJ). Here, the time-resolved surface response of the Ni catalyst is investigated by operando diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) using various experimental settings. Catalyst temperatures of room temperature (RT) and 500 °C and nozzle-catalyst surface distances of 3, 5 and 8 mm were examined, and the amount of O 2 of the Ar/O 2 gas mixture flowing through the APPJ was either 0 or 0.5%. A synergistic effect of surface bonded C-O was observed during the exposure of the Ni catalyst to the APPJ for low oxygen operating conditions (pure Ar jet). Surface bonded C-O formed only when there was plasma present and the C-O signal was enhanced for higher catalyst temperature. When the supported Ni catalyst was subjected to the plasma-generated particle fluxes using highly oxidizing conditions, the presence of surface bonded C-O was suppressed. The plasma-catalytic CO and CO 2 production in the gas phase measured downstream mirrored the surface behavior of C-O bonds when the plasma source operating condition was changed from a low oxygen portion to a high oxygen portion at high catalyst temperature (500 °C). CH n (n =1, 2, ) species on the catalyst surface were also studied by DRIFTS, and CHn destruction was found to correlate with C-O formation. In particular, the time-resolved CH n response showed a possible conversion process of CH n to C-O when the Ni catalyst was exposed to the plasma source. This finding may indicate a plasma-mediated regeneration of the catalyst by plasma-catalyst surface interactions.

42 ENGINEERING↗

Fourier-transform spectroscopy of O3 in the 3-micron region

Fourier transform spectra of ozone have been recorded in the 2-5-micron region at a resolution of 0.01/cm. Absorption lines belonging to numerous vibration-rotation transitions have been observed in these spectra, and a detailed analysis of the band system centered at 3.6 microns has been completed.

Smith, M. A. H.↗

A comprehensive review of diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) techniques in protonic ceramic cells (PCCs): Current status and future perspective

Protonic ceramic cells (PCCs) have emerged as a promising technology for power generation, energy storage, and value-added chemical synthesis, offering benefits such as fuel flexibility, low emissions, and efficient operation at intermediate temperatures (300–600 ​°C). Recently, significant breakthroughs in materials and manufacturing methods have markedly enhanced the performance of PCCs. However, establishing a fundamental understanding of their electrocatalytic reactions has gained less attention. As a fast and cost-effective method for physicochemical fingerprinting, diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) has proven to be a surface-sensitive analytical tool for structural and functional studies. This review critically examines the most up-to-date applications of DRIFTS for characterizing key components of PCCs, including oxygen electrodes, protonic electrolytes, and hydrogen electrodes for different applications, with a focus on revealing hydration properties and catalytic reactions, and guiding rational material design. The challenges for advancing DRIFTS, including quantitative capabilities and operando applications for PCC investigations, are highlighted and strategies to tackle these challenges are discussed. Ultimately, this review underscores the critical role of DRIFTS in accelerating the development of high-performance and durable PCCs for next-generation energy solutions, offering methodologies and insights broadly applicable to a wide range of electrochemical energy conversion and storage technologies.

Diffuse Reflectance Infrared Fourier Transform Spe↗

Probing the proton exchange kinetics of BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3− δ ceramic electrolyte by operando diffuse reflectance infrared Fourier transform spectroscopy

Proton exchange kinetics plays an important role in governing the performance of intermediate-temperature protonic ceramic electrolysis cells (PCECs) for hydrogen production. Our understanding of the nature of the surface hydration reaction at the single-cell level, however, remains very limited, hampering further efficiency improvements. Here, in this study, we developed a custom operando diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) platform that operates under high temperature and steam conditions with applied bias. Quantitative investigations of surface H 2 O/D 2 O isotope exchange in a BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3−δ (BZCYYb1711) protonic electrolyte-based single cell were conducted under different applied voltages using this DRIFTS platform, to gain molecular-level insight into hydration kinetics. The findings show that the application of an external voltage significantly enhances the surface proton exchange rate, decreasing the apparent activation energy from 29.1 kJ mol −1 at open-circuit voltage (OCV) to 6.8 kJ mol −1 at 1.3 V. In addition, distinct voltage-induced spectral shifts in O–D vibrations point to dynamic changes in surface hydration. These findings demonstrate a sensitive spectroscopic platform for probing interfacial proton processes and reveal strong electrochemical control over surface proton kinetics, offering new opportunities for probing electrolyte hydration behavior in PCECs.

36 - MATERIALS SCIENCE↗

Poison or Promoter? Investigating the Dual-Role of Carbon Monoxide in Pincer-Iridium-Based Alkane Dehydrogenation Systems via Operando Diffuse Reflectance Infrared Fourier Transform Spectroscopy

Pincer-ligated iridium complexes of the form [( R 4 PCP)IrL] ( R 4 PCP = κ 3 -C 6 H 3 -2,6-(XPR 2 ) 2 ; X = CH 2 , O; R = tBu, iPr) have previously been shown competent for acceptorless alkane dehydrogenation when supported on silica. It was observed by postcatalysis solid-state NMR that silica-tethered [(≡SiO- tBu 4 POCOP)Ir(C 2 H 4 )] (3-C 2 H 4 ) was converted fully to [(≡SiO- tBu 4 POCOP)Ir(CO)] (3-CO) at 300 °C. In this work, the characterization of species under dehydrogenation reaction conditions far from equilibrium between butane and butenes (approach to equilibrium Q/K eq = 0.3 at 300 °C) is performed with operando Diffuse Reflectance Infrared Fourier–Transform Spectroscopy (DRIFTS) to show the kinetics of species conversion from 3-C 2 H 4 to 3-CO. It is further found that [(≡SiO- tBu 4 POCOP)IrHCl] (3-HCl), a species considered to be a precatalyst for alkane dehydrogenation, is also fully converted to 3-CO. Here, a mechanism of decomposition is proposed that implicates surface silanol groups, while carbon monoxide acts as a “stabilizer” for the catalyst by promoting their reductive elimination and maintaining the complex in the I oxidation state.

02 PETROLEUM↗

Fiber-optic thermometer using Fourier transform spectroscopy

An integrated-optic Mach-Zender interferometer is used as a Fourier transform spectrometer to analyze the input and output spectra of a temperature-sensing thin-film etalon. This configuration provides a high degree of immunity to the effects of changes in the source spectrum, and it readily permits the interrogation of a number of different sensors using a single spectrometer. In addition, this system has a potentially low cost because it uses optical communications hardware that may in the future be manufactured in large quantities.

Beheim, Glenn↗

New Atomic Data for Doubly Ionized Iron Group Atoms by High Resolution UV Fourier Transform Spectroscopy

Currently available laboratory spectroscopic data of doubly ionized iron-group element were obtained about 50 years ago using spectrographs of modest dispersion, photographic plates, and eye estimates of intensities. The accuracy of the older wavelength data is about 10 mAngstroms at best, whereas wavelengths are now needed to an accuracy of 1 part in 10(exp 6) to 10(exp 7) (0.2 to 2 mAngstroms at 2000 Angstroms). The Fourier transform (FT) spectroscopy group at Imperial College, London, and collaborators at the Harvard College Observatory have used a unique VUV FT spectrometer in a program focussed on improving knowledge of spectra of many neutral and singly and doubly ionized, astrophysically important, iron group elements. Spectra of Fe II and Fe III have been recorded at UV and VUV wavelengths with signal-to-noise ratios of several hundred for the stronger lines. Wavelengths and energy levels for Fe III are an order of magnitude more accurate than previous work; analysis is close to completion. f-values for Fe II have been published.

Smith, Peter L.↗

High-resolution Fourier transform spectroscopy of the Meinel system of OH

The infrared spectrum of the hydroxyl radical OH, between 1850 and 9000/cm has been measured with a Fourier transform spectrometer. The source, a hydrogen-ozone diffusion flame, was designed to study the excitation of rotation-vibration levels of the OH Meinel bands under conditions similar to those in the upper atmosphere which produce the nighttime OH airglow emission. Twenty-three bands were observed: nine bands in the Delta upsilon = 1 sequence, nine bands in the Delta upsilon = 2 sequence, and five bands in the Delta upsilon = 3 sequence. A global nonlinear least-squares fit of 1696 lines yielded molecular parameters with a standard deviation of 0.003/cm. Term values are computed, and transition frequencies in the Delta upsilon = 3, 4, 5, 6 sequences in the near-infrared are predicted.

Abrams, Mark C.↗

Fourier transform spectroscopy of the nu3 band of the N3 radical

The nu3 transitions of N3 radicals produced by HN3-Cl reactions in a multipass cell (effective path length 100 m) are investigated experimentally using a Fourier-transform spectrometer with maximum resolution 0.004/cm. A total of 176 rotation-vibration lines are listed in a table and used, in combination with published data on 240 optical lines (Douglas and Jones, 1965), to determine the nu3 molecular constants. The lower-than-expected value of the nu3 fundamental frequency (1644.6784/cm) is attributed to the vibronic interaction discussed by Kawaguchi et al. (1981).

Brazier, C. R.↗

A Novel Application of Fourier Transform Spectroscopy with HEMT Amplifiers at Microwave Frequencies

The goal was to develop cryogenic high-electron-mobility transistor (HEMT) based radiometers and use them to measure the anisotropy in the cosmic microwave background (CMB). In particular, a novel Fourier transform spectrometer (FTS) built entirely of waveguide components would be developed. A dual-polarization Ka-band HEMT radiometer and a similar Q-band radiometer were built. In a series of measurements spanning three years made from a ground-based site in Saskatoon, SK, the amplitude, frequency spectrum, and spatial frequency spectrum of the anisotropy were measured. A prototype Ka-band FTS was built and tested, and a simplified version is proposed for the MAP satellite mission. The 1/f characteristics of HEMT amplifiers were quantified using correlation techniques.

Wilkinson, David T.↗