Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Filter Absorption Coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

TRACER-MAP_2022_absorption_coefficient

Absorption coefficient for PM2.5 measured by the Tri-color Absorption Photometer averaged every 2 minutes for July-August 2022. The location of the measurement is indicated by latitude and longitude coordinates; TRACER-MAP included time at the AMF site in La Porte and additional sites around Houston. Three wavelengths are reported: 365, 520 and 640 nm. The AAE is also reported using the three wavelengths. The data is reported as 2 minute averages.

54 ENVIRONMENTAL SCIENCES↗

Correcting for filter-based aerosol light absorption biases at the Atmospheric Radiation Measurement program's Southern Great Plains site using photoacoustic measurements and machine learning

Abstract. Measurement of light absorption of solar radiation by aerosols is vital for assessing direct aerosol radiative forcing, which affects local and global climate. Low-cost and easy-to-operate filter-based instruments, such as the Particle Soot Absorption Photometer (PSAP), that collect aerosols on a filter and measure light attenuation through the filter are widely used to infer aerosol light absorption. However, filter-based absorption measurements are subject to artifacts that are difficult to quantify. These artifacts are associated with the presence of the filter medium and the complex interactions between the filter fibers and accumulated aerosols. Various correction algorithms have been introduced to correct for the filter-based absorption coefficient measurements toward predicting the particle-phase absorption coefficient (Babs). However, the inability of these algorithms to incorporate into their formulations the complex matrix of influencing parameters such as particle asymmetry parameter, particle size, and particle penetration depth results in prediction of particle-phase absorption coefficients with relatively low accuracy. The analytical forms of corrections also suffer from a lack of universal applicability: different corrections are required for rural and urban sites across the world. In this study, we analyzed and compared 3 months of high-time-resolution ambient aerosol absorption data collected synchronously using a three-wavelength photoacoustic absorption spectrometer (PASS) and PSAP. Both instruments were operated on the same sampling inlet at the Department of Energy's Atmospheric Radiation Measurement program's Southern Great Plains (SGP) user facility in Oklahoma. We implemented the two most commonly used analytical correction algorithms, namely, Virkkula (2010) and the average of Virkkula (2010) and Ogren (2010)–Bond et al. (1999) as well as a random forest regression (RFR) machine learning algorithm to predict Babs values from the PSAP's filter-based measurements. The predicted Babs was compared against the reference Babs measured by the PASS. The RFR algorithm performed the best by yielding the lowest root mean square error of prediction. The algorithm was trained using input datasets from the PSAP (transmission and uncorrected absorption coefficient), a co-located nephelometer (scattering coefficients), and the Aerosol Chemical Speciation Monitor (mass concentration of non-refractory aerosol particles). A revised form of the Virkkula (2010) algorithm suitable for the SGP site has been proposed; however, its performance yields approximately 2-fold errors when compared to the RFR algorithm. To generalize the accuracy and applicability of our proposed RFR algorithm, we trained and tested it on a dataset of laboratory measurements of combustion aerosols. Input variables to the algorithm included the aerosol number size distribution from the Scanning Mobility Particle Sizer, absorption coefficients from the filter-based Tricolor Absorption Photometer, and scattering coefficients from a multiwavelength nephelometer. The RFR algorithm predicted Babs values within 5 % of the reference Babs measured by the multiwavelength PASS during the laboratory experiments. Thus, we show that machine learning approaches offer a promising path to correct for biases in long-term filter-based absorption datasets and accurately quantify their variability and trends needed for robust radiative forcing determination.

54 ENVIRONMENTAL SCIENCES↗

aospsap3w1s.b1

The aospsap3w1m process reads in data from the aospsap3w.b1 datastream and applies a dilution correction to the aerosol sample flow rate, and a filter loading correction to the absorption coefficients. The filter loading is corrected by multiplying by the Weiss transfer function f_w = 1/1.031 * 1/1.22 * (1/(1.0796 Tr + 0.71)) = 1 / (1.3579 Tr + 0.8931) where Tr is the transmittance for a given wavelength. This form incorporates the initial PSAP transfer function with modifications in Bond 1999 and subsequently in Ogren 2010. The one second (1s) data stream is only created for BNL psap3w instruments where the 1 second samples are available. The one minute (1m) data streams contain the averages of the one second data.

54 ENVIRONMENTAL SCIENCES↗

aospsap3w1m.b1

The aospsap3w1m process reads in data from the aospsap3w.b1 datastream and applies a dilution correction to the aerosol sample flow rate, and a filter loading correction to the absorption coefficients. The filter loading is corrected by multiplying by the Weiss transfer function f_w = 1/1.031 * 1/1.22 * (1/(1.0796 Tr + 0.71)) = 1 / (1.3579 Tr + 0.8931) where Tr is the transmittance for a given wavelength. This form incorporates the initial PSAP transfer function with modifications in Bond 1999 and subsequently in Ogren 2010. The one second (1s) data stream is only created for BNL psap3w instruments where the 1 second samples are available. The one minute (1m) data streams contain the averages of the one second data.

54 ENVIRONMENTAL SCIENCES↗

TAP Absorption Coefficients

The data set of aerosol light absorption coefficients were collected by two tricolor absorption photometers (TAP; Brechtel Model 2901) in July and August, 2022 during the TRACER field campaign at the AMF1 site in La Porte, Texas. One of the TAPs at the La Porte site was an RGB model measuring aerosol light absorption at 652, 528, 467 nm, and the other was an UV model measuring absorption at the same red and green wavelengths but at an additional UV wavelength at 365 nm. Since TAP is a filter-based optical instrument using 47-mm glass fiber filters, the output absorption coefficients are corrected for filter loading and scattering effects based on a correction scheme developed in "Comment on ‘Calibration and Intercomparison of Filter-Based Measurements of Visible Light Absorption by Aerosols’" by John A. Ogren 2010. This uploaded dataset contains both the Ogren corrected absorption coefficients (column header with “ Ogren”) and the raw absorption coefficients without the correction scheme (column header with “_ Raw”). During the field campaign, the two TAPs operated side by side with a shared inlet at a flow rate of 2 lpm. In July, no inlet impactors/cyclones were installed; however, beginning in August, a PM2.5 cyclone inlet was installed.

54 ENVIRONMENTAL SCIENCES↗

Establishing robust correction schemes for improved and reliable ARM-AOS aerosol optical data products

Aerosol light absorption and scattering of solar radiation play an important role in the earth’s atmosphere in terms of direct and semi-direct radiative forcing. Optical parameters of importance to the US Department of Energy (DOE) climate models include absorption and scattering coefficients, single scattering albedo (SSA), absorption Angstrom exponents (AAE), and the asymmetry parameter (g). These parameters depend on aerosol size, shape and composition (refractive index), and are spectrally sensitive in the shortwave region. Additionally, these parameters have a complex dependency on the emission source, especially for carbonaceous aerosols. The DOE Atmospheric Radiation Measurement (ARM) user facility has deployed aerosol observing systems (AOS) containing several filter-based instruments to measure and constrain aerosol optical properties and related parameters at multiple sites worldwide. For measurement of aerosol light absorption, the AOS includes filter-based instruments (particle soot absorption photometer and tricolor absorption photometer) that infer particle-phase aerosol absorption coefficients at nominal red, green, and blue wavelength bands from the attenuation (ATN) of light passing through a particulate filter on which aerosols are deposited. Measurement of aerosol scattering is done in situ using nephelometers. By combining inferred absorption coefficients from filter-based ATN measurements and in situ scattering coefficients, value-added products (VAPs) such as SSA, AAE, and g are derived.

54 ENVIRONMENTAL SCIENCES↗

Absorption/transmission measurements of PSAP particle-laden filters from the Biomass Burning Observation Project (BBOP) field campaign

Absorptivity measurements with a laser-heating approach, referred to as the laser-driven thermal reactor (LDTR), were carried out in the infrared and applied at ambient (laboratory) nonreacting conditions to particle-laden filters from a three-wavelength (visible) particle/soot absorption photometer (PSAP). Here, the particles were obtained during the Biomass Burning Observation Project (BBOP) field campaign. The focus of this study was to determine the particle absorption coefficient from field-campaign filter samples using the LDTR approach, and compare results with other commercially available instrumentation (in this case with the PSAP, which has been compared with numerous other optical techniques).

54 ENVIRONMENTAL SCIENCES↗

Coastal Atmosphere and Sea Time Series (CoASTS)

The Coastal Atmosphere and Sea Time Series (CoASTS) Project aimed at supporting ocean color research and applications, from 1995 up to the time of publication of this document, has ensured the collection of a comprehensive atmospheric and marine data set from an oceanographic tower located in the northern Adriatic Sea. The instruments and the measurement methodologies used to gather quantities relevant for bio-optical modeling and for the calibration and validation of ocean color sensors, are described. Particular emphasis is placed on four items: (1) the evaluation of perturbation effects in radiometric data (i.e., tower-shading, instrument self-shading, and bottom effects); (2) the intercomparison of seawater absorption coefficients from in situ measurements and from laboratory spectrometric analysis on discrete samples; (3) the intercomparison of two filter techniques for in vivo measurement of particulate absorption coefficients; and (4) the analysis of repeatability and reproducibility of the most relevant laboratory measurements carried out on seawater samples (i.e., particulate and yellow substance absorption coefficients, and pigment and total suspended matter concentrations). Sample data are also presented and discussed to illustrate the typical features characterizing the CoASTS measurement site in view of supporting the suitability of the CoASTS data set for bio-optical modeling and ocean color calibration and validation.

Hooker, Stanford B.↗

Linear absorption coefficient of beryllium in the 50-300-A wavelength range

Transmittances of thin-film filters fabricated for an extreme-UV astronomy sounding-rocket experiment yield values for the linear absorption coefficient of beryllium in the 50-300-A wavelength range, in which previous measurements are sparse. The inferred values are consistent with the lowest data previously published and may have important consequences for extreme-UV astronomers.

Barstow, M. A.↗

Simultaneous transmission/absorption photometry of particle-laden filters from wildland fires during the Biomass Burning Observation Project (BBOP) field campaign

Transmissivity and absorptivity measurements were carried out simultaneously in the visible (wavelength of 532 nm) at laboratory conditions using particle-laden filters obtained from a three-wavelength particle/soot absorption photometer (PSAP). Here, the particles were collected on filters from wildland fires over the Pacific Northwest during the Department of Energy Biomass Burning Observation Project (BBOP) field campaign in 2013. The objective of this investigation was to apply this measurement approach, referred to as simultaneous transmission/absorption photometry (STAP), to estimate the aerosol extinction coefficient from actual field-campaign filter aerosol, and compare results with the PSAP. The STAP approach offers several advantages over the PSAP, including estimation of the extinction coefficient from temperature measurements (avoiding the complexities associated with filter reflectivity/scattering measurements), as well as determination of the filter optical properties and filter effects on particle absorption (resulting in particle absorption enhancement). The experimental arrangement included a laser probe beam impinging normal to the particle-coated surface of a vertically mounted filter, and a thermocouple placed flush in the middle of (and in thermal contact with) the filter uncoated back surface. With this simple arrangement, the transmissivity and absorptivity were determined simultaneously at a given laser beam wavelength. The measurement repeatability was better than 0.3 K (95% confidence level) for temperature and 0.4 mW for laser power. The limit of detection for the extinction coefficient was estimated to be (8–12) Mm -1 (95% confidence level) at about 1.9 mW laser power. The extinction coefficient was determined through measurement of both PSAP blank and exposed filters. Filters were obtained from nine different aircraft flights conducted during the BBOP campaign, representing different flight patterns, days, stages of burning, landscapes, and wildland fires. The STAP extinction coefficient matched the darkness of the filter coating, however the PSAP-filter results did not follow the same order. Although there were differences in transmissivity between the two techniques, the estimated values for absorption coefficient were in good agreement.

54 ENVIRONMENTAL SCIENCES↗

ABSORPTION OF p MODES BY THIN MAGNETIC FLUX TUBES

We study the interaction between p modes and the many magnetic fibrils that lace the solar convection zone. In particular, we investigate the resulting absorption of p-mode energy by the fibril magnetic field. Through mechanical buffeting, the p modes excite tube waves on the magnetic fibrils-in the form of longitudinal sausage waves and transverse kink waves. The tube waves propagate up and down the magnetic fibrils and out of the p-mode cavity, thereby removing energy from the incident acoustic waves. We compute the absorption coefficient associated with this damping mechanism and model the absorption that would be observed for magnetic plage. We compare our results to the absorption coefficient that is measured using the local-helioseismic technique of ridge-filtered holography. We find that, depending on the mode order and the photospheric boundary conditions, we can achieve absorption coefficients for simulated plage that exceed 50%. The observed increase of the absorption coefficient as a function of frequency is reproduced for all model parameters.

99 GENERAL AND MISCELLANEOUS↗

Mass absorption coefficients of Parylene N at soft X-ray and vacuum-ultraviolet wavelengths

Parylene N was selected as a bandpass filter for the extreme-ultraviolet telescope, flown on the Apollo-Soyuz Test Project in July 1975. The telescope measures stellar and diffuse cosmic radiation in the wavelength region from 45 to 170 A. In connection with this application, a systematic study was conducted of the mass absorption coefficient of the Parylene N. The results of the study for the wavelength region from 44 to 2536 A are reported.

Stern, R.↗

TU-F-CAMPUS-I-02: Validation of a CT X-Ray Source Characterization Technique for Dose Computation Using An Anthropomorphic Thorax Phantom

Purpose: To experimentally validate a rotational kV x-ray source characterization technique by computing CT dose in an anthropomorphic thorax phantom using an in-house dose computation algorithm (kVDoseCalc). Methods: The lateral variation in incident energy spectra of a GE Optima big bore CT scanner was found by measuring the HVL along the internal, full bow-tie filter axis. The HVL and kVp were used to generate the x-ray spectra using Spektr software, while beam fluence was derived by dividing the integral product of the spectra and in-air mass-energy absorption coefficients by in-air dose measurements along the bow-tie filter axis. Beams produced by the GE Optima scanner were modeled at 80 and 140 kVp tube settings. kVDoseCalc calculates dose by solving the linear Boltzmann transport equation using a combination of deterministic and stochastic methods. Relative doses in an anthropomorphic thorax phantom (E2E SBRT Phantom) irradiated by the GE Optima scanner were measured using a (0.015 cc) PTW Freiburg ionization chamber, and compared to computations from kVDoseCalc. Results: The agreement in relative dose between dose computation and measurement for points of interest (POIs) within the primary path of the beam was within experimental uncertainty for both energies, however points outside the primary beam were not. The average absolute percent difference for POIs within the primary path of the beam was 1.37% and 5.16% for 80 and 140 kVp, respectively. The minimum and maximum absolute percent difference for both energies and all POIs within the primary path of the beam was 0.151% and 6.41%, respectively. Conclusion: The CT x-ray source characterization technique based on HVL measurements and kVp can be used to accurately compute CT dose in an anthropomorphic thorax phantom.

60 APPLIED LIFE SCIENCES↗

UV photography of the earth and moon

This experiment obtained imagery of the earth and the moon at a series of wavelength intervals in the near ultraviolet. These photographs were used to aid in the interpretation of the UV appearance of other planets in the solar system, especially mars and venus. The filter and film characteristics are described, as well as the ozone absorption coefficient curve.

Owen, T. C.↗

Composite thin-foil bandpass filter for EUV astronomy Titanium-antimony-titanium

Thin metallic foils of antimony and titanium have been investigated in an attempt to develop an EUV filter with a bandpass from 350 to 550 A. A composite filter has been developed composed of antimony sandwiched between two titanium foils. The transmissions of sample composite foils and of pure titanium foils from 130 to 1216 A are presented. The absorption coefficients of anatimony and titanium and the effect of titanium oxide on the transmission are derived. The composite filter has been found to be quite stable and mechanically rugged. Among other uses, the filter shows substantial promise for EUV astronomy.

Jelinsky, P.↗

The impact of absorption coefficient on polarimetric determination of Berry phase based depth resolved characterization of biomedical scattering samples: a polarized Monte Carlo investigation

The modulation of the state of polarization of photons due to scatter generates associated geometric phase that is being investigated as a means for decreasing the degree of uncertainty in back-projecting the paths traversed by photons detected in backscattered geometry. In our previous work, we established that polarimetrically detected Berry phase correlates with the mean photon penetration depth of the backscattered photons collected for image formation. In this work, we report on the impact of state-of-linear-polarization (SOLP) filtering on both the magnitude and population distributions of image forming detected photons as a function of the absorption coefficient of the scattering sample. The results, based on Berry phase tracking implemented Polarized Monte Carlo Code, indicate that sample absorption plays a significant role in the mean depth attained by the image forming backscattered detected photons.

backscattered Mueller matrix↗

Continuous Light Absorption Photometer (CLAP) Instrument Handbook

Reliable measurements of aerosol light absorption are crucial for quantifying the radiative forcing of climate. As a consequence, light absorption measurements are recommended for all stations in the Global Atmosphere Watch network, which is coordinated by the World Meteorological Organization. Aerosol light absorption is often dominated by soot-like particles produced by the incomplete combustion of carbonaceous fuels, commonly termed "black carbon", and optical methods are the primary way that equivalent black carbon concentrations are derived. Two basic approaches are used for determining the aerosol light absorption coefficient: in situ methods where the absorption is measured while the particles are suspended in air, and filter-based methods where the particles are deposited on a filter for real-time optical analysis. In situ methods are inherently more accurate because the physical state of the particles can be changed by the act of filtration. Unfortunately, currently available instruments for in situ measurements are more expensive and difficult to operate than filter-based methods, making them better suited for use in intensive field campaigns or as laboratory reference instruments. Filter-based instruments, because of their lower cost and simpler operation, have been the preferred choice for long-term measurements of aerosol light absorption in monitoring networks.

54 ENVIRONMENTAL SCIENCES↗