Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Forensic Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Thermoluminescence: Potential Applications in Forensic Science

In crime laboratories one of the most difficult operations is to determine unequivocally whether or not two samples of evidence of the same type were originally part of the same thing or were from the same source. It has been found that high temperature thermoluminescence (room temperature to 723 K) can be used for comparisons of this type, although work to date indicates that there is generally a finite probability for coincidental matching of glass or soil samples. Further work is required to determine and attempt to minimize these probabilities for different types of materials, and to define more clearly the scope of applicability of thermoluminescence to actual forensic situations.

Ingham, J. D.

NEAR Gamma Ray Spectrometer Characterization and Repair

This report covers the work completed in the third year of the contract. The principle activities during this period were (1) the characterization of the NEAR 2 Gamma Ray Spectrometer using a neutron generator to generate complex gamma ray spectra and a large Ge Detecter to identify all the major peaks in the spectra; (2) the evaluation and repair of the Engineering Model Unit of the Gamma Ray Spectrometer for the NEAR mission; (3) the investigation of polycapillary x-ray optics for x-ray detection; and (4) technology transfer from NASA to forensic science.

Groves, Joel Lee

Versatile Vials

Advanced Fuel Research, Inc. (AFR) developed a new sol-gel material coating for sample vials to be used in surface-enhanced Raman (SER) spectroscopy. In the fields of biomedical and forensic science, the coated vials are used to identify physiological chemicals present in blood and urine. The vials are used in the pharmaceutical industry in the area of drug development and discovery. In the drug enforcement field, using the vials helps with detection of trace amounts of drugs on surfaces. The SER vials will also help to identify contaminants in water sources, such as various inorganics and pesticides. The new vials have advantages over other SER materials. Former products required that samples be pre-mixed or dissolved into specific solvents or reagents. The SER vials do not have these limitations, and measurements can be performed using any solvent. Furthermore, the signal appears in less than one second. The sol-gel material will stay active for at least one year and the vials are compatible with any Raman spectrometer. Most importantly, the SER activity can be duplicated from vial-to-vial, allowing for reproducible results.

Source record

Hyperspectral Systems Increase Imaging Capabilities

In 1983, NASA started developing hyperspectral systems to image in the ultraviolet and infrared wavelengths. In 2001, the first on-orbit hyperspectral imager, Hyperion, was launched aboard the Earth Observing-1 spacecraft. Based on the hyperspectral imaging sensors used in Earth observation satellites, Stennis Space Center engineers and Institute for Technology Development researchers collaborated on a new design that was smaller and used an improved scanner. Featured in Spinoff 2007, the technology is now exclusively licensed by Themis Vision Systems LLC, of Richmond, Virginia, and is widely used in medical and life sciences, defense and security, forensics, and microscopy.

Source record

Electric Potential and Electric Field Imaging with Dynamic Applications: 2017 Research Award Innovation

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field may be used for illuminating volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Initial results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed

Electric Potential and Electric Field Imaging with Dynamic Applications & Extensions

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field made be used for volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. Extensions to environment, Space and subterranean applications will be presented, and initial results for quantitative characterizing material properties are shown. A wearable EFI system has been developed by using fundamental EFI concepts. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, manufacturing quality control, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, weather prediction, earth quake prediction, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed

Better Pictures in a Snap

Retinex Imaging Processing, winner of NASA's 1999 Space Act Award, is commercially available through TruView Imaging Company. With this technology, amateur photographers use their personal computers to improve the brightness, scene contrast, detail, and overall sharpness of images with increased ease. The process was originally developed for remote sensing of the Earth by researchers at Langley Research Center and Science and Technology Corporation (STC). It automatically enhances a digital image in terms of dynamic range compression, color independence from the spectral distribution of the scene illuminant, and color/lightness rendition. As a result, the enhanced digital image is much closer to the scene perceived by the human visual system, under all kinds and levels of lighting variations. TruView believes there are other applications for the software in medical imaging, forensics, security, recognizance, mining, assembly, and other industrial areas.

Source record

The Reconstruction and Failure Analysis of the Space Shuttle Columbia

Several days following the Columbia accident a team formed and began planning for the reconstruction of Columbia. A hangar at the Kennedy Space Center was selected for this effort due to it's size, available technical workforce and materials science laboratories and access to the vehicle ground processing infrastructure. The Reconstruction team established processes for receiving, handling, decontamination, tracking, identifying, cleaning and assessment of the debris. Initially, a 2-dimensional reconstruction of the Orbiter outer mold line was developed. As the investigation progressed fixtures which allowed a 3-dimensional reconstruction of the forward portions of the left wing's leading edge was developed. To support the reconstructions and forensic analyses a Materials and Processes (M&P) 'team was formed. This M&P team established processes for recording factual observations, debris cleaning, and engineering analysis. Fracture surfaces and thermal effects of selected airframe debris were assessed, and process flows for both nondestructive and destructive sampling and evaluation of debris were developed. The Team also assessed left hand airframe components that were believed to be associated with a structural breach of Columbia. A major portion of this analysis was evaluation of metallic deposits were prevalent on left wing leading edge components. Extensive evaluation of the visual, metallurgical and chemical nature of the deposits provided conclusions that were consistent with the visual assessments and interpretations of the NASA lead teams and the findings of the Columbia Accident Investigation Board. Analytical data collected by the M&P Team showed that a significant thermal event occurred at the left wing leading edge in the proximity of LH RCC Panels 8-9, and a correlation was formed between the deposits and overheating in these areas to the wing leading edge components. The analysis of deposits also showed exposure to temperatures in excess of 1649 C (3200 F), which would severely degrade support structure, tiles, and RCC panel materials. The integrated failure analysis of wing leading edge debris and deposits strongly supported the hypothesis that a breach occurred at LH RCC Panel 8.

Russell, Richard

NASA Tech Briefs, March 2012

The topics include: 1) Spectral Profiler Probe for In Situ Snow Grain Size and Composition Stratigraphy; 2) Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control; 3) In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer; 4) Physics Mining of Multi-Source Data Sets; 5) Photogrammetry Tool for Forensic Analysis; 6) Connect Global Positioning System RF Module; 7) Simple Cell Balance Circuit; 8) Miniature EVA Software Defined Radio; 9) Remotely Accessible Testbed for Software Defined Radio Development; 10) System-of-Systems Technology-Portfolio-Analysis Tool; 11) VESGEN Software for Mapping and Quantification of Vascular Regulators; 12) Constructing a Database From Multiple 2D Images for Camera Pose Estimation and Robot Localization; 13) Adaption of G-TAG Software for Validating Touch and Go Asteroid Sample Return Design Methodology; 14) 3D Visualization for Phoenix Mars Lander Science Operations; 15) RxGen General Optical Model Prescription Generator; 16) Carbon Nanotube Bonding Strength Enhancement Using Metal Wicking Process; 17) Multi-Layer Far-Infrared Component Technology; 18) Germanium Lift-Off Masks for Thin Metal Film Patterning; 19) Sealing Materials for Use in Vacuum at High Temperatures; 20) Radiation Shielding System Using a Composite of Carbon Nanotubes Loaded With Electropolymers; 21) Nano Sponges for Drug Delivery and Medicinal Applications; 22) Molecular Technique to Understand Deep Microbial Diversity; 23) Methods and Compositions Based on Culturing Microorganisms in Low Sedimental Fluid Shear Conditions; 24) Secure Peer-to-Peer Networks for Scientific Information Sharing; 25) Multiplexer/Demultiplexer Loading Tool (MDMLT); 26) High-Rate Data-Capture for an Airborne Lidar System; 27) Wavefront Sensing Analysis of Grazing Incidence Optical Systems; 28) Foam-on-Tile Damage Model; 29) Instrument Package Manipulation Through the Generation and Use of an Attenuated-Fluent Gas Fold; 30) Multicolor Detectors for Ultrasensitive Long-Wave Imaging Cameras; 31) Lunar Reconnaissance Orbiter (LRO) Command and Data Handling Flight Electronics Subsystem; and 32) Electro-Optic Segment-Segment Sensors for Radio and Optical Telescopes.

Source record

Accident Precursor Analysis and Management: Reducing Technological Risk Through Diligence

Almost every year there is at least one technological disaster that highlights the challenge of managing technological risk. On February 1, 2003, the space shuttle Columbia and her crew were lost during reentry into the atmosphere. In the summer of 2003, there was a blackout that left millions of people in the northeast United States without electricity. Forensic analyses, congressional hearings, investigations by scientific boards and panels, and journalistic and academic research have yielded a wealth of information about the events that led up to each disaster, and questions have arisen. Why were the events that led to the accident not recognized as harbingers? Why were risk-reducing steps not taken? This line of questioning is based on the assumption that signals before an accident can and should be recognized. To examine the validity of this assumption, the National Academy of Engineering (NAE) undertook the Accident Precursors Project in February 2003. The project was overseen by a committee of experts from the safety and risk-sciences communities. Rather than examining a single accident or incident, the committee decided to investigate how different organizations anticipate and assess the likelihood of accidents from accident precursors. The project culminated in a workshop held in Washington, D.C., in July 2003. This report includes the papers presented at the workshop, as well as findings and recommendations based on the workshop results and committee discussions. The papers describe precursor strategies in aviation, the chemical industry, health care, nuclear power and security operations. In addition to current practices, they also address some areas for future research.

Phimister, James R.

Chemical Reactivity of In-Situ Lunar Dust for Biotoxicity Assessment

Introduction: How does the chemical reactivity of in-situ lunar dust compare to Apollo samples currently stored in curation facilities here on Earth? Essential investigations of this question will help us to further mitigate exploration risks for future human explorers on the Moon and will also provide critical information for astrobiologists and space biologists using the Moon for scientific inquiry. Discussion: Apollo 14 dust biotoxicity studies, carried out by the NASA Lunar Airborne Dust Toxici-ty Assessment Group (LADTAG), included numerous physiochemical studies[1] and cellular and animal ex-periments. Intratracheal instillation [2] and inhalation studies [3] in rats both showed Apollo 14 dust to be intermediate in toxicity compared to low-tox titanium dusts and high-tox quartz dusts of similar particle siz-es. The collective results were used in models [4] to establish a safe exposure limit for astronauts [5]. Alt-hough LADTAG took extensive steps to preserve what chemical reactivity may still have existed in the sam-ples, it is simply unknown if they possessed true in-situ chemical reactivity or if that reactivity has de-cayed. Initial gas loss on collection and other altera-tions, and even intermittent exposure to Earth-normal conditions during subsequent decades of handling, obscure a forensic reconstruction of the initial state. Because a mineral dust’s chemical reactivity influ-ences its biotoxicity [6], researchers have developed methods to “activate” lunar dust and simulants [7][8]. Past studies that modeled impact processes and radia-tion [9] in the lunar environment suggest that in-situ lunar dust is likely to be more chemically reactive than Earth-exposed samples. Because of these results, in-situ measurements are warranted [10]. Other studies have examined the hydroxyl generating capability of iron bearing mineral phases [11][12] and further em-phasize the role iron plays in chemical reactivity of lunar material, as well as decay of chemical reactivity in mineral dusts [12]. Recent observations of the lunar surface reveal the presence of hematite [13], a finding that further supports the hypothesis that in-situ lunar dust is reactive. Since the lunar surface is heterogene-ous, dust biotoxicity is expected to vary from site to site [14] due to particle size, mineralogy, physical characteristics, degree of space weathering, and chemi-cal reactivity (Figure 1). This circumstance dictates dust assessments at a suite of lunar sites enabled by upcoming NASA and commercial lunar payload ser-vices (CLPS) opportunities. Dose, location, and dura-tion of particle exposure will also affect biological responses. In-situ chemical reactivity measurements can inform cross-cutting collaborative research cam-paigns such as astrobiology studies examining regolith interactions with organisms and its ability to preserve chemical and structural biomarkers, as well as space biology investigations that examine regolith-microbe interactions relating to life support systems, plant growth, biomining, and development of regolith bio-composites. Figure 1: Environment conditions on the lunar surface that may alter regolith reactivity. Summary A series of in-situ measurements of lu-nar dust free radical chemistry at future Artemis and CLPS landing sites, combined with LADTAG-like studies of freshly collected lunar dust specimens, will reveal the true chemical reactivity of in-situ lunar dust and generate scientific data that can be compared to the chemical reactivity and biotoxicity of samples from Apollo landing sites. Furthermore, results from in situ measurements and biotoxicity studies of freshly col-lected specimens can also be used to validate, or re-quire revision of, the current astronaut permissible exposure limit [15]. References: [1] McKay D et al (2015), Acta As-tronaut 107:163–176. [2] Rask J et al (2013), LPSC, p 3062. [3] Lam CW et al (2013), Inhal Toxicol 25:661–678. [4] James JT, et. al. (2013) , Inhal Toxicol 25:243–256. [5] Scully RR, et.al. (2013), Inhal Toxi-col 25:785–793. [6] Porter, D. W., et.al., (2002), Tox-icology 175, 63–71. [7] Wallace WT, et.al., (2009), Meteorit Planet Sci 44:961–970. [8] Wallace WT, et.al., (2010), Earth Planet Sci Lett 295:571–577. [9] Loftus D, Rask J, et.al., (2010), Earth Moon Planet 107:95–105. [10] Rask J, et.al., (2009) LEAG p 57. [11] Turci F, et.a., (2015), Astrobiology. 2015;15(5):371-380. [12] Hendrix DA, et.al., (2019), Geohealth. 2019;3(1):28-42. [13] Li, S., et.al., (2020), Science advances, 6(36), p.eaba1940. [14] Rask J. (2018), In: Cudnik B. (eds) Encyclopedia of Lunar Science. Springer, Cham. [15] Rask, J, (2020), LPI, Artemis III Sci. def. paper 2120.

chemical reactivity