Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Fixed Base”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Base-Shake

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment plus 3 dB and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Winkel, James P.

Fixed-base and two-body equations of motion for an Annular Momentum Control Device (AMCD)

Fixed base and two body equations of motion for an Annular Momentum Control Device (AMCD) are presented. An AMCD consists of a spinning annular rim which is suspended by noncontacting magnetic bearings and powered by a noncontacting linear electromagnetic motor. The fixed base equations are for a rigid AMCD rim suspended by magnetic bearings attached to a rigid fixed base. The two body equations are for a rigid AMCD rim suspended by magnetic bearings attached to a rigid body spacecraft. The fixed base equations are applicable to any potential ground based AMCD application such as energy storage.

Groom, N. J.

The Effect of Lateral-Directional Control Coupling on Pilot Control of an Airplane as Determined in Flight and in a Fixed-Base Flight Simulator

A flight and fixed-base simulator study was made of the effects of aileron-induced yaw on pilot opinion of aircraft lateral-directional controllability characteristics. A wide range of adverse and favorable aileron-induced yaw was investigated in flight at several levels of Dutch-roll damping. The flight results indicated that the optimum values of aileron- induced yaw differed only slightly from zero for Dutch-roll damping from satisfactory to marginally controllable levels. It was also shown that each range of values of aileron-induced yawing moment considered satisfactory, acceptable, or controllable increased with an increase in the Dutch- roll damping. The increase was most marked for marginally controllable configurations exhibiting favorable aileron-induced yaw. Comparison of fixed-base flight simulator results with flight results showed agreement, indicating that absence of kinesthetic motion cues did not markedly affect the pilots' evaluation of the type of control problem considered in this study. The results of the flight study were recast in terms of several parameters which were considered to have an important effect on pilot opinion of lateral-directional handling qualities, including the effects of control coupling. Results of brief tests with a three-axis side-arm controller indicated that for control coupling problems associated with highly favorable yaw and cross-control techniques, use of the three-axis controller resulted in a deterioration of control relative to results obtained with the conventional center stick and rudder pedals.

Vomaske, Richard F.

Free-Suspension Residual Flexibility Testing of Space Station Pathfinder: Comparison to Fixed-Base Results

Application of the free-suspension residual flexibility modal test method to the International Space Station Pathfinder structure is described. The Pathfinder, a large structure of the general size and weight of Space Station module elements, was also tested in a large fixed-base fixture to simulate Shuttle Orbiter payload constraints. After correlation of the Pathfinder finite element model to residual flexibility test data, the model was coupled to a fixture model, and constrained modes and frequencies were compared to fixed-base test. modes. The residual flexibility model compared very favorably to results of the fixed-base test. This is the first known direct comparison of free-suspension residual flexibility and fixed-base test results for a large structure. The model correlation approach used by the author for residual flexibility data is presented. Frequency response functions (FRF) for the regions of the structure that interface with the environment (a test fixture or another structure) are shown to be the primary tools for model correlation that distinguish or characterize the residual flexibility approach. A number of critical issues related to use of the structure interface FRF for correlating the model are then identified and discussed, including (1) the requirement of prominent stiffness lines, (2) overcoming problems with measurement noise which makes the antiresonances or minima in the functions difficult to identify, and (3) the use of interface stiffness and lumped mass perturbations to bring the analytical responses into agreement with test data. It is shown that good comparison of analytical-to-experimental FRF is the key to obtaining good agreement of the residual flexibility values.

Tinker, Michael L.

Fixed Base Modal Survey of the MPCV Orion European Service Module Structural Test Article

Recently, the MPCV Orion European Service Module Structural Test Article (E-STA) underwent sine vibration testing using the multi-axis shaker system at NASA GRC Plum Brook Station Mechanical Vibration Facility (MVF). An innovative approach using measured constraint shapes at the interface of E-STA to the MVF allowed high-quality fixed base modal parameters of the E-STA to be extracted, which have been used to update the E-STA finite element model (FEM), without the need for a traditional fixed base modal survey. This innovative approach provided considerable program cost and test schedule savings. This paper documents this modal survey, which includes the modal pretest analysis sensor selection, the fixed base methodology using measured constraint shapes as virtual references and measured frequency response functions, and post-survey comparison between measured and analysis fixed base modal parameters.

modal testing

Feasibility Study to Extract Artemis-1 Fixed Base Modes While Mounted on a Dynamically Active Mobile Launch Platform

There are several challenges associated with the scheduled integrated modal test (IMT)of the Space Launch System (SLS) Artemis-1flight vehicle mounted on the mobile launcher (ML). While the goal of the test is to characterize the Artemis-1, the inclusion of the ML as the support stand for the test means that the entire system must be well characterized. A considerable amount of effort and schedule will have to be devoted to understanding both the test stand (the ML) and the Artemis-1 flight vehicle, and there is a risk that the effort may not be completed in time for a successful launch. NASA has requested that alternative methods be investigated to generate test results that can remove the effects of the ML from the test. ATA Engineering, Inc., (ATA)was given a reduced model f theArtemis-1 flight vehicle’s IMT configuration containing the candidate set of accelerometers and interface degrees of freedom (DOF). The model was used to determine how well ATA’s fixed base correction technique is able to estimate fixed base modes from test data collected on the IMT. This paper presents the fixed base correction method results.

modal testing

Space Shuttle payload trunnion interface verification test and correlation with fixed based responses

An interface verification test (IFVT) in the free-free condition was conducted to verify that the constrained modes of a mass simulator had the same frequencies as the Hubble Space Telescope, for which it was designed. Landing tests were performed in which the mass simulator was mounted on its trunnions inside a container onboard an aircraft. Its acceleration response was adequately measured, and the anticipated constrained natural frequencies based on the IFVT were confirmed. The first test updated the model to predict the fixed based modes, and the second verified the test's capacity to characterize the structure. The IFVT is shown to generate information which permits accurate modeling of the constrained structure, without requiring the traditional fixed-based modal test.

Blair, Mark A.

Advanced supersonic transport fixed-base simulator evaluations at landing approach

Equations of motion simulating the landing approach case for the supersonic cruise vehicle were programmed and exercised using a fixed base simulation facility. Unaugmented and augmented system comparisons using this facility are provided. Refinements necessary for system performance improvement are made. The unaugmented longitudinal responses to elevator commands are slow and sluggish, requiring augmentation to increase the speed of the response. In the lateral directional case, the Dutch roll is highly underdamped and requires an augmentation system to increase this damping and provide satisfactory flying qualities. The status of this fixed base study is that the longitudinal equations, updated with recent wind tunnel data, were evaluated on the simulator and the system found to be satisfactory. The lateral axis equations are linearized and are not yet updated to large excursion capability; consequently, only limited, preliminary findings on this system are available. The basic results so far indicate augmentation systems are required to provide a satisfactory longitudinal system, and that additional study and evaluation of the lateral directional case are necessary before a more complete assessment can be made.

Feather, J. B.

Free-free and fixed base modal survey tests of the Space Station Common Module Prototype

This paper describes the testing aspects and the problems encountered during the free-free and fixed base modal surveys completed on the original Space Station Common Module Prototype (CMP). The CMP is a 40-ft long by 14.5-ft diameter 'waffle-grid' cylinder built by the Boeing Company and housed at the Marshall Space Flight Center (MSFC) near Huntsville, AL. The CMP modal survey tests were conducted at MSFC by the Dynamics Test Branch. The free-free modal survey tests (June '90 to Sept. '90) included interface verification tests (IFVT), often referred to as impedance measurements, mass-additive testing and linearity studies. The fixed base modal survey tests (Feb. '91 to April '91), including linearity studies, were conducted in a fixture designed to constrain the CMP in 7 total degrees-of-freedom at five trunnion interfaces (two primary, two secondary, and the keel). The fixture also incorporated an airbag off-load system designed to alleviate the non-linear effects of friction in the primary and secondary trunnion interfaces. Numerous test configurations were performed with the objective of providing a modal data base for evaluating the various testing methodologies to verify dynamic finite element models used for input to coupled load analysis.

Driskill, T. C.

Evaluation of g seat augmentation of fixed-base/moving base simulation for transport landings under two visually imposed runway width conditions

Vertical-motion cues supplied by a g-seat to augment platform motion cues in the other five degrees of freedom were evaluated in terms of their effect on objective performance measures obtained during simulated transport landings under visual conditions. In addition to evaluating the effects of the vertical cueing, runway width and magnification effects were investigated. The g-seat was evaluated during fixed base and moving-base operations. Although performance with the g-seat only improved slightly over that with fixed-base operation, combined g-seat platform operation showed no improvement over improvement over platform-only operation. When one runway width at one magnification factor was compared with another width at a different factor, the visual results indicated that the runway width probably had no effect on pilot-vehicle performance. The new performance differences that were detected may be more readily attributed to the extant (existing throughout) increase in vertical velocity induced by the magnification factor used to change the runway width, rather than to the width itself.

Parrish, R. V.

Empirical comparison of a fixed-base and a moving-base simulation of a helicopter engaged in visually conducted slalom runs

Combined visual, motion, and aural cues for a helicopter engaged in visually conducted slalom runs at low altitude were studied. The evaluation of the visual and aural cues was subjective, whereas the motion cues were evaluated both subjectively and objectively. Subjective and objective results coincided in the area of control activity. Generally, less control activity is present under motion conditions than under fixed-base conditions, a fact attributed subjectively to the feeling of realistic limitations of a machine (helicopter) given by the addition of motion cues. The objective data also revealed that the slalom runs were conducted at significantly higher altitudes under motion conditions than under fixed-base conditions.

Parrish, R. V.

Modal Testing of a Flexible Wing on a Dynamically Active Test Fixture Using the Fixed Base Correction Method

In modal testing and finite element model correlation, analysts desire modal results using free-free or rigid boundary conditions to ease comparisons of test versus analytical data. It is often expensive both in cost and schedule to build and test with boundary conditions that replicate the free-free or rigid boundaries. Static test fixtures for load testing are often large, heavy, and unyielding, and not provide adequate boundaries for modal tests because they are dynamically too flexible and often contain natural frequencies within the test article frequency range of interest. The dynamic coupling between the test article and test fixture complicates the model updating process because significant effort needs to be spent on modeling the test fixture and boundary conditions in addition to the test article. If the modal results could be corrected for fixture coupling, then setups used for other structural testing could be adequate for modal testing and would allow significant schedule and cost savings by eliminating a unique setup for only modal testing. To simplify future modal tests, this report describes a Fixed Base Correction method that was investigated during modal testing of a full-scale, half-span, flexible wing cantilevered from a static test fixture. The results of this Fixed Base Correction approach look very promising. The method aided in producing similar wing modal characteristics for two different physical boundary configurations of a dynamically active test fixture.

Natalie D Spivey

Modal Testing of a Flexible Wing on a Dynamically Active Test Fixture Using Fixed Base Correction Method - IFASD 2019

In modal testing and finite element model correlation, analysts desire modal results using free-free or rigid boundary conditions to ease comparisons of test versus analytical data. It is often expensive both in cost and schedule to build and test with boundary conditions that replicate the free-free or rigid boundaries. Static test fixtures for load testing are often large, heavy, and unyielding, but do not provide adequate boundaries for modal tests because they are dynamically too flexible and often contain natural frequencies within the test article frequency range of interest. The dynamic coupling between the test article and test fixture complicates the model updating process because significant effort needs to be spent on modeling the test fixture and boundary conditions in addition to the test article. If the modal results could be corrected for fixture coupling, then setups used for other structural testing could be adequate for modal testing and would allow significant schedule and cost savings by eliminating a unique setup for only modal testing. To simplify future modal tests, this paper reports on a fixed base correction method that was investigated during modal testing of a full-scale, half-span, flexible wing cantilevered from a static test fixture. The results of this fixed base correction approach look very promising. The method aided in producing similar wing modal characteristics for two different physical boundary configurations of a dynamically active test fixture.

modal testing

Fuel Cell Power Plant Initiative: Preliminary Design of a Fixed-Base LFP/SOFC Power System - Volume 2

This report documents the preliminary design for a military fixed-base power system of 3 MWe nominal capacity using Westinghouse's tubular Solid Oxide Fuel Cell [SOFC] and Haldor Topsoe's logistic fuels processor [LFP]. The LFP provides to the fuel cell a methane rich sulfur free fuel stream derived from either DF-2 diesel fuel, or JP-8 turbine fuel. Fuel cells are electrochemical devices that directly convert the chemical energy contained in fuels such as hydrogen, natural gas, or coal gas into electricity at high efficiency with no intermediate heat engine or dynamo. The SOFC is distinguished from other fuel cell types by its solid state ceramic structure and its high operating temperature, nominally 1000'C. The SOFC pioneered by Westinghouse has a tubular geometry closed at one end. A power generation stack is formed by aggregating many cells in an ordered array. The Westinghouse stack design is distinguished from other fuel cell stacks by the complete absence of high integrity seals between cell elements, cells, and between stack and manifolds. Further, the reformer for natural gas [predominantly methane] and the stack are thermally and hydraulically integrated with no requirement for process water. The technical viability of combining the tubular SOFC and a logistic fuels processor was demonstrated at 27 kWe scale in a test program sponsored by the Advanced Research Projects Agency [ARPA) and carried out at the Southern California Edison's [SCE] Highgrove generating station near San Bernardino, California in 1994/95. The LFP was a breadboard design supplied by Haldor Topsoe, Inc. under subcontract to Westinghouse. The test program was completely successful. The LFP fueled the SOFC for 766 hours on JP-8 and 1555 hours of DF-2. In addition, the fuel cell operated for 3261 hours on pipeline natural gas. Over the 5582 hours of operation, the SOFC generated 118 MVVH of electricity with no perceptible degradation in performance. The LFP processed military specification JP-8 and DF-2 removing the sulfur and reforming these liquid fuels to a methane rich gaseous fuel. Results of this program are documented in a companion report titled 'Final Report-Solid Oxide Fuel Cell/ Logistic Fuels Processor 27 kWe Power System'.

Veyo, S.E.