SEARCH · Engineering Papers
Results for “Firing Room”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Simulation of Deuterium Oxidation in a Room with a Fire
A series of experiments where deuterium was released in trace amounts into a room with a fire were performed at Sandia National Laboratories. This report describes the corresponding effort to model the test series using SIERRA/FUEGO. The objective of this modeling effort was to produce a simulation test matrix that can be utilized to help interpret the corresponding experiments and be used to assess the credibility of using the SIERRA/FUEGO simulations as a surrogate for real tritium reaction data for mock fire and release studies. The simulations assessed multiple configurations of fire size and location and overall found that there was low conversion of deuterium to oxidized deuterium. There are some notable differences between the simulation predictions and the experimental results, such as the simulations generally predicting higher amounts of deuterium conversion compared to the experiment. A strategy to address modeling uncertainties and unknowns is also given in this report.
Deuterium Releases in a Room with a Fire as a Tritium Surrogate
This is for the tritium focus group meeting at PNNL in a few weeks. I'll also share this with the TRIDENT venture team on 10/16.
10 CFR 830 Major Modification Determination for the Advanced Test Reactor Remote Monitoring and Management Capability
The Advanced Test Reactor (ATR; TRA-670), which is located in the ATR Complex at Idaho National Laboratory, was constructed in the 1960s for the purpose of irradiating reactor fuels and materials. Other irradiation services, such as radioisotope production, are also performed at ATR. While ATR is safely fulfilling current mission requirements, assessments are continuing. These assessments intend to identify areas to provide defense–in-depth and improve safety for ATR. One of the assessments performed by an independent group of nuclear industry experts recommended that a remote accident management capability be provided. The report stated that: “contemporary practice in commercial power reactors is to provide a remote shutdown station or stations to allow shutdown of the reactor and management of long-term cooling of the reactor (i.e., management of reactivity, inventory, and cooling) should the main control room be disabled (e.g., due to a fire in the control room or affecting the control room).” This project will install remote reactor monitoring and management capabilities for ATR. Remote capabilities will allow for post scram reactor management and monitoring in the event the main Reactor Control Room (RCR) must be evacuated.
System Requirements for the Implementation of a Fused Silica Debris Shield
The National Ignition Facility (NIF) is the world’s largest and most energetic laser. It consists of 192 individual laser beams that, when first fired from the master oscillator room, are no more energetic than a typical laser pointer. After the initial firing, the lasers are sent through a preamplifier where the energy is increased by a factor of 10 billion. The laser light is amplified even further in the NIF laser bays by “stretching”each individual laser to a cross sectional area of approximately one square foot and passing them through the NIF power amplifiers, then multiple times through the NIF main amplifiers inside the NIF Laser bays. The laser beams make one final pass through the through the power amplifiers before they are reflected out of the laser bays.
Characterizing post-fire delayed tree mortality with remote sensing: sizing up the elephant in the room
Abstract Background Despite recent advances in understanding the drivers of tree-level delayed mortality, we lack a method for mapping delayed mortality at landscape and regional scales. Consequently, the extent, magnitude, and effects of delayed mortality on post-fire landscape patterns of burn severity are unknown. We introduce a remote sensing approach for mapping delayed mortality based on post-fire decline in the normalized burn ratio (NBR). NBR decline is defined as the change in NBR between the first post-fire measurement and the minimum NBR value up to 5 years post-fire for each pixel. We validate the method with high-resolution aerial photography from six wildfires in California, Oregon, and Washington, USA, and then compare the extent, magnitude, and effects of delayed mortality on landscape patterns of burn severity among fires and forest types. Results NBR decline was significantly correlated with post-fire canopy mortality (r 2 = 0.50) and predicted the presence of delayed mortality with 83% accuracy based on a threshold of 105 NBR decline. Plots with NBR decline greater than 105 were 23 times more likely to experience delayed mortality than those below the threshold (p < 0.001). Delayed mortality occurred across 6–38% of fire perimeters not affected by stand-replacing fire, generally affecting more areas in cold (22–41%) and wet (30%) forest types than in dry (1.7–19%) types. The total area initially mapped as unburned/very low-severity declined an average of 38.1% and generally persisted in smaller, more fragmented patches when considering delayed mortality. The total area initially mapped as high-severity increased an average of 16.2% and shifted towards larger, more contiguous patches. Conclusions Differences between 1- and 5-year post-fire burn severity maps depict dynamic post-fire mosaics resulting from delayed mortality, with variability among fires reflecting a range of potential drivers. We demonstrate that tree-level delayed mortality scales up to alter higher-level landscape patterns of burn severity with important implications for forest resilience and a range of fire-driven ecological outcomes. Our method can complement existing tree-level studies on drivers of delayed mortality, refine mapping of fire refugia, inform estimates of habitat and carbon losses, and provide a more comprehensive assessment of landscape and regional scale fire effects and trends.
Industry Level Integrated Fire Modeling Using Fire Risk Investigation in 3D (FRI3D)
The software Fire Risk Investigation in 3D (FRI3D) has been developed over the last 2 years to integrate 3D spatial modeling with existing fire probabilistic risk assessment (PRA) models and fire simulation codes. The goal of this research and development is to automate many of the fire analysis manual tasks to reduce industry efforts in the initial fire modeling and operational costs for the model maintenance and evaluations required during normal plant operations. The tasks for Fiscal Year (FY) 2021 include first testing the FRI3D modeling capabilities by importing an industry fire model into FRI3D and making a 3D model of a complex/high-risk significant area. (For this work, the switchgear room was chosen.) Then, the second task of FY 2021 is to develop a dynamic fire PRA process that can help optimize traditional fire PRA models. The switchgear room model will be used for the dynamic fire PRA work. This report describes the work and insights learned when using FRI3D software to model both a Nuclear Regulatory Report (NUREG) example models and a full industry switchgear room.
Metal inks
Self-reducing metal inks and systems and methods for producing and using the same are disclosed. In an exemplary embodiment, a method may comprise selecting metal-organic (MO) precursor, selecting a reducing agent, and dissolving the MO precursor and the reducing agent in an organic solvent to produce a metal ink that remains in a liquid phase at room temperature. Metal inks, including self-reducing and fire-through metal inks, are also disclosed, as are various applications of the metal inks.
LANSCE Module 1 Capacitor Room Failure [Slides]
At ~3:30 am on Sunday, high-voltage line in capacitor room overheated to the extent that the poly insulating material caught fire and dripped melted insulation onto equipment below. LAFD responded and, per pre-incident planning, waited for AOT personnel to respond to the area. AOT personnel, safed equipment and waited with LAFD for fire to “burn out”. Using an IWD, AOT personnel safely re-entered the area after conducting hazards analysis and engaging SMEs, re: controls for combustion products and COVID-19 hazards. Recovery action took several days with a focus on getting it right. Beam re-start decisions were made with impacted organizations and considering AOTRFE personnel.
Glovebox Fires Phase 1: Simulations of Open Burner Experiments
Understanding the duration of a fire required to breach a glovebox via glove ports and/or windows within a facility is important in developing mitigation strategies for safety. To facilitate this understanding, both simulation and experiments are utilized. The approach is to first validate the Computation Fluid Dynamics (CFD) code, Fire Dynamics Simulator (FDS), with experimental data collected by New Mexico Tech (NMT) and then perform simulations of full-scale rooms containing gloveboxes to assess numerous scenarios which would otherwise be cost-prohibitive experimentally. This report provides comparison to first-phase experiments involving a fire without a glovebox. A subsequent report will provide comparison to experiments involving a glovebox. The results indicate good agreement with FDS tending to over predict the pre-mixed and diffusion-mode tests by 6% and 10%, respectively.
Compatibility of Steels in Supercritical CO2 at 450°-650°C
Supercritical CO2 (sCO2) power cycles, particularly direct-fired cycles, have the possibility of revolutionizing clean fossil energy. However, in the lower temperature sections of the cycle, lower cost steels are needed in order to lower the cost of the sCO2 technology. Representative 9 and 12%Cr steels and conventional and advanced austenitic steels are being evaluated at 450-650°C using mass change, bulk carbon (C) content and room temperature tensile properties to determine the maximum use temperatures for both direct- and indirect-fired sCO2 cycles. After 1000 h exposures in research grade (RG) sCO2 at 300 bar and RG sCO2 with 1% O2 and 0.1% H2O additions, the results suggest that increasing the Cr content from 9 to 12% yielded no signficant benefit under these conditions but the higher Cr and Ni contents in S31025 provided better compatibility in RG sCO2 at 650°C but limited benefit at 550°C with impurities. For S31609, the formation of Fe-rich oxide after exposure to RG sCO2 at 650°C resulted in both an increase in the bulk C content and a large drop in room temperature ductility. The evidence suggests thin, protective oxides prevented C ingress in these conditions.
Test Report: Glovebox Test Fire for Evaluation of Effects on Containers and Windows
This test report describes a designed Glovebox (GB) fire to identify target environmental conditions that GB containers and windows are subject to such fires. The fire was designed by representatives from the Los Alamos National Laboratory (LANL) to replicate a realistic worst-case fire scenario at LANL. Key results of these experiments include: • The GB fire was active for more than 30 minutes. • Thermocouples were placed at multiple points in the GB were measured, including one on top of the container. Temperatures at varied widely as a function of location during the fires, as might be expected and as a function of proximity to fire, elevation in the GB, and in relation airflow present during the test, which constantly introduces room-temperature air into the GB. The maximum temperature recorded by a thermocouple was slightly less than 500°F at the elevation of the highest gloveports and near, but not in contact with the GB wall. • A thermographic camera imaged the region of the GB container during the fire. These data report container temperatures of up to approximately 900°F (482°C) over a period of several minutes. • Four kilograms of lead shot were held in the container. The majority of the shot melted during the course of the fire (lead melting point: 621°F/327°C). • Multiple windows fractured during the test. In some cases, the polymer interlayer of the laminated GB window glass appears to have sustained damage due to thermal breakdown of the polymer, though the interlayer of the laminated GB window glass appears to have remained intact in all cases. • The one window with an attached thermocouple was less affected by the fire. The attached thermocouple measured up to approximately 150°F. • Other thermocouples along (but not in contact with) the GB wall and closer to the fire (and cracked windows) reported up to approximately 200°C (392° F). These finding suggest that subjecting containers to 500°C for 45 minutes is bounding and representative for fires of this type. It should also be noted that 500°C (932°F) has been previously used as a test criterion for related work. Similarly, 200°C may be a reasonable target temperature for GB windows subjected to fires of this type.
Analysis of the Enameled AISI 316LVM Stainless Steel
In this work, four different enamels were coated on AISI 316LVM stainless steel and the corrosion resistance of these samples was tested in 5 wt.% NaCl solution at room temperature. The preparation procedure of the enamels was optimized in terms of firing temperature, time and composition. First the thermal expansion was measured using dilatometry followed by electrochemical analysis using chronopotentiometry, electrochemical impedance spectroscopy and cyclic polarization. The topography of the most resistant sample was obtained by 3D-profilometry. All samples coated with enamel showed significantly higher corrosion and dilatation resistance compared with the uncoated stainless steel material.
Mechanical behavior of carbonated MgO-based Engineered Cementitious Composite (ECC) after high temperatures exposure
Carbonated MgO-based Engineered Cementitious Composite (ECC) has ultrahigh tensile ductility and tight crack width control behavior. However, the expectation of improved fire-resistant has not been confirmed. This study explored the alterations to mechanical and microstructure characteristics of this material after exposure to temperatures up to 500 °C. Material mass loss, compressive strength, tensile strength, strain capacity, and matrix fracture toughness were measured. Scanning electron microscopy, mercury intrusion porosimetry, thermogravimetric analysis, and X-ray diffraction were used to probe the degradation of the cement matrix and fibers. The effect of elevated temperature on carbonated MgO-based ECC was further assessed via examination of the micromechanical behavior of the fiber-matrix. The objective of this research was to assess the performance of carbonated MgO-based ECC exposed to fire hazards. The tensile ductility of carbonated MgO-based ECC was found to be enhanced when exposed to ~100 °C as compared with those at room temperature ~20 °C. Further increase in exposure temperature, however, posed a negative impact on the composite compressive strength, ultimate tensile strength, and ability to control crack width. Here the results provide a useful database for further investigations into carbonated MgO-based ECC for fire safety enhancement.
Green co-solvent-assisted one-pot synthesis of high-performance flexible lignin polyurethane foam
Although lignin is a promising candidate as a source of polyol for producing eco-friendly polyurethane foam (PUF), its direct application has limitations, primarily stemming from the brittleness of the resulting products and poor processibility at high lignin loadings. To address these technical challenges, we introduced an effective co-solvent for the lignin-based polyurethane foams (LPUFs) with up to 80wt% of lignin substitution for petroleum polyols. As a green co-solvent that involves carbon dioxide fixation during its production, propylene carbonate (PC), was blended with lignin and improved the distribution of lignin by decreasing the viscosity, providing a room-temperature reaction. The LPUFs demonstrated a comparable thermal insulation performance (R-values greater than 5 in -1 ) with commercially available PUF with a uniform size of closed-cell structure induced by the reduced viscosity of lignin-based polyol. LPUFs also showed enhanced fire retardancy and moisture resistance compared to the control PUFs, benefiting from lignin’s intrinsic fire-resistant and hydrophobic properties. To mitigate the brittleness issue at high lignin loadings, flexible polyethylene glycols (PEGs) with a high molecular weight (i.e., PEG-1000) were dissolved in PC at room temperature to further improve the mechanical strength of LPUFs. The compressive strength of LPUFs with 80 wt% lignin substitution content was remarkably improved to 226 kPa by the employment of co-solvent and PEG-1000 compared to the control PUF (<140 kPa). Moreover, the flexibility of the LPUFs was successfully controlled by simply adjusting the PEG-400/PEG-1000 ratio. In conclusion, the results of this study provide valuable insights for accelerating and broadening the utilization of lignin in sustainable materials and manufacturing areas.
Effect of thickness on degradation of austenitic 347H steel by direct-fired supercritical CO 2 power cycle environment
Austenitic 347H steel of two thicknesses (2.54 and 0.6 mm) was exposed to a simulated direct-fired supercritical CO 2 (sCO 2 ) power cycle environment at 650°C and 1 atm for 1000 h then tensile stressed at room temperature to study the deformation behavior. The thicker 347H formed a protective chromia scale over most of the surface, which minimized carburization of the underlying steel and resulted in no change in mechanical performance. In stark contrast, the thinner 347H formed non-protective Fe-rich oxides over the entire surface, resulting in extensive carburization of the underlying steel. Finally, this led to increased strength but significantly reduced ductility, resulting in partially brittle failure
Perspectives on Artificial Intelligence for Predictions in Ecohydrology
Abstract In November 2021, the Artificial Intelligence for Earth System Predictability (AI4ESP) workshop was held, which involved hundreds of researchers from dozens of institutions. There were 17 sessions held at the workshop, including one on ecohydrology. The ecohydrology session included various breakout rooms that addressed specific topics, including 1) soils and belowground areas; 2) watersheds; 3) hydrology; 4) ecophysiology and plant hydraulics; 5) ecology; 6) extremes, disturbance and fire, and land-use and land-cover change; and 7) uncertainty quantification methods and techniques. In this paper, we investigate and report on the potential application of artificial intelligence and machine learning in ecohydrology, highlight outcomes of the ecohydrology session at the AI4ESP workshop, and provide visionary perspectives for future research in this area.
Volume changes upon heating of aerosol particles from biomass burning using transmission electron microscopy
The responses of aerosol particles to heating are important for measurements of their chemical, physical, and optical properties, classification, and determination of origin. However, the thermal behavior of organic aerosol particles is largely unknown. We provide a method to analyze such thermal behavior through heating from room temperature to >600°C by using a heating holder within a transmission electron microscope (TEM). Here we describe in-situ shape and size changes and variations in the compositions of individual particles before and after heating. We use ambient samples from wildland and agricultural biomass fires in North America collected during the 2013 Biomass Burn Observation Project (BBOP). The results indicate that individual tar balls (TB; spherical organic material) from biomass burning retained, on average, up to 30% of their volume when heated to 600°C. Chemical analysis reveals that K and Na remain in the residues, whereas S and O were lost. In contrast to bulk sample measurements of carbonaceous particles using thermal/optical carbon analyzers, our single-particle results imply that many individual organic particles consist of multiple types of organic matter having different thermal stabilities. Beyond TBs, our results suggest that because of their thermal stability some organic particles may not be detectable by using aerosol mass spectrometry or thermal/optical carbon analyzers. This result can lead to an underestimate of the abundance of TBs and other organic particles, and therefore biomass burning may have more influence than currently recognized in regional and global climate models.