Impact of Flux Wire Selection on Neutron Spectrum Adjustment

In reactor dosimetry, spectrum unfolding methods are used to assess the energy-dependent neutron flux following the irradiation of flux wires or foils. For some spectrum unfolding methods, an a priori, or initial guess, spectrum is necessary. However, if the a priori spectrum is not representative of the irradiation spectrum experienced by the flux wires, the spectrum unfolding method may fail or create a nonphysical adjusted spectrum. The unfolded spectrum is dependent on flux wire reaction rates, and therefore cross section. As a result, each selection or combination of flux wires will have a different sensitivity to the group-wise fluence difference between the a priori spectrum and the irradiation spectrum. Therefore, a selection of flux wires that are insensitive to errors in the a priori spectrum would be considered robust choices for reactor dosimetry. In this work, flux wire reaction rates are calculated using a simulated neutron spectrum from the High Flux Isotope Reactor (HFIR) and spectrum unfolding methods are used in each flux wire combinations. The flux wire combinations are compared against a traditional flux wire set of Ti, Fe, and Co, with a summary table of the deemed “good” wire combinations that are insensitive to number of a priori neutron energy groups, group-wise difference between the a priori and irradiation, and magnitude of difference.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Drawing 445754 rev5

Drawing 445754 contains the details for fabricating plastic flux wands used in ATR and ATRC. The flux wands are used to position flux wires in fuel elements. The flux wands are basically a tool to position the flux wires. The flux wires are later removed from the flux wands and counted to determine the amount of flux they received. The flux wands come in contact with reactor primary coolant, but do not control the primary coolant (this is in reference to 10 CFR Part 810). Additional wands need to be fabricated. This drawing needs to be sent to a vendor or vendors for procurement of new flux wands as done in the past. LWP-11201 rev 11 (pg. 27) indicates providing information to a vender is not a public release. This drawing does not need to be released to all of the public if that is an option. It just needs to go to a vendors or vendors. A vendor will likely need to see the drawing to determine if they can build the flux wands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling of the TREAT M8 Calibration Series Measurements using MAMMOTH

This presentation provides an overview of the modeling efforts performed in to validate the MAMMOTH multi-physics reactor analysis application using historical TREAT data. These data come from the M8 series of calibration measurements, which was the last series performed before TREAT was shut down in 1994. The data applied in this work include an experiment flux profile and low level steady state power coupling factors for both flux wires and fuel pins. MAMMOTH was able to obtain reasonable results for all cases with the exception of the H91-8-1 flux wire, the only flux wire containing highly-enriched uranium. The feasibility of performing similar simulations of the calibration series fuel pins was demonstrated with the flux wire calculations, and will be performed in future work.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Graphite Creep Uncertainty Analysis

Radiation damage estimation is an important component of the post irradiation analysis of the Advanced Graphite Creep (AGC) experiment. It depends primarily on the fast fluence, which is determined using well established methods of spectral adjustment. These are based on best estimates from models such as Monte Carlo N-Particle (MCNP), input cross-sections, and measured activities from flux wires in the experiment. Each of these parameters can propagate uncertainties which will affect the uncertainty in the calculated dose levels for AGC, or any experiment irradiated within a reactor. While the methods of propagating uncertainty are well-established, the final uncertainty estimates they provide are only as good as the estimates of uncertainty in the inputs on which they are based. The purpose of this work is to outline some deficiencies in the ways these input uncertainties are presently estimated, and to outline a methodology by which they can be improved. The fast fluence and radiation damage received by graphite specimens irradiated in the Advanced Graphite Creep (AGC) experiments is presently estimated using spectral adjustment methods that are based on both flux wire activity measurements, and MCNP model predictions. This work describes an ongoing effort to quantify and propagate uncertainties in inputs to the spectral adjustment process, and thereby quantify the resultant error in radiation damage (dpa) estimates. The effort is multi-faceted, and we consider the impacts of both the set of flux wires selected, and the counting process. An expanded set of flux wires is identified that provides a more comprehensive data set on the fast spectrum. To address the counting process itself, a series of round-robin measurements in several reactor metrology laboratories across the Department of Energy (DOE) complex and nuclear industry are being undertaken to refine the American Society for Testing and Materials (ASTM) standards for flux wire measurements. To address the contribution of uncertainty in the MCNP model predictions, an uncertainty quantification (UQ) tool has been developed that statistically samples the model input parameters, runs a series of cases, and assimilates the results to provide an overall uncertainty. The impact of the MCNP UQ tool results is demonstrated by re-analyzing previous AGC flux wire and irradiation data. While the expanded flux wire set obviously cannot be added to these experiments retroactively, plans for future graphite irradiations are outlined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dose Uncertainty Quantification in AGC Experiment

This memorandum formally documents completion of the Advanced Reactor Technologies Level 3 Milestone (M3NT-18IN060504037), “Interoffice Memorandum detailing status of the AGC irradiation uncertainty analysis” due SeptemberAugust 30, 2018. This memorandum details the progress made toward the issuance of a final report detailing the AGC uncertainty analysis including the proposed methodology, progress on activities, and explanation of how the data will be used. Radiation damage estimation is an important component of the post-irradiation analysis of the AGC experiments. It depends primarily on the fast fluence, which is determined using well-established methods of spectral adjustments. These are based on best estimates from models (e.g. MCNP). Input cross-sections, and measured activities from flux wires in the experiment, propagate uncertainties in each of these. While the methods of propagating uncertainty are well-established, the final uncertainty estimates they provide are only as good as the estimates of uncertainty in the inputs on which they are based. The purpose of this work is to implement a method that eliminates some deficiencies in the ways input uncertainties are presently estimated. The rRadiation damage estimates for the AGC experiments are ostensibly based on experimental data in the form of flux wire activation measurements; each AGC experiment has been instrumented with flux wires at various locations along the axial length to provide this data. However, the estimatesy also depend on the results of MCNP calculations. To understand why, consider that the objective of the analysis is to estimate some number of parameters (the energy group fluences ?_i) that best reproduce the observations (the measured activities of the flux wires a_i).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microstructure and Wear Performance of Cobalt-Containing Iron-Based Slag-Free Self-shielded Flux-Cored Wire

A new type of cobalt-containing iron-based slag-free self-shielded flux-cored wire was developed for hardfacing. The influence of cobalt additions on the microstructure and wear performance of the hardfacing was investigated. The cobalt-containing iron-based hardfacing alloy has a typical hypereutectic microstructure consisting of primary M{sub 7}(C, B){sub 3} carbide, and a eutectic of M{sub 3}(C, B) carbide and austenite (part of which subsequently transformed into martensite). Cobalt promoted the formation of austenite and changed the morphology of the primary carbide and eutectic colonies. The morphology of primary carbide became fragmented with increasing cobalt due to the possible impeding effect of cobalt to the movement of the M{sub 7}(C, B){sub 3}/liquid interface. Different structures of the eutectic carbides were observed—the chrysanthemum structure for 1.42 wt.% cobalt, the skeleton form for 2.88 wt.% cobalt, the radial stripe 4.37 wt.% cobalt and the discrete stripe for 5.75 wt.% cobalt. Wear loss of the hardfacing alloy containing 2.88 wt.% cobalt was the smallest among all the alloys, owing to the large primary large carbide and skeleton-shaped eutectic carbides, the proper amount of austenite phase separating the M{sub 7}(C, B){sub 3} and M{sub 3}(C, B) carbides, the solid solution strengthening by cobalt in the matrix, and the high hardness of the alloy. Moreover, the wear resistance has a tendency to decrease with the increase in velocity as well as load.

36 MATERIALS SCIENCE↗

Validation of the Fast and Thermal Neutron Flux Profiles in the Advanced Test Reactor for the AGR-3/4 Experiment

The AGR-3/4 experiment was designed to irradiate TRISO particle fuel in the Advanced Test Reactor (ATR) at the Idaho National Laboratory. Temperature control of the test capsules containing the TRISO particles was important since the goal was to measure diffusion rates of fission product elements through graphite as a function of temperature. During the experiment, differences were observed between temperatures measured by the thermocouples and temperatures calculated with the thermal analysis model. To rule out the possibility that the used ATR driver fuel elements were the root cause of these temperature differences, an experiment was devised to measure the axial fast and thermal neutron flux profiles in the northeast flux trap containing the AGR-3/4 experiment. An important input parameter to the thermal analysis model was the calculated compact heat rates from the MCNP physics model. To verify these calculated heat rates were consistent with the ATR driver fuel element loading and operating lobe power, axial flux wires were inserted into ATR northeast flux trap. The measured fast and thermal neutron axial flux profiles derived from the flux wire activation showed excellent agreement with the calculated flux profiles. This agreement dispelled any concerns that the used ATR fuel elements in the northeast lobe might have introduced unusual axial flux variation. In addition, the agreement provided a validation basis for the physics calculation, specifically, (1) MCNP physics model, (2) Monte Carlo depletion methodology, (3) method used to load the ATR driver fuel, and (4) ATR measured lobe power data used in the calculation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY 2017 Modeling of the M8 Calibration Series using MAMMOTH

This report provides an overview of the modeling efforts performed in FY17 to validate MAMMOTH using historical TREAT data. The data for comparison comes from the M8 series of calibration measurements, which was the last series performed before TREAT was shut down in 1994. The data set includes: an experiment flux profile; low level steady state power coupling factors for flux wires and fuel pins; and a temperature limited transient. MAMMOTH was able to obtain reasonable results for all cases with the exception of the H91-8-1 flux wire. Because of issues encountered in determination of biases introduced in measurement of power coupling factors, there was insufficient time to model the fuel pins in MAMMOTH. However, the feasibility of doing so was demonstrated with the flux wire calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ATR Fuel Management

The sixth Core Internals Changeout (CIC) of ATR was completed on March 21, 2022, and Nuclear Testing (NT) commenced shortly thereafter. In support of NT, 235U flux wires were attached to flux wands using electrical tape and installed in water channels 2, 6, 11, 15 and 19 in each of the 40 ATR Mark VII fuel elements that comprise an ATR core to perform low power flux measurements during ATR Cycle 170CIC NT-3. The flux wands were fabricated from Poly (Methyl Methacrylate), or PMMA. Irradiated cobalt capsules were loaded in the ATR Northeast Irradiation Housing Assembly (NEIHA), the East Flux Trap (EFT), South Flux Trap (SFT), inboard A-positions and various H-positions as a 170CIC NT-3 core reactivity hold-down mechanism. The PMMA flux wands received significant gamma dose from the irradiated cobalt during NT-3 which caused discoloration, embrittlement and swelling of the flux wands. The removal of the degraded flux wands from the 0.078 in. wide by 50 in. long fuel element coolant channels has been a unique challenge. This presentation summarizes the cleaning techniques used to remove the flux wand debris from the elements, an aggressive PMMA irradiation experiment performed concomitantly with initial cleaning efforts, and planned inspection and qualification techniques that will be applied in the future to potentially requalify the impacted elements for re-use.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WIRE-21 Experiment Irradiation Conditions and In-Situ Data Collection

This report summarizes the in situ data collected during three cycles of irradiation (~75 days) of the Wireless Instrumented Removable Beryllium Experiment 2021 (WIRE-21) in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR). The experiment was designed primarily to evaluate the effects of high neutron flux and fluence on the performance of wireless temperature and pressure sensors being developed by Westinghouse Electric Company (WEC). WEC’s sensors could provide critical data regarding the evolution of centerline temperatures and pressurization due to fission gas release during fuel operation in light-water reactors (LWRs) or various advanced reactor applications. In addition to WEC’s wireless sensors, many other sensors were interrogated, including thermocouples, self-powered neutron detectors (SPNDs), distributed fiber optic temperature sensors, and passive neutron flux wires and silicon carbide thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Design Report for the I2 Instrumentation Experiment in ATRC

The US Department of Energy In-Pile Instrumentation (I2) program is tasked with developing advanced sensors for in-pile service as well as supporting the engineering required to implement existing nuclear sensor technologies in US high-power test reactors. The ATRC instrumentation test has been conceived to address both of these missions, specifically with respect to neutron flux measurements. Space has been allocated in the test for Self-Powered Neutron Detectors (SPNDs), fission chambers, and Micro-Pocket Fission Detectors (MPFDs). The real-time flux readings obtained from these instruments will be compared with time integrated data obtained from passive neutron dosimetry (i.e., “flux” wires). This work will be complementary to data obtained from the TREAT MIMIC-N experiment. This experiment is expected to support instrumentation efforts related to the proposed Medium-I loop and to instrumenting loop experiments conducted in the ATR center flux trap. While the MIMIC-N experiment was conducted in a dry environment, the ATRC I-19 experiment will be conducted in an aqueous environment, similar to the center flux trap loop experiments but will take place at ambient temperature and pressure, and at a much lower neutron flux. One of the challenges of the ATRC I-19 experiment will be low amplitude signals produced by the sensors in the low neutron fluxes of ATRC. However, related work conducted several years ago in ATRC was able to reliably detect signals using a similar instrument set.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CURRENT STATUS OF THE CHARACTERIZATION OF RPV MATERIALS HARVESTED FROM THE DECOMMISSIONED ZION UNIT 1 NUCLEAR POWER PLANT

The decommissioning of Units 1 and 2 of the Zion Nuclear Power Station in Zion, Illinois, after ~ 15 effective full-power years of service presents a unique opportunity to characterize the degradation of in-service reactor pressure vessel (RPV) materials and to assess currently available models for predicting radiation embrittlement of RPV steels [1-3]. Moreover, through-wall thickness attenuation and property distributions are being obtained and the results to be compared with surveillance specimen test data. It is anticipated that these efforts will provide a better understanding of materials degradation associated with extending the lifetime of existing nuclear power plants (NPPs) beyond 60 years of service and subsequent license renewal. In support of extended service and current operations of the US nuclear reactor fleet, the Oak Ridge National Laboratory (ORNL), through the U.S. Department of Energy, Light Water Reactor Sustainability (LWRS) Program, coordinated procurement of materials, components, and other items of interest from the decommissioned Zion NPPs. In this report, harvesting, cutting sample blocks, machining test specimens, test plans, and the current status of materials characterization of the RPV from the decommissioned Zion NPP Unit 1 will be discussed. The primary foci are the circumferential, Linde 80 flux, wire heat 72105 (WF-70) beltline weld and the A533B base metal from the intermediate shell harvested from a region of peak fluence (0.7 X 1019 n/cm2, E > 1.0 MeV) on the internal surface of the Zion Unit 1 vessel. Following the determination of the through-thickness chemical composition, Charpy impact, fracture toughness, tensile, and hardness testing are being performed to characterize the through-thickness mechanical properties of base metal and beltline-weld materials. In addition to mechanical properties, microstructural characterizations are being performed using various microstructural techniques, including Atom Probe Tomography, Small Angle Neutron Scattering, and Positron Annihilation Spectroscopy

Rosseel, T. M.↗

Neutron Dosimetry for the SAM-2 Irradiation in ATR

PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673 and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the SAM-2 irradiation which was conducted in position B8 of the ATR. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and sent to INL for loading into the SAM-2 assembly prior to irradiation. The SAM-2 experiment has 8 capsules labelled A through H designed for different exposures in successive irradiation cycles. This report is for the first three capsules, A, B and C, co-irradiated for 1 cycle. The remaining capsules and fluence monitors will be removed and analyzed after additional irradiation. Following irradiation, the fluence monitors from capsules A, B, and C were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗