Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Flow visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Flow visualization

Flow visualization techniques are reviewed, with particular attention given to those applicable to liquid helium flows. Three techniques capable of obtaining qualitative and quantitative measurements of complex 3D flow fields are discussed including focusing schlieren, particle image volocimetry, and holocinematography (HCV). It is concluded that the HCV appears to be uniquely capable of obtaining full time-varying, 3D velocity field data, but is limited to the low speeds typical of liquid helium facilities.

Weinstein, Leonard M.

Application of Least-Squares Adjustment Technique to Geometric Camera Calibration and Photogrammetric Flow Visualization

Flow visualization produces data in the form of two-dimensional images. If the optical components of a camera system are perfect, the transformation equations between the two-dimensional image and the three-dimensional object space are linear and easy to solve. However, real camera lenses introduce nonlinear distortions that affect the accuracy of transformation unless proper corrections are applied. An iterative least-squares adjustment algorithm is developed to solve the nonlinear transformation equations incorporated with distortion corrections. Experimental applications demonstrate that a relative precision on the order of 40,000 is achievable without tedious laboratory calibrations of the camera.

Chen, Fang-Jenq

Flow visualization and flow field measurements of a 1/12 scale tilt rotor aircraft in hover

The results are given of flow visualization studies and inflow velocity field measurements performed on a 1/12 scale model of the XV-15 tilt rotor aircraft in the hover mode. The complex recirculating flow due to the rotor-wake-body interactions characteristic of tilt rotors was studied visually using neutrally buoyant soap bubbles and quantitatively using hot wire anemometry. Still and video photography were used to record the flow patterns. Analysis of the photos and video provided information on the physical dimensions of the recirculating fountain flow and on details of the flow including the relative unsteadiness and turbulence characteristics of the flow. Recirculating flows were also observed along the length of the fuselage. Hot wire anemometry results indicate that the wing under the rotor acts to obstruct the inflow causing a deficit in the inflow velocities over the inboard region of the model. Hot wire anemometry also shows that the turbulence intensities in the inflow are much higher in the recirculating fountain reingestion zone.

Coffen, Charles D.

Flow visualization and flow field measurements of a 1/12 scale tilt rotor aircraft in hover

The results are given of flow visualization studies and inflow velocity field measurements performed on a 1/12 scale model of the XV-15 tilt rotor aircraft in the hover mode. The complex recirculating flow due to the rotor-wake-body interactions characteristic of tilt rotors was studied visually using neutrally buoyant soap bubbles and quantitatively using hot wire anemometry. Still and video photography were used to record the flow patterns. Analysis of the photos and video provided information on the physical dimensions of the recirculating fountain flow and on details of the flow including the relative unsteadiness and turbulence characteristics of the flow. Recirculating flows were also observed along the length of the fuselage. Hot wire anemometry results indicate that the wing under the rotor acts to obstruct the inflow causing a deficit in the inflow velocities over the inboard region of the model. Hot wire anemometry also shows that the turbulence intensities in the inflow are much higher in the recirculating fountain reingestion zone.

Coffen, Charles D.

Surface flow visualization of separated flows on the forebody of an F-18 aircraft and wind-tunnel model

A method of in-flight surface flow visualization similar to wind-tunnel-model oil flows is described for cases where photo-chase planes or onboard photography are not practical. This method, used on an F-18 aircraft in flight at high angles of attack, clearly showed surface flow streamlines in the fuselage forebody. Vortex separation and reattachment lines were identified with this method and documented using postflight photography. Surface flow angles measured at the 90 and 270 degrees meridians show excellent agreement with the wind tunnel data for a pointed tangent ogive with an aspect ratio of 3.5. The separation and reattachment line locations were qualitatively similar to the F-18 wind-tunnel-model oil flows but neither the laminar separation bubble nor the boundary-layer transition on the wind tunnel model were evident in the flight surface flows. The separation and reattachment line locations were in fair agreement with the wind tunnel data for the 3.5 ogive. The elliptical forebody shape of the F-18 caused the primary separation lines to move toward the leeward meridian. Little effect of angle of attack on the separation locations was noted for the range reported.

Fisher, David F.

Visualizing Flow Over Parametric Surfaces Using Line Integral Convolution

Line Integral Convolution (LIC) is a powerful technique for imaging and animating vector fields. We extend the LIC paradigm in three ways: (1) The existing technique is limited to vector fields over a regular Cartesian grid. We extend it to vector fields over parametric surfaces, such as those found in curvilinear grids, used in computational fluid dynamics simulations; (2) Periodic motion filters can be used to animate the flow visualization. When the flow lies on a parametric surface, however, the motion appears misleading. We explain why this problem arises and show how to adjust the LIC algorithm to handle it; (3) We introduce a technique to visualize vector magnitudes as well as vector direction. Cabral and Leedom have suggested a method for variable-speed animation, which is based on varying the frequency of the filter function. We develop a different technique based on kernel phase shifts which we have found to show substantially better results. Our implementation of these algorithms utilizes texture-mapping hardware to run in real time, which allows them to be included in interactive applications.

Forssell, Lisa

Review of flow visualization techniques for unsteady flows

The purpose of this article is to review some of the novel flow visualization techniques that are particularly suited for studying unsteady flows. While many of these techniques were originally developed for steady flow fields, the present paper will emphasize applications to time-dependent flows. The flow visualization methods presented include those that make use of scattered light from small particles or foreign additives as well as those that make use of changes in the index of refraction.

Gad-El-hak, Mohamed

Ozone flow visualization techniques

Flow visualization techniques using ozone for tracing gas flows are proposed whereby ozone is detected through its strong absorption of ultraviolet light, which is easily made visible with fluorescent materials, or through its reaction with nitric oxide to form excited nitrogen dioxide, which in relaxing emits detectable light. It is shown that response speeds in the kHz range are possible with an ultraviolet detection system for initial ozone concentrations of about 1%.

Dickerson, R. R.

Flow Visualization in Evaporating Liquid Drops and Measurement of Dynamic Contact Angles and Spreading Rate

A new hybrid optical system, consisting of reflection-refracted shadowgraphy and top-view photography, is used to visualize flow phenomena and simultaneously measure the spreading and instant dynamic contact angle in a volatile-liquid drop on a nontransparent substrate. Thermocapillary convection in the drop, induced by evaporation, and the drop real-time profile data are synchronously recorded by video recording systems. Experimental results obtained from this unique technique clearly reveal that thermocapillary convection strongly affects the spreading process and the characteristics of dynamic contact angle of the drop. Comprehensive information of a sessile drop, including the local contact angle along the periphery, the instability of the three-phase contact line, and the deformation of the drop shape is obtained and analyzed.

Zhang, Neng-Li

Flow visualization studies of the internal flow characteristics in a simulated mixed flow vectored thrust ASTOVL engine configuration

The characteristics of internal flowfields in a Mixed Flow Vectored Thrust (MFVT) propulsion system for Short Take Off and Vertical Landing (STOVL) fighter aircraft were investigated using flow visualization techniques. A highly parametric 14 percent scale transparent model was used to simulate the MFVT propulsion system. The working medium was water. The mixing between the fan and core flow was studied using flow visualization for a variety of geometrical and flow parameters including three bypass ratio variations. The flow visualization technique involves the use of laser light sheet for illumination and fluorescent dye or air bubbles as tracers. Results indicate the existence of a strong vortex flowfield in the hover mode of operation that is responsible for good mixing between the fan and core flows.

Saripalli, K. R.

B-1 AFT Nacelle Flow Visualization Study

A 2-month program was conducted to perform engineering evaluation and design tasks to prepare for visualization and photography of the airflow along the aft portion of the B-1 nacelles and nozzles during flight test. Several methods of visualizing the flow were investigated and compared with respect to cost, impact of the device on the flow patterns, suitability for use in the flight environment, and operability throughout the flight. Data were based on a literature search and discussions with the test personnel. Tufts were selected as the flow visualization device in preference to several other devices studied. A tuft installation pattern has been prepared for the right-hand aft nacelle area of B-1 air vehicle No.2. Flight research programs to develop flow visualization devices other than tufts for use in future testing are recommended. A design study was conducted to select a suitable motion picture camera, to select the camera location, and to prepare engineering drawings sufficient to permit installation of the camera. Ten locations on the air vehicle were evaluated before the selection of the location in the horizontal stabilizer actuator fairing. The considerations included cost, camera angle, available volume, environmental control, flutter impact, and interference with antennas or other instrumentation.

Celniker, Robert

Flow visualization of secondary flows in three curve ducts

Streak photography flow measurements are made for secondary flows in three 90-deg curved ducts of square cross section and different radii of curvature, at Dean numbers of 15,000-36,000 and radius ratios of 0.5, 2.3, and 3.0. Attention is given to secondary flow patterns for three cross sections in each bend: the inlet zero-deg plane, the midpoint 45-deg plane, and the outlet 90-deg plane. After a rapid transition region, the pressure-driven secondary flow patterns were characterized by flow moving toward the outer curved wall at the axial midplane and returning to the inner wall along the duct walls. The 0.5-radius ratio elbow was found to have the greatest influence on upstream inlet conditions.

Sanz, G. M.

A comparative flow visualization study of thermocapillary flow in drops in liquid-liquid systems

Experiments are performed to visualize thermocapillary flow in drops in an immiscible host liquid. The host liquid used is silicone oil. Drops of three different liquids are used, viz, vegetable oil, water-methanol mixture anad pure methanol. Clear evidence of thermocapillary flow is seen in vegetable oil drops. For a mixture of water and methanol (approximately 50-50 by weight), natural convection is seen to dominate the flow outside the drop. Pure methanol drops exhibit thermocapillary flow, but dissolve in silicone oil. A small amount of water added to pure methanol significantly reduces the dissolution. Flow oscillations occur in this system for both isothermal and non-isothermal conditions.

Balasubramaniam, R.