Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence thermometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nitric Oxide Laser-Induced Fluorescence Rotational Thermometry in a Hypersonic Non-Equilibrium Flow

Spatially-resolved nitric oxide (NO) planar laser-induced fluorescence (PLIF) rotational thermometry was performed on a Mach 5 non-equilibrium flow around a blunt-body specimen in the Hypersonic Materials Environmental Test System (HyMETS) arc-heat wind tunnel at the NASA Langley Research Center. Transitions within the (0,0) band in the A(exp⁡ 2)∑(sup⁡ +) - X(exp⁡ 2)Π system of NO were excited with a 10 Hz pulsed ultra-violet laser. A multi-line fitting algorithm was applied to the PLIF spectra and transitions were filtered based on an iterative method that maximizes thermometry accuracy. NO PLIF thermometry results are compared to non-equilibrium computational fluid dynamics (CFD) simulations reported in the literature. Differences between the experiment and CFD are quantified for the free-stream, post-shock, shear-layer, and expansion-fan regions of the flow. Potential sources of error, applicable to both the CFD and experiment, are discussed.

Connor C McDougall↗

Nitric Oxide Planar Laser Induced Fluorescence Rotational Thermometry Characterization of A Hypersonic Boundary Layer

Nitric oxide (NO) planar laser-induced fluorescence (PLIF) was performed to determine rotational temperature profiles and fluctuations within a hypersonic boundary layer above the surface of a 2.75° half-angle wedge. The experiments were performed in the Texas A&M University Actively Controlled Expansion (ACE) hypersonic blow-down wind tunnel at Mach = 5.7 and 𝑅𝑒 = 6 × 10 6 /m. The NO was introduced to the flow in the settling chamber of the ACE tunnel and probed using two laser sheets near 226 nm. The resulting NO PLIF fluorescence signal was acquired using in-house software, which simultaneously recorded tunnel conditions. After a Fast Fourier Transform (FFT) blurring and statistical treatment was performed, the preshock temperature was evaluated to be 58 ± 2 K (3.5%), while the turbulent boundary layer temperature near the wall was found to be 350 K with fluctuations on the order of ±25 K (7%). The relative temperature fluctuations were determined to be 3 − 5% in the freestream and peaked at 33% in the turbulent boundary layer. The advantages and disadvantages of seeding NO in the tunnel settling chamber for thermometric PLIF measurements are discussed.

Hypersonics↗

Atomic fluorescence study of high temperature aerodynamic levitation

Ultraviolet laser induced atomic fluorescence has been used to characterize supersonic jet aerodynamic levitation experiments. The levitated specimen was a 0.4 cm sapphire sphere that was separately heated at temperatures up to 2327 K by an infrared laser. The supersonic jet expansion and thermal gradients in the specimen wake were studied by measuring spatial variations in the concentration of atomic Hg added to the levitating argon gas stream. Further applications of atomic fluorescence in containerless experiments, such as ideal gas fluorescence thermometry and containerless process control are discussed.

Nordine, P. C.↗

Fluorescence spectroscopy and thermometry for hypersonic flight research

The present study, which has demonstrated the feasibility of using time-resolved laser-induced fluorescence methods to ascertain boundary layer temperature distributions in real time for hypersonic vehicles in atmospheric flight, employs conventional optics in combination with novel time-resolved spectroscopy. The radiative lifetime and signal intensity involved, both of which are reduced by quenching, are adequate for measurement with state-of-the-art time-resolved fluorescence techniques, except for certain conditions associated with both the highest speeds and the lowest altitudes.

Thompson, B. E.↗

Laser-induced fluorescence of phosphors for remote cryogenic thermometry

Remote cryogenic temperature measurements can be made by inducing fluorescence in phosphors with temperature-dependent emissions and measuring the emission lifetimes. The thermographic phosphor technique can be used for making precision, noncontact, cryogenic-temperature measurements in electrically hostile environments, such as high dc electric or magnetic fields. The National Aeronautics and Space Administration is interested in using these thermographic phosphors for mapping hot spots on cryogenic tank walls. Europium-doped lanthanum oxysulfide (La2O2S:Eu) and magnesium fluorogermanate doped with manganese (Mg4FGeO6:Mn) are suitable for low-temperature surface thermometry. Several emission lines, excited by a 337-nm ultraviolet laser, provide fluorescence lifetimes having logarithmic dependence with temperature from 4 to above 125 K. A calibration curve for both La2O2S:Eu and Mg4FGeO6:Mn is presented, as well as emission spectra taken at room temperature and 11 K.

Beshears, D. L.↗

Laser-induced fluorescence of phosphors for remote cryogenic thermometry

Remote cryogenic temperature measurements can be made by inducing fluorescence in phosphors with temperature-dependent emissions and measuring the emission lifetimes. The thermographic phosphor technique can be used for making precision, noncontact, cryogenic-temperature measurements in electrically hostile environments, such as high dc electric or magnetic fields. The National Aeronautics and Space Administration is interested in using these thermographic phosphors for mapping hot spots on cryogenic tank walls. Europium-doped lanthanum oxysulfide (La2O2S:Eu) and magnesium fluorogermanate doped with manganese (Mg4FGeO6:Mn) are suitable for low-temperature surface thermometry. Several emission lines, excited by a 337-nm ultraviolet laser, provide fluorescence lifetimes having logarithmic dependence with temperature from 4 to above 125 K. A calibration curve for both La2O2S:Eu and Mg4FGeO6:Mn is presented, as well as emission spectra taken at room temperature and 11 K.

Beshears, D. L.↗

10-kHz PLIF Thermometry for Turbulent Jet Flame using Single Burst-mode OPO

Two-color Planar Laser-Induced Fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to 285.62 nm and 285.67 nm to excite the Q2(12) andP1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.

thermometry↗

10-kHz PLIF Thermometry for a Turbulent Jet Flame using Single Burst-mode OPO

Two-color Planar laser-induced fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to285.62 nm and 285.67 nm to excite the Q2(12) and P1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.

thermometry↗

Single-pulse gas thermometry at low temperatures using two-photon laser-induced fluorescence in NO-N2 mixtures

A technique suitable for measuring fluctuating temperatures in supersonic turbulent flows of N2 seeded with NO has been demonstrated in a nonflowing cell. The method relies on the two photon excitation of two selected ro-vibronic transitions in the NO gamma (alpha 2 sigma+, v prime = 0 yields ch1zp1, v double prime = 0). Previously announced in STAR as N83-20079

Gross, K. P.↗

Containerless Atomic-Fluorescence Property Measurements

Report describes studies conducted to establish and verify use of laser-induced fluorescence in monitoring and controlling high-temperature containerless processes. Specimens levitated by gas jets or electromagnetic fields and heated by laser beams or electromagnetic induction while being irradiated and detected by fluorescence technique. Makes quantitative and qualitative comparisons among three new methods of temperature measurement; all rely on laser-induced fluorescence. One method gas-density thermometry with seed gas. Other two methods involve measurements of velocities of evaporating atoms or of population ratios of different electronic states.

Nordine, P.↗

From Wind Tunnels to Flight Vehicles: Visualization and quantitative measurements supporting NASA’s space program

NASA’s Space Launch System (SLS) and Orion Crew Module have been studied in wind tunnels using the planar laser-induced fluorescence (PLIF) technique for flow visualization and quantitative thermometry and in flight using high-resolution imagery and quantitative infrared surface heating measurements. This paper reviews both types of measurements. OCIS codes: (120.1740) Combustion diagnostics; (300.2530) Fluorescence, laser-induced; (110.3080) Infrared imaging.

Planar Laser-Induced Fluorescence (PLIF)↗

Non-contact temperature measurement

Three methods for noncontact temperature measurement are presented. Ideal gas thermometry is realized by using laser-induced fluorescence to measure the concentration of mercury atoms in a Hg-Ar mixture in the vicinity of hot specimens. Emission polarimetry is investigated by measuring the spatially resolved intensities of polarized light from a hot tungsten sphere. Laser polarimetry is used to measure the optical properties, emissivity, and, in combination with optical pyrometry, the temperature of electromagnetically levitated liquid aluminum. The precision of temperature measurements based on the ideal gas law is + or - 2.6 percent at 1500-2000 K. The polarized emission technique is found to have the capability to determine optical properties and/or spectral emissivities of specimens over a wide range of wavelengths with quite simple instruments.

Nordine, Paul C.↗

Laser Optogalvanic Spectroscopy pf Neon and Argon in a Discharge Plasma and its Significance for Microgravity Combustion

A detailed study of combustion mechanisms in flames, employing laser-based diagnostics, has provided good knowledge and understanding of the physical phenomena, and led to better characterization of the dynamical and chemical combustion processes, both under low-gravity (in space) and normal gravity (in ground based facilities, e.g. drop towers). Laser induced fluorescence (LIF), laser-induced incandescence (LII) and LIF thermometry have been widely used to perform nonintrusive measurements and to better understand combustion phenomena. Laser optogalvanic (LOG) spectroscopy has well-established applications in ion mobility measurements, atomic and molecular spectroscopy, ionization rates, recombination rates, velocity measurements and as a combustion probe for trace element detection. Absorption spectra of atomic and molecular species in flames can be obtained via LOG spectroscopy by measuring the voltage and current changes induced by laser irradiation. There are different kinds of processes that contribute to a discharge current, namely: (1) electron impact ionization, (2) collisions among the excited atoms of the discharge species and (3) Penning ionization. In general, at higher discharge currents, the mechanism of electron impact ionization dominates over Penning ionization, whereby the latter is hardly noticeable. In a plasma, whenever the wavelength of a laser coincides with the absorption of an atomic or molecular species, the rate of ionization of the species momentarily increases or decreases due to laser-assisted acceleration of collisional ionization. Such a rate of change in the ionization is monitored as a variation in the transient current by inserting a high voltage electrode into the plasma. Optogalvanic spectroscopy in discharges has been useful for characterizing laser line-widths and for providing convenient calibration lines for tunable dye lasers in the ultraviolet, visible and infrared wavelength regions. Different kinds of quantitative information, such as the electron collisional ionization rate, can be extracted from the complex processes occurring within the discharge. In the optogalvanic effect (OGE), there is no problem of overlap from background emissions, and hence even weak signals can be detected with a high signal-to-noise ratio, which makes the optogalvanic effect sensitive enough to resolve vibrational changes in molecular bonds and differences in energy levels brought about by different electron spins. For calibration purposes, neon and argon gaseous discharges have been employed most extensively, because these gases are commonly used as buffer gases within hollow-cathode lamps and provide an acceptable density of calibration lines. In the present work, our main aim has been to understand the dominant physical processes responsible for the production of the OGE signal, based on the extensive time resolved optogalvanic waveforms recorded, and also to extract quantitative information on the rates of excited state collisional processes.

Misra, Prabhakar↗

NO PLIF Rotational Thermometry Characterization of a Hypersonic Boundary Layer

Nitric oxide (NO) planar laser-induced fluorescence (PLIF) was performed to determine rotational temperature profiles and fluctuations within a hypersonic boundary layer above the surface of a 2.75° half-angle wedge. The experiments were performed in the Texas A&M University Actively Controlled Expansion (ACE) hypersonic blow-down wind tunnel at Mach = 5.7 and 𝑅𝑒 = 6 × 10 6 /m. The NO was introduced to the flow in the settling chamber of the ACE tunnel and probed using two laser sheets near 226 nm. The resulting NO PLIF fluorescence signal was acquired using in-house software, which simultaneously recorded tunnel conditions. After a Fast Fourier Transform (FFT) blurring and statistical treatment was performed, the preshock temperature was evaluated to be 58 ± 2 K (3.5%), while the turbulent boundary layer temperature near the wall was found to be 350 K with fluctuations on the order of ±25 K (7%). The relative temperature fluctuations were determined to be 3 − 5% in the freestream and peaked at 33% in the turbulent boundary layer. The advantages and disadvantages of seeding NO in the tunnel settling chamber for thermometric PLIF measurements are discussed.

Hypersonics↗

High Temperature Thermographic Phosphor Coatings Development

For many years, phosphor thermometry has been used for non-contact temperature measurements. A large number of applications have been associated with high temperatures, especially for aerospace systems where blackbody radiation backgrounds are large and in challenging environments, such as vibration, rotation, flame, or noise. These environments restrict the use of more common thermocouples or infrared thermometric techniques. In particular, temperature measurements inside jet turbines, rocket engines, or similar devices are especially amenable to phosphor techniques. Often the fluorescent materials are used as powders, either suspended in binders and applied like paint or applied as high-temperature sprays. Thin coatings that are less than 50 m thick are used on the surfaces of interest. These coatings will quickly assume the same temperature as the surface to which they are applied. The temperature dependence of fluorescent materials is a function of the base matrix atoms and a small quantity of added activator or dopant ions. Often for high temperature applications, the selected materials are refractory and include rare earth ions. Phosphors like Y3Al5O12 (YAG) doped with Eu, Dy, or Tm, Y2O3 doped with Eu, or similar rare earth compounds, will survive high temperatures and can be configured to emit light that changes rapidly in lifetime and intensity. For example, researchers at Oak Ridge National Laboratory recently observed fluorescence from YAG:Dy and YAG:Tm at temperatures above 1400 C. One of the biggest challenges is to locate a binder material that can withstand tremendous variations in temperature in an adverse aerospace environment. This poster will provide an overview into our attempt to utilize phosphors for thermometry purposes. Emphasis will be placed on the use of selected binder materials that can withstand high temperatures. This research was completed for the National Aeronautics and Space Administration's Glenn Research Center in Cleveland, Ohio.

Goedeke, Shawn↗

Quantitative Analysis of Planar Laser-Induced Fluorescence Measurements in a Hypersonic Boundary Layer

Several quantitative measurements extracted from nitric oxide (NO) planar laser-induced fluorescence (PLIF) data obtained in a hypersonic boundary layer are reported: (a) off-body NO mole fraction; (b) surface heat flux; and (c) near-wall static temperature. The experimental data was obtained at NASA Langley Research Center’s 31 in. Mach 10 air tunnel. NO was seeded into the flow through a spanwise slot on the surface of the 10 degree half-angle wedge model. An ultraviolet planar laser sheet was positioned perpendicular to the wedge surface, downstream of the seeding slot, to excite six fluorescence transitions. A method for extracting the relative NO mole fraction, based on spatial variations of the J”= 0.5 PLIF signal, is presented. Combined with the principle of mass conservation, the absolute NO mole fraction is determined. These measurements were used to assess CFD diffusion modelling, correct previously reported PLIF thermometry results, and develop methods for NO-PLIF heat transfer measurements.

McDougall, Connor C.↗

100 kHz High-Spectral-Resolution NO-PLIF Measurements for Compressible Flows

In the present work, we use a burst-mode laser and optical parametric oscillator system to perform high-spectral resolution NO-PLIF measurements of an underexpanded jet at a repetition-rate of 100 kHz, with the motivation of multi-parameter measurements of temperature, pressure, and velocity. The laser frequency of the 1064 nm seed laser for the burst-mode laser was scanned during the burst to cover two neighboring absorption line pairs near 226 nm. The peak PLIF signal intensity varies along the axial (z) direction of the underexpanded jet as the laser frequency is scanned, which we attribute to the collisional shift induced by the flow and only revealed due to the narrow linewidth of the laser. A pseudo-Voight fit is applied to the LIF excitation spectra on a pixel-by-pixel basis to measure the spectral position of the peak intensity for the two transition pairs and their amplitude. The spectral position of the peak intensity is used to derive a frequency shift, which is separated into its collisional and Doppler components using the axisymmetric nature of the flow field. The amplitude of the measured peaks is used for two-line rotational thermometry. Challenges for quantitative measurements using such an approach are discussed, including measuring the spatial variations in the energy distribution of the laser sheet at a 100 kHz repetition rate and uncertainty/variability in the step size during the fast frequency scan.

laser induced fluorescence↗