Fire protection for launch facilities using machine vision fire detection

Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.

Schwartz, Douglas B.↗

A Combined Water-Bromotrifluoromethane Crash-Fire Protection System for a T-56 Turbopropeller Engine

A crash-fire protection system is described which will suppress the ignition of crash-spilled fuel that may be ingested by a T-56 turbo-propeller engine. This system includes means for rapidly extinguishing the combustor flame, means for cooling and inerting with water the hot engine parts likely to ignite engine ingested fuel, and means for blanketing with bromotrifluoromethane massive metal parts that may reheat after the engine stops rotating. Combustion-chamber flames were rapidly extinguished at the engine fuel nozzles by a fuel shutoff and drain valve. Hot engine parts were inerted and cooled by 42 pounds of water discharged at seven engine stations. Massive metal parts that could reheat were inerted with 10 pounds of bromotrifluoromethane discharged at two engine stations. Performance trials of the crash-fire protection system were conducted by bringing the engine up to takeoff temperature, actuating the crash-fire protection system, and then spraying fuel into the engine to simulate crash-ingested fuel. No fires occurred during these trials, although fuel was sprayed into the engine from 0.3 second to 15 minutes after actuating the crash-fire protection system.

Campbell, John A.↗

Crew Exploration Vehicle Environmental Control and Life Support Fire Protection Approach

As part of preparing for the Crew Exploration Vehicle (CEV), the National Aeronautics and Space Administration (NASA) worked on developing the requirements to manage the fire risk. The new CEV poses unique challenges to current fire protection systems. The size and configuration of the vehicle resembles the Apollo capsule instead of the current Space Shuttle or the International Space Station. The smaller free air volume and fully cold plated avionic bays of the CEV requires a different approach in fire protection than the ones currently utilized. The fire protection approach discussed in this paper incorporates historical lessons learned and fire detection and suppression system design philosophy spanning from Apollo to the International Space Station. Working with NASA fire and materials experts, this approach outlines the best requirements for both the closed out area of the vehicle, such as the avionics bay, and the crew cabin area to address the unique challenges due to the size and configuration of the CEV.

Lewis, John F.↗

NASA Fire Protection Coordinators' Conference

Fire prevention activities at NASA's Stennis Space Center are reviewed in this viewgraph presentation. The Fire Prevention Office of the Fire Department at NASA Stennis conducts inspections and issues small appliance permits, while the Operations Section responds to emergencies.

Clark, Theodore↗

NASA Fire Protection

This viewgraph presentation provides information on fire protection operations and administration at Stennis Space Center (SSC). The presentation also lists innovative practices and recent improvements.

Clark, Theodore↗

Crash-Fire Protection System for T-56 Turbopropeller Engine Using Water as Cooling and Inerting Agent

A crash-fire protection system to suppress the ignition of crash-spilled fuel that may be ingested by a T-56 turbopropeller engine is described. This system includes means for rapidly extinguishing the combustor flame and means for cooling and inerting with water the hot engine parts likely to ignite engine-ingested fuel. Combustion-chamber flames were extinguished in 0.07 second at the engine fuel manifold. Hot engine parts were inerted and cooled by 52 pounds of water discharged at ten engine stations. Performance trials of the crash-fire prevention system were conducted by bringing the engine up to takeoff temperature, stopping the normal fuel flow to the engine, starting the water discharge, and then spraying fuel into the engine to simulate crash-ingested fuel. No fires occurred during these trials, although fuel was sprayed into the engine from 0.3 second to 15 minutes after actuating the crash-fire protection system.

Busch, Arthur M.↗

An effective and practical fire-protection system

A high-performance sandwich-type fire protection system comprising a steel outer sheath and insulation combined in various configurations is described. An inherent advantage of the sheath system over coatings is that it eliminates problems of weatherability, materials strength, adhesion, and chemical attack. An experimental comparison between the protection performance of state-of-the-art coatings and the sheath system is presented, with emphasis on the protection of certain types of steel tanks for fuel storage and transport. Sheath systems are thought to be more expensive than coatings in initial implementation, although they are less expensive per year for sufficiently long applications.

Mansfield, J. A.↗

A feasibility study: California Department of Forestry and Fire Protection utilization of infrared technologies for wildland fire suppression and management

NASA's JPL has completed a feasibility study using infrared technologies for wildland fire suppression and management. The study surveyed user needs, examined available technologies, matched the user needs with technologies, and defined an integrated infrared wildland fire mapping concept system configuration. System component trade-offs were presented for evaluation in the concept system configuration. The economic benefits of using infrared technologies in fire suppression and management were examined. Follow-on concept system configuration development and implementation were proposed.

Nichols, J. D.↗

Fire Protection Jacket

NERAC, Inc., Tolland, CT, aided Paul Monroe Engineering, Orange, CA, in the development of their PC1200 Series Fire Protection Jacket that protects the oil conduit system on an offshore drilling platform from the intense hydrocarbon fires that cause buckling and could cause structural failure of the platform. The flame-proof jacketing, which can withstand temperatures of 2000 degrees Fahrenheit for four hours or more, was developed from a combination of ceramic cloth (similar to the ceramic in Space Shuttle tiles), and laminates used in space suits.

Source record↗

Fire Protection Materials

Avco has drawn upon its heat shield experience to develop a number of widely-accepted commercial fire protection materials. Originating from NASA's space shuttle thermal protection system, one such material is Chartek 59 fireproofing, an intumescent epoxy coating specifically designed for outdoor use by industrial facilities dealing with highly flammable products such as oil refineries and chemical plants. The coating is applied usually by spray gun to exterior structural steel conduits, pipes and valves, offshore platforms and liquefied petroleum gas tanks. Fireproofing provides two types of protection: ablation or dissipation of heat by burn-off and "intumescence" or swelling; the coating swells to about five times its original size, forming a protective blanket of char which retards transfer of heat to the metal structure preventing loss of structural strength and possible collapse which would compound the fire fighting problem.

Source record↗

Study of aircraft crashworthiness for fire protection

Impact-survivable postcrash fire accidents were surveyed. The data base developed includes foreign and domestic accidents involving airlines and jet aircraft. The emphasis was placed on domestic accidents, airlines, and jet aircraft due principally to availability of information. Only transport category aircraft in commercial service designed under FAR Part 25 were considered. A matrix was prepared to show the relationships between the accident characteristics and the fire fatalities. Typical postcrash fire scenaries were identified. Safety concepts were developed for three engineering categories: cabin interiors - cabin subsystems; power plant - engines and fuel systems; and structural mechanics - primary and secondary structures. The parameters identified for concept evaluation are cost, effectiveness, and societal concerns. Three concepts were selected for design definition and cost and effectiveness analysis: improved fire-resistant seat materials; anti-misting kerosene; and additional cabin emergency exits.

Cominsky, A.↗

Polyimide foams provide thermal insulation and fire protection

Chemical reactions to produce polyimide foams for application as thermal insulation and fire prevention materials are discussed. Thermal and physical properties of the polyimides are described. Methods for improving basic formulations to produce desired qualitites are included.

Rosser, R. W.↗

F-200(TM): The new solution for fire protection

For more than two decades, halon 1301 has been protecting personnel and valuable aircraft and aerospace equipment from the hazards of fire. Only halon 1301 offered the advantages of being clean, odorless, colorless, electrically non-conductive and safe for occupied areas. However, concerns about the depletion of stratospheric ozone and the resulting Montreal Protocol mandated the production phase-out of halon 1301 on December 31, 1993. Prior to this phase-out, Great Lakes Chemical Corporation, the world's leading manufacturer of halon, directed substantial research efforts toward the rapid development of a safe, clean, and effective halon replacement. Some of the criteria for the development of a clean agent included: that it be an effective fire extinguisher; that it be safe for personnel; that it be safe for the environment; that it be safe for valuable assets; that it be cost effective; and that it be able to withstand the rigors of independent approvals. As the result of this research, Great Lakes developed FM-200(TM) is 1, 1, 1, 2, 3, 3, 3-hepta-fluoropropane. This paper discusses the physical properties of FM-200(TM) and its efficiency as an extinguishant.

Thornton, Alfred J.↗

An intumescent coating for improved fuel fire protection of heat sensitive articles.

Intumescent coating compositions have been prepared using the ammonium salt of 4-nitroaniline-2-sulfonic acid and a copolymer of polysulfide-epoxy resin as the binder, into which have been dispersed various fillers. The fillers used in the study were low density microballoons for density control and fibers for controlled intumescence on contoured substrates. The filler effect on the thermal-physical efficiency of coatings has been measured. The coating utilizing short length silica fibers has been shown to have superior mechanical, environmental, and thermal properties. The coating applied to the exterior of loaded weapons has increased the time-to-detonation from three minutes for the unprotected weapon to 10-13 minutes.

Sawko, P. M.↗

Polyimide foam for the thermal insulation and fire protection

The preparation of chemically resistant and flame retardant foams from polyfunctional aromatic carboxylic acid derivatives and organic polyisocyanates is outlined. It was found that polyimide foams of reproducible density above 1 lb./ft. and below 6 lbs./cu ft. can be obtained by employing in the reaction of least 2% by weight of siloxane-glycol copolymer as a surfactant which acts as a specific density control agent. Polyimide foams into which reinforcing fibers such as silicon dioxide and carbon fibers may be incorporated were also produced.

Rosser, R. W.↗