Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescein”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Phase conjugation by degenerate four wave mixing in disodium fluorescein solution in methanol

Organic dyes are known to show the resonant type of nonlinear optical properties, including phase conjugation. In the present work, disodium fluorescein in methanol is used as an organic nonlinear medium for degenerate four wave mixing at 532 nm to see the intensity dependence of the phase conjugate signal at different concentrations of the solution. It is observed that the maximum reflectivity of the signal occurs in a concentration range of 5 x 10(exp -3)/cu cm to 1.2 x 10(exp -2) g/cu cm. It is also observed that the intensity of the signal drops suddenly to less than half of its maximum outside the concentration range mentioned above. An investigation of the phase conjugate signal intensity by changing the delay time between probe signal and the forward pump is also examined. Briefly discussed is the possibility of population grating in dye liquids as a source of enhancing the third order susceptibility besides the other techniques mentioned in reference. The experiment is done by beam splitting the second harmonic (532 nm) of Nd:YAG laser, Q-switched at 20 pulses/sec (pulse width is approximately 8 and 200 mJ per pulse).

Abdeldayem, Hossin↗

Retinal Image Quality Assessment for Spaceflight-Induced Vision Impairment Study

Long-term exposure to space microgravity poses significant risks for visual impairment. Evidence suggests such vision changes are linked to cephalad fluid shifts, prompting a need to directly quantify microgravity-induced retinal vascular changes. The quality of retinal images used for such vascular remodeling analysis, however, is dependent on imaging methodology. For our exploratory study, we hypothesized that retinal images captured using fluorescein imaging methodologies would be of higher quality in comparison to images captured without fluorescein. A semi-automated image quality assessment was developed using Vessel Generation Analysis (VESGEN) software and MATLAB® image analysis toolboxes. An analysis of ten images found that the fluorescein imaging modality provided a 36% increase in overall image quality (two-tailed p=0.089) in comparison to nonfluorescein imaging techniques.

retina↗

EGS Collab Testbed 1: Second Set Tracer Test Results

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. The first multi-well experimental site was established at the 4850 level in the Homestake Mine in Lead, South Dakota, where hydraulic fractures were created at an injection well drilled sub-horizontal from the drift. This file contains the second set of tracer data (also include the data uploaded previously, https://gdr.openei.org/submissions/1128) for the EGS Collab testbed. The tracer tests were conducted during October 2018 - November 2019. Injected tracers include DNA, C-dots (fluorescein nano particles), fluorescein, rhodamine-b, sodium chloride, lithium bromide and cesium iodine. The tracers have been detected in three flowing wells located about 7.5 to 9 meters away from the injection interval. The tracer breakthrough curves from these locations have been adjusted to account for the residence time in the injection and production tubing. The details about the tracer test can be found in Background and Methods of Tracer Tests (Mattson et al. (2019,a,b)) (also included in this package). References Mattson, E.D., Neupane, G., Plummer, M.A., Hawkins, A., Zhang, Y. and the EGS Collab Team 2019a. Preliminary Collab fracture characterization results from flow and tracer testing efforts. In Proceedings 44th Workshop on Geothermal Reservoir Engineering, edited, Stanford University, Stanford, California. Mattson, E.D., Neupane, G., Hawkins, A., Burghardt, J., Ingraham, M., Plummer, M., and the EGS Collab Team, 2019b. Fracture tracer injection response to pressure perturbations at an injection well. GRC Transactions, Vol. 43, 2019. Neupane, Ghanashyam, Earl Mattson, Adam Hawkins, Mitchell Plummer, and Yuran Zhang. EGS Collab Testbed 1: Tracer data sets. No. 1128. DOE Geothermal Data Repository; Idaho National Laboratory, 2019.

15 GEOTHERMAL ENERGY↗

One-electron redox kinetics of aqueous transition metal couples Zn 2+/+ , Co 2+/+ , and Ni 2+/+ using pulse radiolysis

The one-electron redox potentials for aqueous metal couples Co 2+/+ and Ni 2+/+ have been investigated by using pulse radiolysis using their reactions with a series of reference compounds to establish the most positive upper limits of E 0 . Experiments with Zn + were also carried out to confirm the characteristic shape of the expected reduction kinetics. Both formate ions and t-BuOH were employed to scavenge ˙OH radicals and ˙H atoms. Kinetics and fitted first and second order reaction rates have been reported for reactions with methyl viologen, fluorescein, Ru(NH 3 ) 6 3+ , Co(en) 3 2+ , Co(sepulcrate) 3+ , Ru(bpy) 3 2+ , Cr(bpy)33+, and Ni(Me 6 [14]4,11-dieneN4) 2+ . Previous work demonstrated that both Co 2+ and Ni 2+ can be reduced by CO 2 ˙- radicals, giving a negative E 0 limit of -1.9 V vs. SHE. A definite reaction of Ni + with fluorescein di-anions provides a new upper limit of the Ni 2+/+ couple as -0.906 V vs. SHE. The reaction of Co + with Ru(bpy) 3 2+ has been confirmed, giving E 0 = -1.3 V vs. SHE as a rigorous upper limit of the Co 2+/+ couple. In the case of Co 2+/+ , kinetics were complicated by a self-catalyzed metal clustering phenomenon. Initiation rate constants of this process have also been reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects on the Ocular Surface from Reading on Different Smartphone Screens: A Prospective Randomized Controlled Study

The purpose of this study was to investigate the influence of smartphone reading on the ocular surface and to compare the various effects of different screens and light conditions on the ocular surface. One hundred nineteen volunteers were randomly divided into: light + organic light‐emitting diode (OLED), light + electronic ink (eINK), dark + OLED, and dark + eINK. Ocular surface examinations, including noninvasive break‐up time (NIBUT), noninvasive keratograph tear meniscus height (NIKTMH), ocular redness, fluorescein break‐up time (FBUT), corneal fluorescein staining, meibomian gland assessment, Schirmer I Test, and blinking frequency, were performed before and after a reading task. Symptoms were evaluated using the Ocular Surface Disease Index (OSDI) and Computer Vision Syndrome Questionnaire (CVS‐Q). NIBUT and FBUT were decreased statistically significantly after participants read on an OLED screen for 2 hours compared with the baseline in light and dark environments, whereas no statistically significant decrease was observed on an eINK screen. NIKTMH was statistically significantly decreased after reading on an OLED screen in light and dark settings, and the eINK screen had a lesser effect on NIKTMH. An obvious increase in the ocular redness, OSDI and CVS‐Q scores was observed after reading on an OLED screen, whereas the eINK screen had a lesser effect on these indicators. Blink rate increased gradually in OLED subgroups during the reading task, whereas no statistically significant difference was observed in the eINK subgroups. Our research suggested that reading on an OLED screen can cause ocular surface disorder and obvious subjective discomfort, whereas reading on an eINK screen can minimize ocular surface disorder in both dark and light environments.

Yuan, Kelan↗

Fish scale-loss caused by simulated hydraulic shear stress

Riverine fishes found within streams impacted by hydropower also often pass through hydropower turbines during annual downstream migrations. During turbine passage events, fish may experience a suite of stressors including rapid pressure changes, impacts from turbine blades, and exposure to hydraulic shear. Scale-loss is often observed in fish collected below dams and hydraulic shear is the most likely cause of this trauma. While exposure to shear may cause other injuries, scale-loss appears to be the most common non-lethal injury observed to date. We sought to quantify how hydraulic shear may cause scale-loss in rainbow trout, gizzard shad, and hybrid striped bass by precisely controlling the exposure level (velocity) and duration (seconds) of a water jet. We targeted the same area for all three species found between the operculum and dorsal fin on the left, lateral surface. Exposure velocities ranged from 0 (controls) to 11.0 meters/second but fish were only exposed to the water jet for 1.5 seconds. A 0.2 milligram/milliliter solution of fluorescein was used to stain the areas of scale-loss by submerging each fish in this solution for at least 6 minutes. Fluorescein was used because it interacts with epithelial tissue that has been damaged and it fluoresces under ultraviolet lighting. Fish were photographed under short- and longwave ultraviolet lighting in a dark chamber to capture fluorescence. Fish photographs were analyzed using ImageJ and the proportion of descaled area was estimated for each fish within a 35 by 35-millimeter square. In general, these data highlight how exposure to hydraulic shear may lead to significant levels of descaling in riverine fishes.

13 HYDRO ENERGY↗

Late ophthalmological complications after total body irradiation in non-human primates

PURPOSE: To investigate the long-term effects of total body irradiation (TBI) on the incidence and time course of ocular complications. MATERIALS AND METHODS: Rhesus monkeys treated with TBI photon doses up to 8.5 Gy and proton doses up to 7.5 Gy were studied at intervals up to 25 years post-irradiation. They were compared with control groups with a similar age distribution. Cataract formation and ocular fundus lesions were scored according to a standardized protocol. Fluorescein angiography and histopathology was performed in selected animals. RESULTS: Cataract formation occurred after a latent period of 3-5 years. Significant cataract induction was observed for photon-doses of 8 and 8.5 Gy and beyond 20 years after proton irradiation. The severity of the lesions represents significant impairment of vision and would require cataract surgery if similar results occurred in human bone marrow transplant patients. Fluorescein angiography demonstrated a normal pattern of retinal vessels in 13 out of 14 animals (93%) from the irradiated group and in eight out of nine animals (89%) from the control group. No additional lesions apart from age-related degenerative changes could be demonstrated. Histological evaluation revealed no radiation-associated vasculopathy. CONCLUSIONS: Radiation alone for doses up to 8.5 Gy of photons does not carry a potential risk for fundus pathology, whereas clinically important cataract induction should be anticipated within 5 years after photon doses of 8.0 and 8.5 Gy and proton doses in excess of 2.5 Gy.

NASA Discipline Radiation Health↗

Sensitive detection of Escherichia coli O157:H7 in food and water by immunomagnetic separation and solid-phase laser cytometry

Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.

Non-NASA Center↗

Fluorescence-Doped Particles for Simultaneous Temperature and Velocity Imaging

Polystyrene latex microspheres (PSLs) have been used for particle image velocimetry (PIV) and laser Doppler velocimetry (LDV) measurements for several decades. With advances in laser technologies, instrumentation, and data processing, the capability to collect more information about fluid flow beyond velocity is possible using new seed materials. To provide additional measurement capability, PSLs were synthesized with temperature-sensitive fluorescent dyes incorporated within the particle. These multifunctional PSLs would have the greatest impact if they could be used in large scale facilities with minimal modification to the facilities or the existing instrumentation. Consequently, several potential dyes were identified that were amenable to existing laser systems currently utilized in wind tunnels at NASA Langley Research Center as well as other wind and fluid (water) tunnels. PSLs incorporated with Rhodamine B, dichlorofluorescein (DCF, also known as fluorescein 548 or fluorescein 27) and other dyes were synthesized and characterized for morphology and spectral properties. The resulting particles were demonstrated to exhibit fluorescent emission, which would enable determination of both fluid velocity and temperature. They also would allow near-wall velocity measurements whereas laser scatter from surfaces currently prevents near-wall measurements using undoped seed materials. Preliminary results in a wind tunnel facility located at Virginia Polytechnic Institute and State University (Virginia Tech) have verified fluorescent signal detection and temperature sensitivity of fluorophore-doped PSLs.

Danehy, Paul M.↗

NF-κB activation in retinal microglia is involved in the inflammatory and neovascularization signaling in laser-induced choroidal neovascularization in mice

Highlights: • IMD0354 treatment reduced the microglia infiltration, fluorescein leakage and size of the laser CNV spots. • IKK2 inhibition suppressed phospho-IκBα, VEGF-A, and COX-2 in the Laser CNV mouse eyes. • IMD-0354 treated eyes demonstrated reduced microglial migration to the laser injury site. • In vitro, IKK2 inhibition reduced NF-κB activation, COX-2, Actin-F presence, and the microglia cells' migration capacity. To evaluate Nuclear Factor NF-κB (NF-κB) signaling on microglia activation, migration, and angiogenesis in laser-induced choroidal neovascularization (CNV).

60 APPLIED LIFE SCIENCES↗

TGF-beta1 release from biodegradable polymer microparticles: its effects on marrow stromal osteoblast function

BACKGROUND: Controlled release of transforming growth factor-beta1 (TGF-beta1) to a bone defect may be beneficial for the induction of a bone regeneration cascade. The objectives of this work were to assess the feasibility of using biodegradable polymer microparticles as carriers for controlled TGF-beta1 delivery and the effects of released TGF-beta1 on the proliferation and differentiation of marrow stromal cells in vitro. METHODS: Recombinant human TGF-beta1 was incorporated into microparticles of blends of poly(DL-lactic-co-glycolic acid) (PLGA) and poly(ethylene glycol) (PEG). Fluorescein isothiocynate-labeled bovine serum albumin (FITC-BSA) was co-encapsulated as a porogen. The effects of PEG content (0, 1, or 5% by weight [wt%]) and buffer pH (3, 5, or 7.4) on the protein release kinetics and the degradation of PLGA were determined in vitro for as long as 28 days. Rat marrow stromal cells were seeded on a biodegradable poly(propylene fumarate) (PPF) substrate. The dose response and biological activity of released TGF-beta1 was determined after 3 days in culture. The effects of TGF-beta1 released from PLGA/PEG microparticles on marrow stromal cell proliferation and osteoblastic differentiation were assessed during a 21-day period. RESULTS: TGF-beta1 was encapsulated along with FITC-BSA into PLGA/PEG blend microparticles and released in a multiphasic fashion including an initial burst for as long as 28 days in vitro. Increasing the initial PEG content resulted in a decreased cumulative mass of released proteins. Aggregation of FITC-BSA occurred at lower buffer pH, which led to decreased release rates of both proteins. The degradation of PLGA was increased at higher PEG content and significantly accelerated at acidic pH conditions. Rat marrow stromal cells cultured on PPF substrates showed a dose response to TGF-beta1 released from the microparticles similar to that of added TGF-beta1, indicating that the activity of TGF-beta1 was retained during microparticle fabrication and after growth factor release. At an optimal TGF-beta1 dosage of 1.0 ng/ml after 3 days, the released TGF-beta1 enhanced the proliferation and osteoblastic differentiation of marrow stromal cells over 21 days of culture, with increased total cell number, alkaline phosphatase activity, and osteocalcin production. CONCLUSIONS: PLGA/PEG blend microparticles can serve as delivery vehicles for controlled release of TGF-beta1, and the released growth factor enhances marrow stromal cell proliferation and osteoblastic differentiation in vitro. CLINICAL RELEVANCE: Controlled release of TGF-beta1 from PLGA/PEG microparticles is representative of emerging tissue engineering technologies that may modulate cellular responses to encourage bone regeneration at a skeletal defect site.

Non-NASA Center↗

Microfabricated capillary electrophoresis amino acid chirality analyzer for extraterrestrial exploration

Chiral separations of fluorescein isothiocyanate-labeled amino acids have been performed on a microfabricated capillary electrophoresis chip to explore the feasibility of using such devices to analyze for extinct or extant life signs in extraterrestrial environments. The test system consists of a folded electrophoresis channel (19.0 cm long x 150 microns wide x 20 microns deep) that was photolithographically fabricated in a 10-cm-diameter glass wafer sandwich, coupled to a laser-excited confocal fluorescence detection apparatus providing subattomole sensitivity. Using a sodium dodecyl sulfate/gamma-cyclodextrin pH 10.0 carbonate electrophoresis buffer and a separation voltage of 550 V/cm at 10 degrees C, baseline resolution was observed for Val, Ala, Glu, and Asp enantiomers and Gly in only 4 min. Enantiomeric ratios were determined for amino acids extracted from the Murchison meteorite, and these values closely matched values determined by HPLC. These results demonstrate the feasibility of using microfabricated lab-on-a-chip systems to analyze extraterrestrial samples for amino acids.

NASA Discipline Life Sciences Technologies↗

A double fluorescence staining protocol to determine the cross-sectional area of myofibers using image analysis

A double fluorescence staining protocol was developed to facilitate computer based image analysis. Myofibers from experimentally treated (irradiated) and control growing turkey skeletal muscle were labeled with the anti-myosin antibody MF-20 and detected using fluorescein-5-isothiocyanate (FITC). Extracellular material was stained with concanavalin A (ConA)-Texas red. The cross-sectional area of the myofibers was determined by calculating the number of pixels (0.83 mu m(2)) overlying each myofiber after subtracting the ConA-Texas red image from the MF-20-FITC image for each region of interest. As expected, myofibers in the irradiated muscle were smaller (P < 0.05) than those in the non-irradiated muscle. This double fluorescence staining protocol combined with image analysis is accurate and less labor-intensive than classical procedures for determining the cross-sectional area of myofibers.

Non-NASA Center↗

High-Performance Hemofiltration via Molecular Sieving and Ultra-Low Friction in Carbon Nanotube Capillary Membranes

Conventional dialyzer membranes typically comprise of unevenly distributed polydisperse, tortuous, rough pores, embedded in relatively thick ≈20–50 µm polymer layers wherein separation occurs via size exclusion as well as differences in diffusivity of the permeating species. However, transport in such polymeric pores is increasingly hindered as the molecule size approaches the pore dimension, resulting in significant retention of undesirable middle molecules (≥15–60 kDa) and uremic toxins. Enhanced removal of middle molecules is usually accompanied by high albumin loss (≈66 kDa) causing hypoalbuminemia. Here, the scalable bottom-up fabrication of wafer-scale carbon nanotube (CNT) membranes with highly aligned, low-friction, straight-channels/capillaries and narrow pore-diameter distributions (≈0.5–4.5 nm) is demonstrated, to overcome persistent challenges in hemofiltration/hemodialysis. Using fluorescein isothiocyanate (FITC)-Ficoll 70 and albumin in phosphate buffered saline (PBS) as well as in bovine blood plasma, it is shown that CNT membranes can allow for significantly higher hydraulic permeability (more than an order of magnitude when normalized to pore area) than commercial high-flux hemofiltration/hemodialysis membranes (HF 400), as well as greatly enhance removal of middle molecules while maintaining comparable albumin retention. These findings are rationalized via an N-pore transport model that highlights the critical role of molecular flexing and deformation during size-selective transport within nanoscale confinements of the CNTs. In conclusion, the unique transport characteristics of CNTs coupled with size-exclusion and wafer-scale fabrication offer transformative advances for hemofiltration, and the obtained insight into molecular transport can aid advancements in several other bio-systems/applications beyond hemofiltration/hemodialysis.

36 MATERIALS SCIENCE↗