Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Feeder Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Differential Privacy in Grid Kitchen: Implementation & Software Documentation

Sharing of power grid feeder models faces significant challenges due to the potential risk of exposing sensitive operational information. Traditional anonymization techniques have shown notable limitations in other sensitive domains, as evidenced by documented re-identification attacks that combine supposedly anonymized datasets with auxiliary information, raising concerns that similar vulnerabilities could affect power grid data. Consequently, there is a pressing need for a more rigorous privacy protection strategy that not only delivers formal mathematical guarantees but also preserves the analytical value of the shared models. To address this challenge, we have enhanced the Grid Kitchen framework by implementing differential privacy mechanisms within the distribution model dehydration pipeline. This implementation carefully calibrates and applies noise to sensitive attributes in feeder models according to configurable privacy levels—low, moderate, and high—each offering different balances between data utility and privacy protection. Our approach uses established noise functions (Gaussian for continuous data and Discrete Laplace for integer values) with parameters carefully calibrated so that the impact of individual data points is effectively masked in the final output. The integration leverages our Noise Catalog, which we developed to categorize feeder model properties by component type, data type, and sensitivity. This catalog guides the application of appropriate noise functions and privacy parameters ($\varepsilon$ and $\delta$) to each attribute, ensuring consistent privacy protection across the model while maintaining its structural integrity and analytical usefulness. This implementation also includes evaluation tools that allow model owners to assess the impact of privacy-preserving transformations before sharing data with external parties. This report provides documentation for the differential privacy capabilities added to the Grid Kitchen project. It includes a primer on differential privacy concepts and their importance in modern data sharing, details the architecture of our implementation, explains the privacy modes and parameter configurations, and offers practical guidance on using the code for applying differential privacy to grid feeder models. Through examples and code snippets, we demonstrate the effective application of these privacy-enhancing technologies, enabling utility operators and researchers to confidently share grid data while protecting sensitive information.

24 POWER TRANSMISSION AND DISTRIBUTION

Scalability of Real-time Distribution Models

This work will focus on developing the capabilities and validating the models for a sub transmission network with multiple feeders and microgrids. To achieve this scale of Hardware-in-the-loop (HitL) simulation, it is necessary to federate and collaborate. The work aims to design the large-scale feeder models to allow federation with complementary testbeds in the future. The feeder would be designed to be reconfigurable to put the system into a variety of modes. Aggregators models will be included in each distribution network’s federate to take control actions and interact with the management systems. Lastly, the feeder model will support large scale resilience studies involving complex Distributed Energy Resources (DER) controls, microgrid studies and emulation of complex data flows in future grid architectures.

24 POWER TRANSMISSION AND DISTRIBUTION

Grid Topology Discovery Algorithm Evaluation of Suitability for Utility Deployment (CRADA 606 Final Report)

This work presents the results of a field-informed demonstration aimed at evaluating the practical suitability of a topology discovery algorithm for utility environments. We demonstrated an algorithm that uses a graph-theory-informed state estimation approach for model selection. In collaboration with Survalent and Peninsula Light Co., the algorithm was applied to real feeder models and field measurements from supervisory control and data acquisition (SCADA) and advanced metering infrastructure (AMI) systems to identify the operational topology of a power distribution system. The demonstration assessed the algorithm’s performance under realistic data conditions, including sparse and noisy measurements, and examined its ability to identify the most likely network configurations. The results confirmed that the approach can effectively narrow down feasible topologies, providing operators with improved situational awareness of network status. Key lessons learned emphasize the need for systematic data validation and strategic sensor placement to enhance observability. These insights inform future deployment strategies and guide refinements for broader adoption in utility operations.

24 POWER TRANSMISSION AND DISTRIBUTION

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system

Data-Driven Protection Software to classify fault locations by protective zone in distribution systems with high PV penetration

The software contains (a) the source codes to generate Point-on-Wave (PoW) transient data for any feeder model in Alternative Transient Program (ATP) format. Codes provide options to change different steady state settings, including the loading condition and PV capacity and transient state setting like faults type, location and initiation time (b) data post-processing source code to converted data from native format to COMTRADE, csv, HDF5 (c) Docker container to train CNN to classify fault locations by protective zone. The container takes dataset and other training parameters (sampling rate, training epochs, batch size etc) as input to train CNN. The container writes back the trained CNN model, training and testing metrics and plots to the local workstation

Ramesh, Meghana

A Convolution Neural Network for Voltage Event Classification at a Photovoltaic Inverter

This paper presents a convolutional neural network (CNN) developed to identify voltage events in photovoltaic (PV) inverters. The CNN is trained on synthetic data generated using the IEEE 13-bus distribution feeder model and evaluated on field measured data collected from Energy Northwest’s Horn Rapids Solar, Storage, and Training (HRSST) facility. The study focuses on two common voltage events: faults and voltage sags. The CNN is configured to analyze voltage and current waveforms from three-phase PV systems, demonstrating excellent accuracy during training. Field data from the HRSST facility is employed to assess its real-world performance, where the CNN achieves perfect identification of faults and voltage sags in a sample of nine events. This work highlights the potential of the proposed method to enhance PV protection schemes, providing a robust foundation for improved voltage event detection and grid reliability.

Cornachione, Matthew A.

Defining a Platform Approach and Market Participation: Data Driven Business Models for Solid State Transformer-Based Synthetic Inertia and Voltage Stability Controls (CRADA Final Report, Project 1, Mod 1)

The primary objective of this project is to determine the incremental value created with the medium voltage solid-state transformer (MV SST) technology to different stakeholders in view of the updated DER grid regulations. This includes studying the benefits of the MV SST technology in a range of use cases for EV and DER penetration including (1) “corridor charging” for EVs and (2) solar plus storage (FERC 2222). The potential customers of this technology include utilities for EV charging, DER installers who must meet utility interconnection requirements, balancing authorities, and DER aggregators. The traditional transformers on the grid could be a limiting factor for the EV-grid integration as the distribution transformers were not designed to handle the dynamic and fluctuating EV charging loads. Thus, the issues such as voltage fluctuations, increased losses and reduced efficiency [1] can negatively impact the grid operation. To address these challenges, transformers with flexibility and adaptability become imperative to meet the evolving energy demands. In this regard, the concept of Medium Voltage Solid-State Transformers.

14 SOLAR ENERGY

Linear Solver for Electromagnetic Simulation of General Distribution Feeders

High-fidelity electromagnetic transient (EMT) modeling is required for accurate simulation and analysis of power system dynamics in modern distribution feeders. However, the high-fidelity of EMT models often leads to significant computational challenges, particularly in terms of computational resources and simulation time. This paper investigates the development and application of a detailed EMT model for general distribution feeders, with a focus on improving computational efficiency. A direct linear solver is proposed for a bordered block diagonal (BBD) matrix structure commonly encountered in a EMT model of distribution feeders. The solver integrates the Schur complement method with the block tridiagonal matrix algorithm to enhance the computational performance. The proposed solver is validated using the primary feeder of the IEEE 342-node test system, demonstrating its accuracy and efficiency in EMT simulations. Furthermore, the solver’s performance is benchmarked against MATLAB’s built-in linear solvers, showing significant improvements in computation time while maintaining high fidelity and accuracy in simulation results.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)

Improving Grid Awareness by Empowering Utilities with Machine Learning and Artificial Intelligence

Gap filling time series data typically depends on linear interpolation. More recently gap filling advancements include machine learning techniques. However, none leverage advanced learning approach that uses cohort training or a neighborhood informed approach, which is described in this report. The report also describes a physics informed approach using Reduced Order Models (ROM). There are several methods to capture the nature of the detailed system in aggregated models, however there is a trade-off for these methods developed for multiple applications. These methods have specific requirements and applications that includes consideration of dynamics or covering a larger range of operating conditions, etc. The various methods of aggregation are: 1) Thevenin equivalents for downstream networks 2) Equivalent feeder representation to capture downstream network losses accurately 3) Structured reduced order models for dynamics 4) System identification-based ROM (abstract dynamical model) Methods described in items 1 and 2 above are ideal for steady-state models and useful for this application. Of these two methods, based on the data availability, the targeted application, the reduced order model that is proposed to be developed is the equivalent feeder model representation. This includes a structure of the reduced order model whose parameters can be determined by the system load and losses with the meter measurements.

14 SOLAR ENERGY

Data-Driven Voltage Regulation of Distribution Grid Using Nonlinear Autoregressive Model with Exogenous Inputs (NARX)

This article proposes data-driven control via a nonlinear autoregressive model with exogenous inputs (NARX) for real-time voltage regulation of a modified feeder using reactive power sources. Traditional voltage control strategies rely on rule-based heuristics or optimization techniques, which often require detailed system models and extensive computational resources. The NARX-based controller learns system dynamics from historical data and predicts optimal reactive power dispatch in real-time for voltage correction. The proposed approach is evaluated on a power system feeder model under varying load and network conditions. Simulation results demonstrate that the NARX-based controller achieves improved voltage regulation, offering higher adaptability to system fluctuations. This study highlights the potential of data-driven control for enhancing the reliability of power distribution networks.

Donge, Vrushabh [ORNL] (ORCID:0000000306062803)

Advanced Measurements for Resilient Integration of Inverter-Based Resources: PROGRESS MATRIX Final Report

As nearly every aspect of the electric power grid undergoes rapid change, measurement technologies that support grid operation and planning must evolve as well. The rapid large-scale deployment of inverter-based resources (IBRs) vital to achieving the nation’s clean energy goals has in some cases led to negative impacts on the reliability and security of the bulk power system (BPS). Advanced power system measurements, including synchronized phasor and waveform measurements, are key to making IBR integration secure and reliable. To this end, the Department of Energy (DOE) initiated the PROGRESS MATRIX project to develop advanced measurement capabilities and analytics that will accelerate adoption of IBRs while improving the reliability and resilience of the BPS. This report discusses the outcomes of the project, which was a joint effort between the Pacific Northwest National Laboratory (PNNL), Oak Ridge National Laboratory (ORNL), the National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL). In the project’s first year, PNNL, NREL, and ORNL partnered with the Bonneville Power Administration (BPA), the Western Area Power Administration (WAPA), and Kauai Island Utility Cooperative (KIUC) to understand their existing measurement capabilities and the gaps limiting deployment of IBR-focused measurement systems and analytics. The other primary activity in the first year was deployment of GridSweep instruments, which provide unprecedented precision in waveform measurement while probing distribution systems. The instruments were deployed at Dominion Energy and the University of California, Riverside. In the project’s second year, the input from partner utilities and collected measurements were used to advance measurement capabilities. Twelve analytical methods spanning disturbance analysis, power plant evaluation, feeder evaluation, and modeling were developed. Two software tools were developed, one to analyze GridSweep measurements and another to automatically evaluate the control performance of power plants connected to the BPS. Testbeds at ORNL and NREL were augmented to better enable studies of IBR integration. The project culminated in demonstrations of these analytical methods, software tools, and testbeds, both in the field and in the laboratory. This report discusses these various accomplishments and documents the significant progress in developing advanced measurement capabilities to support the secure, reliable, and accelerated adoption of IBRs in the BPS.

24 POWER TRANSMISSION AND DISTRIBUTION

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY

Aggregate data‐driven dynamic modeling of active distribution networks with DERs for voltage stability studies

Abstract Electric distribution networks increasingly host distributed energy resources based on power electronic converter (PEC) toward active distribution networks (ADN). Despite advances in computational capabilities, electromagnetic transient models are limited in scalability because of their reliance on exact data about the distribution system and each of its components. Similarly, the use of the DER_A model, which is intended to examine the combined dynamic behavior of many DERs, is limited by the difficulty in parameterization. There is a need for improved dynamic models of DERs for use in large power system simulations for stability analysis. This paper proposes an aggregate model‐free, data‐driven approach for deriving a dynamic partitioned model (DPM) of ADNs. Detailed residential distribution feeders were first developed, including PEC‐based DERs and composite load models (CMLDs), from which the aggregated DPM was derived. The performance was evaluated through various case studies and validated against the detailed ADN model and state‐of‐the‐art DER_A model with CMLD. The data‐driven DPM achieved a of over 90%, accurately representing the aggregated dynamic behavior of ADNs. Furthermore, the DPM significantly accelerated the simulation process with a computational speedup of 68 times compared to the detailed ADN and a 3.5 times speedup compared to the DER_A CMLD model.

42 ENGINEERING

Black-Starting Microgrids Using Inverter-Based Distributed Energy Resources

Recent trends in power systems show increasing deployment of inverter-based distributed energy resources (DERs) at the distribution level. Efforts have also been made to use inverter-based DERs for system restoration of critical sections of distribution feeders. In the past few years, there has been active consideration of using local grid-forming (GFM) DERs, which can form their own voltage and frequency, to black-start microgrids instead of waiting for the bulk system for supply restoration. However, using current-limited inverter-based DERs for black-start operations with high inrush currents can pose some technical challenges. This paper presents detailed electromagnetic transient studies on a digital real-time simulator to assess the operational feasibility of using local inverter-based GFM DERs for microgrid black-start operations as a bottom-up approach instead of a top-down approach where the substation is used to restore critical sections of the feeder. The paper presents key modeling details for distribution system components for studying GFM DER-based microgrid black-start operations. The paper presents simulation results comparing different black-start approaches using GFM DERs for two test systems: i) a simple test microgrid and ii) a real-world utility microgrid currently being designed and deployed by Holy Cross Energy in Colorado.

black start

Distribution Feeder Characteristics and Their Resiliency to Natural Hazards

This paper introduces a method and approach for initially screening actions to improve the reliability of distribution systems exposed to three natural hazards (wildlife, weather, and vegetation). The method is well-suited to needs and capabilities of smaller utilities because it relies on readily available information and does not depend on simulations involving detailed engineering models. The method involves first aggregating feeders into like types and then correlating them, separately by hazard, to standard measures of reliability, namely, System Average Interruption Frequency Index (SAIFI) and System Average Interruption Duration Index (SAIDI), and the individual constituents of these measures. The correlations provide both new insights into the efficacy of accepted reliability management practices while and re-confirm long-understood, accepted practices. Importantly, the method does not seek to replace the need for detailed engineering analysis. Instead, in view of the significant costs involved in conducting these more involved analyses, the method is intended to help smaller utilities prioritize their more limited resources to maximize the efficacy of actions they take to improve reliability.

24 POWER TRANSMISSION AND DISTRIBUTION

Energy Scheduling-based Operating Envelopes including a Distribution System Branch Screening Algorithm

This paper presents an energy scheduling-based formulation for computing operating envelopes including a distribution branch screening algorithm, termed DBS-ES. The contribution of the paper is two-fold: firstly, it presents an innovative methodology for calculating operating envelopes using energy scheduling (baseline), and secondly, it enhances this methodology by incorporating a custom distribution branch screening algorithm (DBS-ES). The custom algorithm leverages power system knowledge to reduce both model build time and total processing time while maintaining the same scheduling results as the baseline. The effectiveness of the proposed approach is demonstrated through experiments on the IEEE13, IEEE123, and EPRI Secondary test feeders. Results highlight a 24.5% decrease in model build time and an 8.17% decrease in total processing time when using DBS-ES compared to the baseline, specifically for the IEEE123 test feeder. Additionally, the paper briefly discusses the influence of utility-controlled storage on computing operating envelopes, noting a general incre

24 POWER TRANSMISSION AND DISTRIBUTION

Idaho National Laboratory Integrated Multisite SSHAC Level 3: Probabilistic Volcanic Hazards Assessment

The Idaho National Laboratory (INL) resides on the eastern Snake River Plain (ESRP), part of the Snake River Plain (SRP) with a complex origin and geologic history of volcanism. Much of the Quaternary (last 2.58 million years) volcanism within 400 km of INL is genetically associated with a major thermal anomaly referred to as the Yellowstone hotspot, which is currently located more than 180 km northeast of INL. Near INL, local volcanic sources include silicic domes near its southern border, and numerous dike-fed basaltic vents of the ESRP, some of which are near or within the INL boundaries. Quantitative probabilistic assessments of screened-in volcanic hazardous phenomena for nine different facility complexes at the INL are presented for a Senior Seismic Hazard Analysis Committee (SSHAC) Level 3 (SL3) study. The comprehensive, integrated multisite SSHAC study consists of a single regional Probabilistic Volcanic Hazards Assessment (PVHA) that pertains to all nine INL facility complexes, with site-specific information developed at each respective area of interest (AOI), referred to as the "INL facility AOI" (Figure ES-1). Hazard products are generated for specified INL facility AOIs for use by multiple stakeholders from different agencies in risk-informed decision-making regarding site selection, operations, and design of nuclear facilities at INL, consistent with U.S. Department of Energy (DOE) and U.S. Nuclear Regulatory Commission (NRC) regulatory guidance. The study also serves as the basis for future periodic safety assessments required for existing DOE facilities, such as 10-year evaluations of natural-phenomena hazards. Elements of the INL PVHA including initial characterization, screening, quantitative assessments of eruption and hazard potential, and consideration of facility needs are conducted using the three phases of the SSHAC process: evaluation, integration, and documentation. As per regulatory guidance, the SSHAC framework provided the necessary processes and procedures for the PVHA Technical Integration (TI) team, at three workshops, five formal working meetings and many TI team remote meetings, to conduct initial characterization, screen the volcanic hazards, create PVHA model inputs, exercise those models in the PVHA, consider facility-specific volcanic hazard needs, and perform final hazard calculations. The Participatory Peer Review Panel (PPRP) provided independent oversight and performed process and technical reviews of the PVHA throughout its duration. The study included an extensive New Data Collection and Analyses (NDCA) program developed by the PVHA TI team to reduce uncertainties in hazard-significant elements in the PVHA model. NDCA activities generated 20 reports providing important contributory datasets and results to the project database for characterizing the ESRP. For example, a report compiling the dimensions of ESRP shield volcanoes and lava fields was used to construct volcanic footprints (areas of impact), was compared with data from INL subsurface cores, and was used to validate the results of lava-flow inundation modeling on the contemporary terrain. Another example is the acquisition of aeromagnetic data over INL and its surrounding area, with maps of buried magmatic features (e.g., subsurface volcanoes and swarms of feeder dikes) that informed the PVHA conceptual model of volcanism. The SSHAC evaluation process was used to conduct all elements of the PVHA including initial characterization and screening. Existing data and NDCA activities provided the foundation to develop the tectonomagmatic conceptual model of volcanism for the region of geographical interest in the SRP and Yellowstone hotspot volcanic system, and for considering volcanoes in the western US. Considering Quaternary volcanic sources active during this period, the screening approach identified and evaluated magma compositions, types of eruptive and intrusive phenomena, types of hazardous phenomena, and proximity of sources to INL. The PVHA TI team evaluated 18 types of magmatic sources in terms of 20 potentially hazardous phenomena, resulting in 360 screening decisions. The screening process resulted in 140 screened-in hazardous volcanic phenomena for Quaternary volcanic sources 1) proximal to INL facility complexes in the ESRP (64 basaltic and 54 silicic), 2) regional sources associated with the Yellowstone caldera system and Blackfoot Reservoir volcanic field (7), and 3) more distal sources from thirteen Cascade volcanoes and two volcanoes at Long Valley caldera (CA).

58 GEOSCIENCES

Enhancing the Survivability of Power Systems With Grid-Edge DERs Against DoS Attacks

Power system survivability, defined as the ability of a system to maintain steady-state functionality under varying operational conditions, reflects its resilience against disturbances. While existing research primarily focuses on physical-layer disturbances, the increasing prevalence of grid-edge DERs, which are primarily used for integrating renewable energy, has significantly expanded the cyber attack surface. As a result, operational disruptions caused by cyber threats are posing significant challenges to system survivability and cannot be overlooked. To fill this gap, we redefine system survivability to incorporate the cyber layer’s status and propose a Distributionally Robust Optimization (DRO) approach to enhance power system survivability against potential cyber-physical threats. In this paper, we first analyze the operational guidelines of systems with a high penetration of DERs under various cyber network conditions and redefine survivability in this context. Next, we focus on the most common cyber threat, Denial-of-Service (DoS) attacks, and develop a corresponding attack model. This model allows for the creation of a kernel-based ambiguity set that captures attack uncertainties using historical data. Finally, we transform the proposed DRO model as a tractable optimization problem, with its solution providing an optimal cyber redundancy plan to enhance system survivability in DoS attack scenarios. Simulation results on the IEEE 13-node and 123-node test feeders demonstrate the effectiveness of our proposed model in improving system survivability. This model can also be expanded to include other types of common attacks and serve as a comprehensive planning tool to improve overall cyber physical survival of the system.

cybersecurity